Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Appl Spectrosc ; 57(8): 1020-6, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-14661846

RESUMO

Using a spectrograph and charge-coupled device (CCD) camera, ultraviolet and visible light emission spectra were obtained from a coal-burning electric utility's cyclone furnaces operating at either fuel-rich or fuel-lean conditions. The aim of this effort is to identify light emission signals that can be related to a cyclone furnace's operating condition in order to adjust its air/fuel ratio to minimize pollutant production. Emission spectra at the burner and outlet ends of cyclone furnaces were obtained. Spectra from all cyclone burners show emission lines for the trace elements Li, Na, K, and Rb, as well as the molecular species OH and CaOH. The Ca emission line is detected at the burner end of both the fuel-rich and fuel-lean cyclone furnaces but is not detected at the outlet ends of either furnace type. Along with the disappearance of Ca is a concomitant increase in the CaOH signal at the outlet end of both types of furnaces. The OH signal strength is in general stronger when viewing at the burner end rather than the exhaust end of both the fuel-rich and fuel-lean cyclone furnaces, probably due to high, non-equilibrium amounts of OH present inside the furnace. Only one molecular species was detected that could be used as a measure of air/fuel ratio: MgOH. It was detected at the burner end of fuel-rich cyclone furnaces but not detected in fuel-lean cyclone furnaces. More direct markers of air/fuel ratio, such as CO and O2 emission, were not detected, probably due to the generally weak nature of molecular emission relative to ambient blackbody emission present in the cyclone furnaces, even at ultraviolet wavelengths.


Assuntos
Poluição do Ar/análise , Carvão Mineral , Análise Espectral/métodos , Poluição do Ar/prevenção & controle , Hidróxido de Cálcio/análise , Luz , Centrais Elétricas , Análise Espectral/instrumentação , Oligoelementos/análise
2.
Appl Opt ; 44(31): 6616-26, 2005 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-16270550

RESUMO

The previously demonstrated nonintrusive time-of-flight molecular velocity tagging method, hydroxyl tagging velocimetry (HTV), has shown the capability of operating both at room temperature and in flames. Well-characterized jets of either air (nonreacting cases) or hydrogen-air diffusion flames (reacting cases) are employed. A 7 x 7 OH line grid is generated first through the single-photon photodissociation of H2O by a approximately 193 nm pulsed narrowband ArF excimer laser and is subsequently revealed by a read laser sheet through fluorescence caused by A2sigma+(v' = 3) <-- X2pi(i)(v'' = 0), A2sigma+(v' = 1) <-- X2pi(i)(v'' = 0), or A2sigma+(v' = 0) < or = X2pi(i)(v'' = 0) pumping at approximately 248, approximately 282, or approximately 308 nm, respectively. A detailed discussion of the spectroscopy and relative signal intensity of these various read techniques is presented, and the implications for optimal HTV performance are discussed.

3.
Appl Opt ; 44(31): 6692-700, 2005 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-16270558

RESUMO

Hydroxyl tagging velocimetry (HTV) measurements of velocity were made in a Mach 2 (M 2) flow with a wall cavity. In the HTV method, ArF excimer laser (193 nm) beams pass through a humid gas and dissociate H2O into H + OH to form a tagging grid of OH molecules. In this study, a 7 x 7 grid of hydroxyl (OH) molecules is tracked by planar laser-induced fluorescence. The grid motion over a fixed time delay yields about 50 velocity vectors of the two-dimensional flow in the plane of the laser sheets. Velocity precision is limited by the error in finding the crossing location of the OH lines written by the excimer tag laser. With a signal-to-noise ratio of about 10 for the OH lines, the determination of the crossing location is expected to be accurate within +/- 0.1 pixels. Velocity precision within the freestream, where the turbulence is low, is consistent with this error. Instantaneous, single-shot measurements of two-dimensional flow patterns were made in the nonreacting M 2 flow with a wall cavity under low- and high-pressure conditions. The single-shot profiles were analyzed to yield mean and rms velocity profiles in the M 2 nonreacting flow.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA