Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Chemosphere ; 95: 329-35, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24120015

RESUMO

Chemical composition data for the Danube River and its tributaries sediments were analyzed using positive matrix factorization (PMF). The objective was to identify both natural and anthropogenic sources affecting Danube Basin. During the Joint Danube Survey 2 (JDS2) campaign 148 bottom sediments samples were collected. The following elements were analyzed using the X-ray fluorescence technique: Al, As, Ca, Cd, Cl, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, P, Pb, S, Si, Ti, V and Zn. Mercury was determined by cold vapour atomic absorption spectrometry. Three factors were obtained considering the whole dataset (Danube and tributaries), identified as: (i) carbonate component characterized by Ca and Mg; (ii) alumino-silicate component dominated by Si and Al content and the presence of some metals attributed to natural processes; (iii) anthropogenic source identified by Hg, S, P and some heavy metals load. To better characterize the role of tributaries, the Danube and tributaries datasets, were also analyzed separately. The same three factor structures were identified in the Danube dataset. For the tributaries, a four-factor source model gave one further factor dominated by S and P, which could be attributed to the use of fertilizers in agriculture.


Assuntos
Monitoramento Ambiental/métodos , Sedimentos Geológicos/química , Rios/química , Poluentes Químicos da Água/análise , Agricultura , Europa Oriental , Metais Pesados/análise , Análise Multivariada
2.
Rev Sci Instrum ; 84(3): 033503, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23556817

RESUMO

A semiconductor detector coupled with a neutron converter is a good candidate for neutron detection, especially for its compactness and reliability if compared with other devices, such as (3)He tubes, even though its intrinsic efficiency is rather lower. In this paper we show a neutron detector design consisting of a 3 cm × 3 cm silicon pad detector coupled with one or two external (6)LiF layers, enriched in (6)Li at 95%, placed in contact with the Si active surfaces. This prototype, first characterized and tested at INFN Laboratori Nazionali del Sud and then at JRC Ispra, was successfully shown to detect thermal neutrons with the expected efficiency and an outstanding gamma rejection capability.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA