Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 27(1): 345-353, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27003140

RESUMO

OBJECTIVES: To examine repeatability of parameters derived from non-Gaussian diffusion models in data acquired in children with solid tumours. METHODS: Paediatric patients (<16 years, n = 17) were scanned twice, 24 h apart, using DWI (6 b-values, 0-1000 mm-2 s) at 1.5 T in a prospective study. Tumour ROIs were drawn (3 slices) and all data fitted using IVIM, stretched exponential, and kurtosis models; percentage coefficients of variation (CV) calculated for each parameter at all ROI histogram centiles, including the medians. RESULTS: The values for ADC, D, DDCα, α, and DDCK gave CV < 10 % down to the 5th centile, with sharp CV increases below 5th and above 95th centile. K, f, and D* showed increased CV (>30 %) over the histogram. ADC, D, DDCα, and DDCK were strongly correlated (ρ > 0.9), DDCα and α were not correlated (ρ = 0.083). CONCLUSION: Perfusion- and kurtosis-related parameters displayed larger, more variable CV across the histogram, indicating observed clinical changes outside of D/DDC in these models should be interpreted with caution. Centiles below 5th for all parameters show high CV and are unreliable as diffusion metrics. The stretched exponential model behaved well for both DDCα and α, making it a strong candidate for modelling multiple-b-value diffusion imaging data. KEY POINTS: • ADC has good repeatability as low 5th centile of the histogram distribution. • High CV was observed for all parameters at extremes of histogram. • Parameters from the stretched exponential model showed low coefficients of variation. • The median ADC, D, DDC α , and DDC K are highly correlated and repeatable. • Perfusion/kurtosis parameters showed high CV variations across their histogram distributions.


Assuntos
Imagem de Difusão por Ressonância Magnética/estatística & dados numéricos , Modelos Teóricos , Neoplasias/diagnóstico por imagem , Adolescente , Criança , Estudos de Coortes , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes
2.
Pediatr Blood Cancer ; 64(2): 279-283, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27615273

RESUMO

Diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) have been used as imaging biomarkers in adults with high-grade gliomas (HGGs). We incorporated free-breathing DW-MRI and DCE-MRI, at a single time point, in the routine follow-up of five children (median age 9 years, range 8-15) with histologically confirmed HGG within a prospective imaging study. It was feasible to incorporate DW-MRI and DCE-MRI in routine assessments of children with HGG. DW and DCE parameters were repeatable in paediatric HGG. Higher median ADC100-1000 significantly correlated with longer survival in our sample.


Assuntos
Neoplasias Encefálicas/diagnóstico , Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Glioma/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Adolescente , Adulto , Neoplasias Encefálicas/diagnóstico por imagem , Criança , Estudos de Viabilidade , Feminino , Seguimentos , Glioma/diagnóstico por imagem , Humanos , Masculino , Gradação de Tumores , Prognóstico , Adulto Jovem
3.
Eur Radiol ; 25(9): 2641-50, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25773937

RESUMO

OBJECTIVES: The objectives are to examine the reproducibility of functional MR imaging in children with solid tumours using quantitative parameters derived from diffusion-weighted (DW-) and dynamic contrast enhanced (DCE-) MRI. METHODS: Patients under 16-years-of age with confirmed diagnosis of solid tumours (n = 17) underwent free-breathing DW-MRI and DCE-MRI on a 1.5 T system, repeated 24 hours later. DW-MRI (6 b-values, 0-1000 sec/mm(2)) enabled monoexponential apparent diffusion coefficient estimation using all (ADC0-1000) and only ≥100 sec/mm(2) (ADC100-1000) b-values. DCE-MRI was used to derive the transfer constant (K(trans)), the efflux constant (kep), the extracellular extravascular volume (ve), and the plasma fraction (vp), using a study cohort arterial input function (AIF) and the extended Tofts model. Initial area under the gadolinium enhancement curve and pre-contrast T1 were also calculated. Percentage coefficients of variation (CV) of all parameters were calculated. RESULTS: The most reproducible cohort parameters were ADC100-1000 (CV = 3.26%), pre-contrast T1 (CV = 6.21%), and K(trans) (CV = 15.23%). The ADC100-1000 was more reproducible than ADC0-1000, especially extracranially (CV = 2.40% vs. 2.78%). The AIF (n = 9) derived from this paediatric population exhibited sharper and earlier first-pass and recirculation peaks compared with the literature's adult population average. CONCLUSIONS: Free-breathing functional imaging protocols including DW-MRI and DCE-MRI are well-tolerated in children aged 6 - 15 with good to moderate measurement reproducibility. KEY POINTS: • Diffusion MRI protocol is feasible and well-tolerated in a paediatric oncology population. • DCE-MRI for pharmacokinetic evaluation is feasible and well tolerated in a paediatric oncology population. • Paediatric arterial input function (AIF) shows systematic differences from the adult population-average AIF. • Variation of quantitative parameters from paired functional MRI measurements were within 20%.


Assuntos
Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem , Neoplasias/diagnóstico , Adolescente , Criança , Estudos de Coortes , Estudos de Viabilidade , Feminino , Gadolínio , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Respiração , Sensibilidade e Especificidade
4.
Eur Radiol ; 19(11): 2728-38, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19547986

RESUMO

The purpose was to determine the reproducibility of apparent diffusion coefficient (ADC) measurements in a two-centre phase I clinical trial; and to track ADC changes in response to the sequential administration of the vascular disrupting agent, combretastatin A4 phosphate (CA4P), and the anti-angiogenic drug, bevacizumab. Sixteen patients with solid tumours received CA4P and bevacizumab treatment. Echo-planar diffusion-weighted MRI was performed using six b values (b = 0-750 s/mm(2)) before (x2), and at 3 and 72 h after a first dose of CA4P. Bevacizumab was given 4 h after a second dose of CA4P, and imaging performed 3 h post CA4P and 72 h after bevacizumab treatment. The coefficient of repeatability (r) of ADC total (all b values), ADC high (b = 100-750) and ADC low (b = 0-100) was calculated by Bland-Altman analysis. The ADC total and ADC high showed good measurement reproducibility (r% = 13.3, 14.1). There was poor reproducibility of the perfusion-sensitive ADC low (r% = 62.5). Significant increases in the median ADC total and ADC high occurred at 3 h after the second dose of CA4P (p < 0.05). ADC measurements were highly reproducible in a two-centre clinical trial setting and appear promising for evaluating the effects of drugs that target tumour vasculature.


Assuntos
Anticorpos Monoclonais/farmacologia , Imageamento por Ressonância Magnética/métodos , Neoplasias/tratamento farmacológico , Neoplasias/patologia , Estilbenos/farmacologia , Adulto , Idoso , Inibidores da Angiogênese/farmacologia , Anticorpos Monoclonais Humanizados , Bevacizumab , Imagem de Difusão por Ressonância Magnética/métodos , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Fatores de Tempo
5.
PLoS One ; 11(3): e0152152, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27011312

RESUMO

OBJECTIVES: To evaluate sources of error in the Magnetic Resonance Imaging (MRI) measurement of percent fibroglandular tissue (%FGT) using two-point Dixon sequences for fat-water separation. METHODS: Ten female volunteers (median age: 31 yrs, range: 23-50 yrs) gave informed consent following Research Ethics Committee approval. Each volunteer was scanned twice following repositioning to enable an estimation of measurement repeatability from high-resolution gradient-echo (GRE) proton-density (PD)-weighted Dixon sequences. Differences in measures of %FGT attributable to resolution, T1 weighting and sequence type were assessed by comparison of this Dixon sequence with low-resolution GRE PD-weighted Dixon data, and against gradient-echo (GRE) or spin-echo (SE) based T1-weighted Dixon datasets, respectively. RESULTS: %FGT measurement from high-resolution PD-weighted Dixon sequences had a coefficient of repeatability of ±4.3%. There was no significant difference in %FGT between high-resolution and low-resolution PD-weighted data. Values of %FGT from GRE and SE T1-weighted data were strongly correlated with that derived from PD-weighted data (r = 0.995 and 0.96, respectively). However, both sequences exhibited higher mean %FGT by 2.9% (p < 0.0001) and 12.6% (p < 0.0001), respectively, in comparison with PD-weighted data; the increase in %FGT from the SE T1-weighted sequence was significantly larger at lower breast densities. CONCLUSION: Although measurement of %FGT at low resolution is feasible, T1 weighting and sequence type impact on the accuracy of Dixon-based %FGT measurements; Dixon MRI protocols for %FGT measurement should be carefully considered, particularly for longitudinal or multi-centre studies.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Adulto , Mama/patologia , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade
6.
Lymphat Res Biol ; 13(2): 100-6, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25774851

RESUMO

BACKGROUND: Contrast-Enhanced Magnetic Resonance Lymphangiography (CE-MRL) presents some limitations: (i) it does not quantify lymphatic functionality; and (ii) enhancement of vascular structures may confound image interpretation. Furthermore, although CE-MRL is well described in the published literature for the lower limbs, there is a paucity of data with regards to its use in the upper limbs. In this proof-of-principle study, we propose a new protocol to perform CE-MRL in the upper limbs of patients with breast cancer-related lymphedema (BCRL) which addresses these limitations. METHODS AND RESULTS: CE-MRL was performed using a previously published (morphological) protocol and the proposed protocol (quantitative) on both the ipsilateral (abnormal) and contralateral (normal) arms of patients with BCRL. The quantitative protocol employs contrast agent (CA) intradermal injections at a lower concentration to prevent T2*-related signal decay. Both protocols provided high-resolution three-dimensional images of upper limb lymphatic vessels. CA uptake curves were utilized to distinguish between lymphatic vessels and vascular structures. The quantitative protocol minimized venous enhancement and avoided spurious delays in lymphatic enhancement due to short T2* values, enabling correct CA uptake characterization. The quantitative protocol was therefore employed to measure the lymphatic fluid velocity, which demonstrated functional differences between abnormal and normal arms. The velocity values were in agreement with previously reported lymphoscintigraphy and near infra-red lymphangiography measurements. CONCLUSIONS: This work demonstrated the feasibility of CE-MRL of the upper limbs in patients with BRCL, introducing an advanced imaging and analysis protocol suitable for anatomical and functional study of the lymphatic system.


Assuntos
Neoplasias da Mama/complicações , Linfedema/diagnóstico , Linfedema/etiologia , Linfografia/métodos , Angiografia por Ressonância Magnética , Extremidade Superior/patologia , Meios de Contraste , Feminino , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Vasos Linfáticos/patologia , Pessoa de Meia-Idade
7.
J Dev Behav Pediatr ; 24(1): 17-23, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12584481

RESUMO

To determine fetal growth and the incidence of withdrawal symptoms in term infants exposed to methamphetamine in utero, we retrospectively identified neonates whose mothers used methamphetamine during pregnancy and matched them to unexposed newborns. Exclusion criteria included multiple and preterm gestations. Although there were no differences in infant growth parameters between the methamphetamine-exposed and methamphetamine-unexposed neonates, methamphetamine exposure throughout gestation was associated with decreased growth relative to infants exposed only for the first two trimesters. In addition, there were significantly more small for gestational age infants in the methamphetamine group compared with the unexposed group. Methamphetamine-exposed infants whose mothers smoked had significantly decreased growth relative to infants exposed to methamphetamine alone. Withdrawal symptoms (as determined by a previously reported scoring system) requiring pharmacologic intervention were observed in 4% of methamphetamine-exposed infants. These preliminary findings indicate that methamphetamine use is associated with growth restriction in infants born at term.


Assuntos
Transtornos Relacionados ao Uso de Anfetaminas/complicações , Desenvolvimento Embrionário e Fetal/efeitos dos fármacos , Metanfetamina/efeitos adversos , Síndrome de Abstinência Neonatal , Peso ao Nascer/efeitos dos fármacos , Feminino , Idade Gestacional , Crescimento/efeitos dos fármacos , Humanos , Recém-Nascido , Gravidez , Resultado da Gravidez , Estudos Retrospectivos
8.
Acad Radiol ; 21(11): 1394-401, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25179563

RESUMO

RATIONALE AND OBJECTIVES: To retrospectively investigate the effect of flip angle (FA) and k-space sampling on the performance of dynamic contrast-enhanced (DCE-) magnetic resonance imaging (MRI) breast sequences. MATERIALS AND METHODS: Five DCE-MRI breast sequences were evaluated (10°, 14°, and 18° FAs; radial or linear k-space sampling), with 7-10 patients in each group (n = 45). All sequences were compliant with current technical breast screening guidelines. Contrast agent (CA) uptake curves were constructed from the right mammary artery for each examination. Maximum relative enhancement, E(max), and time-to-peak enhancement, T(max), were measured and compared between protocols (analysis of variance and Mann-Whitney). For each sequence, calculated values of maximum relative enhancement, E(calc), were derived from the Bloch equations and compared to E(max). Fat suppression performance (residual bright fat and chemical shift artifact) was rated for each examination and compared between sequences (Fisher exact tests). RESULTS: Significant differences were identified between DCE-MRI sequences. E(max) increased significantly at higher FAs and with linear k-space sampling (P < .0001; P = .001). Radial protocols exhibited greater T(max) than linear protocols at FAs of both 14° (P = .025) and 18° (P < .0001), suggesting artificially flattened uptake curves. Good correlation was observed between E(calc) and E(max) (r = 0.86). Fat suppression failure was more pronounced at an FA of 18° (P = .008). CONCLUSIONS: This retrospective approach is validated as a tool to compare and optimize breast DCE-MRI sequences. Alterations in FA and k-space sampling result in significant differences in CA uptake curve shape which could potentially affect diagnostic interpretation. These results emphasize the need for careful parameter selection and greater standardization of breast DCE-MRI sequences.


Assuntos
Algoritmos , Neoplasias da Mama/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Meglumina , Compostos Organometálicos , Processamento de Sinais Assistido por Computador , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA