Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cereb Blood Flow Metab ; 28(4): 684-96, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18183032

RESUMO

Oxidative stress plays a significant role in secondary damage after severe traumatic brain injury (TBI); and melatonin exhibits both direct and indirect antioxidant effects. Melatonin deficiency is deleterious in TBI animal models, and its administration confers neuroprotection, reducing cerebral oedema, and improving neurobehavioural outcome. This study aimed to measure the endogenous cerebrospinal fluid (CSF) and serum melatonin levels post-TBI in humans and to identify relationships with markers of oxidative stress via 8-isoprostaglandin-F2alpha (isoprostane), brain metabolism and neurologic outcome. Cerebrospinal fluid and serum samples of 39 TBI patients were assessed for melatonin, isoprostane, and various metabolites. Cerebrospinal fluid but not serum melatonin levels were markedly elevated (7.28+/-0.92 versus 1.47+/-0.35 pg/mL, P<0.0005). Isoprostane levels also increased in both CSF (127.62+/-16.85 versus 18.28+/-4.88 pg/mL, P<0.0005) and serum (562.46+/-50.78 versus 126.15+/-40.08 pg/mL (P<0.0005). A strong correlation between CSF melatonin and CSF isoprostane on day 1 after injury (r=0.563, P=0.002) suggests that melatonin production increases in conjunction with lipid peroxidation in TBI. Relationships between CSF melatonin and pyruvate (r=0.369, P=0.049) and glutamate (r=0.373, P=0.046) indicate that melatonin production increases with metabolic disarray. In conclusion, endogenous CSF melatonin levels increase after TBI, whereas serum levels do not. This elevation is likely to represent a response to oxidative stress and metabolic disarray, although further studies are required to elucidate these relationships.


Assuntos
Lesões Encefálicas/líquido cefalorraquidiano , Encéfalo/metabolismo , Melatonina/líquido cefalorraquidiano , Estresse Oxidativo/fisiologia , Adulto , Idoso , Lesões Encefálicas/sangue , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Isoprostanos/líquido cefalorraquidiano , Masculino , Melatonina/sangue , Microdiálise , Pessoa de Meia-Idade
2.
Innovations (Phila) ; 13(2): 97-103, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29697598

RESUMO

OBJECTIVE: Leg ischemia is a serious complication of femoral artery cannulation. The primary aim of this study was to assess the safety and efficacy of a novel bidirectional femoral arterial cannula (Sorin Group USA, a wholly owned subsidiary of LivaNova PLC, Arvada, CO USA) that provides both antegrade and retrograde flow, in patients undergoing peripheral cannulation for cardiopulmonary bypass during cardiac surgery. METHODS: Patients undergoing routine cardiac surgery requiring femoral artery cannulation for cardiopulmonary bypass were identified preoperatively. Informed written consent was obtained in all cases. Bidirectional cannula insertion used either a surgical cut-down and wire through needle approach or a percutaneous technique. Flow in the superficial femoral artery was assessed using Doppler ultrasound after commencement of cardiopulmonary bypass. Lower limb perfusion was assessed using reflectance near-infrared spectroscopy to measure regional oxygen saturations in the cannulated limb during cardiopulmonary bypass. RESULTS: Fifteen patients (median age = 61.3 years, range = 26-79 years, 10 males, 5 females) underwent femoral arterial cannulation using the novel bidirectional femoral cannula between August 2016 and May 2017. Fourteen cannulae were inserted directly into the femoral artery via a surgical cut-down and wire through needle technique. One bidirectional cannula was inserted using a percutaneous insertion technique. Indications included minimally invasive mitral and aortic valve surgery, thoracic aortic aneurysm repair, and redo cardiac surgery. The median duration of cardiopulmonary bypass was 129 minutes (range = 53-228 minutes). The cannula was inserted and positioned without difficulty in 14 of 15 patients. Incorrect sizing and arterial spasm prevented correct cannula positioning in one patient. Antegrade flow in the superficial femoral artery was observed on Doppler ultrasound in 12 of 12 patients in which this was performed. Continuous stable distal perfusion was demonstrated in the cannulated limb in 14 of 15 patients. No procedural complications occurred in the immediate or convalescent postoperative period. CONCLUSIONS: This study demonstrates that in patients undergoing femoral arterial cannulation for cardiopulmonary bypass during cardiac surgery, the use of a novel bidirectional cannula is safe and easy to insert and provides stable distal perfusion of the cannulated limb. Use of the device should largely obviate the need to insert a separate downstream perfusion cannula or use other techniques to protect against lower limb ischemia. Further research on a larger scale and in different patient populations is now warranted.


Assuntos
Cânula/normas , Procedimentos Cirúrgicos Cardíacos/métodos , Cateterismo Periférico/métodos , Artéria Femoral/cirurgia , Perfusão/instrumentação , Doenças Vasculares Periféricas/complicações , Adulto , Idoso , Aneurisma da Aorta Torácica/cirurgia , Valva Aórtica/cirurgia , Ponte Cardiopulmonar/métodos , Ponte Cardiopulmonar/estatística & dados numéricos , Cateterismo Periférico/efeitos adversos , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Isquemia/patologia , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Valva Mitral/cirurgia , Doenças Vasculares Periféricas/diagnóstico por imagem , Doenças Vasculares Periféricas/patologia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ultrassonografia Doppler
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA