Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Respir J ; 63(6)2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38548291

RESUMO

BACKGROUND: Differences in the pharyngeal site of collapse influence efficacy of non-continuous positive airway pressure therapies for obstructive sleep apnoea (OSA). Notably, complete concentric collapse at the level of the palate (CCCp) during drug-induced sleep endoscopy (DISE) is associated with reduced efficacy of hypoglossal nerve stimulation, but CCCp is currently not recognisable using polysomnography. Here we develop a means to estimate DISE-based site of collapse using overnight polysomnography. METHODS: 182 OSA patients provided DISE and polysomnography data. Six polysomnographic flow shape characteristics (mean during hypopnoeas) were identified as candidate predictors of CCCp (primary outcome variable, n=44/182), including inspiratory skewness and inspiratory scoopiness. Multivariable logistic regression combined the six characteristics to predict clear presence (n=22) versus absence (n=128) of CCCp (partial collapse and concurrent tongue base collapse excluded). Odds ratios for actual CCCp between predicted subgroups were quantified after cross-validation. Secondary analyses examined complete lateral wall, tongue base or epiglottis collapse. External validation was performed on a separate dataset (ntotal=466). RESULTS: CCCp was characterised by greater scoopiness (ß=1.5±0.6 per 2sd, multivariable estimate±se) and skewness (ß=11.4±2.4) compared with non-CCCp. The odds ratio for CCCp in predicted positive versus negative subgroups was 5.0 (95% CI 1.9-13.1). The same characteristics provided significant cross-validated prediction of lateral wall (OR 6.3, 95% CI 2.4-16.5), tongue base (OR 3.2, 95% CI 1.4-7.3) and epiglottis (OR 4.4, 95% CI 1.5-12.4) collapse. CCCp and lateral wall collapse shared similar characteristics (skewed, scoopy), diametrically opposed to tongue base and epiglottis collapse characteristics. External validation confirmed model prediction. CONCLUSIONS: The current study provides a means to recognise patients with likely CCCp or other DISE-based site of collapse categories using routine polysomnography. Since site of collapse influences therapeutic responses, polysomnographic airflow shape analysis could facilitate precision site-specific OSA interventions.


Assuntos
Endoscopia , Polissonografia , Apneia Obstrutiva do Sono , Humanos , Masculino , Feminino , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Pessoa de Meia-Idade , Adulto , Modelos Logísticos , Sono , Idoso , Língua/fisiopatologia , Faringe/fisiopatologia , Nervo Hipoglosso , Análise Multivariada , Palato , Epiglote/fisiopatologia , Pressão Positiva Contínua nas Vias Aéreas
2.
Eur Arch Otorhinolaryngol ; 281(5): 2281-2291, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38052757

RESUMO

PURPOSE: Recent literature suggests that tinnitus can impact cognition, but results were varied due to a diversity in investigated aspects of cognition and utilized tests, as well as the possible influence of confounding factors. The purpose of this study was to assess the impact of tinnitus loudness on cognition by use of a within-subjects design in patients with a cochlear implant (CI). In this population, tinnitus loudness can be modulated by switching the CI on or off as CI is known to highly suppress tinnitus. METHODS: A total of 18 CI users completed two versions of the Repeatable Battery for Assessment of Neuropsychological Status for Hearing Impaired individuals (RBANS-H), once in unaided condition and once in best aided condition. Tinnitus suppression was defined as a difference in score on a visual-analogue scale (VAS) of at least one point out of ten between these two conditions. RESULTS: No significant differences in RBANS-H scores were found between the suppression and no suppression group, nor for the suppression group alone. No significant correlations between tinnitus loudness and RBANS-H were found, neither for the suppression group alone, nor for the group as a whole. CONCLUSION: The current study shows no significant effect of tinnitus loudness on cognition, which contradicts previous literature. This discrepancy could be explained by the use of a within-subjects design, which controls for confounding factors. Future research should include a larger and more diverse study sample to draw definitive conclusions on this topic.


Assuntos
Implante Coclear , Implantes Cocleares , Zumbido , Humanos , Implante Coclear/métodos , Zumbido/cirurgia , Cognição
3.
Respir Res ; 24(1): 143, 2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37259138

RESUMO

BACKGROUND: Continuous positive airway pressure (CPAP) is the mainstay of treatment for obstructive sleep apnea (OSA). However, data about its effect on the upper airway, especially the epiglottis, are scarce. The aim of this study was to investigate the changes in upper airway dimensions and inspiratory flow in response to incremental pressure levels. METHODS: This is a secondary analysis of a prospective clinical trial in which patients with moderate to severe OSA underwent drug-induced sleep endoscopy with simultaneous recordings of flow and mask pressure. CPAP was titrated in small increments. For each pressure level a representative 3-breath segment was selected to determine specific flow features. The corresponding endoscopic footage was reviewed to assess the degree of upper airway collapse in a semi-quantitative manner. RESULTS: A total of 214 breath segments were obtained from 13 participants (median [Q1-Q3]; apnea-hypopnea index, 24.9 [20.1-43.9] events/h; body mass index 28.1 [25.1-31.7] kg/m²). CPAP significantly increased cross-sectional dimensions of the soft palate, lateral walls and tongue base, but not of the epiglottis, and induced epiglottis collapse in one subject. Increased pressure improved peak inspiratory flow and median ventilation in all patients, even in the presence of persistent epiglottis collapse. CONCLUSION: CPAP does not effectively address epiglottis collapse in patients with OSA. However, it normalizes inspiratory flow regardless of its effect on the epiglottis. This clinical trial was registered on January 18th, 2020 on ClinicalTrials.gov with identifier NCT04232410.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Apneia Obstrutiva do Sono , Humanos , Estudos Transversais , Estudos Prospectivos , Respiração , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia
4.
Brain ; 145(12): 4222-4231, 2022 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-36450310

RESUMO

Transcranial direct current stimulation (tDCS) has been proposed as a potential intervention for subjective tinnitus, but supporting evidence remains limited. We aimed to investigate the effect of anodal high-definition tDCS of the left temporal area and right dorsolateral prefrontal cortex on tinnitus severity. This double-blind randomized controlled trial included 77 patients (age range 18-79, 43 male) with chronic subjective tinnitus as their primary complaint. Thirty-eight subjects received six consecutive sessions of dual-site sequential high-definition-tDCS with electrodes positioned over the left temporal area and right dorsolateral prefrontal cortex. Both areas were stimulated for 15 min per session, with total stimulation time amounting to 30 min. Thirty-nine subjects received sham stimulation. The primary outcome measure was the change in tinnitus severity, as evaluated by the Tinnitus Functional Index, from baseline to a follow-up visit at 8 ± 2 weeks after treatment completion. Secondary outcomes included changes in perceived tinnitus loudness, as measured with a visual analogue scale and a tinnitus matching procedure, as well as scores on the Hospital Anxiety and Depression Scale, and the Hyperacusis Questionnaire. No differences in Tinnitus Functional Index change scores were identified between the active treatment and sham control groups (linear regression: P = 0.86). The Tinnitus Functional Index scores decreased significantly over time in both groups (P = 0.0012), indicating the presence of a considerable placebo effect. These change scores were significantly influenced by sex (linear regression: P = 0.037) and baseline symptoms of anxiety (linear regression: P = 0.049) in both groups. In general, Tinnitus Functional Index scores decreased more profoundly in males and in subjects with a higher degree of anxiety at baseline. None of the included secondary measures differed significantly between experimental arms. Our results suggest that dual-site sequential high-definition-tDCS of the left temporal area and right dorsolateral prefrontal cortex does not alleviate tinnitus severity. Interestingly, in our study population, fluctuations in tinnitus severity were influenced by gender and concurrent mental condition. It is therefore important to take these factors into account when conducting or planning randomized controlled trials in tinnitus populations.


Assuntos
Zumbido , Estimulação Transcraniana por Corrente Contínua , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Método Duplo-Cego , Córtex Pré-Frontal , Ensaios Clínicos Controlados Aleatórios como Assunto , Zumbido/diagnóstico , Zumbido/terapia , Estimulação Transcraniana por Corrente Contínua/métodos , Resultado do Tratamento
5.
Sleep Breath ; 27(2): 693-701, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35779166

RESUMO

PURPOSE: Hypoglossal nerve stimulation (HNS) has been shown to treat obstructive sleep apnea (OSA) effectively. The aim of this study was to compare HNS with positive airway pressure (PAP) treatment regarding outcome parameters: (1) sleepiness, (2) apnea-hypopnea index (AHI), and (3) effectiveness. METHODS: Propensity score matching with nearest neighbor algorithm was used to compare outcomes of HNS and PAP therapy in a real-world setting. Data were collected at baseline and 12 months after initiating OSA treatment including demographics, Epworth Sleepiness Scale (ESS), AHI, and objective adherence data. To account for overall treatment efficacy, the mean disease alleviation (MDA) was calculated. RESULTS: Of 227 patients who received treatment consecutively, 126 could be matched 1:1 with regard to age, body mass index, and AHI. After matching, no statistically significant differences between the groups were found. A clinically important symptom improvement was seen at 12 months in both cohorts, though there was a greater difference in ESS improvement in patients treated with HNS (8.0 ± 5.1 points vs. 3.9 ± 6.8 points; p = 0.042). In both groups, mean posttreatment AHI was significantly reduced (HNS: 8.1 ± 6.3/h; PAP: 6.6 ± 8.0/h; p < 0.001). Adherence after 12 months among patients treated with HNS was higher than in those receiving PAP therapy (5.0 ± 2.6 h/night; 4.0 ± 2.1 h/night) but not with statistical significance. Overall effectiveness calculated with the MDA was 59% in patients treated with HNS compared to 51% receiving PAP. CONCLUSION: Patients treated with HNS therapy had significantly greater improvements in daytime sleepiness compared to PAP therapy, while the mean reduction of AHI and overall effectiveness were comparable for both treatments. TRIAL REGISTRATION: ClinicalTrial.gov Identifier: NCT03756805.


Assuntos
Terapia por Estimulação Elétrica , Apneia Obstrutiva do Sono , Humanos , Pressão Positiva Contínua nas Vias Aéreas , Nervo Hipoglosso , Modalidades de Fisioterapia , Apneia Obstrutiva do Sono/terapia , Sonolência , Resultado do Tratamento
6.
J Med Internet Res ; 25: e39076, 2023 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-36757768

RESUMO

BACKGROUND: Tinnitus is a highly prevalent symptom affecting 10%-20% of the adult population. Most patients with tinnitus have chronic tinnitus, which can directly or indirectly disrupt their daily life and negatively affect the health-related quality of life. Therefore, patients with tinnitus are frequently in need of costly and time-consuming treatments. As an answer, telerehabilitation interventions are on a rise to promote self-management in patients with tinnitus and reduce their dependency on in-person care. OBJECTIVE: This systematic review aimed to provide an overview of the research concerning the effectiveness of telerehabilitation interventions for self-management of tinnitus. METHODS: This systematic review adheres to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Studies were eligible for inclusion if study participants were adult patients with complaints of primary subjective tinnitus and the study intervention comprised any possible telerehabilitation form for the self-management of tinnitus complaints. A search for eligible studies was conducted on PubMed, ScienceDirect, Scopus, Web of Science, and Cochrane Library. The Cochrane Risk of Bias 2 tool was used to the assess risk of bias. RESULTS: In total, 29 articles were found eligible, and of these, 5 (17%) studied multiple telerehabilitation forms. Internet-based cognitive behavioral treatment with guidance by a psychologist or audiologist was examined in 17 studies (n=1767), internet-based cognitive behavioral treatment without guidance was examined in 4 studies (n=940), self-help manuals were examined in 1 study (n=72), technological self-help devices were examined in 2 studies (n=82), smartphone apps were examined in 8 studies (n=284), and other internet-based interventions were examined in 2 studies (n=130). These rehabilitation categories were proven to be effective in decreasing tinnitus severity and relieving tinnitus distress as measured by tinnitus questionnaires such as Tinnitus Functional Index, Tinnitus Handicap Inventory, or Tinnitus Reactions Questionnaire. However, dropout rates were often high (range 4%-71.4%). All studies reported between some concerns and high concerns of risk of bias, resulting in low to moderate certainty levels. CONCLUSIONS: Overall, there is low to moderate quality evidence that telerehabilitation interventions effectively reduce tinnitus severity and distress. These interventions form a possible tool to improve the self-management capacities of the patient and the accessibility of tinnitus care as a replacement or an addition to in-person care. Nevertheless, barriers such as lack of time, engagement, motivation, and openness of the patient causing high dropout should be considered. TRIAL REGISTRATION: PROSPERO International Prospective Register of Systematic Reviews CRD42021285450; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=285450.


Assuntos
Autogestão , Telerreabilitação , Zumbido , Adulto , Humanos , Zumbido/terapia , Qualidade de Vida , Autocuidado
7.
Eur Arch Otorhinolaryngol ; 280(11): 4819-4825, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37133498

RESUMO

OBJECTIVES: To estimate the prevalence of tinnitus and hyperacusis in children aged 9-12 years in Flanders, as well as to explore the associations with hearing abilities and listening behaviours. DESIGN: A cross-sectional survey was undertaken in four different Flemish schools. The questionnaire was distributed among 415 children, with a response rate of 97.3%. RESULTS: The prevalence of permanent tinnitus was 10.5% and of hyperacusis was 3.3%. The hyperacusis prevalence was higher in girls (p < .05). Some children reported effects of tinnitus in terms of anxiety (20.1%), sleep (36.5%), and concentration (24.8%). When listening to personal listening devices, 33.5% of the children reported to listen for at least 1 h at 60% or higher of the volume range. Moreover, 54.9% of children stated to never wear hearing protection. CONCLUSIONS: Tinnitus and hyperacusis are prevalent in children aged 9-12 years. Some of these children might be overlooked and, as such, not receiving the required follow-up or counselling. Development of guidelines for the assessment of these auditory symptoms in children would help to determine the prevalence numbers with greater accuracy. Sensibility campaigns for safe listening are warranted, as more than half of the children never use hearing protection.


Assuntos
Zumbido , Feminino , Humanos , Criança , Zumbido/epidemiologia , Zumbido/diagnóstico , Hiperacusia/epidemiologia , Hiperacusia/diagnóstico , Prevalência , Estudos Transversais , Audiometria de Tons Puros
8.
Eur Arch Otorhinolaryngol ; 280(3): 1425-1435, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36224398

RESUMO

BACKGROUND: Hyperacusis is a reduced tolerance to sounds that often co-occurs with tinnitus. Both symptoms have convergent as well as divergent characteristics. Somatic modulation, changes in pitch or loudness during certain movements, is common in patients with a primary complaint of tinnitus. However, thus far, this is not documented in patients with hyperacusis. OBJECTIVES: This study aimed to examine the influence of somatic manoeuvres on the perception of external sounds in patients with a primary complaint of hyperacusis. METHODOLOGY: In this prospective cross-sectional pilot study, 18 patients with a primary complaint of hyperacusis were recruited at the Tinnitus Treatment and Research Center Antwerp (TINTRA). While patients listened to a 1 kHz broadband noise of 30 dB sensation level, six neck manoeuvres (flexion, extension, lateroflexion left/right, traction and compression), three jaw manoeuvres (protrusion, laterotrusion left/right) and one placebo manoeuvre (hand on head) were performed. The primary outcome measure was the change in the perception of the presented sound in terms of loudness and intrusiveness between baseline and each modulation measured by a visual analogue scale (VAS). RESULTS: No overall significant changes were found; however, individual results indicated that five patients presented a clinically relevant change of more than three points out of ten on VAS in terms of hyperacusis after at least one of the executed somatic manoeuvres. CONCLUSIONS: This pilot study did not demonstrate an overall significant change in hyperacusis after somatic manoeuvres but does not rule out the possibility of somatic modulation in some hyperacusis patients. TRIAL REGISTRATION: The protocol of this prospective cross-sectional pilot study was registered on clinicaltrials.gov with registration number NCT04693819.


Assuntos
Hiperacusia , Zumbido , Humanos , Hiperacusia/diagnóstico , Hiperacusia/terapia , Zumbido/diagnóstico , Projetos Piloto , Estudos Transversais , Estudos Prospectivos
9.
BMC Med Educ ; 23(1): 861, 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37957668

RESUMO

BACKGROUND: Peer-assisted learning (PAL) - where students take up a teaching role at an early stage of their training-is widely used in medical curricula. Many qualitative studies have investigated the perceptions and benefits of PAL, but no studies have longitudinally explored how peer teachers experienced their development. This could allow for a better understanding of PAL. In this study, we explored the perceived impact of being a peer teacher on the development of personal and professional competencies as a medical student. METHODS: We longitudinally conducted semi-structured interviews with peer teachers, during their 2-year teaching period in the skills lab at the University of Antwerp and applied descriptive thematic analysis. RESULTS: In total we gathered 47 interviews in 13 peer teachers (9 female, 4 male,. 1-7 interviews each). Peer teachers reported an increase in self-confidence, which gradually transformed into self-efficacy in clinical and teaching skills., Participants told us to be inspired by the previous generation of peer teachers. Their motivation shifted from personal benefits to benefiting others while becoming a role model themselves. The peer teachers illustrated how they developed maturity by integrating different CanMEDS roles. They grew in reflection, changed/transformed an initial mark-driven study drive into more patient-centered ambitions, and started developing a personal style. CONCLUSIONS: Our study suggests that being a peer teacher leads to more self-efficacy, in clinical and teaching skills, to become a role model with as motivation to benefit others and to grow towards a good doctor maturity. Although the task is to teach peers, this opportunity nurtures the practice and integration of various CanMEDS roles, not only that of scholar but also communicator, collaborator and leader, thereby positively influencing their personal and professional development and their identity as a doctor (professional role).


Assuntos
Educação de Graduação em Medicina , Estudantes de Medicina , Humanos , Masculino , Feminino , Currículo , Grupo Associado , Pesquisa Qualitativa , Ensino
10.
J Sleep Res ; 31(6): e13673, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35734809

RESUMO

Mandibular advancement device (MAD) treatment outcome for obstructive sleep apnea (OSA) is variable and patient dependent. A global, clinically applicable predictive model is lacking. Our aim was to combine characteristics obtained during drug-induced sleep endoscopy (DISE), awake nasendoscopy, and computed tomography scan-based computational fluid dynamic (CFD) measurements in one multifactorial model, to explain MAD treatment outcome. A total of 100 patients with OSA were prospectively recruited and treated with a MAD at fixed 75% protrusion. In all, 72 underwent CFD analysis, DISE, and awake nasendoscopy at baseline in a blinded fashion and completed a 3-month follow-up polysomnography with a MAD. Treatment response was defined as a reduction in the apnea-hypopnea index (AHI) of ≥50% and deterioration as an increase of ≥10% during MAD treatment. To cope with missing data, multiple imputation with predictive mean matching was used. Multivariate logistic regression, adjusting for body mass index and baseline AHI, was used to combine all potential predictor variables. The strongest impact concerning odds ratios (ORs) was present for complete concentric palatal collapse (CCCp) during DISE on deterioration (OR 28.88, 95% confidence interval [CI] 1.18-704.35; p = 0.0391), followed by a C-shape versus an oval shape of the soft palate during wakefulness (OR 8.54, 95% CI 1.09-67.23; p = 0.0416) and tongue base collapse during DISE on response (OR 3.29, 95% CI 1.02-10.64; p = 0.0464). Both logistic regression models exhibited excellent and fair predictive accuracy. Our findings suggest DISE to be the most robust examination associated with MAD treatment outcome, with tongue base collapse as a predictor for successful MAD treatment and CCCp as an adverse DISE phenotype.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Placas Oclusais , Vigília , Estudos Prospectivos , Hidrodinâmica , Carbonil Cianeto m-Clorofenil Hidrazona , Endoscopia/métodos , Resultado do Tratamento , Fenótipo , Sono
11.
BMC Infect Dis ; 22(1): 676, 2022 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-35933382

RESUMO

BACKGROUND: The incidence of high-risk human papillomavirus (hrHPV)-driven head and neck squamous cell carcinoma, in particular oropharyngeal cancers (OPC), is increasing in high-resource countries. Patients with HPV-induced cancer respond better to treatment and consequently have lower case-fatality rates than patients with HPV-unrelated OPC. These considerations highlight the importance of reliable and accurate markers to diagnose truly HPV-induced OPC. METHODS: The accuracy of three possible test strategies, i.e. (a) hrHPV DNA PCR (DNA), (b) p16(INK4a) immunohistochemistry (IHC) (p16), and (c) the combination of both tests (considering joint DNA and p16 positivity as positivity criterion), was analysed in tissue samples from 99 Belgian OPC patients enrolled in the HPV-AHEAD study. Presence of HPV E6*I mRNA (mRNA) was considered as the reference, indicating HPV etiology. RESULTS: Ninety-nine OPC patients were included, for which the positivity rates were 36.4%, 34.0% and 28.9% for DNA, p16 and mRNA, respectively. Ninety-five OPC patients had valid test results for all three tests (DNA, p16 and mRNA). Using mRNA status as the reference, DNA testing showed 100% (28/28) sensitivity, and 92.5% (62/67) specificity for the detection of HPV-driven cancer. p16 was 96.4% (27/28) sensitive and equally specific (92.5%; 62/67). The sensitivity and specificity of combined p16 + DNA testing was 96.4% (27/28) and 97.0% (65/67), respectively. In this series, p16 alone and combined p16 + DNA missed 1 in 28 HPV driven cancers, but p16 alone misclassified 5 in 67 non-HPV driven as positive, whereas combined testing would misclassify only 2 in 67. CONCLUSIONS: Single hrHPV DNA PCR and p16(INK4a) IHC are highly sensitive but less specific than using combined testing to diagnose HPV-driven OPC patients. Disease prognostication can be encouraged based on this combined test result.


Assuntos
Carcinoma de Células Escamosas , Neoplasias Orofaríngeas , Infecções por Papillomavirus , Carcinoma de Células Escamosas/diagnóstico , Inibidor p16 de Quinase Dependente de Ciclina/genética , DNA Viral/análise , DNA Viral/genética , Humanos , Imuno-Histoquímica , Neoplasias Orofaríngeas/diagnóstico , Neoplasias Orofaríngeas/patologia , Papillomaviridae/genética , Infecções por Papillomavirus/complicações , Infecções por Papillomavirus/diagnóstico , Reação em Cadeia da Polimerase , RNA Mensageiro/análise
12.
Ear Hear ; 43(6): 1816-1823, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35666538

RESUMO

OBJECTIVES: Transcranial direct current stimulation (tDCS) of the right dorsolateral prefrontal cortex has been hypothesized to reduce tinnitus severity by modifying cortical activity in brain regions associated with the perception of tinnitus. However, individual response to tDCS has proven to be variable. We investigated the feasibility of using random forest classification to predict the response to high-definition (HD) tDCS for tinnitus relief. DESIGN: A retrospective analysis was performed on a dataset consisting of 99 patients with subjective tinnitus receiving six consecutive sessions of HD-tDCS at the Antwerp University Hospital. A baseline assessment consisted of pure-tone audiometry and a set of questionnaires including the Tinnitus Functional Index (TFI), Hospital Anxiety and Depression Scale, and Edinburgh Handedness Inventory. Random forest classification was applied to predict, based on baseline questionnaire scores and hearing levels, whether each individual responded positively to the treatment (defined as a decrease of at least 13 points on the TFI). Further testing of the model was performed on an independent cohort of 32 patients obtained from the tinnitus center at the University of Regensburg. RESULTS: Twenty-four participants responded positively to the HD-tDCS treatment. The random forest classifier predicted treatment response with an accuracy of 85.71% (100% sensitivity, 81.48% specificity), significantly outperforming a more traditional logistic regression approach. Performance of the classifier on an independent cohort was slightly but not significantly above chance level (71.88% accuracy, 66.67% sensitivity, 73.08% specificity). Feature importance analyses revealed that baseline tinnitus severity, co-occurrence of depressive symptoms and handedness were the most important predictors of treatment response. Baseline TFI scores were significantly higher in responders than in nonresponders. CONCLUSIONS: The proposed random forest classifier predicted treatment response with a high accuracy, significantly outperforming a more traditional statistical approach. Machine learning methods to predict treatment response might ultimately be used in a clinical setting to guide targeted treatment recommendations for individual tinnitus patients.


Assuntos
Zumbido , Estimulação Transcraniana por Corrente Contínua , Humanos , Estimulação Transcraniana por Corrente Contínua/métodos , Zumbido/terapia , Estudos de Viabilidade , Estudos Retrospectivos , Inquéritos e Questionários
13.
Am J Respir Crit Care Med ; 203(6): 746-755, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-32970962

RESUMO

Rationale: Approximately one-third of patients with obstructive sleep apnea (OSA) treated with hypoglossal nerve stimulation (HGNS) therapy are incomplete responders, despite careful patient selection based on baseline characteristics and drug-induced sleep endoscopy.Objectives: Here we use polysomnographic endotyping to assess the pathophysiological mechanisms underlying favorable versus incomplete responses to HGNS therapy.Methods: Baseline polysomnography data of the STAR (Stimulation Therapy for Apnea Reduction) trial were included. Raw baseline polysomnographic data from 91/126 patients were available for analysis. Traits-loop gain, arousal threshold, collapsibility, and muscle compensation-were calculated from the baseline polysomnography data according to Sands and colleagues (AJRCCM 2018, SLEEP 2018). Logistic regression assessed apnea-hypopnea index (AHI)-adjusted associations between HGNS response (>50% reduction in AHI to <10/h at 1 yr) and OSA traits.Measurements and Main Results: Overall, HGNS treatment reduced AHI from 30.7 (24.9-39.9) to 8.5 (4.0-19.5) events/h (P < 0.0001; median [quartiles 1-3]); N = 53/91 were responders. In adjusted analysis, a favorable response to therapy was independently associated with higher arousal threshold (odds ratio [95% confidence interval]: 6.76 [2.44-23.3], P = 0.001), greater compensation (odds ratio: 4.22 [1.70-12.55] per SD, P = 0.004), and lower loop gain (in milder collapsibility, per significant interaction, P = 0.003). The higher arousal threshold was evident in responders before adjusted analysis. Predicted responders had an approximately fourfold lower treatment AHI versus predicted nonresponders (4.9 [2.7-8.5] vs. 20.7 [10.9-29.7], P < 0.0001; median [quartiles 1-3]); differences remained significant after cross-validation.Conclusions: Favorable responses to HGNS therapy are associated with the pathophysiological traits causing OSA, particularly a higher arousal threshold. Along with established criteria, individuals with favorable traits could potentially be prioritized for precision HGNS therapy.This analysis was a secondary analysis of the STAR trial registered with clinicaltrials.gov (NCT01161420).


Assuntos
Nervo Hipoglosso/fisiologia , Apneia Obstrutiva do Sono/terapia , Estimulação Elétrica Nervosa Transcutânea/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
Sleep Breath ; 26(4): 1915-1920, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34993758

RESUMO

PURPOSE: Epiglottic collapse is a specific sleep-endoscopic finding that can prove challenging to treat in patients with obstructive sleep apnea (OSA). Its effect on mandibular advancement devices (MAD) remains largely unknown. Therefore, this study assessed whether or not epiglottic collapse affects treatment outcome with MAD. METHODS: Patients with diagnosed OSAD underwent drug-induced sleep endoscopy (DISE) and were treated with a titratable MAD. Two age- and gender-matched controls were selected for every subject with primary epiglottic collapse (i.e., complete closure without involvement of other upper airway structures). Treatment response was defined as a reduction in oxygen desaturation index (ODI) of ≥ 50% following MAD therapy. RESULTS: Of 101 patients who underwent DISE, twenty (20%) showed primary epiglottic collapse (mean [SD]: 17 men; age 49.8 [10.1]; body mass index 28.3 [2.9] kg/m2; apnea-hypopnea index 27.0 [16.9] events/h). There were no significant differences in baseline clinical characteristics between cases and controls. MAD therapy was equally effective in patients with and without epiglottic collapse (mean [SD]; ODI with MAD, 8.7 [7.7] events/h vs. 7.8 [7.5] events/h, P = .62; ΔODI, 53.3 [29.6]% vs. 50.6 [37.7]%, P = .82; responder status, 10/20 vs. 22/40, P = .79). Logistic regression analysis revealed no associations between epiglottic collapse and treatment outcome. CONCLUSION: The presence of epiglottic collapse during DISE does not impair the effectiveness of MAD. Therefore, MAD therapy should be considered in patients with predominant epiglottic collapse.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Masculino , Pessoa de Meia-Idade , Placas Oclusais , Polissonografia , Apneia Obstrutiva do Sono/diagnóstico , Epiglote , Endoscopia , Resultado do Tratamento
15.
Sleep Breath ; 26(4): 1837-1845, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35064876

RESUMO

STUDY OBJECTIVES: The aim of this pilot study was to evaluate the clinical effectiveness of subjective titration versus objectively guided titration during polysomnography (PSG) and drug-induced sleep endoscopy (DISE) in mandibular advancement device (MAD) therapy for patients with obstructive sleep apnea (OSA). METHODS: In this pilot cross-over study, patients underwent three titration procedures in randomized order: (1) subjective titration, (2) PSG-guided titration using a remotely controlled mandibular positioner (RCMP) and (3) DISE-assisted titration using RCMP. After each titration procedure, patients used the MAD for 1 month at the targeted protrusion obtained according to the preceding titration procedure. For each procedure, a follow-up PSG was performed after 1 month of MAD use in order to evaluate the efficacy of the MAD. RESULTS: Ten patients were included in the study. Overall, no significant differences in targeted optimal protrusion compared to maximal comfortable protrusion among the three titration methods were observed. There was no significant difference in reduction in AHI. In this study, PSG titration correctly classified 50% of patients as 'responder'. A higher predictive accuracy was found for DISE titration with a sensitivity of 83.3% and a specificity of 100%. CONCLUSIONS: This pilot randomized cross-over trial showed no differences in optimal mandibular positioning and corresponding efficacy of MAD between subjective titration, DISE titration or PSG titration.


Assuntos
Avanço Mandibular , Humanos , Polissonografia , Placas Oclusais , Projetos Piloto , Estudos Cross-Over , Endoscopia/métodos , Resultado do Tratamento , Sono
16.
Eur Arch Otorhinolaryngol ; 279(10): 4899-4907, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35298688

RESUMO

PURPOSE: To document whether patients with and without hyperacusis differ from each other on demographic, audiological, and clinical characteristics. METHODS: Based on the Hyperacusis Questionnaire's (HQ) cut-off (HQ > 28), a total of 2301 participants were divided into patients with and without hyperacusis. Demographic data, scores on self-reported questionnaires [Tinnitus Functional Index (TFI), Visual Analogue Scale of tinnitus loudness (VASloudness), Hospital Anxiety Depression Scale (HADS)], and audiological parameters were retrospectively analysed to determine differential factors between the two groups. RESULTS: In total, 10.9% of the patients was classified as hyperacusis patients (n = 251). They reported a significant, higher tinnitus severity (mean difference of 19 points on TFI) and mental distress (mean difference of 4 points on the HADS subscales) (p < 0.001) than patients without hyperacusis. Moreover, this group consisted of more women (45% % in hyperacusis group vs. 35% in non-hyperacusis group) and women scored significantly higher on the HQ (p < 0.001) and TFI (p < 0.01). CONCLUSION: Patients with hyperacusis have distinctive characteristics. The presence of hyperacusis in combination with tinnitus can indicate a higher need for psychoeducation. Patients that present themselves with hyperacusis without tinnitus complaints remain a minority, yet might be underdiagnosed. Hence, future studies should disentangle tinnitus from hyperacusis. In clinical practice, greater efforts are required to increase knowledge about hyperacusis as a primary or secondary complaint and to provide individualized treatment for these patients.


Assuntos
Audiologia , Zumbido , Demografia , Feminino , Humanos , Hiperacusia/complicações , Hiperacusia/diagnóstico , Hiperacusia/epidemiologia , Estudos Retrospectivos , Inquéritos e Questionários , Zumbido/diagnóstico , Zumbido/epidemiologia
17.
Eur Arch Otorhinolaryngol ; 279(7): 3301-3307, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34596715

RESUMO

PURPOSE: To evaluate the effects of a single psycho-educational session on tinnitus burden in chronic tinnitus patients. The session is organized at a tertiary referral center for otologic disorders at the University Hospital Antwerp as a group session (maximum of 10-15 patients a time) lasting for approximately 3-4 h. The session focusses on different aspects of tinnitus. METHODS: The current manuscript reports on 96 patients who completed the Tinnitus Functional Index (TFI), Visual Analogue Scale for mean loudness (VAS), Hyperacusis Questionnaire (HQ), and the Hospital Anxiety and Depression Scale (HADS) prior to treatment and at 6-month follow-up. The TFI was chosen as the primary outcome. Paired-samples T tests were performed to evaluate therapy effect at 6-month follow-up. In addition, a logistic regression model revealed baseline TFI/VAS scores and duration of tinnitus as contributing factors to a significant decrease of the TFI. RESULTS: The TFI total score showed a significant decrease (p < 0.001) at the 6-month follow-up time point. At follow-up, 75% of patients reported their tinnitus to be under control not requiring any additional treatment. The logistic regression model showed that patients with higher baseline TFI scores, lower baseline mean VAS loudness ratings, and shorter tinnitus duration were more likely to show clinically significant improvement on the TFI scale. CONCLUSIONS: Tinnitus Retraining Therapy or Cognitive Behavioural Therapy are effective, though very time-consuming and expensive treatments. A single psycho-educational group session was shown to be highly effective in decreasing the tinnitus burden, which increases feasibility and cost-effectiveness. TRIAL REGISTRATION: Not applicable as this is a retrospective reporting of tinnitus outcome in the daily clinical practice, not a clinical trial.


Assuntos
Terapia Cognitivo-Comportamental , Zumbido , Humanos , Estudos Retrospectivos , Inquéritos e Questionários , Fatores de Tempo , Zumbido/psicologia
18.
BMC Med Educ ; 22(1): 431, 2022 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-35659218

RESUMO

BACKGROUND: This study investigates the impact of Peer-Assisted Learning (PAL) in clinical skills on peer teachers' academic scores and competencies; however, controversy remains on this topic, and concrete evidence on its impact lacking. METHODS: We performed a mixed methods study combining a retrospective cohort study with a modified Delphi survey. Peer teachers and Skills Lab faculty members participated in this study. A validated questionnaire, the CanMEDS Competency Based Inventory (CCBI), and group interviews were used to assess the outcomes of PAL. Our results were also triangulated with literature data. RESULTS: In 3 consecutive cohorts of medical students (n = 311), 78 participated in PAL. Peer teachers obtained higher scores from the start of the study, at different timepoints in medical school, and on their final scores compared to all other students. Interestingly their progress followed the same path and magnitude as other well-performing students. However, based on our findings from a modified Delphi survey (CCBI interviews) and a literature review, we found further supporting evidence for a positive impact of PAL on the competencies of physical skills (medical expert), teamwork and leadership (collaborator), lifelong learning (scholar), and for admitting uncertainty/limits (professional) within the CanMEDS roles. CONCLUSIONS: We conclude that higher achieving students are more likely to volunteer for a peer tutoring program; however this does not significantly augment their academic scores as compared to above well-performing non-teaching fellow students. Importantly, our modified Delphi survey indicated which CanMEDS roles were positively impacted by PAL: medical expert, collaborator, scholar and professional.


Assuntos
Educação de Graduação em Medicina , Estudantes de Medicina , Competência Clínica , Educação de Graduação em Medicina/métodos , Humanos , Grupo Associado , Estudos Retrospectivos , Faculdades de Medicina , Ensino
19.
Audiol Neurootol ; 26(2): 61-75, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32653882

RESUMO

Cochlear implants (CI) have increasingly been adopted in older adults with severe to profound sensorineural hearing loss as a result of the growing and aging world population. Consequently, researchers have recently shown great interest in the cost-effectiveness of cochlear implantation and its effect on quality of life (QoL) in older CI users. Therefore, a systematic review and critical evaluation of the available literature on QoL in older adult CI users was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Studies were selected by searching MEDLINE (PubMed) and the Cochrane Library and by checking the reference lists of relevant articles. Inclusion criteria were as follows: (1) the study sample were adults aged 50 years and older with postlingual onset of bilateral severe to profound hearing loss, (2) all subjects received a multi-electrode CI, and (3) QoL was assessed before and after implantation. Out of 1,093 records, 18 articles were accepted for review. Several studies demonstrated significant positive effects of cochlear implantation on QoL in older adults, but high-level evidence-based medicine is lacking. An improvement of QoL was generally reported when using disease-specific instruments, which are designed to detect treatment-specific changes, whereas the outcomes of generic QoL questionnaires, assessing general health states, were rather ambiguous. However, only generic questionnaires would be able to provide calculations of the cost-effectiveness of CI and comparisons across patient populations, diseases, or interventions. Hence, generic and disease-specific QoL instruments are complementary rather than contradictory. In general, older CI users' QoL was assessed using a variety of methods and instruments, which complicated comparisons between studies. There is a need for a standardized, multidimensional, and comprehensive QoL study protocol including all relevant generic and disease-specific instruments to measure and compare QoL, utility, and/or daily life performance in CI users.


Assuntos
Implante Coclear/psicologia , Implantes Cocleares , Perda Auditiva Neurossensorial/cirurgia , Qualidade de Vida/psicologia , Idoso , Feminino , Perda Auditiva Neurossensorial/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários
20.
Sleep Breath ; 25(1): 425-431, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32488573

RESUMO

PURPOSE: Selective hypoglossal nerve stimulation has proven to be a successful treatment option in patients with obstructive sleep apnea. The aim of this pilot study was to investigate if there is a cross-innervation of the hypoglossal nerve in humans and if patients with this phenotype show a different response to hypoglossal nerve stimulation compared to those with ipsilateral-only innervation METHODS: Nineteen patients who previously received a selective hypoglossal nerve stimulation system (Inspire Medical Systems, Golden Valley, USA) were implanted with a nerve integrity system placing electrodes on both sides of the tongue. Tongue motions were recorded one and two months after surgery from transoral and transnasal views. Polysomnography (PSG) was also performed at two months. Electromyogram (EMG) signals and tongue motions after activation were compared with PSG findings. RESULTS: Cross-innervation showed significant correlation with bilateral tongue movement and bilateral tongue base opening, which were associated with better PSG outcomes. CONCLUSION: Cross motor innervation of the hypoglossal nerve occurs in approximately 50% of humans, which is associated with a positive effect on PSG outcomes. Bilateral stimulation of the hypoglossal nerve may be a solution for non-responding patients with pronounced collapse at the soft palate during drug-induced sleep endoscopy.


Assuntos
Nervo Hipoglosso/fisiologia , Palato Mole/inervação , Estimulação Elétrica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Neurônios Motores/fisiologia , Palato Mole/cirurgia , Projetos Piloto , Língua/inervação , Língua/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA