RESUMO
BACKGROUND: Several case reports have suggested an increased risk of sudden cardiac death due to energy drinks. Therefore, the purpose of this study was to assess acute electrophysiologic effects of caffeine and taurine, two of the main ingredients of energy drinks, in an experimental whole-heart model. METHODS AND RESULTS: Twenty-five rabbit hearts were excised, retrogradely perfused, and assigned to two groups. Hearts were perfused with caffeine (2, 10, and 50 µM) or taurine (2, 10, and 50 µM) after generating baseline data. Eight monophasic action potentials and electrocardiography recordings showed a significant abbreviation of action potential duration (APD90 ), QT interval, and effective refractory periods (ERP) after caffeine treatment. With taurine, cardiac repolarization duration and ERP were significantly shortened. A ventricular vulnerability was assessed by a predefined pacing protocol. With caffeine, we observed a trend towards more ventricular arrhythmias in a dose-dependent manner. After treatment with taurine, significantly more episodes of ventricular arrhythmias occurred. CONCLUSION: In this experimental whole-heart study, treatment with caffeine and taurine provoked ventricular arrhythmias. The underlying mechanism was an abbreviation of cardiac repolarizations and effective refractory periods that may facilitate re-entry and thereby provokes arrhythmias. These findings help to understand the potentially hazardous and fatal outcomes after intoxication with energy drinks.
Assuntos
Doenças Cardiovasculares , Bebidas Energéticas , Potenciais de Ação , Animais , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/diagnóstico , Cafeína/efeitos adversos , Bebidas Energéticas/efeitos adversos , Fatores de Risco de Doenças Cardíacas , Humanos , Preparação de Coração Isolado , Coelhos , Fatores de Risco , Taurina/farmacologiaRESUMO
Background: The subcutaneous ICD (S-ICD) has developed as a valuable alternative to transvenous implantable cardioverter defibrillator (ICD) systems. However there are certain peculiarities which are immanent to the S-ICD and may limit its use. Besides oversensing the main issue is the missing option for antibradycardia pacing. To evaluate the actual need for pacing during follow-up and changes to transvenous ICD we analyzed our large tertiary centre registry and compared it with data from other large cohorts and trials. Methods and Results: We found out that in the 398 patients from our centre, there was a need for changing to a transvenous ICD in only 2 patients (0.5%) during a follow-up duration of almost 3 years. This rate was comparable to data obtained from other large data sets so that in the pooled analysis of almost 4000 patients the rate of bradycardia-associated complications was only 0.3%. Conclusions: The use of the S-ICD is safe in a variety of heart diseases and the need for antibradycardia stimulation is a very rare complication throughout many different large studies. Clinicians may take these results into account when opting for a certain ICD system and the S-ICD may be chosen more often also in elderly patients, in whom the risk for bradycardia is deemed higher.
RESUMO
Atrioventricular nodal reentry tachycardia (AVNRT) is the most common regular supraventricular tachycardia (SVT). Slow pathway modification (SPM) is the accepted first line treatment with reported success rates around 95%. Information regarding possible predictors of AVNRT recurrence is scarce.Out of 4170 consecutive patients with SPM in our department from 1993-2018, we identified 78 patients (1.9%) receiving > 1 SPM (69% female, median age 50 years) with a recurrence of AVNRT after a successful SPM. We matched these patients for age, gender and number of radiofrequency applications during first SPM with 78 patients who received one successful SPM in our center without AVNRT recurrence. Both groups were analyzed for possible predictors of a recurrence of AVNRT during long-term follow-up. The recurrence group contained a significantly lower proportion of patients with an occurrence of junctional beats during SPM (69% versus 89%, P = 0.006). Moreover, significantly more cases of previously diagnosed atrial fibrillation/tachycardia (AF/AT; 21% versus 5%, P = 0.007) and inducible AF/AT during electrophysiology study (23% versus 6%, P = 0.006) were present in the recurrence group. While more than half of patients had a recurrence within the first year, in 20% symptoms reappeared ≥ 4 years after ablation.In a small percentage of patients, AVNRT recurs after an initially successful ablation. Interestingly, these patients had significantly fewer junctional beats during ablation and a higher rate of other (inducible) arrhythmias. AVNRT recurrence spanned a considerable timeframe and should remain a differential diagnosis, even years after ablation.
Assuntos
Nó Atrioventricular/fisiopatologia , Fascículo Atrioventricular/cirurgia , Ablação por Cateter/métodos , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Adulto , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Nó Atrioventricular/cirurgia , Fascículo Atrioventricular/fisiopatologia , Eletrofisiologia Cardíaca/métodos , Eletrofisiologia Cardíaca/estatística & dados numéricos , Estudos de Casos e Controles , Diagnóstico Diferencial , Eletrocardiografia/métodos , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/classificação , Taquicardia Supraventricular/fisiopatologia , Resultado do TratamentoRESUMO
Availability of devices capable of continuous rhythm monitoring such as smartwatches, implantable loop recorders, or pacemakers/defibrillators is continuously increasing. Importantly, device detected "subclinical" atrial fibrillation seems to convey a significantly lower risk of thromboembolism than "clinical" atrial fibrillation verified by a conventional ECG recording. While current guidelines indicate a possible role of oral anticoagulation in selected high-risk patients with subclinical AF, recent trials show an ambiguous risk/benefit relationship of anticoagulation in this setting. The present review therefore summarizes current data on the role of oral anticoagulation in subclinical AF, aims at aiding in the decision process of anticoagulation, and illustrates current gaps in evidence regarding subclinical AF.
RESUMO
Atrial fibrillation (AF) is common in patients with chronic kidney disease (CKD) undergoing hemodialysis and in this patient population, management in terms of oral anticoagulation (OAC) presents unique challenges due to the increased risk of both thromboembolic events and bleeding complications. The attributable risk of AF for stroke may differ from patients without CKD, raising the question if OAC is indicated at all. Historically, vitamin K antagonists (VKA) have been the standard treatment for anticoagulation in AF; however, direct oral anticoagulants (DOACs) have emerged as an alternative therapeutic option, whereby data from prospective randomised trials with hemodialysis patients is limited resulting in great variability of practice and guideline recommendations. This review summarizes existing data sources regarding the use and benefit of oral anticoagulation with VKA and DOAC in hemodialysis patients.
RESUMO
OBJECTIVE AND BACKGROUND: Catheter-based treatment of patients with ventricular arrhythmias (VA) reduces VA and mortality in selected patients. With regard to potential risks of catheter ablation, a benefit-risk assessment should be carried out. This can be performed with risk scores such as the recently published "Risk in Ventricular Ablation (RIVA) Score". We sought to validate this score and to test for possible additional predictors in a large database of VT ablations. METHODS AND RESULTS: We analyzed 1964 catheter ablations for VA in patients with (1069; 54.4%) and without (893, 45.6%) structural heart disease (SHD) and observed an overall major adverse event rate of 4.0% with an in-hospital mortality of 1.3% with significantly less complications occurring in patients without structural heart disease (6.5% vs. 1.1%; p ≤ 0.01). The RIVA Score demonstrated to be a valid predictive tool for major in-hospital complications (OR 1.18; 95% CI 1.12, 1.25; p ≤ 0.001). NYHA Class ≥ III (OR 2.5; 95% CI 1.5, 4.2; p < 0.001) and age (OR 1.04; 95% CI 1.02, 1.07; p ≤ 0.001) proved to be additional predictive parameters. Hence, a modified RIVA Score (mRIVA) model was analyzed with a subset of established predictors (SHD, eGFR, epicardial puncture) as well as new predictive parameters (age, NYHA Class ≥ III), that achieved a higher predictive value for major complications compared with the model based on all RIVA variables. CONCLUSION: Adding age and functional heart failure status (NYHA class) as simple clinical parameters to the recently published RIVA Score increases the predictive value for ablation-associated complications in a large VT ablations registry.
Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Cardiopatias/etiologia , Fatores de Risco , Hospitais , Ablação por Cateter/métodos , Resultado do TratamentoRESUMO
BACKGROUND: Previous studies report conflicting data regarding anti- or proarrhythmic effects of sacubitril. Aim of this study was to assess the impact of acute sacubitril treatment in different arrhythmia models. METHODS: Sacubitril was administered (3, 5, 10 µM) in 12 isolated rabbit hearts. Further 12 hearts were treated with erythromycin to simulate long-QT-syndrome-2 (LQT2). Other 12 hearts were perfused with veratridine to mimic long-QT-syndrome-3 (LQT3). Both LQT-groups were treated with sacubitril (5 µM) additionally. Ventricular vulnerability was assessed by a pacing protocol. AV-blocked bradycardic hearts were perfused with a hypokalemic solution to trigger torsade de pointes (TdP). In further 13 hearts, AF was induced by a combination of acetylcholine and isoproterenol and sacubitril (5 µM) was added afterwards. RESULTS: With sacubitril, action potential duration (APD) was abbreviated whereas spatial dispersion of repolarisation (SDR) remained stable. In both LQT groups, APD and SDR were increased. Infusion of sacubitril reduced APD (- 21 ms, p < 0.01) and SDR (- 8 ms) in the LQT2-group and did not alter APD (+2 ms) but reduced SDR (-19 ms, p < 0.01) in the LQT3-group. Ventricular vulnerability was not altered by sacubitril. No TdP were observed with sacubitril or under baseline conditions in any group. Sacubitril significantly suppressed TdP in the LQT2-group (3 vs. 43 episodes, p < 0.05) but not in the LQT3-group (10 vs. 16 episodes, p = ns). Sacubitril reduced inducibility of AF (9 vs. 31 episodes). CONCLUSION: Sacubitril abbreviated APD. In addition, sacubitril exhibits potential antiarrhythmic effects in LQT2 and may be beneficial in LQT3 and AF.
Assuntos
Aminobutiratos , Compostos de BifeniloRESUMO
The implantation of cardiac devices significantly reduces morbidity and mortality in patients with cardiac arrhythmias. Arrhythmias as well as therapy delivered by the device may impact quality of life of patients concerned considerably. Therefore we aimed at conducting a systematic search and meta-analysis of trials examining the impact of the implantation of cardiac devices, namely implantable cardioverter-defibrillators (ICD), pacemakers and left-ventricular assist devices (LVAD) on quality of life. After pre-registering the trial with the PROSPERO database, we searched Medline, PsycINFO, Web of Science and the Cochrane databases for relevant publications. Study quality was assessed by two independent reviewers using standardized protocols. A total of 37 trials met our inclusion criteria. Of these, 31 trials were cohort trials while 6 trials used a randomized controlled design. We found large pre-post effect sizes for positive associations between quality of life and all types of devices. The effect sizes for LVAD, pacemaker and ICD patients were g = 1.64, g = 1.32 and g = 0.64, respectively. There was a lack of trials examining the effect of implantation on quality of life relative to control conditions. Trials assessing quality of life in patients with cardiac devices are still scarce. Yet, the existing data suggest beneficial effects of cardiac devices on quality of life. We recommend that clinical trials on cardiac devices routinely assess quality of life or other parameters of psychological well-being as a decisive study endpoint. Furthermore, improvements in psychological well-being should influence decisions about implantations of cardiac devices and be part of patient education and may impact shared decision-making.
RESUMO
Syncopes are a very common phenomenon and have a high recurrence rate. The differentiation between the psychogenic and physical, especially of arrhythmic origin, remains difficult. In many cases, an implantable loop recorder is used for the detection of possible arrhythmias, leading to syncopes. Yet, the existing literature suggests that psychological factors may play a significant role in recurrent syncopes. We aimed at analyzing the potential role of several psychological factors on the recurrence of arrhythmic or non-arrhythmic syncopes. Methods and results: A total of 119 patients, who had received an implantable loop recorder for recurrent syncopes at our center between 01/2018 and 12/2021, participated in this retrospective cohort study. Anxiety, depression and quality of life were assessed using extensively validated questionnaires (GAD-7, PHQ-9 and SF-12). The mean follow-up after loop recorder implantation was 710 ± 430 days and 50% of patients were female. The mean patient age was 54.8 ± 18.6 years. Most patients had no evidence of structural heart disease (84%), and normal LV function (92%). A statistical analysis revealed that the presence of structural heart disease was the strongest predictor for arrhythmic syncope during follow-up. In patients with non-arrhythmic syncopes, we found significantly higher levels of anxiety (GAD-7 score: 2.5 ± 2.6 vs. 4.8 ± 4.3) and depression (PHQ-9 score: 3.9 ± 3.6 vs. 6.8 ± 5.1), and a lower quality of life (SF-12 score: 33.7 ± 6.4 vs. 29.6 ± 7.8). Discussion: We identified factors as contributors to a better identification of patients at risk for arrhythmic as well as non-arrhythmic syncopes. Especially anxious or depressive symptoms may hinted at non-arrhythmic causes of syncope. However, the study was limited by its retrospective design and low patient number. Further trials should likewise combine the diagnostic yield of loop recorders with psychometric evaluations before implantation and combine it with additional diagnostic measures, such as video monitoring, to further examine the role of psychological factors in the pathomechanism and treatment of syncope.
RESUMO
Machine learning has immense novel but also disruptive potential for medicine. Numerous applications have already been suggested and evaluated concerning cardiovascular diseases. One important aspect is the detection and management of potentially thrombogenic arrhythmias such as atrial fibrillation. While atrial fibrillation is the most common arrhythmia with a lifetime risk of one in three persons and an increased risk of thromboembolic complications such as stroke, many atrial fibrillation episodes are asymptomatic and a first diagnosis is oftentimes only reached after an embolic event. Therefore, screening for atrial fibrillation represents an important part of clinical practice. Novel technologies such as machine learning have the potential to substantially improve patient care and clinical outcomes. Additionally, machine learning applications may aid cardiologists in the management of patients with already diagnosed atrial fibrillation, for example, by identifying patients at a high risk of recurrence after catheter ablation. We summarize the current state of evidence concerning machine learning and, in particular, artificial neural networks in the detection and management of atrial fibrillation and describe possible future areas of development as well as pitfalls. Typical data flow in machine learning applications for atrial fibrillation detection.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Humanos , Aprendizado de Máquina , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controleRESUMO
INTRODUCTION: Recent studies suggest cardiac involvement with an increased incidence of arrhythmias in the setting of coronavirus disease 2019 (COVID-19). The aim of this study was to evaluate the risk of potentially lethal arrhythmias and atrial fibrillation in patients with COVID-19-induced acute respiratory distress syndrome (ARDS) and to elicit possible predictors of arrhythmia occurrence. METHODS AND RESULTS: A total of 107 patients (82 male, mean age 60⯱â¯12â¯years, median body mass index 28â¯kg/m2) treated for COVID-19-induced ARDS in a large tertiary university hospital intensive care unit between March 2020 and February 2021 were retrospectively analyzed. Eighty-four patients (79%) had at least moderate ARDS, 88 patients (83%) were mechanically ventilated, 35 patients (33%) received vvECMO. Forty-three patients (40%) died during their hospital stay. Twelve patients (11%) showed potentially lethal arrhythmias (six ventricular tachycardia, six significant bradycardia). Atrial fibrillation occurred in 27 patients (25%). In a multivariate logistic regression analysis, duration of hospitalization was associated with the occurrence of potentially lethal arrhythmias (pâ¯=â¯0.006). There was no association between possible predictive factors and the occurrence of atrial fibrillation. Invasive ventilation, antipsychotics, and the QTc interval were independently associated with acute in-hospital mortality, but this was not arrhythmia-driven as there was no association between the occurrence of arrhythmias and mortality. CONCLUSION: In this relatively young population with COVID-19-induced ARDS, the incidence of potentially lethal arrhythmias was low. While overall mortality was high in these severely affected patients, cardiac involvement and arrhythmia occurrence was not a significant driver of mortality.
Assuntos
Fibrilação Atrial , COVID-19 , Síndrome do Desconforto Respiratório , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , COVID-19/complicações , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Síndrome do Desconforto Respiratório/epidemiologia , Síndrome do Desconforto Respiratório/etiologia , Estudos RetrospectivosRESUMO
Guidelines recommend transesophageal echocardiography (TEE) before cardioversion in thrombogenic arrhythmias when the requirement of ≥ 3 weeks of anticoagulation is not met. Current data to support this approach, especially with direct oral anticoagulants (DOAC), are scarce. We analyzed consecutive elective pre-cardioversion TEE in a high-volume electrophysiology center for the occurrence of left atrial appendage (LAA) thrombi or reduced LAA flow velocity. Possible predictors were recorded and compared in a multivariate logistic regression analysis. Consecutive pre-cardioversion TEE in 512 patients (148 female, median age 69 years) were included. In all patients, indication for TEE was either intake of anticoagulation < 3 weeks before cardioversion or uncertain adherence to the prescribed anticoagulation regimen. Of the 512 TEE, 19 (3.7%) depicted a LAA thrombus. An additional 41 patients (8.0%) showed either a reduced LAA flow velocity (≤ 20 cm/s), LAA sludge, or both. In a multivariate logistic regression analysis, QRS width on admission 12-lead ECG emerged as a possible predictor of LAA thrombus and reduced LAA flow (p = 0.008). Noteworthy, a high CHA2DS2-VASc score was not associated with an increased risk of reduced LAA emptying velocity and LAA thrombi were even found in patients with a CHA2DS2-VASc score of 0 (n = 1) and 1 (n = 1). The presence of LAA thrombus before an elective cardioversion is a rare event in the age of direct oral anticoagulants. However, LAA thrombi occurred even in supposed low-risk individuals according to the CHA2DS2-VASc score. QRS width may aid in identifying patients at risk of reduced LAA flow velocity.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Trombose , Idoso , Anticoagulantes/uso terapêutico , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Ecocardiografia Transesofagiana , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/etiologiaRESUMO
Background: Decision-making in primary prevention is not always trivial and many clinical scenarios are not reflected in current guidelines. To help evaluate a patient's individual risk, a new score to predict the benefit of an implantable defibrillator (ICD) for primary prevention, the MADIT-ICD benefit score, has recently been proposed. The score tries to predict occurrence of ventricular arrhythmias and non-arrhythmic death based on data from four previous MADIT trials. We aimed at examining its usefulness in a large single-center register of S-ICD patients with various underlying cardiomyopathies. Methods and results: All S-ICD patients with a primary preventive indication for ICD implantation from our large single-center database were included in the analysis (n = 173). During a follow-up of 1227 ± 978 days, 27 patients developed sustained ventricular arrhythmias, while 6 patients died for non-arrhythmic reasons. There was a significant correlation for patients with ischemic cardiomyopathy (ICM) (n = 29, p = 0.04) to the occurrence of ventricular arrhythmia. However, the occurrence of ventricular arrhythmias could not sufficiently be predicted by the MADIT-ICD VT/VF score (p = 0.3) in patients with (n = 142, p = 0.19) as well as patients without structural heart disease (n = 31, p = 0.88) and patients with LV-EF < 35%. Of the risk factors included in the risk score calculation, only non-sustained ventricular tachycardias were significantly associated with sustained ventricular arrhythmias (p = 0.02). Of note, non-arrhythmic death could effectively be predicted by the proposed non-arrhythmic mortality score as part of the benefit score (p = 0.001, r = 0.3) also mainly driven by ICM patients. Age, diabetes mellitus, and a BMI < 23 kg/m2 were key predictors of non-arrhythmic death implemented in the score. Conclusion: The MADIT-ICD benefit score adds a new option to evaluate expected benefit of ICD implantation for primary prevention. In a large S-ICD cohort of primary prevention, the value of the score was limited to patients with ischemic cardiomyopathy. Future research should evaluate the performance of the score in different subgroups and compare it to other risk scores to assess its value for daily clinical practice.
RESUMO
Introduction: Transesophageal echocardiography (TEE) is routinely performed before catheter ablation of atrial tachyarrhythmias to rule out the presence of left atrial thrombi. However, data to support this practice are inconsistent. Methods: We analyzed consecutive pre-procedural TEE in a high-volume electrophysiology center for the presence of left atrial thrombi and a relevant flow reduction in the left atrial appendage (LAA) defined as LAA sludge or LAA emptying velocity (LAAEV) < 20 cm/s. The possible predictors of reduced flow were recorded and compared in a multivariate logistic regression analysis. Results: 1676 TEE were included (1122 before pulmonary vein isolation, 436 before atrial flutter ablation, 166 before other ablations). 543 patients (32%) were female and 991 (59%) were on DOAC. Nine patients (0.5%) had an LAA thrombus on pre-procedural TEE. Ninety-five further patients (5.7%) had a relevant reduction in LAA flow. The underlying rhythm showed a significant association with the presence of LAA thrombus or reduced LAA flow (p = 0.003). Patients in sinus rhythm and cavotricuspid isthmus-dependent atrial flutter exhibited the lowest risk. Additionally, reduced kidney function was associated with a reduction in LAA flow velocities (p = 0.04). Of note, two LAA thrombi occurred in patients in sinus rhythm and six out of nine patients with an LAA thrombus were on vitamin-K antagonists. Conclusions: LAA thrombus is a rare occurrence before an elective catheter ablation. The underlying rhythm and kidney function may serve as markers of a higher likelihood of significantly reduced LAAEV and LAA thrombus.
RESUMO
INTRODUCTION: Automated echocardiography image interpretation has the potential to transform clinical practice. However, neural networks developed in general cohorts may underperform in the setting of altered cardiac anatomy. METHODS: Consecutive echocardiographic studies of patients with congenital or structural heart disease (C/SHD) were used to validate an existing convolutional neural network trained on 14,035 echocardiograms for automated view classification. In addition, a new convolutional neural network for view classification was trained and tested specifically in patients with C/SHD. RESULTS: Overall, 9793 imaging files from 262 patients with C/SHD (mean age 49 years, 60% male) and 62 normal controls (mean age 45 years, 50.0% male) were included. Congenital diagnoses included among others, tetralogy of Fallot (30), Ebstein anomaly (18) and transposition of the great arteries (TGA, 48). Assessing correct view classification based on 284,250 individual frames revealed that the non-congenital model had an overall accuracy of 48.3% for correct view classification in patients with C/SHD compared to 66.7% in patients without cardiac disease. Our newly trained convolutional network for echocardiographic view detection based on over 139,910 frames and tested on 35,614 frames from C/SHD patients achieved an accuracy of 76.1% in detecting the correct echocardiographic view. CONCLUSIONS: The current study is the first to validate view classification by neural networks in C/SHD patients. While generic models have acceptable accuracy in general cardiology patients, the quality of image classification is only modest in patients with C/SHD. In contrast, our model trained in C/SHD achieved a considerably increased accuracy in this particular cohort.
RESUMO
Previous studies suggest an impact of dexmedetomidine on cardiac electrophysiology. However, experimental data is sparse. Therefore, purpose of this study was to investigate the influence of dexmedetomidine on different experimental models of proarrhythmia. 50 rabbit hearts were explanted and retrogradely perfused. The first group (n = 12) was treated with dexmedetomidine in ascending concentrations (3, 5 and 10 µM). Dexmedetomidine did not substantially alter action potential duration (APD) but reduced spatial dispersion of repolarization (SDR) and rendered the action potentials rectangular, resulting in no proarrhythmia. In further 12 hearts, erythromycin (300 µM) was administered to simulate long-QT-syndrome-2 (LQT2). Additional treatment with dexmedetomidine reduced SDR, thereby suppressing torsade de pointes. In the third group (n = 14), 0.5 µM veratridine was added to reduce the repolarization reserve. Further administration of dexmedetomidine did not influence APD, SDR or the occurrence of arrhythmias. In the last group (n = 12), a combination of acetylcholine (1 µM) and isoproterenol (1 µM) was used to facilitate atrial fibrillation. Additional treatment with dexmedetomidine prolonged the atrial APD but did not reduce AF episodes. In this study, dexmedetomidine did not significantly alter cardiac repolarization duration and was not proarrhythmic in different models of ventricular and atrial arrhythmias. Of note, dexmedetomidine might be antiarrhythmic in acquired LQT2 by reducing SDR.
Assuntos
Arritmias Cardíacas/fisiopatologia , Dexmedetomidina/farmacologia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Animais , Modelos Animais de Doenças , Preparação de Coração Isolado , CoelhosRESUMO
INTRODUCTION: Supraventricular tachycardias (SVT) are often difficult to document due to their intermittent, short-lasting nature. Smartphone-based one-lead ECG monitors (sECG) were initially developed for the diagnosis of atrial fibrillation. No data have been published regarding their potential role in differentiating inappropiate sinus tachycardia (IST) from regular SVT. If cardiologists could distinguish IST from SVT in sECG, economic health care burden might be significantly reduced. METHODS: We prospectively recruited 75 consecutive patients with known SVT undergoing an EP study. In all patients, four ECG were recorded: a sECG during SVT and during sinus tachycardia and respective 12-lead ECG. Two experienced electrophysiologists were blinded to the diagnoses and separately evaluated all ECG. RESULTS: Three hundred individual ECG were recorded in 75 patients (47 female, age 50 ± 18 years, BMI 26 ± 5 kg/m2, 60 AVNRT, 15 AVRT). The electrophysiologists' blinded interpretation of sECG recordings showed a sensitivity of 89% and a specificity of 91% for the detection of SVT (interobserver agreement κ = 0.76). In high-quality sECG recordings (68%), sensitivity rose to 95% with a specificity of 92% (interobserver agreement of κ = 0.91). Specificity increased to 96% when both electrophysiologists agreed on the diagnosis. Respective 12-lead ECG had a sensitivity of 100% and specificity of 98% for the detection of SVT. CONCLUSION: A smartphone-based one-lead ECG monitor allows for differentiation of SVT from IST in about 90% of cases. These results should encourage cardiologists to integrate wearables into clinical practice, possibly reducing time to definitive diagnosis of an arrhythmia and unnecessary EP procedures. A smartphone-based one lead ECG device (panel A) can be used reliably to differentiate supraventricular tachycardia (panel B) from inappropriate sinus tachycardia when compared to a simultaneously conducted gold-standard electrophysiology study (panels C, D).
Assuntos
Eletrocardiografia/métodos , Smartphone , Taquicardia Supraventricular/diagnóstico , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/fisiopatologia , Taquicardia Supraventricular/fisiopatologiaRESUMO
INTRODUCTION: The AliveCor Kardia ECG monitor (ACK) offers a smartphone-based one-lead ECG recording for the detection of atrial fibrillation. We compared ACK lead I recordings with the 12-lead ECG and introduce a novel parasternal lead (NPL). METHODS: Consecutive cardiac inpatients were recruited. In all patients a 12-lead ECG, ACK lead I and NPL were obtained. Two experienced electrophysiologists were blinded and separately evaluated all ECG. We calculated sensitivity, specificity, and predictive values of the ACK ECG compared to the 12-lead ECG. RESULTS: 296 ECG from 99 patients (38 female, age 64 ± 15 years, BMI 27.8 ± 5.1 kg/m2) were analyzed. 20% of ACK lead I recordings contained a critical amount of artifact. The electrophysiologists' interpretation of the ACK recordings yielded a sensitivity of 100% and specificity of 94% for atrial fibrillation or flutter in lead I (κ = 0.90) and a sensitivity of 96% and specificity of 97% in the NPL (κ = 0.92). The ACK diagnostic algorithm displayed a significantly lower sensitivity (55-70%), specificity (60-69%), and accuracy (κ = 0.4-0.53) but a high negative predictive value (100%). Patients with atrial flutter (n = 5) and with ventricular stimulation (n = 12) had a high likelihood of being misclassified by the algorithm. CONCLUSION: The AliveCor Kardia ECG monitor allows a highly accurate detection of atrial fibrillation by an interpreting electrophysiologist both in the standard lead I and a novel parasternal lead. The diagnostic algorithm offered by the system may be useful in screening recordings for further review. Diagnostic challenges present in atrial flutter and ventricular pacemaker stimulation.
Assuntos
Fibrilação Atrial , Aplicativos Móveis , Idoso , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , SmartphoneRESUMO
There is conflicting evidence regarding the impact of propofol on cardiac repolarization and the risk of torsade de pointes (TdP). The purpose of this study was to elucidate the risk of propofol-induced TdP and to investigate the impact of propofol in drug-induced long QT syndrome. 35 rabbit hearts were perfused employing a Langendorff-setup. 10 hearts were perfused with increasing concentrations of propofol (50, 75, 100 µM). Propofol abbreviated action potential duration (APD90) in a concentration-dependent manner without altering spatial dispersion of repolarization (SDR). Consequently, no proarrhythmic effects of propofol were observed. In 12 further hearts, erythromycin was employed to induce prolongation of cardiac repolarization. Erythromycin led to an amplification of SDR and triggered 36 episodes of TdP. Additional infusion of propofol abbreviated repolarization and reduced SDR. No episodes of TdP were observed with propofol. Similarly, ondansetron prolonged cardiac repolarization in another 13 hearts. SDR was increased and 36 episodes of TdP occurred. With additional propofol infusion, repolarization was abbreviated, SDR reduced and triggered activity abolished. In this experimental whole-heart study, propofol abbreviated repolarization without triggering TdP. On the contrary, propofol reversed prolongation of repolarization caused by erythromycin or ondansetron, reduced SDR and thereby eliminated drug-induced TdP.