Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-24261080

RESUMO

We compare the quality and reliability of laser desorption and ionisation mass spectra of FeCl3 acquired without the assistance of the matrix with the spectra acquired with different organic matrix molecules. Generally, inorganic salts tend to form clusters upon laser irradiation, the signals of which can be easily distinguished from ions arising from the matrix. In the presence of a matrix, cluster ions are, however, mostly suppressed. We have compared the number of analyte signals, accuracy of determination of isotope composition of the analyte and the sensitivity of FeCl3 detection between different approaches. The results obtained imply that the sensitivity of mass spectrometric analysis of FeCl3 is somewhat higher when matrices are applied than in the matrix-free approach. Among all matrices tested in this work, F20TPP seems to be the most promising for further applications as a matrix for mass spectrometry of inorganic salts.


Assuntos
Cloretos/análise , Compostos Férricos/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Indicadores e Reagentes , Radioisótopos de Ferro/química , Limite de Detecção
2.
Chem Biodivers ; 10(11): 1972-86, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24243606

RESUMO

Phospholipase A2 is involved in propagation of inflammatory processes and carcinogenesis through its role in phospholipid metabolism, and release of arachidonic acid and lysophospholipids. Recent findings on correlation between elevated PLA2 activity and metastatic cancer render this enzyme an attractive target for cancer therapy. On the other hand, due to a broad range of oxidation states under physiological conditions and a high affinity for protein binding, platinum and ruthenium coordination complexes are promising candidates for PLA2 inhibitors. In this article, we discuss the interactions of Pt and Ru coordination complexes with PLA2 and phospholipids, as well as the application of MALDI-TOF mass spectrometry for screening PLA2 inhibitors. Owing to the ability of this technique to simultaneously detect and monitor changes in substrate and product concentrations, the inhibitor mechanisms of both Pt and Ru complexes with various ligands were determined.


Assuntos
Complexos de Coordenação/farmacologia , Inibidores de Fosfolipase A2/farmacologia , Fosfolipases A2/metabolismo , Fosfolipídeos/metabolismo , Platina/farmacologia , Rutênio/farmacologia , Animais , Complexos de Coordenação/química , Humanos , Pâncreas/enzimologia , Inibidores de Fosfolipase A2/química , Platina/química , Rutênio/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Suínos
3.
Rapid Commun Mass Spectrom ; 26(17): 2041-50, 2012 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-22847704

RESUMO

RATIONALE: Nanoparticles as substrates for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) have advantages over organic matrices, since they enable acquisition of spectra in the low-mass range. It has been previously shown that TiO(2) nanoparticles can be used as substrate for MALDI-TOF MS analysis of phospholipids and for other types of molecules, but none of them was applied to the analysis of transition metal complexes. METHODS: The MALDI-TOF mass spectra of potential anti-tumor drugs [AuCl(2)(bipy)]Cl, [PtCl(4)(bipy)], and [RuCl(2)(bipy)(2) ]Cl acquired with organic matrices have been compared with spectra acquired with colloidal titanium dioxide nanoparticles. Colloidal TiO(2) nanoparticles (NPs) with average diameter of 5 nm were synthesized and characterized by microscopy. For some experiments, the TiO(2) NPs were treated at 60 °C. Suspensions of matrix and the analyte were premixed, applied to the MALDI target and left at room temperature. Mass spectra were acquired with a 50-Hz pulsed nitrogen laser emitting at a wavelength of 337 nm. RESULTS: The MALDI spectra of transition metal complexes acquired with TiO(2) NPs exhibited somewhat lower sensitivity than those with organic matrices; on the other hand, they are characterized by significantly lower number of signals arising from the tested complexes than the organic matrices. Whereas adducts between organic matrices and the analytes were detectable in the spectra, this was not the case for the TiO(2)-assisted mass spectra. CONCLUSIONS: We have shown that colloidal TiO(2) NPs can be used as substrates for MALDI-TOF MS of transition metal complexes. Although the sensitivity of this approach in comparison with the use of organic matrices might still be a problem, the potential of the applications of NPs for the mass spectrometric characterization of transition metal complexes is clearly demonstrated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA