Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Int J Mol Sci ; 22(22)2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34830144

RESUMO

Recently, ferroptosis has gained scientists' attention as an iron-related regulated necrosis. However, not many reports have investigated the effect of ferroptosis on bone. Therefore, with the present study, we assessed the effect of ferroptosis inhibition using ferrostatin-1 on the MC3T3-E1 pre-osteoblast cell. Cell images, cell viability, alkaline phosphatase activity test, alizarin red staining, and RUNX2 gene expression using real-time PCR were applied to investigate the effects of ferrostatin and erastin on MC3T3-E1 osteoblast cells. Erastin was used as a well-known ferroptosis inducer reagent. Erastin with different concentrations ranging from 0 to 50 µmol/L was used for inducing cell death. The 25 µmol/L erastin led to controllable partial cell death on osteoblast cells. Ferrostatin-1 with 0 to 40 µmol/L was used for cell doping and cell death inhibition effect. Ferrostatin-1 also displayed a recovery effect on the samples, which had already received the partially artificial cell death by erastin. Cell differentiation, alizarin red staining, and RUNX2 gene expression confirmed the promotion of the bone formation ability effect of ferrostatin-1 on osteoblast cells. The objective of this study was to assess ferrostatin-1's effect on the MC3T3-E1 osteoblast cell line based on its ferroptosis inhibitory property.


Assuntos
Cicloexilaminas/farmacologia , Ferroptose/efeitos dos fármacos , Osteoblastos/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Fenilenodiaminas/farmacologia , Fosfatase Alcalina/metabolismo , Animais , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Subunidade alfa 1 de Fator de Ligação ao Core/genética , Expressão Gênica/efeitos dos fármacos , Camundongos , Osteoblastos/citologia , Osteoblastos/metabolismo , Piperazinas/farmacologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa
2.
Odontology ; 108(3): 366-375, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31807949

RESUMO

Soft denture liners and tissue conditioners are widely used for the denture patients to cushion masticatory force and condition abused tissues, respectively. This study assessed methods for the evaluation of the viscoelasticity and glass transition temperature (Tg) of the silicone permanent soft liner, acrylic permanent soft liner, and tissue conditioner. Three rheological parameters of storage modulus (E'), loss modulus (E''), and loss tangent ([Formula: see text]), Tg, and hardness were determined using dynamic mechanical analysis (DMA), differential scanning calorimetry (DSC), and the Shore A0 hardness test. Five specimens were measured for each material. The time-temperature superposition principle was applied to produce master curves of E', E'', and [Formula: see text] for the tested materials at a reference temperature of 37 °C. The acrylic permanent soft liner and tissue conditioner exhibited viscoelastic behavior and sensitivity to frequency, especially at lower frequencies. The silicone permanent soft liner showed elastic behavior and was frequency-independent. Tg for the acrylic permanent soft liner was higher than that for the tissue conditioner, which in turn was higher than that for the silicone permanent soft liner for both DMA and DSC. In DMA, a higher frequency led to higher Tg values. A positive linear relationship was found between Shore A0 hardness and E' values, but not E'' and [Formula: see text] values. Shore hardness reflects elasticity, but not viscosity. The results of the present study can be used to improve methods for evaluating the viscoelasticity and Tg of soft denture liners and tissue conditioners.


Assuntos
Reembasadores de Dentadura , Resinas Acrílicas , Elasticidade , Dureza , Humanos , Teste de Materiais , Elastômeros de Silicone , Temperatura , Temperatura de Transição
3.
J Mater Sci Mater Med ; 29(3): 34, 2018 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-29549513

RESUMO

The aim was to investigate the effect of machining instruments on machinability of dental ceramics. Four dental ceramics, including two zirconia ceramics were machined by three types (SiC, diamond vitrified, and diamond sintered) of wheels with a hand-piece engine and two types (diamond and carbide) of burs with a high-speed air turbine. The machining conditions used were abrading speeds of 10,000 and 15,000 r.p.m. with abrading force of 100 gf for the hand-piece engine, and a pressure of 200 kPa and a cutting force of 80 gf for the air-turbine hand-piece. The machinability efficiency was evaluated by volume losses after machining the ceramics. A high-abrading speed had high-abrading efficiency (high-volume loss) compared to low-abrading speed in all abrading instruments used. The diamond vitrified wheels demonstrated higher volume loss for two zirconia ceramics than those of SiC and diamond sintered wheels. When the high-speed air-turbine instruments were used, the diamond points showed higher volume losses compared to the carbide burs for one ceramic and two zirconia ceramics with high-mechanical properties. The results of this study indicated that the machinability of dental ceramics depends on the mechanical and physical properties of dental ceramics and machining instruments. The abrading wheels show autogenous action of abrasive grains, in which ground abrasive grains drop out from the binder during abrasion, then the binder follow to wear out, subsequently new abrasive grains come out onto the instrument surface (autogenous action) and increase the grinding amount (volume loss) of grinding materials.


Assuntos
Cerâmica/química , Equipamentos Odontológicos/efeitos adversos , Materiais Dentários/química , Porcelana Dentária/química , Teste de Materiais , Reparação de Restauração Dentária/instrumentação , Diamante/química , Desenho de Equipamento , Humanos , Teste de Materiais/instrumentação , Teste de Materiais/métodos , Propriedades de Superfície , Zircônio/química
4.
J Mater Sci Mater Med ; 27(1): 3, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26610926

RESUMO

In the present study, sol-gel derived nanoparticle calcium silicate bioactive glass was added to the resin-modified light cure glass-ionomer cement to assess the influence of additional bioactive glass nanoparticles on the mechanical and biological properties of resin-modified glass-ionomer cement. The fabricated bioactive glass nanoparticles added resin-modified glass-ionomer cements (GICs) were immersed in the phosphate buffer solution for 28 days to mimic real condition for the mechanical properties. Resin-modified GICs containing 3, 5 and 10 % bioactive glass nanoparticles improved the flexural strength compared to the resin-modified glass-ionomer cement and the samples containing 15 and 20 % bioactive glass nanoparticles before and after immersing in the phosphate buffer solution. Characterization of the samples successfully expressed the cause of the critical condition for mechanical properties. Cell study clarified that resin-modified glass-ionomer cement with high concentrations of bioactive glass nanoparticles has higher cell viability and better cell morphology compare to control groups. The results for mechanical properties and toxicity approved that the considering in selection of an optimum condition would have been a more satisfying conclusion for this study.


Assuntos
Cimentos de Ionômeros de Vidro , Vidro , Nanopartículas , Microscopia Eletrônica de Varredura , Espectrometria por Raios X
5.
J Mater Sci Mater Med ; 26(1): 5391, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25595723

RESUMO

This study investigated the possibility of electrical and laser welding to connect titanium-based alloy (beta-titanium and nickel-titanium) wires and stainless-steel or cobalt-chromium alloy wires for fabrication of combination arch-wires. Four kinds of straight orthodontic rectangular wires (0.017 × 0.025 inch) were used: stainless-steel (S-S), cobalt-chromium (Co-Cr), beta-titanium alloy (ß-Ti), and nickel-titanium (Ni-Ti). Homogeneous and heterogeneous end-to-end joints (15 mm long each) were made by electrical welding and laser welding. Non-welded wires (30 mm long) were also used as a control. Maximum loads at fracture (N) and elongation (%) were measured by conducting tensile test. The data (n = 10) were statistically analyzed using analysis of variance/Tukey test (P < 0.05).The S-S/S-S and Co-Cr/Co-Cr specimens showed significantly higher values of the maximum load (ML) at fracture and elongation (EL) than those of the Ni-Ti/Ni-Ti and ß-Ti/ß-Ti specimens for electrical welding and those of the S-S/S-S and Co-Cr/Co-Cr specimens welded by laser. On the other hand, the laser-welded Ni-Ti/Ni-Ti and ß-Ti/ß-Ti specimens exhibited higher values of the ML and EL compared to those of the corresponding specimens welded by electrical method. In the heterogeneously welded combinations, the electrically welded Ni-Ti/S-S, ß-Ti/S-S and ß-Ti/Co-Cr specimens showed significantly (P < 0.05) higher ML and EL than those of the corresponding specimens welded by laser. Electrical welding exhibited the higher values of maximum load at fracture and elongation for heterogeneously welded combinations than laser-welding.


Assuntos
Fios Ortodônticos , Ortodontia/instrumentação , Ortodontia/métodos , Titânio/química , Ligas , Cromo/química , Cobalto/química , Humanos , Lasers , Teste de Materiais , Níquel/química , Reprodutibilidade dos Testes , Aço Inoxidável , Estresse Mecânico , Resistência à Tração , Dente
6.
J Biomech Eng ; 136(11)2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25162918

RESUMO

This study compared biomechanical patterns between finite element models (FEMs) and a fresh dog mandible tested under molar and incisal physiological loads in order to clarify the effect of the bone transport distraction osteogenesis (BTDO) surgical process. Three FEMs of dog mandibles were built in order to evaluate the effects of BTDO. The first model evaluated the mandibular response under two physiological loads resembling bite processes. In the second model, a 5.0 cm bone defect was bridged with a bone transport reconstruction plate (BTRP). In the third model, new regenerated bony tissue was incorporated within the defect to mimic the surgical process without the presence of the device. Complementarily, a mandible of a male American foxhound dog was mechanically tested in the laboratory both in the presence and absence of a BTRP, and mechanical responses were measured by attaching rosettes to the bone surface of the mandible to validate the FEM predictions. The relationship between real and predicted values indicates that the stress patterns calculated using FEM are a valid predictor of the biomechanics of the BTDO procedures. The present study provides an interesting correlation between the stiffness of the device and the biomechanical response of the mandible affected for bone transport.


Assuntos
Mandíbula/cirurgia , Fenômenos Mecânicos , Osteogênese por Distração , Animais , Fenômenos Biomecânicos , Cães , Análise de Elementos Finitos , Masculino , Estresse Mecânico
7.
J Craniofac Surg ; 25(3): e233-5, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24777003

RESUMO

Two cases of foreign bodies that were incidentally observed on orthopantomographs are reported in this study. The foreign bodies were analyzed using an x-ray fluorescence spectrometer to identify what the migrated foreign bodies were and what migration pathways they had taken. The removed metallic foreign bodies from the maxillae of 2 patients, who were referred to the Department of Dentistry and Oral Surgery of the University of Fukui Hospital, were analyzed using an x-ray fluorescence spectrometer in the Department of Dental and Biomedical Materials Science, Nagasaki University. The major component of foreign body in patient 1 was silver, and that in case 2 was iron. On the basis of the imaging results and the patients' clinical history, the foreign bodies were considered to be caused by iatrogenic migration. Understanding the existence of foreign bodies and their migration pathway into the jaw bone can thus make clinicians more aware of such migrations and can thereby contribute to reducing iatrogenic accidents.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Migração de Corpo Estranho/diagnóstico por imagem , Achados Incidentais , Mandíbula/diagnóstico por imagem , Maxila/diagnóstico por imagem , Idoso , Corpos Estranhos/cirurgia , Migração de Corpo Estranho/cirurgia , Humanos , Doença Iatrogênica , Ferro/análise , Masculino , Mandíbula/cirurgia , Maxila/cirurgia , Pessoa de Meia-Idade , Agulhas/efeitos adversos , Radiografia Panorâmica/métodos , Prata/análise , Espectrometria por Raios X/métodos , Tomografia Computadorizada por Raios X/métodos , Extração Dentária/efeitos adversos , Extração Dentária/instrumentação
8.
Clin Oral Implants Res ; 24 Suppl A100: 139-44, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22251063

RESUMO

OBJECTIVES: The purpose of this study was to investigate the effect of photo-induced hydrophilic titanium dioxide (TiO2) on serum fibronectin (sFN) attachment, and further to evaluate initial osseointegration responses in the dog mandibles. MATERIALS AND METHODS: To apply the anatase TiO2 film, plasma source ion implantation (PSII) method followed by annealing was employed for the titanium disks and implants, which were then illuminated with UV-A for 24 h for the experimental groups. Non-deposited titanium disks and implants were prepared for the control group. Surface characterization was performed using the interferometer and contact angle analyzer. The attachments of sFN were evaluated using fluorescence emission analysis. Thereafter both groups of implants were placed in the mandible of six beagle dogs. Bone response was investigated with histological and histomorphometrical analyses after periods of 2 and 4 weeks. RESULTS: The experimental groups exhibited strong hydrophilicity under UV-A illumination and showed significant improvement in sFN attachment. And further, the experimental implants enhanced the bone formation with the bone-to-implant contact of 42.7% after 2 weeks of healing (control: 28.4%). CONCLUSIONS: The combined applications of plasma fibronectin and PSII to produce hydrophilic titanium surfaces could accelerate early osseointegration.


Assuntos
Implantes Dentários , Fibronectinas/farmacologia , Mandíbula/cirurgia , Osteogênese/fisiologia , Animais , Cães , Eletroquímica/métodos , Humanos , Interações Hidrofóbicas e Hidrofílicas , Implantes Experimentais , Íons , Espectroscopia Fotoeletrônica , Propriedades de Superfície , Titânio
9.
Am J Dent ; 26(1): 51-5, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23724550

RESUMO

PURPOSE: To investigate the effect of surface polishing and finishing methods on the surface roughness of restorative ceramics. METHODS: Disk specimens were prepared from feldspar-based, lithium disilicate-based, fluorapatite leucite-based and zirconia ceramics. Four kinds of surface polishing/finishing methods evaluated were: Group 1: CONTROL: carborundum points (CP); Group 2: silicon points (SP); Group 3: diamond paste (DP); Group 4: glazing (GZ). Surface roughness was measured using an interferometer and the parameters of Sa (average height deviation of the surface) and St (maximum peak-to-valley height of the surface) were evaluated. Data were statistically analyzed using two-way ANOVA (P < 0.05) followed by post-hoc test. The mean values were also compared by Student's t-test. Specimen surfaces were evaluated by 3-D images using an interferometer. RESULTS: The zirconia showed the least surface roughness (Sa and St) values after grinding with carborundum points. The significantly lowest Sa values and St values were obtained for lithium disilicate and zirconia ceramics surfaces finished with DP and GZ. The fluorapatite leucite ceramic showed significantly reduced Sa and St values from DP to GZ. The feldspathic porcelain showed the highest surface roughness values among all types of ceramics after all of the polishing/finishing procedures.


Assuntos
Cerâmica/química , Materiais Dentários/química , Polimento Dentário/métodos , Porcelana Dentária/química , Silicatos de Alumínio/química , Apatitas/química , Compostos Inorgânicos de Carbono/química , Diamante/química , Humanos , Interferometria/instrumentação , Teste de Materiais , Compostos de Potássio/química , Silício/química , Propriedades de Superfície , Zircônio/química
10.
Nanomaterials (Basel) ; 13(14)2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37513057

RESUMO

Graphene nanoflakes are widely utilized as high-performance molecular devices due to their chemical stability and light weight. In the present study, the interaction of aluminum species with graphene nanoflake (denoted as GR-Al) has been investigated using the density functional theory (DFT) method to elucidate the doping effects of Al metal on the electronic states of GR. The mechanisms of the diffusion of Al on GR surface and the hydrogen storage of GR-Al were also investigated in detail. The neutral, mono-, di-, and trivalent Al ions (expressed as Al, Al+, Al2+, and Al3+, respectively) were examined as the Al species. The DFT calculations showed that the charge transfer interaction between Al and GR plays an important role in the binding of Al species to GR. The diffusion path of Al on GR surface was determined: the barrier heights of Al diffusion were calculated to be 2.1-2.8 kcal mol-1, which are lower than Li+ on GR (7.2 kcal/mol). The possibility of using GR-Al for hydrogen storage was also discussed on the basis of the theoretical results.

11.
RSC Adv ; 13(3): 2181-2189, 2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36712601

RESUMO

Solar-driven interfacial evaporation has gained increasing attention as an emerging and sustainable technology for wastewater treatment and desalinization. The carbon/molybdenum disulfide (C/MoS2) composite has attracted more attention due to its outstanding light absorption capability and optoelectronic properties as a solar steam generator. However, the hydrophobic nature of carbon and MoS2-based materials hinders their wettability, which is crucial to the effective and facile operation of a solar generator of steam. Herein, a pH-controlled hydrothermal method was utilized to deposit a promising photothermal MoS2 coating on melamine-derived carbon foams (CFs). The hydrophilic CF/MoS2 composite, which can easily be floatable on the water surface, is a high-efficiency solar steam evaporator with a rapid increase in temperature under photon irradiation. Due to the localized heat confinement effect, the self-floating composite foam on the surface of water has the potential to produce a significant temperature differential. The porous structure effectively facilitates fast water vapor escape, leading to an impressively high evaporation efficiency of 94.5% under a light intensity of 1000 W m-2.

12.
Front Dent ; 19: 8, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35937153

RESUMO

Objectives: The aim of this study was to assess the microtensile bond strength of three universal adhesives to dentin and enamel. Materials and Methods: Sixty extracted human third molar teeth were chosen and divided into six groups regarding the adhesive (G-Premio Bond, Clearfil S3 Bond or Single Bond) and tooth surface. All the applied bonding agents were universal adhesives. The teeth were polished and the adhesives were applied; then the teeth were restored with composite resin. The samples were mounted in acrylic resin and sectioned. The specimens were subjected to a universal testing machine and the microtensile bond strength was measured. The failure mode of each specimen was determined under a stereomicroscope. Data were analyzed using two-way ANOVA (α=0.05). Results: The microtensile bond strength of G-Premio Bond to enamel and dentin was 11.79±8.27 and 17.55±9.47 MPa, respectively which was not significantly different from the values in Single Bond group (15.59±10.66 and 17.19±10.09 MPa to enamel and dentin, respectively; P>0.05). However, the values for Clearfil S3 Bond were 7.11±4.23 and 7.88±8.83 MPa to enamel and dentin, respectively, which were significantly lower than the values for G-Premio Bond (P<0.05). Scanning electron microscopic (SEM) images showed that the adhesive failure was dominant in both enamel and dentin groups and in all adhesive systems. Conclusion: G-Premio Bond and Single Bond provided higher microtensile bond strength compared with Clearfil S3 Bond. Universal adhesives with their acceptable performance can be applied in self-etch mode on both enamel and dentin.

13.
J Prosthodont ; 20(5): 348-54, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21585587

RESUMO

PURPOSE: To investigate the effects of internally connected engaging component position in screw-retained fixed cantilevered prostheses. MATERIALS AND METHODS: Twenty-one three-unit fixed dental prostheses (FDPs) were cast in high-palladium alloy in three groups. In group A, engaging components were incorporated into the units away from the cantilevered segment; proximal units received nonengaging components. In group B, these positions were reversed. Control specimens were fabricated using all nonengaging components. Specimens were attached to internally connected 3.5 (diameter) × 13 mm (length) implants, torqued to 32 Ncm, and embedded into epoxy resin. Specimens were tested in cyclic fatigue with a 2 Hz sine wave and 0.1 min/max load ratio. Load amplitude started at 1.8 N and increased by 1.8 N every 60 cycles until fracture. Log-rank statistic, ANOVA, Spearman's correlation, and LIFETEST procedures were used to evaluate level of statistical significance within the results. RESULTS: In the control group, the mean number of cycles to fracture was 31,205 ± 2639. Mean axial force at fracture was 932 ± 78 N. In group A, these numbers were 38,160 ± 4292 and 1138 ± 128 N, and in group B, 31,810 ± 3408 and 949 ± 101 N. Statistical significance levels for number of cycles to fracture were: Control versus group A, p = 0.0117, and groups A versus B, p = 0.0156 (statistically significant). Control versus group B, p = 0.357 (not statistically significant). Log-rank statistic for the survival curves is greater than would be expected by chance; there was a statistically significant difference between survival curves (p = 0.012). The location and mode of failure were noteworthy (always in the abutment screw). CONCLUSIONS: The position of the engaging component had significant effects on the results. Within the limitations of this investigation, it can be concluded that using an engaging abutment in a screw-retained fixed cantilevered FDP provides a mechanical advantage, and engaging the implant furthest from the cantilever when designing a screw-retained cantilever FDP increased resistance to fracture of the distal abutment screw.


Assuntos
Projeto do Implante Dentário-Pivô , Prótese Dentária Fixada por Implante , Planejamento de Dentadura , Retenção de Dentadura , Prótese Parcial Fixa , Dente Suporte , Ligas Dentárias/química , Implantes Dentários , Materiais Dentários/química , Falha de Restauração Dentária , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Paládio/química , Estresse Mecânico , Propriedades de Superfície , Análise de Sobrevida , Titânio/química , Torque
14.
J Prosthodont ; 20 Suppl 2: S20-5, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22003878

RESUMO

This case report presents treatment of two patients with the usual characteristics of Cleidocranial Dysostosis. A multidisciplinary approach using the disciplines of prosthodontics, orthodontics, and oral surgery was effected. Exfoliation of the patient's deciduous teeth and failure of permanent anterior tooth eruption led to emotional, social, and self-esteem issues in both patients. Due to the psychosocial issues confronting these two patients, esthetics was addressed prior to active intervention with orthodontics and after some surgical intervention. The use of two interim overdenture prostheses with magnetic retention is described.


Assuntos
Displasia Cleidocraniana/complicações , Planejamento de Dentadura , Revestimento de Dentadura , Prótese Parcial Temporária , Planejamento de Assistência ao Paciente , Equipe de Assistência ao Paciente , Adolescente , Retenção de Dentadura/instrumentação , Feminino , Humanos , Imãs , Masculino , Desenho de Aparelho Ortodôntico , Braquetes Ortodônticos , Extrusão Ortodôntica/instrumentação , Dente Decíduo/cirurgia , Dente Supranumerário/cirurgia , Dente não Erupcionado/terapia
15.
Eur J Prosthodont Restor Dent ; 19(1): 2-6, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21528680

RESUMO

This study investigated the effect of laser treatment on the fatigue resistance of a 3.5-mm diameter implant with an internal trilobe connection. Twenty two implants were embedded into acrylic resin blocks. Half the specimens were used as control group, and the other half were laser treated circumferentially around the 1.5-mm polished collar with argon shielding. Implants were fatigue tested using a step-stress accelerated lifetime test in a servo-hydraulic test machine. Despite the trend pointing towards higher fatigue resistance of laser treated specimens versus controls, step-stress analysis did not determine significant differences in the fatigue lifetimes.


Assuntos
Dente Suporte , Implantes Dentários , Retenção em Prótese Dentária/instrumentação , Análise do Estresse Dentário , Lasers , Estimativa de Kaplan-Meier , Estresse Mecânico , Titânio
16.
J Oral Sci ; 63(2): 148-151, 2021 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-33504755

RESUMO

PURPOSE: The objective of this study was to evaluate the physical and mechanical properties of a short fiber-reinforced resin composite: everX-Posterior and compare it with two bulk-fill composites, namely, Filtek Bulk-fill and Beautifil-Bulk, which are intended for large posterior restorations. METHODS: Investigated properties were flexural strength, flexural modulus, surface roughness, volumetric shrinkage and depth of cure. Scanning electron microscopy images of each specimen after the flexural test were used for cross-sectional comparison. Results were analyzed using ANOVA following Tukey post-hoc test. RESULTS: Flexural strength of everX-Posterior was comparable with two other resin composites, showing higher flexural modulus. EverX-Posterior showed the highest surface roughness after polishing and the lowest volumetric shrinkage (2.29%) among all composites used in this study. Data also showed that the everX-Posterior depth of cure was 4.24 mm, which was the highest among the three groups. CONCLUSION: Based on the results of this study, it was concluded that everX-Posterior as a short fiber-reinforced composite showed improvements and satisfactory performance in mechanical and physical properties, which make it a reliable base material candidate for large posterior restorations.


Assuntos
Resinas Compostas , Materiais Dentários , Estudos Transversais , Teste de Materiais , Propriedades de Superfície
17.
J Mech Behav Biomed Mater ; 124: 104837, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34601434

RESUMO

OBJECTIVE: Alkali treatment and bioactive glass (BG) sol dip-coating are well-known individual methods for titanium (Ti) surface modification. In this study, a unique combination of alkali treatment and bioactive glass sol dip coating was applied to the Ti substrate, then the mechanical properties and cell responses were investigated. METHODS: Based on the methods introduced above, the Ti substrate was treated by 6 mL of an NaOH 5 M aqueous solution for 24 h at 60 ̊C; this was followed by adding 1.2 mL of a BG 58S sol to form a novel combined nanostructure network covered by a thin BG layer. For the assessment of the formed coating layer, the morphology, elemental analysis, phase structure, adhesion property and the cell response of the untreated and treated surfaces were investigated. RESULTS: The BG coating layer was reinforced by the nanostructure, fabricated through the alkali treatment. The results obtained by applying the combined modification method confirmed that the mechanical and biological properties of the fabricated surface demonstrated the highest performance compared to that of the unmodified and individually modified surfaces. SIGNIFICANCE: The achieved upgrades for this method could be gained from the demanded porous nanostructure and the apatite transformation ability of the alkali treatment. Therefore, the hybridized application of the alkali-BG treatment could be introduced as a promising surface modification strategy for hard-tissue replacement applications.


Assuntos
Álcalis , Titânio , Apatitas , Vidro , Porosidade , Próteses e Implantes , Propriedades de Superfície
18.
Dent Mater J ; 40(4): 870-876, 2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-33692225

RESUMO

Yttria doped ZrO2 was deposited using an acidic zinc phosphatizing solution and the hydrothermal treatment. The coating was analyzed using a field emission-scanning electron microscope (FE-SEM), X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS). A piston on three balls (ISO 6872) was used for the measurement of biaxial flexural strength. MC3T3-E1 cells attachment was evaluated by SEM, and cell proliferation were assessed using MTS assay™. SEM images confirmed that the zinc phosphate coating layer was successfully prepared and fully covered the surface. The measured adhesive strength of the coating was 79.11 MPa. In vitro cell study indicated that the coated sample had better cell morphology and proliferation. XRD and EDS analysis revealed that the crystalline coating structure indexed as zinc phosphate (hopeite) and the substrate was assigned as zirconia. The flexural strength test showed that the strength of zirconia before and after hydrothermal treatment was not affected.


Assuntos
Zinco , Zircônio , Teste de Materiais , Propriedades de Superfície , Difração de Raios X
19.
Dent Mater J ; 40(4): 949-956, 2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-33716277

RESUMO

This study aimed to assess the mechanical and biological properties of bioactive glass (BG) coating on titanium (Ti). Bioinert Ti substrates were coated by BG to induce bioactivity to the surface. The sol-gel derived BG 58S sol was successfully prepared and coated on the abraded and blasted Ti surface using the sol-dip method. The characterization and cell study for all substrates' surface was carried out. Adhesion test confirmed that a firmly adhered BG coating layer was formed on the abraded and blasted Ti. The measured bonding strength between the coating and the blasted Ti substrate was the highest among all samples, which was 41.03±2.31 MPa. In-vitro cell viability and alkaline phosphatase activity (ALP) tests results also showed that BG coating on the Ti substrate improved the biological properties of the surface. The BG sol-dip coating method could be used to fabricate Ti substrate with a bioactive surface.


Assuntos
Materiais Revestidos Biocompatíveis , Titânio , Propriedades de Superfície
20.
J Mech Behav Biomed Mater ; 109: 103818, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32543393

RESUMO

Annealing after welding is a common operational process to improve the mechanical properties of metallic joints through releasing residual stresses in the weld zone. In this study, the effect of post weld annealing on the microstructure and mechanical properties of dissimilar laser-welds for orthodontic archwires of NiTi alloy to austenitic stainless steel has been investigated. In order to do this, the laser-welded wires were annealed at temperatures of 100, 200, and 300 °C for 1 h and then they were quenched in water. Results show that annealing at 100 °C does not affect the microstructure and mechanical properties of joints but post weld heat treatment at 200 °C ends in an increase in the tensile strength to an order of 1.91 times of the strength of as welded (non-heat-treated) joints. Also, precipitation and increase of intermetallic compounds, such as Cr2Ti, and Fe2Ti, at the weld zone during heat treatment at 300 °C, results in a reduction in the mechanical properties of joints. Therefore, post-weld annealing is an effective process on improving mechanical properties of dissimilar joints of these two alloys. However, a suitable heat-treatment temperature is needed in order to achieve desired results.


Assuntos
Fios Ortodônticos , Soldagem , Lasers , Aço Inoxidável , Aço , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA