Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Laryngorhinootologie ; 103(3): 176-186, 2024 03.
Artigo em Alemão | MEDLINE | ID: mdl-38128578

RESUMO

The treatment of vestibular schwannomas (VS) has always posed a challenge for physicians. Three essential treatment principles are available: wait-and-scan, surgery, and stereotactic radiotherapy. In addition to the type of treatment, decisions must be made regarding the optimal timing of therapy, the combination of different treatment modalities, the potential surgical approach, and the type and intensity of radiation. Factors influencing the therapy decision include tumor location and size or stage, patient age, comorbidities, symptoms, postoperative hearing rehabilitation options, patient preferences, and, not least, the experience of the surgeons and the personnel and technical capabilities of the clinical site. This article begins with a brief overview of vestibular schwannomas, then outlines the fundamental interdisciplinary treatment options, and finally discusses the ENT (ear, nose, and throat)-relevant factors in the therapy decision.


Assuntos
Neuroma Acústico , Radiocirurgia , Humanos , Audição , Neuroma Acústico/diagnóstico , Neuroma Acústico/terapia , Resultado do Tratamento
2.
Brain Topogr ; 35(4): 431-452, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35668310

RESUMO

Cochlear implants (CIs) allow to restore the hearing function in profoundly deaf individuals. Due to the degradation of the stimulus by CI signal processing, implanted individuals with single-sided deafness (SSD) have the specific challenge that the input highly differs between their ears. The present study compared normal-hearing (NH) listeners (N = 10) and left- and right-ear implanted SSD CI users (N = 10 left, N = 9 right), to evaluate cortical speech processing between CI- and NH-ears and to explore for side-of-implantation effects. The participants performed a two-deviant oddball task, separately with the left and the right ear. Auditory event-related potentials (ERPs) in response to syllables were compared between proficient and non-proficient CI users, as well as between CI and NH ears. The effect of the side of implantation was analysed on the sensor and the source level. CI proficiency could be distinguished based on the ERP amplitudes of the N1 and the P3b. Moreover, syllable processing via the CI ear, when compared to the NH ear, resulted in attenuated and delayed ERPs. In addition, the left-ear implanted SSD CI users revealed an enhanced functional asymmetry in the auditory cortex than right-ear implanted SSD CI users, regardless of whether the syllables were perceived via the CI or the NH ear. Our findings reveal that speech-discrimination proficiency in SSD CI users can be assessed by N1 and P3b ERPs. The results contribute to a better understanding of the rehabilitation success in SSD CI users by showing that cortical speech processing in SSD CI users is affected by CI-related stimulus degradation and experience-related functional changes in the auditory cortex.


Assuntos
Córtex Auditivo , Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva Unilateral , Percepção da Fala , Implante Coclear/métodos , Humanos , Percepção da Fala/fisiologia
3.
J Acoust Soc Am ; 147(1): EL19, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-32007021

RESUMO

Cochlear implant (CI) recipients are limited in their perception of voice cues, such as the fundamental frequency (F0). This has important consequences for speech recognition when several talkers speak simultaneously. This examination considered the comparison of clear speech and noise-vocoded sentences as maskers. For the speech maskers it could be shown that good CI performers are able to benefit from F0 differences between target and masker. This was due to the fact that a F0 difference of 80 Hz significantly reduced target-masker confusions, an effect that was slightly more pronounced in bimodal than in bilateral users.


Assuntos
Implante Coclear/métodos , Mascaramento Perceptivo/fisiologia , Percepção da Fala/fisiologia , Teste do Limiar de Recepção da Fala/métodos , Adulto , Idoso , Implante Coclear/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Teste do Limiar de Recepção da Fala/normas
4.
Ear Hear ; 39(3): 503-516, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29068860

RESUMO

OBJECTIVES: Watching a talker's mouth is beneficial for speech reception (SR) in many communication settings, especially in noise and when hearing is impaired. Measures for audiovisual (AV) SR can be valuable in the framework of diagnosing or treating hearing disorders. This study addresses the lack of standardized methods in many languages for assessing lipreading, AV gain, and integration. A new method is validated that supplements a German speech audiometric test with visualizations of the synthetic articulation of an avatar that was used, for it is feasible to lip-sync auditory speech in a highly standardized way. Three hypotheses were formed according to the literature on AV SR that used live or filmed talkers. It was tested whether respective effects could be reproduced with synthetic articulation: (1) cochlear implant (CI) users have a higher visual-only SR than normal-hearing (NH) individuals, and younger individuals obtain higher lipreading scores than older persons. (2) Both CI and NH gain from presenting AV over unimodal (auditory or visual) sentences in noise. (3) Both CI and NH listeners efficiently integrate complementary auditory and visual speech features. DESIGN: In a controlled, cross-sectional study with 14 experienced CI users (mean age 47.4) and 14 NH individuals (mean age 46.3, similar broad age distribution), lipreading, AV gain, and integration of a German matrix sentence test were assessed. Visual speech stimuli were synthesized by the articulation of the Talking Head system "MASSY" (Modular Audiovisual Speech Synthesizer), which displayed standardized articulation with respect to the visibility of German phones. RESULTS: In line with the hypotheses and previous literature, CI users had a higher mean visual-only SR than NH individuals (CI, 38%; NH, 12%; p < 0.001). Age was correlated with lipreading such that within each group, younger individuals obtained higher visual-only scores than older persons (rCI = -0.54; p = 0.046; rNH = -0.78; p < 0.001). Both CI and NH benefitted by AV over unimodal speech as indexed by calculations of the measures visual enhancement and auditory enhancement (each p < 0.001). Both groups efficiently integrated complementary auditory and visual speech features as indexed by calculations of the measure integration enhancement (each p < 0.005). CONCLUSIONS: Given the good agreement between results from literature and the outcome of supplementing an existing validated auditory test with synthetic visual cues, the introduced method can be considered an interesting candidate for clinical and scientific applications to assess measures important for AV SR in a standardized manner. This could be beneficial for optimizing the diagnosis and treatment of individual listening and communication disorders, such as cochlear implantation.


Assuntos
Implantes Cocleares , Leitura Labial , Inteligibilidade da Fala , Percepção da Fala , Percepção Visual , Estimulação Acústica , Adulto , Estudos Transversais , Humanos , Pessoa de Meia-Idade
5.
J Acoust Soc Am ; 144(5): EL417, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30522293

RESUMO

This letter describes a dual-task paradigm sensitive to noise masking at favorable signal-to-noise ratios (SNRs). Two competing sentences differing in voice and context cues were presented against noise at SNRs of +2 and +6 dB. Listeners were asked to repeat back words from both competing sentences while prioritizing one of them. Recognition of the high-priority sentences was high and did not depend on the SNR. In contrast, recognition of the low-priority sentences was low and showed a significant SNR effect that was related to the listener's working memory capacity. This suggests that even subtle noise masking causes cognitive load in competing-talker situations.


Assuntos
Percepção Auditiva/fisiologia , Cognição/fisiologia , Ruído/efeitos adversos , Percepção da Fala/fisiologia , Idoso , Sinais (Psicologia) , Feminino , Humanos , Masculino , Memória de Curto Prazo/fisiologia , Pessoa de Meia-Idade , Razão Sinal-Ruído
6.
Int J Audiol ; 57(sup3): S105-S111, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28449597

RESUMO

OBJECTIVES: Model-based hearing aid development considers the assessment of speech recognition using a master hearing aid (MHA). It is known that aided speech recognition in noise is related to cognitive factors such as working memory capacity (WMC). This relationship might be mediated by hearing aid experience (HAE). The aim of this study was to examine the relationship of WMC and speech recognition with a MHA for listeners with different HAE. DESIGN: Using the MHA, unaided and aided 80% speech recognition thresholds in noise were determined. Individual WMC capacity was assed using the Verbal Learning and Memory Test (VLMT) and the Reading Span Test (RST). STUDY SAMPLE: Forty-nine hearing aid users with mild to moderate sensorineural hearing loss divided into three groups differing in HAE. RESULTS: Whereas unaided speech recognition did not show a significant relationship with WMC, a significant correlation could be observed between WMC and aided speech recognition. However, this only applied to listeners with HAE of up to approximately three years, and a consistent weakening of the correlation could be observed with more experience. CONCLUSIONS: Speech recognition scores obtained in acute experiments with an MHA are less influenced by individual cognitive capacity when experienced HA users are taken into account.


Assuntos
Algoritmos , Cognição , Correção de Deficiência Auditiva/instrumentação , Auxiliares de Audição , Perda Auditiva Neurossensorial/reabilitação , Audição , Pessoas com Deficiência Auditiva/reabilitação , Reconhecimento Psicológico , Processamento de Sinais Assistido por Computador , Percepção da Fala , Estimulação Acústica , Idoso , Idoso de 80 Anos ou mais , Audiometria de Tons Puros , Audiometria da Fala , Limiar Auditivo , Desenho de Equipamento , Feminino , Alemanha , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/fisiopatologia , Perda Auditiva Neurossensorial/psicologia , Humanos , Masculino , Memória de Curto Prazo , Pessoa de Meia-Idade , Modelos Teóricos , Testes Neuropsicológicos , Ruído/efeitos adversos , Mascaramento Perceptivo , Pessoas com Deficiência Auditiva/psicologia , Psicoacústica , Inteligibilidade da Fala
7.
Audiol Neurootol ; 22(1): 30-40, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28601886

RESUMO

BACKGROUND: Auditory synaptopathy/neuropathy (AS/AN) is a heterogeneous disorder, which may be caused by environmental factors like postnatal hyperbilirubinemia or by genetic factors. The genetic forms are subdivided into syndromic and non-syndromic types, and show different inheritance patterns with a strong preponderance of autosomal-recessive forms. To date, only a single locus for non-syndromic autosomal-dominant AS/AN (AUNA1) has been reported in a single family, in which a non-coding DIAPH3 mutation was subsequently described as causative. MATERIALS AND METHODS: Here, we report detailed clinical data on a large German AS/AN family with slowly progressive postlingual hearing loss. Affected family members developed their first symptoms in their second decade. Moderate hearing loss in the fourth decade then progressed to profound hearing impairment in older family members. Comprehensive audiological and neurological tests were performed in the affected family members. Genetic testing comprised linkage analyses with polymorphic markers and a genome-wide linkage analysis using the Affymetrix GeneChip® Human Mapping 250K. RESULTS AND CONCLUSION: We identified a large family with autosomal-dominant AS/AN. By means of linkage analyses, the AUNA1 locus was excluded, and putatively linked regions on chromosomal bands 12q24 and 13q34 were identified as likely carrying the second locus for autosomal-dominant AS/AN (AUNA2). AUNA2 is associated with a slowly progressive postlingual hearing loss without any evidence for additional symptoms in other organ systems.


Assuntos
Cromossomos Humanos Par 12/genética , Cromossomos Humanos Par 13/genética , Nervo Coclear/fisiopatologia , Perda Auditiva Central/genética , Linhagem , Doenças do Nervo Vestibulococlear/genética , Adolescente , Adulto , Idoso , Audiometria de Resposta Evocada , Audiometria de Tons Puros , Criança , Progressão da Doença , Feminino , Ligação Genética , Alemanha , Perda Auditiva Central/fisiopatologia , Perda Auditiva Neurossensorial/genética , Perda Auditiva Neurossensorial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Mutação , Doenças do Nervo Vestibulococlear/fisiopatologia , População Branca/genética
8.
J Acoust Soc Am ; 141(1): 197, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28147572

RESUMO

The aim of the study is the experimental determination of the optimal required masking level for a given stimulus level when using a band limited "low-frequency chirp" in order to improve frequency and place specificity of auditory brainstem responses (ABRs). A low-frequency chirp (100-850 Hz) at stimulation levels between 40 and 80 dB normalized hearing level was presented to 12 normal hearing subjects. During presentation of each stimulus, the level of a high-pass noise with a low cutoff frequency of 1100 Hz was varied between 0 and 25 dB signal-to-noise ratio (SNR) by using 5 dB steps (at 0 dB SNR the same level of both the chirp and the masker in dB sound pressure level was presented). Measurements without masking were used as a reference. In all masking conditions, the latency of wave V was significantly increased compared to unmasked ABRs. The amplitude of wave V decreased when reaching the effective and therefore optimal masking level. Accordingly, in order to ensure place specificity of the ABR, ipsilateral masking is essential. At lower stimulus levels the SNR can be substantially increased (i.e., the masker level decreased) without loss of place specificity.

9.
J Acoust Soc Am ; 139(6): 3116, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27369134

RESUMO

This study addressed the hypothesis that an improvement in speech recognition due to combined envelope and fine structure cues is greater in the audiovisual than the auditory modality. Normal hearing listeners were presented with envelope vocoded speech in combination with low-pass filtered speech. The benefit of adding acoustic low-frequency fine structure to acoustic envelope cues was significantly greater for audiovisual than for auditory-only speech. It is suggested that this is due to complementary information of the different acoustic and visual cues. The results have potential implications for the assessment of bimodal cochlear implant fittings or electroacoustic stimulation.


Assuntos
Sinais (Psicologia) , Reconhecimento Psicológico , Acústica da Fala , Percepção da Fala , Percepção Visual , Estimulação Acústica , Adulto , Audiometria da Fala , Feminino , Humanos , Masculino , Ruído/efeitos adversos , Mascaramento Perceptivo , Estimulação Luminosa , Adulto Jovem
10.
Int J Audiol ; 55(7): 412-8, 2015 07.
Artigo em Inglês | MEDLINE | ID: mdl-27139505

RESUMO

OBJECTIVE: The individual outcome after cochlear implantation in children with auditory synaptopathy/neuropathy (AS/AN) is difficult to predict. A tool for preoperative assessment would be helpful for counseling parents. This study evaluates the outcome after CI in children with AS/AN and with sensorineural hearing loss (SNHL), and correlates it with the preoperative ECochG results in order to find specific parameters of prognostic value. DESIGN: The improvement of auditory behavior after CI was retrospectively assessed using the LittlEARS questionnaire and quantified in a score (LS). This score was correlated with the CAP/SP ratio in the preoperative ECochG. The score was further correlated with the patient's age six months following CI. STUDY SAMPLE: Nine children with AS/AN were compared to nine children with SNHL. RESULTS: Both groups showed a significant improvement in LS following CI. There was a significant positive correlation between the CAP/SP ratio and the improvement in LS in all children. The correlation between age and LS was significantly negative in the SNHL group and positive in the AS/AN group. CONCLUSION: All children with AS/AN and SNHL benefit to a similar extent from CI. The preoperatively assessed CAP/SP ratio has a prognostic value for the development of auditory behavior following CI.


Assuntos
Audiometria de Resposta Evocada , Percepção Auditiva , Comportamento Infantil , Implante Coclear/instrumentação , Implantes Cocleares , Crianças com Deficiência/reabilitação , Perda Auditiva Central/reabilitação , Perda Auditiva Neurossensorial/reabilitação , Pessoas com Deficiência Auditiva/reabilitação , Fatores Etários , Criança , Pré-Escolar , Crianças com Deficiência/psicologia , Feminino , Perda Auditiva Central/diagnóstico , Perda Auditiva Central/fisiopatologia , Perda Auditiva Central/psicologia , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/fisiopatologia , Perda Auditiva Neurossensorial/psicologia , Humanos , Lactente , Masculino , Pessoas com Deficiência Auditiva/psicologia , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Estudos Retrospectivos , Inquéritos e Questionários , Resultado do Tratamento
11.
Hear Res ; 447: 109023, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38733710

RESUMO

Limited auditory input, whether caused by hearing loss or by electrical stimulation through a cochlear implant (CI), can be compensated by the remaining senses. Specifically for CI users, previous studies reported not only improved visual skills, but also altered cortical processing of unisensory visual and auditory stimuli. However, in multisensory scenarios, it is still unclear how auditory deprivation (before implantation) and electrical hearing experience (after implantation) affect cortical audiovisual speech processing. Here, we present a prospective longitudinal electroencephalography (EEG) study which systematically examined the deprivation- and CI-induced alterations of cortical processing of audiovisual words by comparing event-related potentials (ERPs) in postlingually deafened CI users before and after implantation (five weeks and six months of CI use). A group of matched normal-hearing (NH) listeners served as controls. The participants performed a word-identification task with congruent and incongruent audiovisual words, focusing their attention on either the visual (lip movement) or the auditory speech signal. This allowed us to study the (top-down) attention effect on the (bottom-up) sensory cortical processing of audiovisual speech. When compared to the NH listeners, the CI candidates (before implantation) and the CI users (after implantation) exhibited enhanced lipreading abilities and an altered cortical response at the N1 latency range (90-150 ms) that was characterized by a decreased theta oscillation power (4-8 Hz) and a smaller amplitude in the auditory cortex. After implantation, however, the auditory-cortex response gradually increased and developed a stronger intra-modal connectivity. Nevertheless, task efficiency and activation in the visual cortex was significantly modulated in both groups by focusing attention on the visual as compared to the auditory speech signal, with the NH listeners additionally showing an attention-dependent decrease in beta oscillation power (13-30 Hz). In sum, these results suggest remarkable deprivation effects on audiovisual speech processing in the auditory cortex, which partially reverse after implantation. Although even experienced CI users still show distinct audiovisual speech processing compared to NH listeners, pronounced effects of (top-down) direction of attention on (bottom-up) audiovisual processing can be observed in both groups. However, NH listeners but not CI users appear to show enhanced allocation of cognitive resources in visually as compared to auditory attended audiovisual speech conditions, which supports our behavioural observations of poorer lipreading abilities and reduced visual influence on audition in NH listeners as compared to CI users.


Assuntos
Estimulação Acústica , Atenção , Implante Coclear , Implantes Cocleares , Surdez , Eletroencefalografia , Pessoas com Deficiência Auditiva , Estimulação Luminosa , Percepção da Fala , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Implante Coclear/instrumentação , Adulto , Estudos Prospectivos , Estudos Longitudinais , Pessoas com Deficiência Auditiva/psicologia , Pessoas com Deficiência Auditiva/reabilitação , Surdez/fisiopatologia , Surdez/reabilitação , Surdez/psicologia , Estudos de Casos e Controles , Idoso , Percepção Visual , Leitura Labial , Fatores de Tempo , Audição , Potenciais Evocados Auditivos , Córtex Auditivo/fisiopatologia , Potenciais Evocados
12.
Clin Neurophysiol ; 154: 141-156, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37611325

RESUMO

OBJECTIVE: Hearing with a cochlear implant (CI) is difficult in noisy environments, but the use of noise reduction algorithms, specifically ForwardFocus, can improve speech intelligibility. The current event-related potentials (ERP) study examined the electrophysiological correlates of this perceptual improvement. METHODS: Ten bimodal CI users performed a syllable-identification task in auditory and audiovisual conditions, with syllables presented from the front and stationary noise presented from the sides. Brainstorm was used for spatio-temporal evaluation of ERPs. RESULTS: CI users revealed an audiovisual benefit as reflected by shorter response times and greater activation in temporal and occipital regions at P2 latency. However, in auditory and audiovisual conditions, background noise hampered speech processing, leading to longer response times and delayed auditory-cortex-activation at N1 latency. Nevertheless, activating ForwardFocus resulted in shorter response times, reduced listening effort and enhanced superior-frontal-cortex-activation at P2 latency, particularly in audiovisual conditions. CONCLUSIONS: ForwardFocus enhances speech intelligibility in audiovisual speech conditions by potentially allowing the reallocation of attentional resources to relevant auditory speech cues. SIGNIFICANCE: This study shows for CI users that background noise and ForwardFocus differentially affect spatio-temporal cortical response patterns, both in auditory and audiovisual speech conditions.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Percepção da Fala/fisiologia , Potenciais Evocados , Ruído/efeitos adversos
13.
Trends Hear ; 26: 23312165221111676, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35849353

RESUMO

In cocktail party situations multiple talkers speak simultaneously, which causes listening to be perceptually and cognitively challenging. Such situations can either be static (fixed target talker) or dynamic, meaning the target talker switches occasionally and in a potentially unpredictable way. To shed light on the perceptional and cognitive mechanisms in static and dynamic cocktail party situations, we conducted an analysis of error types that occur during a multi-talker speech recognition test. The error analysis distinguished between misunderstood or omitted words (random errors) and target-masker confusions. To investigate the effects of aging and hearing impairment, we compared data from three listener groups, comprised of young as well as older adults with and without hearing loss. In the static condition, error rates were generally very low, except for the older hearing-impaired listeners. Consistent with the assumption of decreased audibility, they showed a notable amount of random errors. In the dynamic condition, errors increased compared to the static condition, especially immediately following a target talker switch. Those increases were similar for random and confusion errors. The older hearing-impaired listeners showed greater difficulties than the younger adults in trials not preceded by a switch. These results suggest that the load associated with dynamic cocktail party listening affects the ability to focus attention on the talker of interest and the retrieval of words from short-term memory, as indicated by the increased amount of confusion and random errors. This was most pronounced in the older hearing-impaired listeners proposing an interplay of perceptual and cognitive mechanisms.


Assuntos
Perda Auditiva , Percepção da Fala , Idoso , Percepção Auditiva , Cognição , Perda Auditiva/diagnóstico , Humanos , Mascaramento Perceptivo
14.
Front Neurosci ; 16: 1005859, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36620447

RESUMO

A cochlear implant (CI) can partially restore hearing in individuals with profound sensorineural hearing loss. However, electrical hearing with a CI is limited and highly variable. The current study aimed to better understand the different factors contributing to this variability by examining how age affects cognitive functions and cortical speech processing in CI users. Electroencephalography (EEG) was applied while two groups of CI users (young and elderly; N = 13 each) and normal-hearing (NH) listeners (young and elderly; N = 13 each) performed an auditory sentence categorization task, including semantically correct and incorrect sentences presented either with or without background noise. Event-related potentials (ERPs) representing earlier, sensory-driven processes (N1-P2 complex to sentence onset) and later, cognitive-linguistic integration processes (N400 to semantically correct/incorrect sentence-final words) were compared between the different groups and speech conditions. The results revealed reduced amplitudes and prolonged latencies of auditory ERPs in CI users compared to NH listeners, both at earlier (N1, P2) and later processing stages (N400 effect). In addition to this hearing-group effect, CI users and NH listeners showed a comparable background-noise effect, as indicated by reduced hit rates and reduced (P2) and delayed (N1/P2) ERPs in conditions with background noise. Moreover, we observed an age effect in CI users and NH listeners, with young individuals showing improved specific cognitive functions (working memory capacity, cognitive flexibility and verbal learning/retrieval), reduced latencies (N1/P2), decreased N1 amplitudes and an increased N400 effect when compared to the elderly. In sum, our findings extend previous research by showing that the CI users' speech processing is impaired not only at earlier (sensory) but also at later (semantic integration) processing stages, both in conditions with and without background noise. Using objective ERP measures, our study provides further evidence of strong age effects on cortical speech processing, which can be observed in both the NH listeners and the CI users. We conclude that elderly individuals require more effortful processing at sensory stages of speech processing, which however seems to be at the cost of the limited resources available for the later semantic integration processes.

15.
Neuroimage Clin ; 34: 102982, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35303598

RESUMO

A cochlear implant (CI) is an auditory prosthesis which can partially restore the auditory function in patients with severe to profound hearing loss. However, this bionic device provides only limited auditory information, and CI patients may compensate for this limitation by means of a stronger interaction between the auditory and visual system. To better understand the electrophysiological correlates of audiovisual speech perception, the present study used electroencephalography (EEG) and a redundant target paradigm. Postlingually deafened CI users and normal-hearing (NH) listeners were compared in auditory, visual and audiovisual speech conditions. The behavioural results revealed multisensory integration for both groups, as indicated by shortened response times for the audiovisual as compared to the two unisensory conditions. The analysis of the N1 and P2 event-related potentials (ERPs), including topographic and source analyses, confirmed a multisensory effect for both groups and showed a cortical auditory response which was modulated by the simultaneous processing of the visual stimulus. Nevertheless, the CI users in particular revealed a distinct pattern of N1 topography, pointing to a strong visual impact on auditory speech processing. Apart from these condition effects, the results revealed ERP differences between CI users and NH listeners, not only in N1/P2 ERP topographies, but also in the cortical source configuration. When compared to the NH listeners, the CI users showed an additional activation in the visual cortex at N1 latency, which was positively correlated with CI experience, and a delayed auditory-cortex activation with a reversed, rightward functional lateralisation. In sum, our behavioural and ERP findings demonstrate a clear audiovisual benefit for both groups, and a CI-specific alteration in cortical activation at N1 latency when auditory and visual input is combined. These cortical alterations may reflect a compensatory strategy to overcome the limited CI input, which allows the CI users to improve the lip-reading skills and to approximate the behavioural performance of NH listeners in audiovisual speech conditions. Our results are clinically relevant, as they highlight the importance of assessing the CI outcome not only in auditory-only, but also in audiovisual speech conditions.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Estimulação Acústica/métodos , Percepção Auditiva/fisiologia , Potenciais Evocados , Humanos , Fala , Percepção da Fala/fisiologia , Percepção Visual/fisiologia
16.
Curr Res Neurobiol ; 3: 100059, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36405629

RESUMO

Hearing with a cochlear implant (CI) is limited compared to natural hearing. Although CI users may develop compensatory strategies, it is currently unknown whether these extend from auditory to visual functions, and whether compensatory strategies vary between different CI user groups. To better understand the experience-dependent contributions to multisensory plasticity in audiovisual speech perception, the current event-related potential (ERP) study presented syllables in auditory, visual, and audiovisual conditions to CI users with unilateral or bilateral hearing loss, as well as to normal-hearing (NH) controls. Behavioural results revealed shorter audiovisual response times compared to unisensory conditions for all groups. Multisensory integration was confirmed by electrical neuroimaging, including topographic and ERP source analysis, showing a visual modulation of the auditory-cortex response at N1 and P2 latency. However, CI users with bilateral hearing loss showed a distinct pattern of N1 topography, indicating a stronger visual impact on auditory speech processing compared to CI users with unilateral hearing loss and NH listeners. Furthermore, both CI user groups showed a delayed auditory-cortex activation and an additional recruitment of the visual cortex, and a better lip-reading ability compared to NH listeners. In sum, these results extend previous findings by showing distinct multisensory processes not only between NH listeners and CI users in general, but even between CI users with unilateral and bilateral hearing loss. However, the comparably enhanced lip-reading ability and visual-cortex activation in both CI user groups suggest that these visual improvements are evident regardless of the hearing status of the contralateral ear.

17.
Ear Hear ; 32(4): 459-67, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21187749

RESUMO

OBJECTIVES: Sentence stress is a vital attribute of speech since it indicates the importance of specific words within an utterance. Basic acoustic correlates of stress are syllable duration, intensity, and fundamental frequency (F0). Objectives of the study were to determine cochlear implant (CI) users' perception of the acoustic correlates and to uncover which cues are used for stress identification. DESIGN: Several experiments addressed the discrimination of changes in syllable duration, intensity, and F0 as well as stress identification based on these cues. Moreover, the discrimination of combined cues and identification of stress in conversational speech was examined. Both natural utterances and artificial manipulations of the acoustic cues were used as stimuli. RESULTS: Discrimination of syllable duration did not differ significantly between CI recipients and a control group of normal-hearing listeners. In contrast, CI users performed significantly worse on tasks of discrimination and stress identification based on F0 as well as on intensity. Results from these measurements were significantly correlated with the ability to identify stress in conversational speech. Discrimination performance for covarying F0 and intensity changes was more strongly correlated to identification performance than was found for discrimination of either F0 or intensity alone. Syllable duration was not related to stress identification in natural utterances. CONCLUSIONS: The outcome emphasizes the importance of both F0 and intensity for CI users' identification of sentence-based stress. Both cues were used separately for stress perception, but combining the cues provided extra benefit for most of the subjects.


Assuntos
Implantes Cocleares/psicologia , Surdez/psicologia , Surdez/terapia , Percepção da Fala , Fala , Estresse Psicológico/psicologia , Estimulação Acústica/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Sinais (Psicologia) , Emoções/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fonética , Adulto Jovem
18.
J Acoust Soc Am ; 129(5): EL204-9, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21568376

RESUMO

The corruption of intonation contours has detrimental effects on sentence-based speech recognition in normal-hearing listeners Binns and Culling [(2007). J. Acoust. Soc. Am. 122, 1765-1776]. This paper examines whether this finding also applies to cochlear implant (CI) recipients. The subjects' F0-discrimination and speech perception in the presence of noise were measured, using sentences with regular and inverted F0-contours. The results revealed that speech recognition for regular contours was significantly better than for inverted contours. This difference was related to the subjects' F0-discrimination providing further evidence that the perception of intonation patterns is important for the CI-mediated speech recognition in noise.


Assuntos
Implantes Cocleares , Perda Auditiva Neurossensorial/fisiopatologia , Ruído , Mascaramento Perceptivo/fisiologia , Fonética , Percepção da Fala , Adolescente , Adulto , Idoso , Feminino , Perda Auditiva Neurossensorial/psicologia , Perda Auditiva Neurossensorial/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Distribuição Aleatória , Testes de Discriminação da Fala , Inteligibilidade da Fala , Percepção da Fala/fisiologia , Adulto Jovem
19.
JASA Express Lett ; 1(7): 075201, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-36154643

RESUMO

Situations with multiple competing talkers are especially challenging for listeners with hearing impairment. These "cocktail party" situations can either be static (fixed target talker) or dynamic (changing target talker). Relative to static situations, dynamic listening is typically associated with increased cognitive load and decreased speech recognition ("costs"). This study addressed the role of hearing impairment and cognition in two groups of older listeners with and without hearing loss. In most of the dynamic situations, the costs did not differ between the listener groups. There was no clear evidence that overall costs show an association with the individuals' cognitive abilities.


Assuntos
Perda Auditiva , Percepção da Fala , Estimulação Acústica , Cognição , Humanos , Mascaramento Perceptivo
20.
J Speech Lang Hear Res ; 63(12): 4325-4326, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-33237832

RESUMO

Purpose The purpose of this letter is to compare results by Skuk et al. (2020) with Meister et al. (2016) and to point to a potential general influence of stimulus type. Conclusion Our conclusion is that presenting sentences may give cochlear implant recipients the opportunity to use timbre cues for voice perception. This might not be the case when presenting brief and sparse stimuli such as consonant-vowel-consonant or single words, which were applied in the majority of studies.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Voz , Sinais (Psicologia) , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA