1.
J Radiol Prot ; 44(2)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38834035

RESUMO

Nuclear medicine (NM) professionals are potentially exposed to high doses of ionising radiation, particularly in the skin of the hands. Ring dosimeters are used by the workers to ensure extremity doses are kept below the legal limits. However, ring dosimeters are often susceptible to large uncertainties, so it is difficult to ensure a correct measurement using the traditional occupational monitoring methods. An alternative solution is to calculate the absorbed dose by using Monte Carlo simulations. This method could reduce the uncertainty in dose calculation if the exact positions of the worker and the radiation source are represented in these simulations. In this study we present a set of computer vision and artificial intelligence algorithms that allow us to track the exact position of unshielded syringes and the hands of NM workers. We showcase a possible hardware configuration to acquire the necessary input data for the algorithms. And finally, we assess the tracking confidence of our software. The tracking accuracy achieved for the syringe detection was 57% and for the hand detection 98%.


Assuntos
Algoritmos , Medicina Nuclear , Exposição Ocupacional , Humanos , Exposição Ocupacional/análise , Mãos/efeitos da radiação , Método de Monte Carlo , Inteligência Artificial , Radiometria/métodos , Seringas
2.
J Radiol Prot ; 43(1)2023 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-36720155

RESUMO

The International Commission on Radiation Units and Measurements (ICRU) proposed a new set of operational quantities for radiation protection for external radiation in its Report Committee 26 (ICRU95). The new proposal aims to improve the coherence between the operational quantities and the definitions of the protection quantities in the recommendations of the International Commission on Radiological Protection set out in 2007 (Ann. ICRP37). It is expected that this change in operational quantities will impact current dosimeter designs. Although for many photon energies, the conversion coefficients from physical field quantities to the new operational quantities will change relatively little, for radiation fields with low energy photon components, such as medical x-ray applications, there will be a significant decrease in the values of the conversion coefficients. This means that the numerical values of the new operational quantities will be much lower for the same radiation field. These values will be closer to the effective dose, but this change can still cause confusion for medical staff. It is important to examine the effect of the new set of dose conversion coefficients on the personal dose in realistic radiation fields. We performed a study to assess the effect of changing the definition of the operational quantity, personal dose equivalent (Hp), in realistic radiation fields in interventional radiology (IR) workplaces. The x-ray tube kilovoltage peak (kVp) in IR ranges between 60 and 120 kV. The medical staff is exposed to the scattered photons which have a wide range of energies depending on the beam configuration and the patient size. The objective of this study is to 'quantitatively' estimate the impact of implementing the new ICRU quantities of Report 95 in IR radiation fields using Monte Carlo simulations. Simulations of 560 different configurations in IR were performed using MCNPX to calculate fluence binned per energy and angle of incidence.HpandHp(10)were then calculated for each configuration using dose conversion coefficients from fluence given by ICRU Reports 95 and 57, respectively. The results show that the mean of the ratio,Hp(10)/Hp, is 1.6 for all simulated scenarios. This reduction will correct the current overestimation of the effective dose and should result in better compliance with the dose limits in IR. However, it may also have negative consequences on the safety culture among the medical staff. Special care will be needed when interpreting these lower doses.


Assuntos
Proteção Radiológica , Radiologia Intervencionista , Humanos , Doses de Radiação , Simulação por Computador , Proteção Radiológica/métodos , Fótons , Método de Monte Carlo , Radiometria/métodos
3.
J Radiol Prot ; 42(3)2022 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-35654011

RESUMO

The lens of the eye can be damaged by ionising radiation, so individuals whose eyes are exposed to radiation during their work may need to protect their eyes from exposure. Lead glasses are widely available, but there are questions about their efficiency in providing eye protection. In this study, Monte Carlo simulations are used to assess the efficiency of lead glasses in protecting the sensitive volume of the eye lens. Two designs currently available for interventional cardiologists are a wraparound (WA) style and ones with flat frontal lenses with side shielding. These designs were considered together with four modifications that would impact upon their efficiency: changing the lead equivalent thickness, adding lead to the frames, elongating the frontal lenses, and adding a closing shield to the bottom rim. For the eye closest to the source, standard models of lead glasses only decrease the radiation reaching the most sensitive region of the eye lens by 22% or less. Varying the lead thickness between 0.4 mm and 0.75 mm had little influence on the protection provided in the simulation of clinical use, neither did adding lead to the frames. Improved shielding was obtained by elongating the frontal lens, which could reduce radiation reaching the eye lens by up to 76%. Glasses with lenses that had a rim at the base, extending towards the face of the user, also provided better shielding than current models, decreasing the dose by up to 80%. In conclusion, elongating the frontal lens of lead glasses, especially of the WA design, could provide a three-fold increase in shielding efficiency and this is still valid for lenses with 0.4 mm lead equivalence.


Assuntos
Cardiologistas , Cristalino , Exposição Ocupacional , Proteção Radiológica , Dispositivos de Proteção dos Olhos , Humanos , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Radiologia Intervencionista
4.
J Radiol Prot ; 40(1): 215-224, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31703213

RESUMO

The reduction in the occupational dose limit of the eye lens has created the need for optimising eye protection and dose assessment, in particular for interventional clinicians. Lead glasses are one of the protection tools for shielding the eyes, but assessing the eye lens dose when these are in place remains challenging. In this study, we evaluated the impact of the position of H p (3) dosemeters on the estimated eye lens dose when lead glasses are used in interventional settings. Using the Monte Carlo method (MCNPX), an interventional cardiology setup was simulated for two models of lead glasses, five beam projections and two patient access routes. H p (3) dosemeters were placed at several positions on the operator and the obtained dose was compared to the dose to the sensitive part of the eye lens (H lens). Furthermore, to reproduce an experimental setup, a reference dosemeter, H p (3)ref, was placed on the surface of the eye. The dose measured by H p (3)ref was, on average, only 60% of H lens. Dosemeters placed on the glasses, under their shielding, underestimated H lens for all parameters considered, by from 10% up to 90%. Conversely, dosemeters placed on the head or on the glasses, over their shielding, overestimated H lens, on average, up to 60%. The presence or lack of side shielding in lead glasses affected mostly dosemeters placed on the forehead, at the left side. Results suggest that both use of a correction factor of 0.5 to account for the presence of lead glasses in doses measured outside their shielding and placing an eye lens dosemeter immediately beneath the lenses of lead glasses may lead to the underestimation of the eye lens dose. Most suitable positions for eye lens dose assessment were on the skin, unshielded by the glasses or close to the eye, with no correction to the dose measured.


Assuntos
Dispositivos de Proteção dos Olhos , Cristalino/efeitos da radiação , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Radiologia Intervencionista , Humanos , Chumbo , Método de Monte Carlo , Doses de Radiação , Dosímetros de Radiação
5.
J Radiol Prot ; 39(1): 97-112, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30523896

RESUMO

In fluoroscopy guided interventional procedures, workers use protective garments and often two personal dosemeters, the readings of which are used for the estimation of the effective dose; whereas the dosemeter above the protection can be used for the estimation of the equivalent dose of the lens of the eye. When a protective apron is worn the scattered field that reaches the dosemeter is different from the case where no protection is used; this study analyses the changes in the response of seven passive and eight active personal dosemeters (APDs) when they are placed above a lead or lead equivalent garment for S-Cs and x-ray diagnostic qualities. Monte Carlo simulations are used to support the experimental results. It is found that for passive dosemeters, the influence on the dosemeter's response to the lead or lead equivalent was within the range 15%-38% for the x-ray qualities. This effect is smaller, of the order of 10%, when lead-free garments are used, and much smaller, within 1%-10%, for most of the APDs used in the study. From these results it is concluded that when comparing passive and active dosemeter measurements worn above the protection, a difference of 20%-40% is expected. The effect is small when deriving the effective dose from double dosimetry algorithms, but it can be of major importance when eye lens monitoring is based on the use of the dosemeter worn above the protection.


Assuntos
Cateterismo Cardíaco , Roupa de Proteção , Dosímetros de Radiação , Proteção Radiológica/métodos , Radiografia Intervencionista , Humanos
6.
J Radiol Prot ; 38(2): 702-715, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29633720

RESUMO

Considering that occupational exposure in medicine is a matter of growing concern, active personal dosimeters (APDs) are also increasingly being used in different fields of application of ionising radiation in medicine. An extensive survey to collect relevant information regarding the use of APDs in medical imaging applications of ionising radiation was organised by the EURADOS (European Radiation Dosimetry Group) Working Group 12. The objective was to collect data about the use of APDs and to identify the basic problems in the use of APDs in hospitals. APDs are most frequently used in interventional radiology and cardiology departments (54%), in nuclear medicine (29%), and in radiotherapy (12%). Most types of APDs use silicon diodes as the detector; however, in many cases their calibration is not given proper attention, as radiation beam qualities in which they are calibrated differ significantly from those in which they are actually used. The survey revealed problems related to the use of APDs, including their reliability in pulsed x-ray fields that are widely used in hospitals. Guidance from regulatory authorities and professional organisations on the testing and calibration of APDs used in hospital would likely improve the situation.


Assuntos
Hospitais , Exposição Ocupacional/prevenção & controle , Dosímetros de Radiação , Exposição à Radiação/prevenção & controle , Europa (Continente) , Humanos , Autorrelato
7.
Phys Med ; : 103392, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38862325

RESUMO

The International Commission on Radiological Protection (ICRP), recently expressed concern that "a shortage of investment in training, education, research, and infrastructure seen in many sectors and countries may compromise society's ability to properly manage radiation risks" and in 2022 announced the "Vancouver call for action to strengthen expertise in radiological protection worldwide". As representatives of organisations in formal relations with ICRP, we decided to promote this position paper to declare and emphasise that strengthening the expertise in radiological protection is a collective priority for all of us.

8.
Phys Med Biol ; 68(3)2023 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-36595254

RESUMO

Objective. Microdosimetry offers a fast tool for radiation quality (RQ) verification to be implemented in treatment planning systems in proton therapy based on variable LET or RBE to move forward from the use of a fixed RBE of 1.1. It is known that the RBE of protons can increase up to 50% higher than that value in the last few millimetres of their range. Microdosimetry can be performed both experimentally and by means of Monte Carlo (MC) simulations. This paper has the aim of comparing the two approaches.Approach. Experimental measurements have been performed using a miniaturized Tissue equivalent proportional counter developed at the Legnaro National Laboratories of the Italian National Institute for Nuclear Physics with the aim of being used as RQ monitors for high intensity beams. MC simulations have been performed using the microdosimetric extension of TOPAS which provides optimized parameters and scorers for this application.Main results. Simulations were compared with experimental microdosimetric spectra in terms of shape of the spectra and their average values. Moreover, the latter have been investigated as possible estimators of LET obtained with the same MC code. The shape of the spectra is in general consistent with the experimental distributions and the average values of the distributions in both cases can predict the RQ increase with depth.Significance. This study aims at the comparison of microdosimetric spectra obtained from both experimental measurements and the microdosimetric extension of TOPAS in the same radiation field.


Assuntos
Terapia com Prótons , Monitoramento de Radiação , Radiometria/métodos , Benchmarking , Prótons , Método de Monte Carlo , Eficiência Biológica Relativa
9.
Phys Med ; 107: 102543, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36780792

RESUMO

PURPOSE: To evaluate the effectiveness of currently available radioprotective (RP) devices in reducing the dose to interventional cardiology staff, especially to the eye lens and brain. METHODS: The performances of five RP devices (masks, caps, patient drapes, staff lead and lead-free aprons and Zero-Gravity (ZG) suspended radiation protection system) were assessed by means of Monte Carlo (MC) simulations. A geometry representative of an interventional cardiology setup was modelled and several configurations, including beam projections and staff distance from the source, were investigated. In addition, measurements on phantoms were performed for masks and drapes. RESULTS: An average dose reduction of 65% and 25% to the eyes and the brain respectively was obtained for the masks by MC simulations but a strong influence of the design was observed. The cap effectiveness for the brain ranges on average between 13% and 37%. Nevertheless, it was shown that only some upper parts of the brain were protected. There was no significant difference between the effectiveness of lead and lead-free aprons. Of all the devices, the ZG system offered the highest protection to the brain and eye lens and a protection level comparable to the apron for the organs normally covered. CONCLUSION: All investigated devices showed potential for dose reduction to specific organs. However, for masks, caps and drapes, it strongly depends on the design, exposure conditions and staff position. Therefore, for a clinical use, it is recommended to evaluate their effectiveness in the planned conditions of use.


Assuntos
Cardiologia , Cristalino , Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Proteção Radiológica/métodos , Radiometria/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Cardiologia/métodos , Exposição Ocupacional/prevenção & controle , Radiologia Intervencionista/métodos
10.
Phys Med Biol ; 68(6)2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36821866

RESUMO

Objective. The lateral dose fall-off in proton pencil beam scanning (PBS) technique remains the preferred choice for sparing adjacent organs at risk as opposed to the distal edge due to the proton range uncertainties and potentially high relative biological effectiveness. However, because of the substantial spot size along with the scattering in the air and in the patient, the lateral penumbra in PBS can be degraded. Combining PBS with an aperture can result in a sharper dose fall-off, particularly for shallow targets.Approach. The aim of this work was to characterize the radiation fields produced by collimated and uncollimated 100 and 140 MeV proton beams, using Monte Carlo simulations and measurements with a MiniPIX-Timepix detector. The dose and the linear energy transfer (LET) were then coupled with publishedin silicobiophysical models to elucidate the potential biological effects of collimated and uncollimated fields.Main results. Combining an aperture with PBS reduced the absorbed dose in the lateral fall-off and out-of-field by 60%. However, the results also showed that the absolute frequency-averaged LET (LETF) values increased by a maximum of 3.5 keVµm-1in collimated relative to uncollimated fields, while the dose-averaged LET (LETD) increased by a maximum of 7 keVµm-1. Despite the higher LET values produced by collimated fields, the predicted DNA damage yields remained lower, owing to the large dose reduction.Significance. This work demonstrated the dosimetric advantages of combining an aperture with PBS coupled with lower DNA damage induction. A methodology for calculating dose in water derived from measurements with a silicon-based detector was also presented. This work is the first to demonstrate experimentally the increase in LET caused by combining PBS with aperture, and to assess the potential DNA damage which is the initial step in the cascade of events leading to the majority of radiation-induced biological effects.


Assuntos
Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Método de Monte Carlo
11.
Artigo em Inglês | MEDLINE | ID: mdl-36669811

RESUMO

Several trials have attempted to identify sources of inter-laboratory variability in comet assay results, aiming at achieving more equal responses. Ionising radiation induces a defined level of DNA single-strand breaks (per dose/base pairs) and is used as a reference when comparing comet results but relies on accurately determined radiation doses. In this ring test we studied the significance of dose calibrations and comet assay protocol differences, with the object of identifying causes of variability and how to deal with them. Eight participating laboratories, using either x-ray or gamma radiation units, measured dose rates using alanine pellet dosimeters that were subsequently sent to a specialised laboratory for analysis. We found substantial deviations between calibrated and nominal (uncalibrated) dose rates, with up to 46% difference comparing highest and lowest values. Three additional dosimetry systems were employed in some laboratories: thermoluminescence detectors and two aqueous chemical dosimeters. Fricke's and Benzoic Acid dosimetry solutions gave reliable quantitative dose estimations using local equipment. Mononuclear cells from fresh human blood or mammalian cell lines were irradiated locally with calibrated (alanine) radiation doses and analysed for DNA damage using a standardised comet assay protocol and a lab-specific protocol. The dose response of eight laboratories, calculated against calibrated radiation doses, was linear with slope variance CV= 29% with the lab-specific protocol, reduced to CV= 16% with the standard protocol. Variation between laboratories indicate post-irradiation repair differences. Intra-laboratory variation was very low judging from the dose response of 8 donors (CV=4%). Electrophoresis conditions were different in the lab-specific protocols explaining some dose response variations which were reduced by systematic corrections for electrophoresis conditions. The study shows that comet assay data obtained in different laboratories can be compared quantitatively using calibrated radiation doses and that systematic corrections for electrophoresis conditions are useful.


Assuntos
Dano ao DNA , Radiação Ionizante , Animais , Humanos , Ensaio Cometa/métodos , Calibragem , Raios gama , Relação Dose-Resposta à Radiação , Mamíferos
12.
Radiat Prot Dosimetry ; 199(15-16): 1689-1695, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819353

RESUMO

Following the publication of the joint The International Commissions on Radiation Units and Measurements (ICRU) and on Radiological Protection (ICRP) report on new operational quantities for radiation protection, the European Dosimetry Group (EURADOS) have carried out an initial evaluation. The EURADOS report analyses the impact that the new quantities will have on: radiation protection practice; calibration and reference fields; European and national regulation; international standards and, especially, dosemeter and instrument design. The task group included experienced scientists drawn from across the various EURADOS working groups.


Assuntos
Monitoramento de Radiação , Proteção Radiológica , Radiometria , Dosímetros de Radiação , Calibragem , Padrões de Referência , Doses de Radiação
13.
Radiat Prot Dosimetry ; 198(6): 349-357, 2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35482286

RESUMO

This study aimed to evaluate the relationship between the brain absorbed dose and personal dosimetry readings in interventional cardiologists. Interventional procedures were replicated using Monte Carlo simulations (MCNP 6) with anthropomorphic phantoms representing both operator and patient. Absorbed doses were evaluated for 10 predefined regions of the operator's brain as well as for dosemeters at chest and neck level. One beam quality (HVL = 6.2 mm Al) and nine beam projections were considered. A significant bias in the laterality of brain dose was found with doses at the left side of the brain being up to 2.8 times higher compared with the right. The correlation between brain dose and dosemeter reading was found to be dependent on beam projection. Yet, a generalized conversion factor (brain dose normalized by Hp(10)), averaged over all considered beam projections, could be proposed for (retrospective) brain dose estimation from routinely measured dosimetry data.


Assuntos
Exposição Ocupacional , Radiologia Intervencionista , Humanos , Método de Monte Carlo , Exposição Ocupacional/análise , Imagens de Fantasmas , Doses de Radiação , Radiometria/métodos , Estudos Retrospectivos
14.
Int J Occup Med Environ Health ; 35(5): 549-560, 2022 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-35446304

RESUMO

OBJECTIVES: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap can lead to ambiguous results, a detailed study was performed. MATERIAL AND METHODS: The effectiveness of a lead free cap in reducing the doses to the skin was assessed in clinic by performing measurements with thermoluminescent dosimeters attached inside and outside the cap first during individual coronary angiography (CA) or CA/percutaneous transluminal coronary angioplasty (CA/PTCA) procedures and then cumulated during few procedures of the same type. In order to investigate the effect of the cap on reducing the doses to the brain additional measurements were performed with a male Alderson Rando and polymethyl methacrylate (PMMA) phantoms representing the physician and the patient, respectively for different projections. The brain dose per procedure, annual and cumulated during entire working practice were estimated for both cases working with and without the cap. RESULTS: The dose reduction factor (RF) for the skin (the quotient of doses outside and inside the cap) vary from 1.1 up to 4.0 in clinical conditions; on average 2.3-fold reduction is observed in the most exposed left temple. The RFs determined for the part of the head covered by the cap range from 1.4 to 1.8 while for the brain from 1.0 to 1.1 depending on the projection. The estimated annual brain dose for interventional cardiologist performing yearly 550 CA/PTCA procedures without any protective shields is 7.2 mGy and it is reduced with the lead free cap by an average factor of 1.1. CONCLUSIONS: The study results proved the considerable effectiveness of lead free cap to protect the skin but very limited to protect the brain. Int J Occup Med Environ Health. 2022;35(5):549-60.


Assuntos
Cardiologistas , Exposição Ocupacional , Angiografia Coronária , Hemodinâmica , Humanos , Masculino , Exposição Ocupacional/prevenção & controle , Polimetil Metacrilato , Doses de Radiação , Radiação Ionizante
15.
Phys Med Biol ; 67(1)2022 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-34933289

RESUMO

Objective. Treatment planning based on computer simulations wasproposed to account for the increased relative biological effectiveness (RBE) of proton radiotherapy beams near to the edges of the irradiated volume. Since silicon detectors could be used to validate the results of these simulations, it is important to explore the limitations of this comparison.Approach. Microdosimetric measurements with a MicroPlus Bridge V2 silicon detector (thickness = 10µm) were performed along the Bragg peak of a clinical proton beam. The lineal energy distributions, the dose-mean values, and the RBE calculated with a biological weighting function were compared with PHITS simulations (microdosimetric target = 1µm water sphere), and published clonogenic survivalin vitroRBE data for the V79 cell line. The effect of the silicon-to-water conversion was also investigated by comparing three different methodologies (conversion based on a single value, novel bin-to-bin conversions based on SRIM and PSTAR).Main results. Mainly due to differences in the microdosimetric targets, the experimental dose-mean lineal energy and RBE values at the distal edge were respectively up to 53% and 28% lower than the simulated ones. Furthermore, the methodology chosen for the silicon-to-water conversion was proven to affect the dose-mean lineal energy and the RBE10up to 32% and 11% respectively. The best methodology to compensate for this underestimation was the bin-to-bin silicon-to-water conversion based on PSTAR.Significance. This work represents the first comparison between PHITS-simulated lineal energy distributions in water targets and corresponding experimental spectra measured with silicon detectors. Furthermore, the effect of the silicon-to-water conversion on the RBE was explored for the first time. The proposed methodology based on the PSTAR bin-to-bin conversion appears to provide superior results with respect to commonly used single scaling factors and is recommended for future studies.


Assuntos
Terapia com Prótons , Método de Monte Carlo , Terapia com Prótons/métodos , Prótons , Silício , Água
16.
Phys Med ; 93: 29-37, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34920380

RESUMO

INTRODUCTION: Interventional radiology procedures are associated with high skin dose exposure. The 2013/59/EURATOM Directive establishes that the equipment used for interventional radiology must have a device or a feature informing the practitioner of relevant parameters for assessing patient dose at the end of the procedure. This work presents and validates PyMCGPU-IR, a patient dose monitoring tool for interventional cardiology and radiology procedures based on MC-GPU. MC-GPU is a freely available Monte Carlo (MC) code of photon transport in a voxelized geometry which uses the computational power of commodity Graphics Processing Unit cards (GPU) to accelerate calculations. METHODOLOGIES: PyMCGPU-IR was validated against two different experimental set-ups. The first one consisted of skin dose measurements for different beam angulations on an adult Rando Alderson anthropomorphic phantom. The second consisted of organ dose measurements in three clinical procedures using the Rando Alderson phantom. RESULTS: The results obtained for the skin dose measurements show differences below 6%. For the clinical procedures the differences are within 20% for most cases. CONCLUSIONS: PyMCGPU-IR offers both, high performance and accuracy for dose assessment when compared with skin and organ dose measurements. It also allows the calculation of dose values at specific positions and organs, the dose distribution and the location of the maximum doses per organ. In addition, PyMCGPU-IR overcomes the time limitations of CPU-based MC codes.


Assuntos
Fótons , Radiologia Intervencionista , Adulto , Humanos , Método de Monte Carlo , Imagens de Fantasmas
17.
Phys Med Biol ; 66(23)2021 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-34710862

RESUMO

728 simulated microdosimetric lineal energy spectra (26 different ions between1H and238U, 28 energy points from 1 to 1000 MeV/n) were used in combination with a recently-developed biological weighting function (Parisiet al2020Phys. Med. Biol.1361-6560) and 571 publishedin vitroclonogenic survival curves in order to: (1) assess prediction intervals for thein silicoresults by deriving an empirical indication of the experimental uncertainty from the dispersion in thein vitrohamster lung fibroblast (V79) data used for the development of the biophysical model; (2) explore the possibility of modeling the relative biological effectiveness (RBE) of the 10% clonogenic survival of asynchronized normoxic repair-competent mammalian cell lines other than the one used for the development of the model (V79); (3) investigate the predictive power of the model through a comparison betweenin silicoresults andin vitrodata for 10 ions not used for the development of the model. At first, different strategies for the assessment of thein silicoprediction intervals were compared. The possible sources of uncertainty responsible for the dispersion in thein vitrodata were also shortly reviewed. Secondly, also because of the relevant scatter in thein vitrodata, no statistically-relevant differences were found between the RBE10of the investigated different asynchronized normoxic repair-competent mammalian cell lines. The only exception (Chinese Hamster peritoneal fibroblasts, B14FAF28), is likely due to the limited dataset (allin vitroion data were extracted from a single publication), systematic differences in the linear energy transfer calculations for the employed very-heavy ions, and the use of reference photon survival curves extracted from a different publication. Finally, thein silicopredictions for the 10 ions not used for the model development were in good agreement with the correspondingin vitrodata.


Assuntos
Íons Pesados , Transferência Linear de Energia , Animais , Linhagem Celular , Sobrevivência Celular , Cricetinae , Íons , Mamíferos , Eficiência Biológica Relativa
18.
Med Phys ; 37(5): 2082-91, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20527541

RESUMO

PURPOSE: The purpose of this study was to compare and validate three methods to simulate radiographic image detectors with the Monte Carlo software MCNP/MCNPX in a time efficient way. METHODS: The first detector model was the standard semideterministic radiography tally, which has been used in previous image simulation studies. Next to the radiography tally two alternative stochastic detector models were developed: A perfect energy integrating detector and a detector based on the energy absorbed in the detector material. Validation of three image detector models was performed by comparing calculated scatter-to-primary ratios (SPRs) with the published and experimentally acquired SPR values. RESULTS: For mammographic applications, SPRs computed with the radiography tally were up to 44% larger than the published results, while the SPRs computed with the perfect energy integrating detectors and the blur-free absorbed energy detector model were, on the average, 0.3% (ranging from -3% to 3%) and 0.4% (ranging from -5% to 5%) lower, respectively. For general radiography applications, the radiography tally overestimated the measured SPR by as much as 46%. The SPRs calculated with the perfect energy integrating detectors were, on the average, 4.7% (ranging from -5.3% to -4%) lower than the measured SPRs, whereas for the blur-free absorbed energy detector model, the calculated SPRs were, on the average, 1.3% (ranging from -0.1% to 2.4%) larger than the measured SPRs. CONCLUSIONS: For mammographic applications, both the perfect energy integrating detector model and the blur-free energy absorbing detector model can be used to simulate image detectors, whereas for conventional x-ray imaging using higher energies, the blur-free energy absorbing detector model is the most appropriate image detector model. The radiography tally overestimates the scattered part and should therefore not be used to simulate radiographic image detectors.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Método de Monte Carlo , Radiografia/métodos , Espalhamento de Radiação , Doses de Radiação , Reprodutibilidade dos Testes
19.
Med Phys ; 37(5): 2092-100, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20527542

RESUMO

PURPOSE: The purpose of this study is to develop a computer model to simulate the image acquisition for two computed radiography (CR) imaging systems used for neonatal chest imaging: (1) The Agfa ADC Compact, a flying spot reader with powder phosphor image plates (MD 40.0); and (2) the Agfa DX-S, a line-scanning CR reader with needle crystal phosphor image plates (HD 5.0). The model was then applied to compare the image quality of the two CR imaging systems. METHODS: Monte Carlo techniques were used to simulate the transport of primary and scattered x rays in digital x-ray systems. The output of the Monte Carlo program was an image representing the energy absorbed in the detector material. This image was then modified using physical characteristics of the CR imaging systems to account for the signal intensity variations due to the heel effect along the anode-cathode axis, the spatial resolution characteristics of the imaging system, and the various sources of image noise. The simulation was performed for typical acquisition parameters of neonatal chest x-ray examinations. To evaluate the computer model, the authors compared the threshold-contrast detectability in simulated and experimentally acquired images of a contrast-detail phantom. Threshold-contrast curves were computed using a commercially available scoring program. RESULTS: The threshold-contrast curves of the simulated and experimentally acquired images show good agreement; for the two CR systems, 93% of the threshold diameters calculated from the simulated images fell within the confidence intervals of the threshold diameter calculated from the experimentally assessed images. Moreover, the superiority of needle based CR plates for neonatal imaging was confirmed. CONCLUSIONS: The good agreement between simulated and experimental acquired results indicates that the computer model is accurate.


Assuntos
Modelos Teóricos , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Humanos , Recém-Nascido , Método de Monte Carlo , Imagens de Fantasmas , Radiografia Torácica , Software
20.
Health Phys ; 118(1): 85-95, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31764423

RESUMO

To establish diagnostic reference levels (DRLs) and investigate deterministic and stochastic risks in pediatric interventional cardiology (IC) procedures. Exposure parameters were retrospectively reviewed for 373 patients treated between May 2016 and November 2018 at a single specialized hospital. Weight specific DRLs were derived for pediatric IC procedures. Additionally, peak skin dose (Dskin,max) was measured using thermoluminescent dosimeters for a sample of 7 diagnostic and 43 therapeutic procedures. Finally, using PCXMC software, organ doses were computed and the risk of exposure-induced cancer death (REID) was estimated using the risk models of the Biological Effects of Ionizing Radiation VII committee. DRLs for ventricular septal defect (VSD) occlusions, lacking in the literature, in terms of air kerma at patient entrance reference point (388 and 629 mGy) and total air kerma-area product (28 and 61 Gycm) were proposed for patients weight-groups 5 - < 15 kg and 15 - < 30 kg, respectively. The mean (range) Dskin,max was 15 (1-30) mGy and 94 (1-491) mGy for diagnostic and therapeutic procedures, respectively. Meanwhile, VSD occlusion involved the highest organ doses where the lungs, liver, stomach, and breasts mean doses were 57, 37, 6, and 10 mGy, respectively, and the associated REID were 0.5% and 0.3% in female and male patients, respectively. DRLs were proposed for pediatric IC procedures; these will help optimize patient exposure. Dskin,max values were lower than the 2 Gy threshold for skin injuries. Pediatric organ doses and the REID were the highest during VSD occlusion and may be critical for repetitive procedures.


Assuntos
Cardiologia/normas , Fluoroscopia/normas , Cardiopatias Congênitas/diagnóstico , Órgãos em Risco/efeitos da radiação , Radiografia Intervencionista/normas , Adolescente , Peso Corporal , Cateterismo Cardíaco/métodos , Cardiologia/métodos , Criança , Pré-Escolar , Feminino , Fluoroscopia/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Recém-Nascido , Masculino , Doses de Radiação , Monitoramento de Radiação , Radiografia Intervencionista/métodos , Valores de Referência , Estudos Retrospectivos