Analyst ; 141(11): 3274-9, 2016 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-27097527

RESUMO

The self-assembly of an adamantane-appended polymer bearing an antigen fragment on a polypyrrole-cyclodextrin modified surface provides a highly sensitive immunosensor with low limits of detection for celiac disease related targets. The pyrrole-carboxylic acid films were formed on the surface of gold electrodes by electropolymerisation and followed by covalent attachment of cyclodextrin units. Surface plasmon resonance measurements confirmed the role of the host/guest interactions between adamantane moieties and ß-cyclodextrin hosts in the formation of the supramolecular sensor interface. Furthermore, this novel electrochemical supramolecular platform was effective in the amperometric detection of anti-gliadin antibodies in spiked serum samples with very good signal recovery.


Assuntos
Anticorpos/isolamento & purificação , Técnicas Biossensoriais , Ciclodextrinas/química , Pirróis/química , Doença Celíaca , Ouro , Humanos , Ressonância de Plasmônio de Superfície
2.
Langmuir ; 31(1): 535-41, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25496567

RESUMO

Small carbon nano-onions (CNOs, 6-12 shells) were prepared in high yields and functionalized with carboxylic groups by chemical oxidation and reacted with ßCD-NH2 to yield CNOs decorated with ßCDs. A biocompatibile dextran polymer with graphted ferrocene groups was employed for the supramolecular self-assembly on the ßCD-CNO surfaces. The ßCDs act as hosts and the polymer ferrocene groups as guests (Fc-Dex) by the formation of inclusion complexes. After their assembly these nanostructures were soluble in aqueous solutions. The resulting product was characterized by transmission electron microscopy (TEM), thermogravimetric analysis (TGA), and FT-IR and Raman spectroscopies. Moreover, the deposition of successive layers on the surface of the particles was monitored using DLS measurements and zeta potentials. Through-space interactions between the Fc moieties and the CNO cores and the influence of an additional dextran-ßCD outer layer were measured electrochemically.


Assuntos
Carbono/química , Ciclodextrinas/química , Nanoestruturas/química , Ácidos Carboxílicos/química , Eletroquímica , Compostos Ferrosos/química , Metalocenos , Modelos Moleculares , Conformação Molecular , Solubilidade
3.
Analyst ; 139(2): 375-80, 2014 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-24276364

RESUMO

Cyclodextrin nanosponges bearing carboxylate groups have been prepared by crosslinking ß-cyclodextrin with pyromellitic dianhydride to form a carboxylic acid terminated nanoporous material. The surface of the particles was covalently modified with an anti-IgG antibody and then loaded with horseradish peroxidase. The structures of unmodified and protein modified nanosponge particles were investigated by Raman spectroscopy and imaging methods. Confocal microscopy indicates that the antibody is located in the outside of the particle while HRP is encapsulated in the inner part. The possibility to use these modified nanosponges as a signal enhancement tool in enzyme-linked colorimetric and electrochemical assays was evaluated using a sandwich format comprising immobilised gliadin as an antigen, a target anti-gliadin antibody and an anti-IgG antibody conjugated to the enzyme-loaded nanosponge immunoconjugates.


Assuntos
Técnicas Biossensoriais/métodos , Ciclodextrinas/química , Eletroquímica/métodos , Peroxidase do Rábano Silvestre/metabolismo , Imunoconjugados/química , Nanopartículas , Fenômenos Ópticos , Anticorpos/análise , Anticorpos/imunologia , Cápsulas , Colorimetria
4.
Biomed Opt Express ; 13(3): 1609-1619, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35415002

RESUMO

Current diagnostics of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection heavily rely on reverse transcription-polymerase chain reaction (RT-PCR) or on rapid antigen detection tests. The former suffers from long time-to-result and high cost while the latter from poor sensitivity. Therefore, it is crucial to develop rapid, sensitive, robust, and inexpensive methods for SARS-CoV-2 testing. Herein, we report a novel optofluidic technology, a flow-virometry reader (FVR), for fast and reliable SARS-CoV-2 detection in saliva samples. A small microfluidic chip together with a laser-pumped optical head detects the presence of viruses tagged with fluorescent antibodies directly from saliva samples. The technology has been validated using clinical samples with high sensitivity (91.2%) and specificity (90%). Thanks also to its short time-to-result (<30 min) and small size (25 × 30 × 13 cm), which can be further reduced in the future, it is a strong alternative to existing tests, especially for point-of-care (POC) and low resource settings.

5.
Sci Adv ; 7(47): eabj2155, 2021 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-34788099

RESUMO

Quantum techniques can be used to enhance the signal-to-noise ratio in optical imaging. Leveraging the latest advances in single-photon avalanche diode array cameras and multiphoton detection techniques, here, we introduce a supersensitive phase imager, which uses space-polarization hyperentanglement to operate over a large field of view without the need of scanning operation. We show quantum-enhanced imaging of birefringent and nonbirefringent phase samples over large areas, with sensitivity improvements over equivalent classical measurements carried out with equal number of photons. The potential applicability is demonstrated by imaging a biomedical protein microarray sample. Our technology is inherently scalable to high-resolution images and represents an essential step toward practical quantum-enhanced imaging.

6.
Nanoscale ; 12(17): 9647-9652, 2020 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-32319508

RESUMO

Easy monitoring of prostate specific antigen (PSA) directly from blood samples would present a significant improvement as compared to conventional diagnostic methods. In this work, a split mode thin film bulk acoustic resonator (TFBAR) device was employed for the first time for label-free measurements of PSA concentrations in the whole blood and without sample pre-treatment. The surface of the sensor was covalently modified with anti-PSA antibodies and demonstrated a very high sensitivity of 101 kHz mL ng-1 and low limit of detection (LOD) of 0.34 ng mL-1 in model spiked solutions. It has previously been widely believed that significant pre-processing of blood samples would be required for TFBAR biosensors. Importantly, this work demonstrates that this is not the case, and TFBAR technology provides a cost-effective means for point-of-care (POC) diagnostics and monitoring of PSA in hospitals and in doctors' offices. Additionally, the accuracy of the developed biosensor, with respect to a commercial auto analyser (Beckman Coulter Access), was evaluated to analyse clinical samples, giving well-matched results between the two methods, thus showing a practical application in quantitative monitoring of PSA levels in the whole blood with very good signal recovery.


Assuntos
Técnicas Biossensoriais/métodos , Antígeno Prostático Específico/sangue , Acústica , Técnicas Biossensoriais/instrumentação , Humanos , Imunoensaio , Limite de Detecção , Masculino , Testes Imediatos
7.
Nanoscale ; 10(30): 14395-14399, 2018 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-30028470

RESUMO

A self-referenced resonator consisting of two distinct areas of the top electrode made from Mo and a thin (5-30 nm) functional Au layer is shown. The fundamental frequencies for both the shear (∼1 GHz) and longitudinal (∼2 GHz) modes are split in two, such that mass attachment on the functional layer region causes frequency shifts in only one of the resonances, allowing a new approach of using the difference between the two frequencies to be used to measure mass attachment; this reduces the importance of device-to-device variability in absolute resonant frequency as a result of device fabrication.