RESUMO
BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.
Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Flutter Atrial/etiologia , Sistema de Registros , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , RecidivaRESUMO
AIMS: Pulmonary vein isolation (PVI) is a well-established strategy for the treatment of paroxysmal atrial fibrillation (PAF). Despite randomized controlled trials and real-world data showing the promise of pulsed-field ablation (PFA) for this treatment, long-term efficacy and safety data demonstrating single-procedure outcomes off antiarrhythmic drugs remain limited. The aim of the FARA-Freedom Study was to evaluate the long-term efficacy and safety of PFA using the pentaspline catheter for PAF. METHODS AND RESULTS: FARA-Freedom, a prospective, non-randomized, multicentre study, enrolled patients with PAF undergoing de novo PVI with PFA, who were followed for 12 months with weekly transtelephonic monitoring and a 72-h Holter ECG at 6 and 12 months. The primary safety endpoint was a composite of device- or procedure-related serious adverse events out to 7 days post-ablation and PV stenosis or atrioesophageal (AE) fistula out to 12 months. Treatment success is a composite of acute PVI and chronic success, which includes freedom from any documented atrial tachyarrhythmia longer than 30â s, use of antiarrhythmic drugs or cardioversion after a 3-month blanking period, or use of amiodarone or repeat ablation at any time. The study enrolled 179 PAF patients (62 ± 10â years, 39% female) at 13 centres. At the index procedure, all PVs were successfully isolated with the pentaspline PFA catheter. Procedure and left atrial dwell times, with a 20-min waiting period, were 71.9 ± 17.6 and 41.0 ± 13.3â min, respectively. Fluoroscopy time was 11.5 ± 7.4â min. Notably, monitoring compliance was high, with 88.4 and 90.3% with weekly events and 72-h Holter monitors, respectively. Freedom from the composite primary effectiveness endpoint was 66.6%, and 41 patients had atrial tachyarrhythmia recurrence, mostly recurrent atrial fibrillation (31 patients). The composite safety endpoint occurred in two patients (1.1%), one tamponade and one transient ischaemic attack. There was no coronary spasm, PV stenosis, or AE fistula. There were four cases of transient phrenic nerve palsy, but all resolved during the index procedure. CONCLUSION: In this prospective, non-randomized, multicentre study, PVI using a pentaspline PFA catheter was effective in treating PAF patients despite rigourous endpoint definitions and high monitoring compliance and demonstrated favourable safety. REGISTRATION: Clinical Trials.gov Identifier: NCT05072964 (sponsor: Boston Scientific Corporation).
Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula , Veias Pulmonares , Feminino , Humanos , Masculino , Antiarrítmicos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Constrição Patológica/cirurgia , Fístula/cirurgia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Taquicardia/cirurgia , Resultado do Tratamento , Pessoa de Meia-Idade , IdosoRESUMO
AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3â mm; an inter-tag distance ≤6â mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72â h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Masculino , Feminino , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Imageamento Tridimensional , Cateteres Cardíacos , Fatores de Tempo , Desenho de Equipamento , Estudos Prospectivos , RecidivaRESUMO
AIMS: Previous clinical studies on pulmonary vein isolation (PVI) with a radiofrequency balloon (RFB) reported safe and effective procedures using conventional ablation settings with 20/60â s RF delivery via posterior/anterior (PST/ANT) electrodes. The latest evidence suggests that reducing the application time to 15â s (s) on the posterior wall when facing the oesophageal region is as effective as applying 20â s. To prospectively assess whether reducing RF time on PST/ANT segments to 15/45â s can ensure sufficient quality of lesion metrics and compare the new shortened ablation settings with the conventional one in terms of safety, and effectiveness at 1-year. METHODS AND RESULTS: A total of 641 patients from seven European centres were enrolled in a collaborative registry, with 374 in the conventional RF delivery group and 267 in the shortened RF delivery group. Procedural outcomes, lesion metrics, and safety profiles were assessed and compared between the groups. Freedom of any atrial tachycarrythmias at one year was 85.4% and 88.2% in the SHRT and CONV groups, respectively. The shortened RF delivery strategy was associated with significantly shorter procedure times (median 63.5 vs. 96.5â min, P < 0.001) and shortened fluoroscopy exposure (median 10.0 vs. 14.0â min, P < 0.001) compared to conventional delivery. Efficacy metrics, including first-pass isolation rates and time to isolation, were comparable between groups. Shortened RF delivery was associated with a lower incidence of procedural complications (1.4% vs. 5.3%, P = 0.04) and optimized thermal characteristics. CONCLUSION: Analyses from the COLLABORATE registry demonstrate that shortening RF energy delivery times to 15/45â s (PST/ANT) during PVI with the RFB resulted in comparable freedom from recurrent atrial tachyarrhythmia compared to conventional delivery times with comparable efficiency and safety.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Sistema de Registros , Humanos , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Feminino , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Resultado do Tratamento , Idoso , Europa (Continente) , Fatores de Tempo , Estudos Prospectivos , Cateteres Cardíacos , Recidiva , Fatores de RiscoRESUMO
AIMS: Although electrical activity of the normal human heart is well characterized by the electrocardiogram, detailed insights into within-subject and between-subject variations of ventricular activation and recovery by noninvasive electroanatomic mapping are lacking. We characterized human epicardial activation and recovery within and between normal subjects using non-invasive electrocardiographic imaging (ECGI) as a basis to better understand pathology. METHODS AND RESULTS: Epicardial activation and recovery were assessed by ECGI in 22 normal subjects, 4 subjects with bundle branch block (BBB) and 4 with long-QT syndrome (LQTS). We compared characteristics between the ventricles [left ventricle (LV) and right ventricle (RV)], sexes, and age groups (<50/≥50years). Pearson's correlation coefficient (CC) was used for within-subject and between-subject comparisons. Age of normal subjects averaged 49 ± 14 years, 6/22 were male, and no structural/electrical heart disease was present. The average activation time was longer in LV than in RV, but not different by sex or age. Electrical recovery was similar for the ventricles, but started earlier and was on average shorter in males. Median CCs of between-subject comparisons of the ECG signals, activation, and recovery patterns were 0.61, 0.32, and 0.19, respectively. Within-subject beat-to-beat comparisons yielded higher CCs (0.98, 0.89, and 0.82, respectively). Activation and/or recovery patterns of patients with BBB or LQTS contrasted significantly with those found in the normal population. CONCLUSION: Activation and recovery patterns vary profoundly between normal subjects, but are stable individually beat to beat, with a male preponderance to shorter recovery. Individual characterization by ECGI at baseline serves as reference to better understand the emergence, progression, and treatment of electrical heart disease.
Assuntos
Potenciais de Ação , Bloqueio de Ramo , Eletrocardiografia , Síndrome do QT Longo , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/diagnóstico , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/diagnóstico , Frequência Cardíaca , Valor Preditivo dos Testes , Idoso , Estudos de Casos e Controles , Fatores de Tempo , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Fatores Etários , Mapeamento EpicárdicoRESUMO
AIMS: Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. METHODS AND RESULTS: This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. CONCLUSION: Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Resultado do Tratamento , Incidência , Fatores de Risco , Fístula Esofágica/epidemiologia , Fístula Esofágica/etiologia , Fístula Esofágica/diagnóstico , Prognóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodosRESUMO
BACKGROUND: We aimed to assess the prevalence of ischemic brain lesions detected by magnetic resonance imaging and their association with cognitive function 3 months after first-time ablation using continuous oral anticoagulation in patients with paroxysmal atrial fibrillation (AF). METHODS: We performed a prespecified analysis of the AXAFA-AFNET 5 trial (Anticoagulation Using the Direct Factor Xa Inhibitor Apixaban During Atrial Fibrillation Catheter Ablation: Comparison to Vitamin K Antagonist Therapy), which randomized 674 patients with AF 1:1 to uninterrupted apixaban or vitamin K antagonist therapy before first-time ablation. Brain magnetic resonance imaging using fluid-attenuated inversion recovery and high-resolution diffusion-weighted imaging was obtained within 3 to 48 hours after AF ablation in all eligible patients enrolled in 25 study centers in Europe and the United States. Patients underwent cognitive assessment 3 to 6 weeks before ablation and 3 months after ablation using the Montreal Cognitive Assessment (MoCA). RESULTS: In 84 (26.1%) of 321 patients with analyzable magnetic resonance imaging, high-resolution diffusion-weighted imaging detected at least 1 acute brain lesion, including 44 (27.2%) patients treated with apixaban and 40 (24.8%) patients treated with vitamin K antagonist (P=0.675). Median MoCA score was similar in patients with or without acute brain lesions at 3 months after ablation (28 [interquartile range (IQR), 26-29] versus 28 [IQR, 26-29]; P=0.948). Cerebral chronic white matter damage (defined as Wahlund score ≥4 points) detected by fluid-attenuated inversion recovery was present in 130 (40.5%) patients and associated with lower median MoCA scores before ablation (27 [IQR, 24-28] versus 27 [IQR, 25-29]; P=0.026) and 3 months after ablation (27 [IQR, 25-29] versus 28 [IQR, 26-29]; P=0.011). This association was no longer significant when adjusted for age and sex. Age was associated with lower MoCA scores before ablation (relative risk, 1.02 per 10 years [95% CI, 1.01-1.03]) and 3 months after ablation (relative risk, 1.02 per 10 years [95% CI, 1.01-1.03]). CONCLUSIONS: Chronic white matter damage as well as acute ischemic lesions detected by brain magnetic resonance imaging were found frequently after first-time ablation for paroxysmal AF using uninterrupted oral anticoagulation. Acute ischemic brain lesions detected by high-resolution diffusion-weighted imaging were not associated with cognitive function at 3 months after ablation. Lower MoCA scores before and after ablation were associated only with older age, highlighting the safety of AF ablation on uninterrupted oral anticoagulation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02227550.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Anticoagulantes/uso terapêutico , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Encéfalo/diagnóstico por imagem , Ablação por Cateter/efeitos adversos , Cognição , Humanos , Imageamento por Ressonância Magnética , Resultado do Tratamento , Vitamina KRESUMO
The purpose of this paper was to highlight the importance of the anatomy of the right ventricular outflow tract (RVOT) and the proximity of the mid segment of the left anterior descending coronary artery (LAD) to the RVOT in the setting of ablation of ventricular arrhythmias in the RVOT. During the period from 2014 till 2017, five patients with injury to the LAD during ablation within RVOT were identified in three centers, in Belgium, Germany and Israel. The clinical characteristics, procedural data and follow up data, where available, are reported. The literature review over coronary artery damage during radiofrequency ablation procedures is provided and the anatomy of the RVOT and the neighboring vascular structures is discussed. We present five patients who underwent radiofrequency ablation of ventricular arrhythmias mapped to the inferior and anterior part of the RVOT, at the insertion of the right ventricular wall to the septum, whereby ablation resulted in occlusion in four and severe stenosis in one, of the mid segment of the LAD coronary artery. All patients underwent percutaneous coronary intervention and stenting, four of them immediately during the same procedure and one 3 days later because of lack of signs and symptoms of acute coronary occlusion. In conclusion, the mid segment of the LAD at the level of the second septal perforator/second diagonal branch runs in very close proximity to the endocardial aspect of the lower part of the RVOT and care should be taken during ablation of ventricular arrhythmias in this region. Additional imaging such as intracardiac echocardiography and coronary angiography may be helpful in avoiding complications.
Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Eletrocardiografia , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgiaRESUMO
AIMS: Pulsed field ablation (PFA) has emerged as a promising alternative to thermal ablation for treatment of atrial fibrillation (AF). We report performance and safety using the CENTAURI™ System (Galvanize Therapeutics) with three commercial, focal ablation catheters. METHODS AND RESULTS: ECLIPSE AF (NCT04523545) was a prospective, single-arm, multi-centre study evaluating safety and acute and chronic pulmonary vein isolation (PVI) durability using the CENTAURI System in conjunction with the TactiCath SE, StablePoint, and ThermoCool ST ablation catheters. Patients with paroxysmal or persistent AF were treated at two centres. Patients were analysed in five cohorts based upon ablation settings, catheter, and mapping system. Pulsed field ablation was performed in 82 patients (74% male, 42 paroxysmal AF). Pulmonary vein isolation was achieved in 100% of pulmonary veins (322/322) with first-pass isolation in 92.2% (297/322). There were four serious adverse events of interest (three vascular access complications and one lacunar stroke). Eighty patients (98%) underwent invasive remapping. Pulsed field ablation development Cohorts 1 and 2 showed a per-patient isolation rate of 38% and 26% and a per-PV isolation rate of 47% and 53%, respectively. Optimized PFA Cohorts 3-5 showed a per-patient isolation rate of 60%, 73%, and 81% and a per-PV isolation rate of 84%, 90%, and 92%, respectively. CONCLUSION: ECLIPSE AF demonstrated that optimized PFA using the CENTAURI System with three commercial, contact force-sensing, solid-tip focal ablation catheters resulted in transmural lesion formation and high proportion of durable PVI with a favourable safety profile, thus providing a viable treatment option for AF that integrates with contemporary focal ablation workflows.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Adesões Focais , Resultado do Tratamento , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , RecidivaRESUMO
AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65â min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Acidente Vascular Cerebral , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Adulto JovemRESUMO
AIMS: To evaluate the safety and effectiveness of pulmonary vein isolation in paroxysmal atrial fibrillation (PAF) using a standardized workflow aiming to enclose the veins with contiguous and optimized radiofrequency lesions. METHODS AND RESULTS: This multicentre, prospective, non-randomized study was conducted at 17 European sites. Pulmonary vein isolation was guided by VISITAG SURPOINT (VS target ≥550 on the anterior wall; ≥400 on the posterior wall) and intertag distance (≤6 mm). Atrial arrhythmia recurrence was stringently monitored with weekly and symptom-driven transtelephonic monitoring on top of standard-of-care monitoring (24-h Holter and 12-lead electrocardiogram at 3, 6, and 12 months follow-up). Three hundred and forty participants with drug refractory PAF were enrolled. Acute effectiveness (first-pass isolation proof to a 30-min wait period and adenosine challenge) was 82.4% [95% confidence interval (CI) 77.4-86.7%]. At 12-month follow-up, the rate of freedom from any documented atrial arrhythmia was 78.3% (95% CI 73.8-82.8%), while freedom from atrial arrhythmia by standard-of-care monitoring was 89.4% (95% CI 78.8-87.0%). Freedom fromrepeat ablations by the Kaplan-Meier analysis was 90.4% during 12 months of follow-up. Of the 34 patients with repeat ablations, 14 (41.2%) demonstrated full isolation of all pulmonary vein circles. Primary adverse event (PAE) rate was 3.6% (95% CI 1.9-6.3%). CONCLUSIONS: The VISTAX trial demonstrated that a standardized PAF ablation workflow aiming for contiguous lesions leads to low rates of PAEs, high acute first-pass isolation rates, and 12-month freedom from arrhythmias approaching 80%. Further research is needed to improve the reproducibility of the outcomes across a wider range of centres.Clinical trial registration: ClinicalTrials.gov, number NCT03062046, https://clinicaltrials.gov/ct2/show/NCT03062046.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Reprodutibilidade dos Testes , Resultado do Tratamento , Fluxo de TrabalhoRESUMO
AIMS: This cross-sectional study was set up to assess the feasibility of mass screening for atrial fibrillation (AF) with only the use of a smartphone. METHODS AND RESULTS: A local newspaper published an article, allowing to subscribe for a 7-day screening period to detect AF. Screening was performed through an application that uses photo-plethysmography (PPG) technology by exploiting a smartphone camera. Participants received instructions on how to perform correct measurements twice daily, with notifications pushed through the application's software. In case of heart rhythm irregularities, raw PPG signals underwent secondary offline analysis to confirm a final diagnosis. From 12 328 readers who voluntarily signed up for screening (49 ± 14 years; 58% men), 120 446 unique PPG traces were obtained. Photo-plethysmography signal quality was adequate for analysis in 92% of cases. Possible AF was detected in 136 individuals (1.1%). They were older (P < 0.001), more frequently men (P < 0.001), and had higher body mass index (P = 0.004). In addition, participants who strictly adhered to the recommended screening frequency (i.e. twice daily) were more often diagnosed with possible AF (1.9% vs. 1.0% in individuals who did not adhere; P = 0.008). Symptoms of palpitations, confusion, and shortness of breath were more frequent in case of AF (P < 0.001). The cumulative diagnostic yield for possible AF increased from 0.4% with a single heart rhythm assessment to 1.4% with screening during the entire 7-day screening period. CONCLUSION: Mass screening for AF using only a smartphone with dedicated application based on PPG technology is feasible and attractive because of its low cost and logistic requirements.
Assuntos
Fibrilação Atrial/diagnóstico , Programas de Rastreamento , Fotopletismografia , Smartphone , Fibrilação Atrial/epidemiologia , Bélgica/epidemiologia , Estudos Transversais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Programas de Rastreamento/instrumentação , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Aplicativos Móveis , Fotopletismografia/instrumentação , Fotopletismografia/métodosRESUMO
Aims: To evaluate the effect of telemonitoring on adherence to non-vitamin K antagonist oral anticoagulants (NOACs) in atrial fibrillation (AF) patients. Methods and results: A randomized, single-blind, crossover, controlled trial in 48 AF patients on once or twice daily (OD or BID) NOAC. The Medication Event Monitoring System tracked NOAC intake during three phases of 3 months each: daily telemonitoring, telemonitoring with immediate telephone feedback in case of intake errors, and an observation phase without daily transmissions. Unprotected days were defined as ≥ 3 or ≥ 1 consecutively missed doses for a BID or OD NOAC, respectively, or excess dose intake. Cost-effectiveness was calculated based on anticipated stroke reduction derived from patients' risk profile and measured intake. Persistence over the entire study was 98%. Telemonitoring-only already led to very high taking and regimen adherence (97.4% respectively 93.8%). Nevertheless, direct feedback further improved both to 99.0% and 96.8%, respectively (P < 0.001 respectively P = 0.002). Observation without daily monitoring resulted in a significant waning of taking adherence (94.3%; P = 0.049). Taking adherence was significantly higher for OD compared to BID NOAC, although unprotected days were similar. Feedback intervention had an incremental cost of 344 289 to prevent one stroke, but this could be as low as 15 488 in high-risk patients with low adherence and optimized technology. Conclusion: Telemonitoring resulted in high NOAC adherence due to the notion of being watched, as evidenced by the rapid decline during the observation period. Feedback further optimized adherence. Telemonitoring with or without feedback may be a cost-effective approach in high-risk patients deemed poorly adherent.
Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Adesão à Medicação , Monitorização Ambulatorial/métodos , Administração Oral , Idoso , Anticoagulantes/administração & dosagem , Fibrilação Atrial/complicações , Análise Custo-Benefício , Estudos Cross-Over , Retroalimentação , Feminino , Humanos , Masculino , Monitorização Ambulatorial/economia , Pirazóis/administração & dosagem , Pirazóis/uso terapêutico , Piridonas/administração & dosagem , Piridonas/uso terapêutico , Rivaroxabana/administração & dosagem , Rivaroxabana/uso terapêutico , Método Simples-Cego , Acidente Vascular Cerebral/prevenção & controleRESUMO
Aims: It is recommended to perform atrial fibrillation ablation with continuous anticoagulation. Continuous apixaban has not been tested. Methods and results: We compared continuous apixaban (5 mg b.i.d.) to vitamin K antagonists (VKA, international normalized ratio 2-3) in atrial fibrillation patients at risk of stroke a prospective, open, multi-centre study with blinded outcome assessment. Primary outcome was a composite of death, stroke, or bleeding (Bleeding Academic Research Consortium 2-5). A high-resolution brain magnetic resonance imaging (MRI) sub-study quantified acute brain lesions. Cognitive function was assessed by Montreal Cognitive Assessment (MoCA) at baseline and at end of follow-up. Overall, 674 patients (median age 64 years, 33% female, 42% non-paroxysmal atrial fibrillation, 49 sites) were randomized; 633 received study drug and underwent ablation; 335 undertook MRI (25 sites, 323 analysable scans). The primary outcome was observed in 22/318 patients randomized to apixaban, and in 23/315 randomized to VKA {difference -0.38% [90% confidence interval (CI) -4.0%, 3.3%], non-inferiority P = 0.0002 at the pre-specified absolute margin of 0.075}, including 2 (0.3%) deaths, 2 (0.3%) strokes, and 24 (3.8%) ISTH major bleeds. Acute small brain lesions were found in a similar number of patients in each arm [apixaban 44/162 (27.2%); VKA 40/161 (24.8%); P = 0.64]. Cognitive function increased at the end of follow-up (median 1 MoCA unit; P = 0.005) without differences between study groups. Conclusions: Continuous apixaban is safe and effective in patients undergoing atrial fibrillation ablation at risk of stroke with respect to bleeding, stroke, and cognitive function. Further research is needed to reduce ablation-related acute brain lesions.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Pirazóis/uso terapêutico , Piridonas/uso terapêutico , Acidente Vascular Cerebral/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/psicologia , Encéfalo/diagnóstico por imagem , Cognição , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Pirazóis/efeitos adversos , Piridonas/efeitos adversos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Resultado do Tratamento , Vitamina K/antagonistas & inibidoresRESUMO
This report presents and discusses, on behalf of the Belgian College of Cardiology, the evolution of the peer review process in arrhythmology, focussing on pacemaker implantation. Data from the last 22 years are compared. The national annual increase in implants is around 1%, clinical patient characteristics remained stable over the years while dual chamber pacing was proportionally increasing. Analyses of the normalised sick sinus and complete atrioventricular block ratios revealed a quite homogenous practice between centres and patient district with the only exception of the two more crowded districts. Battery longevity and infection rate were also assessed. With an incidence of 1/1000 device-years follow-up, Belgium remains below accepted European levels.
Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/normas , Cardiologia , Marca-Passo Artificial/estatística & dados numéricos , Revisão por Pares/métodos , Garantia da Qualidade dos Cuidados de Saúde , Sociedades Médicas , Idoso , Bélgica , Bases de Dados Factuais , Feminino , Humanos , Masculino , Sistema de Registros , Estudos RetrospectivosRESUMO
AIMS: Peripheral arterial disease (PAD) is highly prevalent in general population. Data on the prevalence of symptomatic PAD in patients with atrial fibrillation (AF) are limited, and the impact of PAD on adverse outcomes in AF patients is controversial. Our aims were: (i) to define the prevalence of symptomatic PAD in European AF patients and describe its associated clinical risk factors and (ii) to establish the relationship of PAD to adverse events in AF, especially all-cause death. METHODS AND RESULTS: Atrial fibrillation patients enrolled in the EORP-AF Pilot study with data about PAD status were included in this analysis. Event rates were determined at 1-year follow-up. Peripheral arterial disease was recorded in 328 (11%) patients. Age (P < 0.0001), hypertension (P = 0.0059), diabetes mellitus (P = 0.0001), chronic heart failure (P < 0.0001), previous stroke/transient ischaemic attack (P = 0.0060), and antiplatelet drug treatment (P = 0.0001) were associated with the presence of PAD, while female gender was inversely associated (P = 0.0002). Peripheral arterial disease patients had higher absolute rates of both cardiovascular (CV) and all-cause death (both P < 0.0001). On Kaplan-Meier analysis, risk of all-cause death was higher in PAD patients compared with those without PAD (P < 0.0001), but PAD did not emerge as an independent risk factor for mortality on Cox regression analysis. A lower risk of all-cause death was associated with the prescription of statins (P = 0.0019), angiotensin-converting enzyme inhibitors (P = 0.0008), and calcium-channel blockers (P = 0.0071). CONCLUSION: Peripheral arterial disease is prevalent in 11% of AF patients and related to various atherosclerotic risk factors. Even if PAD is associated with higher risk of all-cause death on univariate analysis, this risk was significantly lowered and was no longer evident after adjusting for the use of CV prevention drugs.
Assuntos
Fibrilação Atrial/epidemiologia , Doença Arterial Periférica/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/mortalidade , Fármacos Cardiovasculares/uso terapêutico , Causas de Morte , Distribuição de Qui-Quadrado , Europa (Continente)/epidemiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/tratamento farmacológico , Doença Arterial Periférica/mortalidade , Projetos Piloto , Prevalência , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de TempoRESUMO
AIMS: To determine the usability, accuracy, and cost-effectiveness of two handheld single-lead electrocardiogram (ECG) devices for atrial fibrillation (AF) screening in a hospital population with an increased risk for AF. METHODS AND RESULTS: Hospitalized patients (n = 445) at cardiological or geriatric wards were screened for AF by two handheld ECG devices (MyDiagnostick and AliveCor). The performance of the automated algorithm of each device was evaluated against a full 12-lead or 6-lead ECG recording. All ECGs and monitor tracings were also independently reviewed in a blinded fashion by two electrophysiologists. Time investments by nurses and physicians were tracked and used to estimate cost-effectiveness of different screening strategies. Handheld recordings were not possible in 7 and 21.4% of cardiology and geriatric patients, respectively, because they were not able to hold the devices properly. Even after the exclusion of patients with an implanted device, sensitivity and specificity of the automated algorithms were suboptimal (Cardiology: 81.8 and 94.2%, respectively, for MyDiagnostick; 54.5 and 97.5%, respectively, for AliveCor; Geriatrics: 89.5 and 95.7%, respectively, for MyDiagnostick; 78.9 and 97.9%, respectively, for AliveCor). A scenario based on automated AliveCor evaluation in patients without AF history and without an implanted device proved to be the most cost-effective method, with a provider cost to identify one new AF patient of 193 and 82 at cardiology and geriatrics, respectively. The cost to detect one preventable stroke per year would be 7535 and 1916, respectively (based on average CHA2DS2-VASc of 3.9 ± 2.0 and 5.0 ± 1.5, respectively). Manual interpretation increases sensitivity, but decreases specificity, doubling the cost per detected patient, but remains cheaper than sole 12-lead ECG screening. CONCLUSION: Using AliveCor or MyDiagnostick handheld recorders requires a structured screening strategy to be effective and cost-effective in a hospital setting. It must exclude patients with implanted devices and known AF, and requires targeted additional 12-lead ECGs to optimize specificity. Under these circumstances, the expenses per diagnosed new AF patient and preventable stroke are reasonable.
Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Serviço Hospitalar de Cardiologia , Telefone Celular , Eletrocardiografia/instrumentação , Geriatria , Sistema de Condução Cardíaco/fisiopatologia , Hospitalização , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Fibrilação Atrial/economia , Fibrilação Atrial/fisiopatologia , Bélgica , Serviço Hospitalar de Cardiologia/economia , Telefone Celular/economia , Simulação por Computador , Análise Custo-Benefício , Eletrocardiografia/economia , Desenho de Equipamento , Feminino , Geriatria/economia , Frequência Cardíaca , Custos Hospitalares , Humanos , Masculino , Pessoa de Meia-Idade , Aplicativos Móveis , Modelos Econômicos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Centros de Atenção TerciáriaRESUMO
BACKGROUND: Chronic obstructive pulmonary disease (COPD) is a common chronic disease, being associated with both high rates of morbidity and mortality. Similarly, atrial fibrillation (AF) is associated with a higher risk of both cardiovascular (CV) events and overall mortality. The AF and COPD often coexist, but the impact of COPD on prognosis in European AF patients is unknown. METHODS: We evaluated COPD prevalence in patients enrolled in the EURObservational Research Programme Pilot Survey on Atrial Fibrillation Registry Pilot Phase. Clinical factors associated with COPD and adverse outcomes at 1-year follow-up were determined. RESULTS: In the overall cohort, a diagnosis of COPD was recorded in 339 (11.0%) of AF patients. The AF patients with COPD were more burdened with risk factors and comorbidities, including diabetes mellitus (P < .0001) and chronic heart failure (P < .0001). ß-Blockers were less likely to be prescribed to patients with COPD (P = .0007). On follow-up, AF patients with COPD had a higher risk of both CV death and all-cause death (both P < .0001), as well as for the composite outcome of any thromboembolic event/bleeding /CV death (P = .0003). Cox regression analysis found that COPD was independently associated with an increase in all-cause death (hazard ratio, 1.55; 95% CI 1.05-2.28; P = .0269). CONCLUSIONS: Chronic obstructive pulmonary disease is highly prevalent in European AF patients, and is associated with higher rates of CV death, all-cause death, and the composite outcome of any thromboembolic event/bleeding/CV death. The presence of COPD in AF patients was independently associated with all-cause death in AF patients.
Assuntos
Fibrilação Atrial/epidemiologia , Mortalidade , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Sistema de Registros , Síndrome Coronariana Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/mortalidade , Causas de Morte , Comorbidade , Diabetes Mellitus/epidemiologia , Feminino , Parada Cardíaca/epidemiologia , Insuficiência Cardíaca/epidemiologia , Hemorragia/epidemiologia , Humanos , Ataque Isquêmico Transitório/epidemiologia , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Projetos Piloto , Prevalência , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Embolia Pulmonar/epidemiologia , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Tromboembolia/epidemiologia , Tromboembolia Venosa/epidemiologiaAssuntos
Fibrilação Atrial/terapia , Atenção à Saúde/métodos , Inibidores do Fator Xa/uso terapêutico , Conhecimentos, Atitudes e Prática em Saúde , Educação de Pacientes como Assunto/métodos , Doenças Cardiovasculares/mortalidade , Tomada de Decisão Compartilhada , Serviço Hospitalar de Emergência , Hospitalização/estatística & dados numéricos , Humanos , Adesão à Medicação , Avaliação das Necessidades , Participação do Paciente , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
AIMS: Despite the increased prevalence of atrial fibrillation (AF), data for the implementation of nationwide screening programmes are limited. The aim of this national screening study was to increase nationwide awareness about AF and stroke risk, to determine the prevalence of AF in Belgian general population using an ECG handheld machine and its feasibility to identify new AF cases. METHODS AND RESULTS: We analysed data obtained from 5 years of the 'Belgian Heart Rhythm Week' screening programme. All subjects were screened using a one-lead ECG handheld machine. Among 65 747 subjects screened, AF was recorded in 911, with an overall prevalence of 1.4% [95% confidence interval (CI) 1.2-1.6%]. High thrombo-embolic risk, as assessed by CHA2DS2-VASc score ≥2, was recorded in 69% of AF subjects. In subjects with high thrombo-embolic risk, only 5.4% were treated with oral anticoagulant (OAC) and 5.8% were treated with OAC and antiplatelet drugs. Among recorded AF cases, the use of the ECG handheld machine allowed identification of 603 new AF patients (1.1%, 95% CI 0.9-1.3%). Factors associated with incident AF were chronic heart failure (P < 0.001), age (P < 0.001), diabetes mellitus (P < 0.001), previous stroke (P < 0.001), vascular disease (P < 0.001), and male sex (P < 0.001). CONCLUSION: In this Belgian national screening programme, prevalence of AF was 1.4%. The use of an ECG handheld machine is feasible to identify a significant number of new AF cases, most with a high thrombo-embolic risk. Given the low OAC use recorded, greater efforts in AF detection and treatment are urgently needed to reduce the burden of stroke associated with this common arrhythmia.