Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artif Organs ; 48(1): 37-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37846614

RESUMO

BACKGROUND: The artificial anal sphincter (AAS) system has gained significant attention as a solution for treating fecal incontinence (FI). It relies on transcutaneous energy transfer (TET) as its primary energy source. However, changes in posture or biological tissue can cause misalignment of the coil, resulting in unstable power reception. Inadequate power affects charging efficiency, while excessive power leads to excessive heating at the receiver side. Consequently, achieving safe and constant voltage charging for the AAS becomes a complex challenge. METHODS: To maintain a consistent charging voltage and overcome the issue of variations in load and coil coupling strength, this article proposes a wireless charging control system that utilizes an LCC-S-type resonant network and phase shift to adjust the transmitting voltage based on feedback charging voltage in real time. In particular, the PI controller and neural network are introduced to change the phase-shift angle swiftly. The dynamic performance is then evaluated under different misalignments and presented with comparative results. RESULTS: The results indicate that the multilayer perceptron control system outperforms the PI. Under the complex misalignment disturbance, the average error of receiver side load voltage is only 0.007 V, with an average settling time of 960 ms. Additionally, the average temperature at the receiver side is 40.4°C. CONCLUSION: The experiments demonstrate that the proposed system effectively addresses the misalignment issue in TET during the charging, ensuring constant voltage charging at the receiver side and thermal safety.


Assuntos
Órgãos Artificiais , Esfíncter Urinário Artificial , Canal Anal/cirurgia , Transferência de Energia , Redes Neurais de Computação
2.
Sensors (Basel) ; 24(16)2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39205088

RESUMO

Piezoresistive pressure sensors have broad applications but often face accuracy challenges due to temperature-induced drift. Traditional compensation methods based on discrete data, such as polynomial interpolation, support vector machine (SVM), and artificial neural network (ANN), overlook the thermal hysteresis, resulting in lower accuracy. Considering the sequence-dependent nature of temperature drift, we propose the RF-IWOA-GRU temperature compensation model. Random forest (RF) is used to interpolate missing values in continuous data. A combination of gated recurrent unit (GRU) networks and an improved whale optimization algorithm (IWOA) is employed for temperature compensation. This model leverages the memory capability of GRU and the optimization efficiency of the IWOA to enhance the accuracy and stability of the pressure sensors. To validate the compensation method, experiments were designed under continuous variations in temperature and actual pressure. The experimental results show that the compensation capability of the proposed RF-IWOA-GRU model significantly outperforms that of traditional methods. After compensation, the standard deviation of pressure decreased from 10.18 kPa to 1.14 kPa, and the mean absolute error and root mean squared error were reduced by 75.10% and 76.15%, respectively.

3.
Artif Organs ; 47(11): 1710-1719, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37680050

RESUMO

BACKGROUND: Artificial anal sphincter is an implantable medical device for treating fecal incontinence. Reasonable simulation facilitates the advancement of research and reduces experiments on biological tissue. However, the device's clamping motion and sensor interaction with the intestine in the simulation still require further exploration. This article presents a simulation of the artificial anal sphincter's clamping and sensing and its interaction with the intestinal environment using the Simulation Open Framework Architecture (SOFA). METHODS: Firstly, the proposed simulation algorithm and its principles in SOFA are analyzed. Secondly, the clamping motion and sensor system of the artificial anal sphincter are simulated. Thirdly, a finite element model of intestine is established based on the properties of intestinal soft tissue. Finally, the in vitro experiments are performed. RESULTS: The simulation results indicate that the sensor system of the artificial anal sphincter has good sensing performance during the clamping motion and fecal accumulation process. Experiments have shown that optimal sensory capabilities can be achieved as the posture of the artificial anal sphincter with a roll angle between 20° and 40°. The comparison demonstrates a mean absolute error of 10%-20% between simulation and in vitro experimental results for sensor forces, which verifies the effectiveness of the simulation. CONCLUSION: The proposed novel simulation achieves a more comprehensive interaction between the artificial anal sphincter motion and intestinal environment. This study may provide more effective simulation data for guidance in improving the performance of sensor perception of artificial anal sphincter for further research.


Assuntos
Órgãos Artificiais , Incontinência Fecal , Esfíncter Urinário Artificial , Humanos , Canal Anal/cirurgia , Próteses e Implantes , Incontinência Fecal/cirurgia
5.
Mol Cancer ; 21(1): 4, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-34980131

RESUMO

BACKGROUND: Camrelizumab plus chemotherapy significantly prolonged progression-free survival (PFS) and overall survival (OS) compared to chemotherapy alone as first-line treatment in advanced lung squamous cell carcinoma (LUSC) in the phase III trial (CameL-sq), which has become an option of standard-of-cares for Chinese patients with advanced LUSC. However, the predictive biomarkers remain unknown. METHODS: Tumor tissue samples at baseline, and peripheral blood samples at baseline (pretreatment) and after two cycles of treatment (on-treatment) were prospectively collected from 270 LUSC patients from the CameL-sq study. Blood tumor mutation burden (bTMB) and its dynamics were analyzed to explore their predictive values. RESULTS: Pretreatment bTMB was not associated with objective response, PFS and OS in camrelizumab or placebo plus chemotherapy groups. Low on-treatment bTMB was associated with significantly better objective response (73.8% vs 27.8%, P < 0.001), PFS (median, 9.1 vs 4.1 months; P < 0.001) and OS (median, not reached vs 8.0 months; P < 0.001) in camrelizumab plus chemotherapy group whereas it did not correlate with objective response and PFS in chemotherapy alone group. Importantly, on-treatment bTMB level could discriminate patients of initially radiological stable disease who would long-term benefit from camrelizumab plus chemotherapy (low vs high, median OS, 18.2 vs 7.8 months; P = 0.001). Combing on-treatment bTMB and its dynamics improved the ability for predicting the efficacy of camrelizumab plus chemotherapy. CONCLUSION: On-treatment bTMB together with its dynamics could serve as a predictive biomarker for camrelizumab plus chemotherapy in patients with advanced LUSC. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03668496.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Biomarcadores Tumorais , Carcinoma de Células Escamosas/sangue , Carcinoma de Células Escamosas/tratamento farmacológico , Ácidos Nucleicos Livres , Neoplasias Pulmonares/sangue , Neoplasias Pulmonares/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais Humanizados/administração & dosagem , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/etiologia , Terapia Combinada , Biologia Computacional/métodos , DNA de Neoplasias , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/etiologia , Masculino , Pessoa de Meia-Idade , Terapia de Alvo Molecular/métodos , Mutação , Estadiamento de Neoplasias , Prognóstico , Resultado do Tratamento
6.
Artif Organs ; 46(12): 2391-2399, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35866428

RESUMO

BACKGROUND: Artificial organs are playing an increasingly important role in medical field. Artificial anal sphincter, as an example, is a widely used medical device for fecal incontinence. Though it could help patients maintain continence, the issue of perception reconstruction is still unsolved, which means that patients cannot control defecation as desired. METHODS: In this paper, a novel sensor system based on vector similarity has been analyzed and evaluated. The sensor system is a self-packaged strain gauge sensor with a small size 14.5 mm × 6 mm, especially for medical device implanted in body to reconstruct perception function. In order to overcome the disadvantages of single threshold judgment, a more accurate and reliable judgment standard for content pressure detection in rectum is developed by using vector similarity method. Therefore, in the novel sensor system, standard multi-parameters are comprehensive considered. Furthermore, weight-optimization of sensors are investigated since each sensor has played a different role in detection. Finally, sensor calibration, in vitro and in vivo experiments are established. RESULTS: In sensor calibration, the result R2 > 0.99 presents the strain gauge pressure sensor has a good linearity. After that, a series of in vitro experiments have been conducted. The optimized sensor system shows a high accuracy rate in perception reconstruction, which is 87.5% on early warning and 95% on the alarm. In the following in vivo experiments. The results indicate that the average accuracy of the proposed perception reconstruction module has increased by 17.7%, compared with that without optimized sensor system. CONCLUSIONS: All of these have proven that the novel perception reconstruction module with sensor system based on vector similarity is more acceptable and reliable.


Assuntos
Órgãos Artificiais , Incontinência Fecal , Humanos , Canal Anal/cirurgia , Incontinência Fecal/cirurgia , Reto/cirurgia , Percepção
7.
PLoS Genet ; 15(2): e1007888, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30707694

RESUMO

Brain metastasis (BM) is a major complication of lung adenocarcinoma (LAD). An investigation of the pathogenic mechanisms of BM, as well as the identification of appropriate molecular markers, is necessary. The aim of this study was to determine the expression patterns of microRNAs (miRNAs) in LAD with BM, and to investigate the biological role of these miRNAs during tumorigenesis. miRNA array profiles were used to identify BM-associated miRNAs. These miRNAs were independently validated in 155 LAD patients. Several in vivo and in vitro assays were performed to verify the effects of miRNAs on BM. We identified six miRNAs differentially expressed in patients with BM as compared to patients with BM. Of these, miR-4270 and miR-423-3p were further investigated. miR-4270 and miR-423-3p directly targeted MMP19 and P21, respectively, to influence cell viability, migration, and colony formation in vitro. miR-4270 downregulation and miR-423-3p upregulation was associated with an increased risk of BM in LAD patients. Thus, our results suggested that miR-4270 and miR-423-3p might play an important role in BM pathogenesis in LAD patients, and that these miRNAs might be useful prognostic and clinical treatment targets.


Assuntos
Adenocarcinoma de Pulmão/genética , Neoplasias Encefálicas/genética , Neoplasias Pulmonares/genética , MicroRNAs/genética , Adenocarcinoma de Pulmão/patologia , Biomarcadores Tumorais/genética , Neoplasias Encefálicas/patologia , Carcinogênese/genética , Carcinogênese/patologia , Movimento Celular/genética , Proliferação de Células/genética , Sobrevivência Celular/genética , Regulação para Baixo/genética , Feminino , Regulação Neoplásica da Expressão Gênica/genética , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Regulação para Cima/genética
8.
Artif Organs ; 45(8): E293-E303, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33527366

RESUMO

An artificial anal sphincter is a device to help patients with fecal incontinence rebuild the ability to control the excrement through the anus. In this article, an artificial anal sphincter based on a novel clamping mechanism (AASNCM) is proposed to improve the safety and reliability. The AASNCM, which is powered by a transcutaneous energy transfer system, consists of a novel clamping mechanism, a receiving coil and a control unit. According to design requirements, the novel clamping mechanism model was established. After that, its kinematics and dynamics were analyzed. The results of force tests on the prototype AASNCM show that the maximum values of clamping force and expanding force are 15.859 and 31.029 N, respectively. Comparing the experimental results with theoretical analysis, a good match can be concluded. Finally, in vitro experiments were conducted, and have verified the safety and reliability of the proposed AASNCM.


Assuntos
Canal Anal/fisiopatologia , Canal Anal/cirurgia , Órgãos Artificiais , Incontinência Fecal/cirurgia , Desenho de Prótese , Implantação de Prótese/métodos , Humanos , Técnicas In Vitro
9.
Int J Colorectal Dis ; 35(1): 29-34, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31758247

RESUMO

OBJECTIVE: The evaluation of GI-pill gastrointestinal electronic capsule for colonic transit test in patients with slow transit constipation (STC) was studied. MATERIALS AND METHODS: STC patients (n = 162) were randomly divided into experimental group (n = 84, orally taken GI-pill gastrointestinal electronic capsule and X-ray granule capsule) and control group (n = 78, orally taken X-ray granule capsule). Comparison of the time in colonic transit test between the two groups was conducted. The data of GI-pill gastrointestinal electronic capsule in vivo time, time of capsule passing through the colon, the number of high amplitude propagating contractions (HAPCs), and physiological response ratio were analyzed. RESULTS: There were no significant differences in the whole colonic transit test time, right colonic transit time, left colonic transit time, and rectosigmoid colonic transit time between experimental group and control group (p > 0.05). All patients had no abdominal pain, nausea, vomiting, black stool, difficulty in electronic capsule excretion, or any other discomfort during the test. CONCLUSION: GI-pill gastrointestinal electronic capsule can continuously evaluate the dynamic characteristics of digestive tract in STC patients and is consistent with X-ray granule capsule, which is meaningful to clinical application.


Assuntos
Constipação Intestinal/diagnóstico , Constipação Intestinal/fisiopatologia , Eletrônica , Trânsito Gastrointestinal/fisiologia , Adulto , Idoso , Cápsulas , Estudos de Casos e Controles , Constipação Intestinal/diagnóstico por imagem , Feminino , Humanos , Concentração de Íons de Hidrogênio , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Pressão , Temperatura , Fatores de Tempo , Adulto Jovem
10.
Artif Organs ; 44(7): E300-E312, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31970792

RESUMO

While fecal incontinence (FI) is not fatal, it can dramatically decrease the patient's quality of life. An artificial anal sphincter (AAS) is an implantable device that treats FI by replacing a diseased or damaged anal sphincter, thus allowing the patient's continence to be maintained. Here, we report a novel implantable puborectalis-like artificial anal sphincter (PAAS) that replicates rectal perception and has a low risk of ischemia necrosis. Using the pressure sensors embedded in the PAAS, the relationship between the mass of feces and the pressure was determined, and a feces mass estimation model was developed based on in vitro studies. Rectal perception is provided through the real-time monitoring of rectal feces, and the feeling of defecation is quantified based on a comparison between the feces mass and a preset threshold mass. In vivo studies were performed for validation, and the accuracy of the model was determined to be as high as 90%. The performance of the PAAS in the real-time monitoring of rectal feces and its in vivo biocompatibility were also evaluated. The device should further the functionality of existing AAS systems while improving their biosafety and thus expand the applicability of implantable AAS systems in the treatment of FI.


Assuntos
Canal Anal/cirurgia , Órgãos Artificiais , Incontinência Fecal/cirurgia , Desenho de Prótese , Implantação de Prótese/instrumentação , Canal Anal/fisiologia , Animais , Defecação/fisiologia , Modelos Animais de Doenças , Humanos , Teste de Materiais , Pressão , Qualidade de Vida , Suínos , Porco Miniatura
11.
Zhongguo Yi Liao Qi Xie Za Zhi ; 44(4): 288-293, 2020 Apr 08.
Artigo em Zh | MEDLINE | ID: mdl-32762199

RESUMO

A wearable wireless health monitoring system for drug addicts in compulsory rehabilitation centers was proposed. The system can continuously monitor multiple physiological parameters of drug addicts in real time, and issue early warning information when abnormal physiological parameters occur, so as to play the role of timely medical practice. In addition, this study proposes a convolutional neural network (CNN)model, which can evaluate the health status of drug addicts based on multiple physiological parameters. Experiments show that the model can be applied to the task of body state recognition in the open physiological parameter data set, and the recognition accuracy can reach up to 100% in a single physiological parameter data set; when the whole physiological data set is used, the recognition accuracy can reach 99.1%. The recognition accuracy exceeds the performance of the traditional pattern recognition method on this task, which verifies the superiority of the model.


Assuntos
Algoritmos , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia , Monitorização Fisiológica , Redes Neurais de Computação
12.
Artif Organs ; 43(6): E109-E123, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30480825

RESUMO

Puborectalis-like artificial anal sphincter (PAAS) is an innovative new type of artificial anal sphincter (AAS). It overcomes many drawbacks and inadequacies of various previous AASs, and it has successfully been implanted in vivo for almost 3 weeks. During in vivo testing, PAAS shows its ability to retain continence with low risk of ischemia necrosis, and somehow truly helps to remodel rectal perception. However, there are still many defects that influence the long-term implantation of PAAS, especially in the power supply system (PSS). This article presents a new designed PSS which includes a new transcutaneous energy transfer (TET) system, a heat reduction system, and a safety usage system. The new PSS reduces the total size of PAAS by at least 30%. Newly designed TET system can satisfy the Qi standard, and render a power of 3W to fulfill the requirement of fast charging and normal use of PAAS at the distance of 15.5 mm when frequency of TET system is 110 kHz, which previous TET systems can hardly achieve. Heat reduction system helps to reduce the heat generated during TET charging. It can reduce heat by 40% during the same period of time of TET charging. Safety usage system helps the user control PAAS more properly which can reduce the rate of failure of PAAS system.


Assuntos
Canal Anal , Órgãos Artificiais , Canal Anal/cirurgia , Animais , Fontes de Energia Elétrica , Transferência de Energia , Temperatura Alta , Desenho de Prótese , Falha de Prótese , Implantação de Prótese , Suínos
13.
Microsc Microanal ; 24(3): 264-276, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29877171

RESUMO

To solve extended acquisition time issues inherent in the conventional hopping-scanning mode of scanning ion-conductance microscopy (SICM), a new transverse-fast scanning mode (TFSM) is proposed. Because the transverse motion in SICM is not the detection direction and therefore presents no collision problem, it has the ability to move at high speed. In TSFM, the SICM probe gradually descends in the vertical/detection direction and rapidly scans in the transverse/nondetection direction. Further, the highest point that decides the hopping height of each scanning line can be quickly obtained. In conventional hopping mode, however, the hopping height is artificially set without a priori knowledge and is typically very large. Consequently, TFSM greatly improves the scanning speed of the SICM imaging system by effectively reducing the hopping height of each pixel. This study verifies the feasibility of this novel scanning method via theoretical analysis and experimental study, and compares the speed and quality of the scanning images obtained in the TFSM with that of the conventional hopping mode. The experimental results indicate that the TFSM method has a faster scanning speed than other SICM scanning methods while maintaining the quality of the images. Therefore, TFSM provides the possibility to quickly obtain high-resolution three-dimensional topographical images of extremely complex samples.

14.
Artif Organs ; 39(7): 615-26, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25808086

RESUMO

Transcutaneous energy transfer system (TETS) is widely used to energize implantable biomedical devices. As a key part of the TETS, a pair of applicable coils with low losses, high unloaded Q factor, and strong coupling is required to realize an efficient TETS. This article presents an optimal design methodology of planar litz wire coils sandwiched between two ferrite substrates wirelessly powering a novel mechanical artificial anal sphincter system for treating severe fecal incontinence, with focus on the main parameters of the coils such as the wire diameter, number of turns, geometry, and the properties of the ferrite substrate. The theoretical basis of optimal power transfer efficiency in an inductive link was analyzed. A set of analytical expressions are outlined to calculate the winding resistance of a litz wire coil on ferrite substrate, taking into account eddy-current losses, including conduction losses and induction losses. Expressions that describe the geometrical dimension dependence of self- and mutual inductance are derived. The influence of ferrite substrate relative permeability and dimensions is also considered. We have used this foundation to devise an applicable coil design method that starts with a set of realistic constraints and ends with the optimal coil pair geometries. All theoretical predictions are verified with measurements using different types of fabricated coils. The results indicate that the analysis is useful for optimizing the geometry design of windings and the ferrite substrate in a sandwich structure as part of which, in addition to providing design insight, allows speeding up the system efficiency-optimizing design process.


Assuntos
Canal Anal/fisiologia , Órgãos Artificiais , Incontinência Fecal/terapia , Canal Anal/anatomia & histologia , Fontes de Energia Elétrica , Transferência de Energia , Desenho de Equipamento , Compostos Férricos/química , Humanos , Desenho de Prótese , Tecnologia sem Fio
15.
J Environ Sci (China) ; 34: 212-8, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-26257364

RESUMO

This study took advantage of resorufin cellobioside as a fluorescent substrate to determine the distribution of cellulase activity in cellulosic biomass fermentation systems. Cellulolytic biofilms were found to express nearly four orders greater cellulase activity compared to planktonic cultures of Clostridium thermocellum and Caldicellulosiruptor obsidiansis, which can be primarily attributed to the high cell concentration and surface attachment. The formation of biofilms results in cellulases being secreted close to their substrates, which appears to be an energetically favorable stategy for insoluble substrate utilization. For the same reason, cellulases should be closely associated with the surfaces of suspended cell in soluble substrate-fed culture, which has been verified with cellobiose-fed cultures of C. thermocellum and C. obsidiansis. This study addressed the importance of cellulase activity distribution in cellulosic biomass fermentation, and provided theoretical foundation for the leading role of biofilm in cellulose degradation. System optimization and reactor designs that promote biofilm formation in cellulosic biomass hydrolysis may promise an improved cellulosic biofuel process.


Assuntos
Biofilmes , Celulases/metabolismo , Celulose/metabolismo , Firmicutes/fisiologia , Biocombustíveis/análise , Celulossomas , Clostridium thermocellum/fisiologia , Fermentação , Hidrólise
16.
Zhongguo Yi Liao Qi Xie Za Zhi ; 39(1): 9-12, 2015 Jan.
Artigo em Zh | MEDLINE | ID: mdl-26027285

RESUMO

Because the huge number of images of the digestive tract by Wireless Capsule Endoscopy (WCE) are left to the medical personnels detected by their eyes, huge burden leaves to doctors. This article provides a classification of method based on SVM (Support Vector Machine) for the capsule endoscopy bleeding intelligent recognition. We created a new kind of feature parameter, and the experiment result can reach 83% specificity and 94% sensitivity.


Assuntos
Endoscopia por Cápsula , Hemorragia/diagnóstico , Trato Gastrointestinal/patologia , Humanos , Sensibilidade e Especificidade , Máquina de Vetores de Suporte
17.
Biochem Biophys Res Commun ; 446(4): 1197-203, 2014 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-24680681

RESUMO

BACKGROUND: MicroRNA is a class of small, well-conserved, non-coding RNAs, and could play a potential role as diagnostic and prognostic biomarkers of esophageal cancers. We aimed to review comprehensively the evidence of microRNA as prognostic biomarkers in esophageal cancers. METHODS: Studies were identified by searching PubMed, Embase and Web of Science until November 2013. Descriptive characteristics of studies were described and an additional meta-analysis for specific microRNAs which were studied most frequently was performed. Pooled hazard ratios (HRs) and their corresponding 95% confidence intervals (CIs) were calculated. Fixed model or random model method was chosen depending on the heterogeneity among the studies. RESULTS: Twenty-two studies including a total of 1946 participants were enrolled after a strict filtering and qualifying process. Among 33 prognostic microRNAs identified for esophageal cancer, miR-21 and miR-375 appeared more frequently. The median study size was 70.5 patients (29-249 patients) and the median HR was 3.305 (IQR=1.615-7.31). For the studies evaluating miR-21's association with overall survival (OS), the pooled HR suggested that high level of miR-21 has a negative impact on OS (HR=1.52[1.17-1.98], P=0.001). As for miR-375, the pooled HR for OS (high/low) was 0.53 (95% CI: 0.39-0.73, P<0.001), indicated that low level of miR-375 has a negative impact on OS. These results indicated that microRNAs show promising associations with prognosis in esophageal cancer. Up-regulation of miR-21 and down-regulation of miR-375 can predict unfavourable prognosis in esophageal cancer.


Assuntos
Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/genética , MicroRNAs/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Regulação para Baixo , Esôfago/metabolismo , Esôfago/patologia , Feminino , Regulação Neoplásica da Expressão Gênica , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Análise de Sobrevida , Regulação para Cima
18.
Water Sci Technol ; 69(7): 1482-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24718340

RESUMO

This study provided insight into the characterization of secondary effluent from a wastewater treatment plant located in northeastern China. The secondary effluent was separated into three fractions, the dissolved, the near-colloidal and the suspended, to study their individual characteristics. It revealed that most of the organics in the secondary effluent existed in the dissolved form, accounting for 78.1-86.5% of the total chemical oxygen demand and 82.6-86.6% of the total organic carbon. Results from the molecular weight distribution study further indicated that organics with MW < 1k Da constituted 56.3-62.7% of total organics. Moreover, the particle size distribution study suggested that particles between 2.0 and 6.8 µm in diameter made up 80.0% of the total suspended solids. Both biological oxygen demand/chemical oxygen demand and biological dissolved organic carbon/dissolved organic carbon were measured ranging from 0.2 to 0.3, suggesting the most secondary effluent organics were biologically refractory. This conclusion was further strengthened by the functional groups information obtained from the GC/MS (gas chromatography/mass spectrometry) analysis. The characteristics information revealed from this study will help the design and selection of water quality-specific tertiary treatment technologies for secondary effluent water purification and reuse.


Assuntos
Águas Residuárias/análise , Análise da Demanda Biológica de Oxigênio , China , Cromatografia Gasosa-Espectrometria de Massas , Compostos Orgânicos/análise , Tamanho da Partícula , Purificação da Água
19.
Bioresour Technol ; 409: 131240, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39122129

RESUMO

To promote the sustainability of hydrothermal liquefaction (HTL) for biofuel production, fungal fermentation was investigated to treat HTL aqueous phase (HTLAP) from corn stover. The most promising fungus, Aspergillus niger demonstrated superior tolerance to HTLAP and capability to produce oxalic acid as a value-added product. The fungal-bacterial co-culture of A. niger and Rhodococcus jostii was beneficial at low COD (chemical oxygen demand) loading of 3800 mg/L in HTLAP, achieving 69% COD removal while producing 0.5 g/L oxalic acid and 11% lipid content in microbial biomass. However, higher COD loading of 4500, 6040, and 7800 mg/L significantly inhibited R. jostii, but promoted A. niger growth with increased oxalic acid production while COD removal remained similar (58-65%). Additionally, most total organic carbon (TOC) in HTLAP was transformed into oxalic acid, representing 46-56% of the consumed TOC. These findings highlighted the potential of fungi for bio-upcycling of HTLAP into value-added products.


Assuntos
Aspergillus niger , Técnicas de Cocultura , Zea mays , Zea mays/química , Aspergillus niger/metabolismo , Água/química , Rhodococcus/metabolismo , Ácido Oxálico , Análise da Demanda Biológica de Oxigênio , Fermentação , Biomassa , Fungos/metabolismo , Biocombustíveis
20.
Ultramicroscopy ; 267: 114054, 2024 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-39299030

RESUMO

Scanning ion-conductance microscopy (SICM) is a non-contact, high-resolution, and in-situ scanning probe microscope technique, it can be operated in probing the physical and chemical properties of biological samples such as living cells. Recently, using SICM to study the effects of microenvironment changes such as temperature changes on response of the biological samples has attracted significant attention. However, in this temperature gradient condition, one of the crucial but still unclear issues is the scanning feedback types and safe threshold. In this paper, a theoretical study of effect of the temperature gradient in electrolyte or sample surface on the SICM safe ion-current threshold is conducted using three-dimensional Poisson-Nernst-Planck, Navier-Stokes and energy equations. Two temperature gradient types, sample surface and two types of pipettes with different ratio of inner and outer radii are included, respectively. The results demonstrate that the local temperature of the electrolyte and then sample surface significantly affect the ion flow, shape of the approach curves and thus safe threshold in SICM pipette probe for contact-free scanning. There is a current-increased and decreased phases for approaching the surface with higher temperature and two current-decreased phases for surface with lower temperature. Based on this shape feature of approach curves, the change rate of current is analysis to illustrate the possibility for contact-free scanning of slope object. The results indicate that with the decrease of the normalized tip-surface distance, the coupling effect of large slope angle and local high temperature makes the increase in change rate of ion current not significant and then it challenging to realize contact-free scanning especially for higher surface temperature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA