Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 170
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
World J Urol ; 42(1): 145, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478094

RESUMO

INTRODUCTION AND OBJECTIVES: Medical device companies have introduced new TFL machines, including Soltive (Olympus, Japan), Fiber Dust (Quanta System, Italy), and TFLDrive (Coloplast, France). The primary objective of this study is to compare our initial clinical experiences with TFL using those devices. Through this historical comparison of Thulium Fiber Laser systems for stone lithotripsy, we aim to advance our understanding and approach toward achieving safe and effective TFL parameters. MATERIALS AND METHODS: The data for this comparative analysis were extracted from three distinct prospective series that were previously published, outlining our initial clinical experience with the Soltive (Olympus, Japan), FiberDust laser (Quanta System, Italy), and TFLDrive laser (Coloplast, France). Parameters such as stone size, stone density, laser-on time (LOT), and laser settings were meticulously recorded. Additionally, we assessed critical variables such as ablation speed (expressed in mm3/s) and Joules/mm3 for each lithotripsy procedure. RESULTS: A total of 149 patients were enrolled in this study. Among them, 120 patients were subjected to analysis concerning renal stones. Statistically significant differences were observed in the median (IQR) stone volume: 650 (127-6027) mm3 for TFLDrive, 1800 (682.8-2760) mm3 for Soltive, and 1125 (294-4000) mm3 for FiberDust (p: 0.007); while there were no differences regarding stone density among the groups. Significant variations were identified in median (IQR) pulse energy, frequency, and total power. The Soltive group exhibited lower energy levels (0.3 J vs. 0.6 J, p: 0.002) but significantly higher pulse frequency (100 Hz vs. 17.5 Hz, p: 0.003) and total power (24 W vs. 11W, p: 0.001) compared to the other groups. Laser-on time showed no substantial differences across all three groups. Additionally, a statistically significant difference was observed in median J/mm3, with the TFLDrive group using higher values (24 J/mm3, p: 0.001), while the Soltive group demonstrated a higher median ablation speed of 1.16 mm3/s (p: 0.001). The overall complication rate remained low for all groups, with comparable stone-free rates. CONCLUSION: By reducing pulsed frequency, we improved laser efficiency, but smaller volumes lead to decreased efficiency due to increased retropulsion and fragment movement. Further studies are needed to identify and establish the appropriate laser settings for this new technology.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Túlio/uso terapêutico , Litotripsia a Laser/métodos , Cálculos Renais/cirurgia
2.
World J Urol ; 42(1): 388, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985297

RESUMO

PURPOSE: We assessed the impact of the one-year endourological society fellowship program (ESFP) on the achievement of optimal surgical outcomes (OSO) in stone patients treated with ureteroscopy (URS). MATERIALS AND METHODS: We identified 303 stone patients treated with URS from January 2018 to June 2022 by five experienced surgeons (ES). Of those, two attended ESFP. OSO was defined as the presence of residual fragments ≤ 4 mm at 1-month post-operative imaging (Ultrasound + X - Ray or CT scan). Descriptive statistics explored patients' characteristics and the rate of OSO according to the attendance of ESFP. Uni- and multivariate logistic regression analyses (UVA and MVA) tested the impact of stone characteristics, surgical data, ESFP, and imaging technique on the rate of OSO. The LOWESS curve explored the graphical association between stone size and the multivariable-adjusted probability of OSO in the two groups of surgeons. RESULTS: Of 303 patients, 208 (69%) were treated by the two surgeons who attended ESFP. OSO was achieved in 66% and 52% of patients treated by ES with and without ESFP, respectively (p = 0.01). At UVA, ESFP (OR = 1.78; 95% CI = 1.09-2.90), stone diameter (OR = 0.92; 95% CI = 0.88-0.96), stone location (kidney vs. ureter; OR = 0.34; 95% CI = 0.21-0.58), imaging technique (CT scan vs. Ultrasound + X-Ray; OR = 0.28; 95% CI = 0.16-0.47) predicted OSO achievement (all p < 0.05). At MVA analyses, ESFP was associated with OSO (OR = 2.24; 95% CI = 1.29-3.88; p < 0.05), along with the other aforementioned variables. The LOWESS curve showed that the greater the stone size, the greater the difference in OSO in the two groups of surgeons. CONCLUSIONS: ESFP positively affects OSO achievement after URS, especially in patients with a high stone burden.


Assuntos
Bolsas de Estudo , Cálculos Ureterais , Ureteroscopia , Urologia , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Urologia/educação , Resultado do Tratamento , Estudos Retrospectivos , Cálculos Ureterais/cirurgia , Cálculos Ureterais/diagnóstico por imagem , Cálculos Renais/cirurgia , Cálculos Renais/diagnóstico por imagem , Adulto , Sociedades Médicas , Idoso
3.
World J Urol ; 42(1): 298, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38709327

RESUMO

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Assuntos
Desenho de Equipamento , Rim , Iluminação , Ureteroscópios , Modelos Anatômicos , Humanos
4.
World J Urol ; 42(1): 362, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38814457

RESUMO

OBJECTIVE: To evaluate long-term surgical and functional outcomes of cystinuric patients exclusively treated with Ureteroscopy (URS). METHODS: Data from patients treated for cystine stones at a single academic center were retrospectively analyzed. The management protocol consisted of (i) treating symptomatic or > 7 mm stones, (ii) multi-staged URS for voluminous stones, (iii) referring patients to a dedicated nephrological clinic. The eGFR was calculated according to the MDRD formula. CKD category was assessed according to the NKF classification. Relevant CKD was defined as CKD category ≥ 3a. Descriptive statistics were used to analyze the cohort data. RESULTS: Data from 46 cystinuric patients treated with 332 URS were available. Median age at diagnosis and at first URS in our center were 18 and 32 years, respectively. Median follow-up was 101 months. Median number of URS and recurrences per patient were 6 and 2, respectively. The median interval between the first and the last available creatinine level was 64 months. Median first and last eGFR were 72 and 74 mL/min, respectively. Overall, 83% of patients had stable or improved renal function within the study period. Ureteral stricture occurred in 3 (6.5%) patients. CONCLUSIONS: Cystinuria requires intensive endoscopic management. Most patients treated with URS have stable or improved renal function within a long-term follow-up. CKD is a not neglectable event that potentially occurs at an early stage of life. Current findings should be considered for the surgical management of cystinuric patients.


Assuntos
Cistinúria , Centros de Atenção Terciária , Ureteroscopia , Humanos , Masculino , Estudos Retrospectivos , Adulto , Feminino , Adolescente , Cistinúria/complicações , Adulto Jovem , Resultado do Tratamento , Fatores de Tempo , Cálculos Renais/cirurgia , Pessoa de Meia-Idade , Criança
5.
World J Urol ; 42(1): 355, 2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38796790

RESUMO

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Assuntos
Desenho de Equipamento , Iluminação , Ureteroscópios , Ureteroscopia , Luz , Humanos , Solução Salina , Cor
6.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520528

RESUMO

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Assuntos
Iluminação , Ureteroscópios , Humanos , Desenho de Equipamento , Urologistas , Equipamentos Descartáveis , Ureteroscopia
7.
World J Urol ; 42(1): 240, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630158

RESUMO

PURPOSE: To evaluate the impact of ureteroscope position within renal cavities as well as different locations of the tip of the ureteral access sheath (UAS) on fluid dynamics during retrograde intrarenal surgery (RIRS). MATERIALS AND METHODS: A prospective observational clinical study was performed. Measurements with a flexible ureteroscope placed in the upper, middle and lower calyces were obtained with the tip of the UAS placed either 2 cm below the pyelo-ureteric junction (PUJ), or at the level of the iliac crest. RESULTS: 74 patients were included. The outflow rates from the middle and upper calyxes were statistically significantly higher compared to the lower calyx, both with the UAS close to the pyelo-ureteric junction and at the iliac crest. When the UAS was withdrawn and positioned at the level of the iliac crest, a significant decrease in outflow rates from the upper (40.1 ± 4.3 ml/min vs 35.8 ± 4.1 ml/min) and middle calyces (40.6 ± 4.0 ml/min vs 36.8 ± 4.6 ml/min) and an increase in the outflow from the lower calyx (28.5 ± 3.3 ml/min vs 33.7 ± 5.7 ml/min) were noted. CONCLUSIONS: Our study showed that higher fluid outflow rates are observed from upper and middle calyces compared to lower calyx. This was true when the UAS was positioned 2 cm below the PUJ and at the iliac crest. Significant worsening of fluid dynamics from upper and middle calyces was observed when the UAS was placed distally at the level of the iliac crest. While the difference was statistically significant, the absolute change was not significant. In contrast, for lower calyces, a statistically significant improvement was documented.


Assuntos
Ureter , Ureteroscópios , Humanos , Hidrodinâmica , Rim , Endoscopia , Ureter/cirurgia
8.
World J Urol ; 42(1): 163, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488927

RESUMO

INTRODUCTION: Due to the radiation exposure for the urology staff during endourology, our aim was to evaluate the trends of radiation protection in the operation room by endourologists from European centers and to estimate their annual radiation. METHODS: We conducted a multicenter study involving experienced endourologists from different European centers to evaluate whether the protection and threshold doses recommended by the International Commission on Radiation Protection (ICRP) were being followed. A 36-question survey was completed on the use of fluoroscopy and radiation protection. Annual prospective data from chest, extremities, and eye dosimeters were collected during a 4-year period (2017-2020). RESULTS: Ten endourologists participated. Most surgeons use lead aprons and thyroid shield (9/10 and 10/10), while leaded gloves and caps are rarely used (2/10 both). Six out of ten surgeons wear leaded glasses. There is widespread use of personal chest dosimeters under the apron (9/10), and only 5/10 use a wrist or ring dosimeter and 4 use an eye dosimeter. Two endourologists use the ALARA protocol. The use of ultrasound and fluoroscopy during PCNL puncture was reported by 8 surgeons. The mean number of PCNL and URS per year was 30.9 (SD 19.9) and 147 (SD 151.9). The mean chest radiation was 1.35 mSv per year and 0.007 mSv per procedure. Mean radiation exposure per year in the eyes and extremities was 1.63 and 11.5 mSv. CONCLUSIONS: Endourologists did not exceed the threshold doses for radiation exposure to the chest, extremities and lens. Furthermore, the ALARA protocol manages to reduce radiation exposure.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Estudos Prospectivos , Exposição Ocupacional/prevenção & controle , Fluoroscopia/efeitos adversos , Exposição à Radiação/prevenção & controle , Doses de Radiação
9.
Hum Reprod ; 38(8): 1464-1472, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37322566

RESUMO

STUDY QUESTION: Is it possible to identify a reliable marker of successful sperm retrieval (+SR) in men with idiopathic non-obstructive azoospermia (iNOA) undergoing microdissection testicular sperm extraction (mTESE)? SUMMARY ANSWER: A higher likelihood of +SR during mTESE is observed in men with iNOA and lower preoperative serum anti-Müllerian hormone (AMH) levels, with good predictive accuracy achieved using an AMH threshold of <4 ng/ml. WHAT IS KNOWN ALREADY: AMH has been previously linked to +SR in men with iNOA undergoing mTESE prior to ART. STUDY DESIGN, SIZE, DURATION: A multi-centre cross-sectional study was carried out with a cohort of 117 men with iNOA undergoing mTESE at three tertiary-referral centres. PARTICIPANTS/MATERIALS, SETTING, METHODS: Data from 117 consecutive white-European men with iNOA presenting for primary couple's infertility associated with a pure male factor at three centres were analysed. Descriptive statistics was applied to compare patients with negative (-SR) versus +SR at mTESE. Multivariate logistic regression models were fitted to predict +SR at mTESE, after adjusting for possible confounders. Diagnostic accuracy of the factors associated with +SR was assessed. Decision curve analyses were used to display the clinical benefit. MAIN RESULTS AND THE ROLE OF CHANCE: Overall, 60 (51.3%) men had an -SR and 57 (48.7%) had a +SR at mTESE. Patients with +SR had lower levels of baseline AMH (P = 0.005) and higher levels of estradiol (E2) (P = 0.01). At multivariate logistic regression analysis, lower levels of AMH (odds ratio: 0.79; 95% CI: 0.64-0.93, P = 0.03) were associated with +SR at mTESE, after adjusting for possible confounders (e.g. age, mean testicular volume, FSH, and E2). A threshold of AMH <4 ng/ml achieved the highest accuracy for +SR at mTESE, with an AUC of 70.3% (95% CI: 59.8-80.7). Decision curve analysis displayed the net clinical benefit of using an AMH <4 ng/ml threshold. LIMITATIONS, REASONS FOR CAUTION: There is a need for external validation in even larger cohorts, across different centres and ethnicities. Systematic reviews and meta-analysis to provide high level of evidence are lacking in the context of AMH and SR rates in men with iNOA. WIDER IMPLICATIONS OF THE FINDINGS: Current findings suggest that slightly more than one in two men with iNOA had -SR at mTESE. Overall, men with iNOA with lower levels of AMH had a significantly higher percentage of successful SR at surgery. A threshold of <4 ng/ml for circulating AMH ensured satisfactory sensitivity, specificity, and positive predictive values in the context of +SR at mTESE. STUDY FUNDING/COMPETING INTEREST(S): This work was supported by voluntary donations from the Urological Research Institute (URI). All authors declare no conflict of interest. TRIAL REGISTRATION NUMBER: N/A.


Assuntos
Azoospermia , Humanos , Masculino , Hormônio Antimülleriano , Estudos Transversais , Estudos Retrospectivos , Sêmen , Recuperação Espermática
10.
World J Urol ; 41(12): 3807-3815, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37924335

RESUMO

INTRODUCTION: Shared decision making (SDM) in surgical specialties was demonstrated to diminish decisional regret, decisional anxiety and decisional conflict. Urolithiasis guidelines do not explicit patient preference to choose treatment. The aim of this review article was to perform a systematic evaluation of published evidence regarding SDM in urinary stone treatment. METHODS: A systematic review in accordance PRISMA checklist was conducted using the MEDLINE (PubMed) database. Inclusion criteria were studies that evaluated stone treatment preferences. Reviews, editorials, case reports and video abstracts were excluded. ROBUST checklist was used to assess quality of the studies. RESULTS: 188 articles were obtained. After applying the predefined selection criteria, seven articles were included for final analysis. Six out of seven studies were questionnaires that propose clinical scenarios and treatment alternatives. The last study was a patient preference trial. A general trend among included studies showed a patient preference towards the least invasive option (SWL over URS). The main reasons to choose one treatment over the other were stone-free rates, risk of complications and invasiveness. DISCUSSION: This review provides an overview of the patients' preferences towards stone treatment in small- and medium-sized stones. There was a clear preference towards the least invasive management strategy. The main reason was less invasiveness. This is opposed to the global trends of performing more ureteroscopies and less SWL. Physicians played a pivotal role in counselling patients. SDM should be encouraged and improved. The main limitation of this study is the characteristics of the included studies.


Assuntos
Litotripsia , Cálculos Urinários , Urolitíase , Humanos , Preferência do Paciente , Urolitíase/terapia , Cálculos Urinários/terapia , Ureteroscopia
11.
World J Urol ; 41(9): 2541-2547, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37528287

RESUMO

PURPOSE: Aim of this study was to evaluate the effect of intravenous Y27632 (a ROK inhibitor) on intra-ureteral pressures and on blood pressure in an in vivo rat model for unilateral partial ureteral obstruction (PUO). METHODS: 15 Male Sprague Dawley rats were used. Under isofluran anesthesia, saline was continuously infused via polyethylene (PE)-10 catheters inserted in the ureters beneath the kidney pelvis. Left psoas muscle was sutured around the distal left ureter to create a partial obstruction. Carotid artery and femoral vein were cannulated with PE catheters for registration of mean arterial blood pressure (MAP) and for administration of drugs. Left and right ureter pressures and MAP were simultaneously recorded. Y27632 (0.03 and 0.1 mg/kg each n = 6-7) was given intravenously. T-test was used for comparisons. RESULTS: Spontaneous peristaltic pressure waves were recorded at baseline for both ureters. After the obstruction, Y27632 reduced maximum pressure (MaxP) by 10.5 ± 1.9% (0.03 mg/kg; p = 0.004) and 29.1 ± 4.8% (0.1 mg/kg; p < 0.001), minimum pressure (MinP) by 5.2 ± 2.3% (0.03 mg/kg; p = 0.02) and 12.2 ± 3.4% (0.1 mg/kg; p = 0.009), the area under the curve (AUC) by 7.8 ± 2.4% (0.03 mg/kg; p = 0.008) and 16.5 ± 3.7% (0.1 mg/kg;p = 0.007), the waves amplitude by 23.4 ± 11.3% (0.03 mg/kg; p = 0.098) and 38.7 ± 7.5% (0.1 mg/kg; p < 0.001), with no effect on contraction frequency. During simultaneous recordings from the normal ureter at the investigated doses, Y27632 reduced MaxP, MinP, AUC and waves amplitude by 1-7%. The MAP was reduced by 12.5 ± 5.3% (0.03 mg/kg; p = 0.07) and 15.8 ± 1.8% (0.1 mg/kg; p < 0.001). CONCLUSIONS: Y27632 decreased intra-ureteral pressures of a partially obstructed ureter with limited effect on blood pressure in an animal model of unilateral PUO.


Assuntos
Ureter , Obstrução Ureteral , Ratos , Masculino , Animais , Obstrução Ureteral/complicações , Quinases Associadas a rho , Ratos Sprague-Dawley
12.
World J Urol ; 41(10): 2823-2831, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37587366

RESUMO

PURPOSE: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the novel pulsed thulium:YAG (p-Tm:YAG), including analysis of stone particle size after lithotripsy. METHODS: Human urinary stones of 7 different compositions were subjected to in vitro lithotripsy using a p-Tm:YAG laser with 270 µm silica core fibers (Thulio®, Dornier MedTech GmbH®, Wessling, Germany). A cumulative energy of 1000 J was applied to each stone using one of three laser settings: 0.1 J × 100 Hz, 0.4 J × 25 Hz and 2.0 J × 5 Hz (average power 10 W). After lithotripsy, larger remnant fragments were separated from stone dust using a previously described method depending on the floating ability of dust particles. Fragments and dust samples were then passed through laboratory sieves to evaluate stone particle count according to a semiquantitative analysis relying on a previous definition of stone dust (i.e., stone particles ≤ 250 µm). RESULTS: The p-Tm:YAG laser was able to produce stone dust from lithotripsy up to measured smallest mesh size of 63 µm in all seven stone composition types. Notably, all dust samples from all seven stone types and with all three laser settings had high counts of particles in the size range agreeing with the definition stone dust, i.e., ≤ 250 µm. CONCLUSION: This is the first study in the literature proving the p-Tm:YAG laser capable of dusting all prevailing human urinary stone compositions, with production of dust particles ≤ 250 µm. These findings are pivotal for the broader future implementation of the p-Tm:YAG in clinical routine.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Urinários , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Poeira , Litotripsia a Laser/métodos , Cálculos Urinários/terapia
13.
World J Urol ; 41(1): 229-233, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36445371

RESUMO

OBJECTIVE: To analyze the pattern of speaker activity related to both flexible ureteroscopy (fURS) and percutaneous nephrolithotomy (PCNL) during plenary sessions at the main (endo)urological international meetings over the last 10 years. METHODS: We reviewed the meeting programs of the main endourological international meetings (EAU, AUA, WCE, and SIU) during 2011-2019. We detected all invited speakers at plenary sessions regarding fURS or PCNL. The proportion of fURS and PCNL talks was evaluated yearly during the study period. In order to analyze plenary session speaker composition, we estimated and compared the mean number of talks per speaker according to surgical technique. We also analyzed possible differences in age distribution according to the topic of the talk as well as the presence of young (i.e., < 45 years) speakers. Data were analyzed using descriptive statistics. RESULTS: During the last 10 years, a total of 498 plenary talks were found. Of those, 260 (52.2%), 211 (42.4%), and 27 (5.4%) discussed PCNL, fURS, or both, respectively. PCNL was more frequently discussed at the beginning and the end of the study period. Mean [SD] number of talks per speaker was higher for PCNL (2.9 [3.4] vs 1.6 [1.4], p < 0.001), meaning that a wider variety of speakers was invited to give fURS talks. Speakers discussing fURS were younger (median [interquartile range, IQR] age 48 [44-56] vs 52 [47-60] years, p < 0.001), and a higher proportion of young speakers was observed in the fURS group (26% vs 15% p < 0.001). PCNL speakers were more commonly discussing fURS than fURS speakers discussing PCNL (23% vs 17%, p = 0.43). CONCLUSIONS: We found a wider variety of speakers at fURS plenary sessions as compared to PCNL ones. It is easier and quicker to become an internationally recognized expert in the field of fURS rather than PCNL. PCNL speakers were able to master fURS more frequently than the other way around.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Humanos , Pessoa de Meia-Idade , Nefrolitotomia Percutânea/métodos , Ureteroscopia/métodos , Cálculos Renais/cirurgia , Ureteroscópios
14.
World J Urol ; 41(12): 3723-3730, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37831156

RESUMO

BACKGROUND: The novel pulsed thulium:yttrium-aluminum-garnet (p-Tm:YAG) laser was recently introduced. Current studies present promising p-Tm:YAG ablation efficiency, although all are based on non-human stone models or with unknown stone composition. The present study aimed to evaluate p-Tm:YAG ablation efficiency for stone dust from human urinary stones of known compositions. METHODS: Calcium oxalate monohydrate (COM) and uric acid (UA) stones were subjected to lithotripsy in vitro using a p-Tm:YAG laser generator (Thulio®, Dornier MedTech GmbH, Germany). 200 J was applied at 0.1 J × 100 Hz, 0.4 J × 25 Hz or 2.0 J × 5 Hz (average 10W). Ablated stone dust mass was calculated from weight difference between pre-lithotripsy stone and post-lithotripsy fragments > 250 µm. Estimated ablated volume was calculated using prior known stone densities (COM: 2.04 mg/mm3, UA: 1.55 mg/mm3). RESULTS: Mean ablation mass efficiency was 0.04, 0.06, 0.07 mg/J (COM) and 0.04, 0.05, 0.06 mg/J (UA) for each laser setting, respectively. This translated to 0.021, 0.029, 0.034 mm3/J (COM) and 0.026, 0.030, 0.039 mm3/J (UA). Mean energy consumption was 26, 18, 17 J/mg (COM) and 32, 23, 17 J/mg (UA). This translated to 53, 37, 34 J/mm3 (COM) and 50, 36, 26 J/mm3 (UA). There were no statistically significant differences for laser settings or stone types (all p > 0.05). CONCLUSION: To our knowledge, this is the first study showing ablation efficiency of the p-Tm:YAG laser for stone dust from human urinary stones of known compositions. The p-Tm:YAG seems to ablate COM and UA equally well, with no statistically significant differences between differing laser settings.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Nefrolitíase , Cálculos Urinários , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Litotripsia a Laser/métodos , Cálculos Urinários/terapia , Oxalato de Cálcio , Hólmio
15.
World J Urol ; 41(11): 3301-3308, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37682286

RESUMO

INTRODUCTION: Several preclinical studies about a novel pulsed-thulium:yttrium-aluminum-garnet (p-Tm:YAG) device have been published, demonstrating its possible clinical relevance. METHODS: We systematically reviewed the reality and expectations for this new p-Tm:YAG technology. A PubMed, Scopus and Embase search were performed. All relevant studies and data identified in the bibliographic search were selected, categorized, and summarized. RESULTS: Tm:YAG is a solid state diode-pumped laser that emits at a wavelength of 2013 nm, in the infrared spectrum. Despite being close to the Ho:YAG emission wavelength (2120 nm), Tm:YAG is much closer to the water absorption peak and has higher absorption coefficient in liquid water. At present, there very few evaluations of the commercially available p-Tm:YAG devices. There is a lack of information on how the technical aspects, functionality and pulse mechanism can be maximized for clinical utility. Available preclinical studies suggest that p-Tm:YAG laser may potentially increase the ablated stone weight as compared to Ho:YAG under specific condition and similar laser parameters, showing lower retropulsion as well. Regarding laser safety, a preclinical study observed similar absolute temperature and cumulative equivalent minutes at 43° C as compared to Ho:YAG. Finally, laser-associated soft-tissue damage was assessed at histological level, showing similar extent of alterations due to coagulation and necrosis when compared with the other clinically relevant lasers. CONCLUSIONS: The p-Tm:YAG appears to be a potential alternative to the Ho:YAG and TFL according to these preliminary laboratory data. Due to its novelty, further studies are needed to broaden our understanding of its functioning and clinical applicability.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Temperatura , Água , Hólmio
16.
Int Braz J Urol ; 49(5): 646-647, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37351906

RESUMO

INTRODUCTION: The management of urolithiasis ectopic pelvic kidneys (EPK) can be challenging because of the aberrant anatomy (1-4). We demonstrate the step-by-step technique of the laparoscopic approach for treating urolithiasis in EPK. PATIENTS AND METHODS: Three men with EPK (2 left, 1 right) underwent laparoscopic pyelolithotomy through a transperitoneal approach. After establishing the pneumoperitoneum, the parietal peritoneum was opened at the parietal colic sulcus and the bowel displaced medially. The kidney was identified in the retroperitoneum and the renal pelvis exposed after removal of the perirenal adipose tissue. The renal pelvis was opened, and the stones were identified and retrieved with forceps in 2 cases and with a flexible nephroscope in 1 case. The renal pelvis was closed with a 3/0 running barbed suture. A DJ stent was placed in all patients. RESULTS: For the first time, a laparoscopic technique for treating stones in the ectopic kidney is demonstrated in detail. Mean patient age was 52.6 years (44-58). The mean stone size was 22.3 mm (20-24 mm). Stones were in the renal pelvis in 2 cases and in the inferior calyx in 1 case. Mean operative time was 146 minutes (135-155 min). Mean estimated blood loss was 116 ml (60-140 ml). No complications were observed. The mean hospital stay was 3 days. The DJ stents were removed after 3 weeks. All patients were stone free at the postoperative CT scan with a mean follow-up of 3.3 months (1-6 months). CONCLUSIONS: Laparoscopic pyelolithotomy can be an effective and reproducible minimally invasive technique for treating urolithiasis in EPK.


Assuntos
Cálculos Renais , Laparoscopia , Urolitíase , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Cálculos Renais/cirurgia , Nefrotomia/métodos , Rim/cirurgia , Pelve Renal/cirurgia , Laparoscopia/métodos , Urolitíase/cirurgia
17.
Reprod Biomed Online ; 44(1): 119-126, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34815158

RESUMO

RESEARCH QUESTION: To evaluate the correlation between clinical and hormonal parameters and comorbidity burden in Caucasian women presenting for fertility treatment. DESIGN: Monocentric cross-sectional study including a cohort of 3163 Caucasian women seeking medical care for fertility treatment. All patients underwent centralized laboratory testing for hormonal assessment. Complete clinical and laboratory data from the entire cohort were retrospectively analysed. Comorbidity burden score was assessed by the Charlson Comorbidity Index (CCI; categorized as 0 versus 1 versus ≥2). RESULTS: Descriptive statistics and regression models tested the associations between clinical and laboratory parameters and CCI. Among the entire cohort of patients, a CCI = 0 was found in 2977 women (94.1%), and CCI = 1 and CCI ≥2 were found in 113 (3.6%) and 73 (2.3%) patients, respectively. Age (P = 0.009), gravidity (P = 0.001), anti-Müllerian hormone (AMH, P < 0.001) and TSH (P = 0.003) values were significantly different among CCI groups. In regression models, age at presentation and AMH emerged as independent indicators of CCI ≥ 1. Age at presentation <36 years (odds ratio [OR] 1.742, 95% confidence interval [CI] 1.284-2.364) and an AMH concentration ≤2.3 ng/ml (OR 1.864, 95% CI 1.29-2.69) were the most informative cut-off values for CCI ≥ 1 in the study population. CONCLUSIONS: A younger age at presentation and lower AMH concentrations are significant independent indicators of decreased general health in women requiring clinical evaluation for fertility treatment. As observed for sperm parameters in men, AMH might serve as a proxy of women's general health status.


Assuntos
Hormônio Antimülleriano , Fertilidade , Estudos Transversais , Feminino , Nível de Saúde , Humanos , Masculino , Estudos Retrospectivos
18.
World J Urol ; 40(1): 251-256, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34424373

RESUMO

OBJECTIVES: To assess whether the introduction of single use flexibles ureteroscopes (su-fURS) at our high-volume centre had an advantageous impact on the turn-over and breakage rates of reusable fURS (re-fURS). METHODS: We analysed re-fURS number of usages and breakages at our centre between February 2015 and December 2018. We recorded the number of usages for analysed scope between the first usage until a breakage requiring reconditioning. Usage count was restarted following each reconditioning episode. Since su-fURS (Lithovue, Boston Scientific, USA) were introduced at our center in September 2016, we had the chance to compare different re-fURS life cycles according to both su-fURS availability and usage intensity (i.e., number of su-fURS used during each re-fURS life cycle). We then explored the relationship between su-fURS usage intensity and reusable scope survival (i.e., number of utilizations before any breakage requiring reconditioning) using locally weighted scatterplot smoothing (LOWESS) approach. RESULTS: Five different re-fURSs were employed at our centre, for a total of 1820 usages and 40 breakages requiring reconditioning. The overall mean (SD) number of usages before breaking was 40 (22). After su-fURS introduction, mean (SD) re-fURS number of usages increased from 35 (22) to 49 (20), (+ 40%, p = 0.02). The relationship between su-fURS usage intensity and reusable scopes survival showed a linear survival increase after 10 or more su-fURS scopes were used per life cycle. CONCLUSIONS: The life cycle of re-fURS increased by 40% after the introduction of su-fURS. Ten or more used su-fURS per life cycle were associated with increased re-fURS survival.


Assuntos
Equipamentos Descartáveis , Reutilização de Equipamento , Ureteroscópios , Hospitais com Alto Volume de Atendimentos , Humanos , Estudos Retrospectivos
19.
Curr Opin Urol ; 32(3): 324-329, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35266913

RESUMO

PURPOSE OF REVIEW: Moses effect is an inherent physical principle of Ho:YAG laser functioning. Moses Technology is a pulse modulation modality of Ho:YAG laser, which became commercially available for the treatment of two urological conditions: urinary stones and benign prostatic obstruction. The purpose of this narrative review is to distinguish between Moses effect and Moses Technology, as well as to summarize the latest evidence on Moses Technology and its main application in the urological field. RECENT FINDINGS: During laboratory lithotripsy, Moses Technology seems to reduce stone retropulsion and determine higher ablation volume compared with regular lithotripsy. However, this technology presents similar characteristics to long pulse Ho:YAG laser, and several studies showed no significant difference between Moses Technology and standard lasers. When used in prostate enucleation, Moses Technology promises to reduce operating time by increasing the efficiency of prostate resection and improve the hemostasis. Moreover, some studies state that it is possible to reduce the HoLEP morbidity. Despite this, the clinical impact of the time reduction remains uncertain and different studies either present relevant limitations or are burdened by significant bias. SUMMARY: Although Moses effect has been extensively described and characterized, and several studies have been published on the usage of Moses Technology for both laser lithotripsy and laser enucleation of the prostate with Holmium YAG, solid clinical evidence on the real improvement of surgical outcomes is still missing.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Alumínio , Feminino , Hólmio , Humanos , Lasers de Estado Sólido/efeitos adversos , Litotripsia a Laser/efeitos adversos , Masculino , Ítrio
20.
BMC Med Inform Decis Mak ; 22(1): 35, 2022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35135530

RESUMO

INTRODUCTION: For clinical decision-making, an estimate of remaining lifetime is needed to assess benefit against harm of a treatment during the remaining lifespan. Here, we describe how to predict life expectancy based on age, Charlson Comorbidity Index (CCI) and a Drug Comorbidity Index (DCI), whilst also considering potential future changes in CCI and DCI using population-based data on Swedish men. METHODS: Simulations based on annual updates of vital status, CCI and DCI were used to estimate life expectancy at population level. The probabilities of these transitions were determined from generalised linear models using prostate cancer-free comparison men in PCBaSe Sweden. A simulation was performed for each combination of age, CCI, and DCI. Survival curves were created and compared to observed survival. Life expectancy was then calculated as the area under the simulated survival curve. RESULTS: There was good agreement between observed and simulated survival curves for most ages and comorbidities, except for younger men. With increasing age and comorbidity, there was a decrease in life expectancy. Cross-validation based on six regions in Sweden also showed that simulated and observed survival was similar. CONCLUSION: Our proposed method provides an alternative statistical approach to estimate life expectancy at population level based on age and comorbidity assessed by routinely collected information on diagnoses and filled prescriptions available in nationwide health care registers.


Assuntos
Expectativa de Vida , Neoplasias da Próstata , Tomada de Decisão Clínica , Comorbidade , Humanos , Masculino , Neoplasias da Próstata/terapia , Suécia/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA