J Public Health Manag Pract ; 25 Suppl 1, Lead Poisoning Prevention: S23-S30, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30507766

RESUMO

CONTEXT: The Lead and Multielement Proficiency (LAMP) program is an external quality assurance program promoting high-quality blood-lead measurements. OBJECTIVES: To investigate the ability of US laboratories, participating in the Centers for Disease Control and Prevention (CDC) LAMP program to accurately measure blood-lead levels (BLL) 0.70 to 47.5 µg/dL using evaluation criteria of ±2 µg/dL or 10%, whichever is greater. METHODS: The CDC distributes bovine blood specimens to participating laboratories 4 times per year. We evaluated participant performance over 5 challenges on samples with BLL between 0.70 and 47.5 µg/dL. The CDC sent 15 pooled samples (3 samples shipped in 5 rounds) to US laboratories. The LAMP laboratories used 3 primary technologies to analyze lead in blood: inductively coupled plasma mass spectrometry, graphite furnace atomic absorption spectroscopy, and LeadCare technologies based on anodic stripping voltammetry. Laboratories reported their BLL analytical results to the CDC. The LAMP uses these results to provide performance feedback to the laboratories. SETTING: The CDC sent blood samples to approximately 50 US laboratories for lead analysis. PARTICIPANTS: Of the approximately 200 laboratories enrolled in LAMP, 38 to 46 US laboratories provided data used in this report (January 2017 to March 2018). RESULTS: Laboratory precision ranged from 0.26 µg/dL for inductively coupled plasma mass spectrometry to 1.50 µg/dL for LeadCare instruments. All participating US LAMP laboratories reported accurate BLL for 89% of challenge samples, using the ±2 µg/dL or 10% evaluation criteria. CONCLUSIONS: Laboratories participating in the CDC's LAMP program can accurately measure blood lead using the current Clinical Laboratory Improvement Amendments of 1988 guidance of ±4 µg/dL or ±10%, with a success rate of 96%. However, when we apply limits of ±2 µg/dL or ±10%, the success rate drops to 89%. When challenged with samples that have target values between 3 and 5 µg/dL, nearly 100% of reported results fall within ±4 µg/dL, while 5% of the results fall outside of the acceptability criteria used by the CDC's LAMP program. As public health focuses on lower blood lead levels, laboratories must evaluate their ability to successfully meet these analytical challenges surrounding successfully measuring blood lead. In addition proposed CLIA guidelines (±2 µg/dL or 10%) would be achievable performance by a majority of US laboratories participating in the LAMP program.


Assuntos
Técnicas de Laboratório Clínico/normas , Chumbo/análise , Garantia da Qualidade dos Cuidados de Saúde/métodos , Centers for Disease Control and Prevention, U.S./organização & administração , Centers for Disease Control and Prevention, U.S./estatística & dados numéricos , Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/estatística & dados numéricos , Humanos , Chumbo/sangue , Desenvolvimento de Programas/métodos , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Estados Unidos
2.
At Spectrosc ; 39(3): 95-99, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32336845

RESUMO

A probing study to establish a reliable and robust method for determining the iodine concentration using the ELAN® DRC™ II ICP-MS was performed in combination with a sample digestion and filtration step. Dairy products from locally available sources were evaluated to help determine the possibility and need for further evaluations in relation to the U.S. population's iodine intake. Prior to analysis, the samples were aliquoted and digested for 3 hours at 90±3 °C. Dilution and filtration were performed, following the digestion. The sample extract was analyzed, and the results were confirmed with NIST SRM 1549a Whole Milk Powder. Further experimentation will need to be performed to optimize the method for projected sample concentration and throughput.