Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Vasc Interv Radiol ; 35(3): 362-369, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38123126

RESUMO

PURPOSE: To determine time to occlusion and procedure costs of embolization of pulmonary arteriovenous malformations (PAVMs) using a polytetrafluoroethylene-covered microplug compared with embolization using detachable coils. MATERIALS AND METHODS: In this prospective study, 37 patients (mean age, 39.1 years [SD ± 17.6]) with 82 PAVMs underwent embolization with microplug or detachable coils between April 2019 and January 2023. Technical success, procedure time intervals, and costs were analyzed. RESULTS: In 37 patients, 82 PAVMs and 101 feeding arteries were successfully treated (microplug, 64; microplug + another device, 5; detachable coils alone, 32). Time from embolic device inserted into the catheter to device deployed and time to occlusion differed significantly between microplug and detachable coil cohorts (P < .0001 for both). Embolization with ≥1 microplug had a significantly shorter occlusion time than embolization with detachable coils (median, 10.0 minutes saved per feeding artery) (P < .0001). Compared with detachable coil embolization, microplug embolization saved a median of 9.0 minutes per feeding artery (P < .0001) and reduced room cost by a median of $429 per feeding artery (P < .0001). Device costs per feeding artery did not differ significantly between microplug ($2,790) and detachable coil embolization ($3,147) (P = .87). CONCLUSIONS: Compared with coils, microplugs had an equally high technical success rate but significant time to occlusion and room costs savings per feeding artery. Total room cost and device cost together did not differ significantly between microplugs and coils. Microplugs may be considered technically effective and at least cost-neutral for PAVM embolization where clinically appropriate.


Assuntos
Fístula Arteriovenosa , Malformações Arteriovenosas , Embolização Terapêutica , Artéria Pulmonar/anormalidades , Veias Pulmonares , Veias Pulmonares/anormalidades , Humanos , Adulto , Estudos Prospectivos , Politetrafluoretileno , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/terapia , Fístula Arteriovenosa/terapia , Embolização Terapêutica/métodos , Artéria Pulmonar/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Resultado do Tratamento
2.
J Am Coll Radiol ; 21(5): 729-739, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38191081

RESUMO

INTRODUCTION: Black and underinsured women in the United States are more likely than their counterparts to develop uterine fibroids (UFs) and experience more severe symptoms. Uterine artery embolization (UAE), a uterine-sparing therapeutic procedure, is less invasive than the common alternative, open hysterectomy. To determine whether demographic disparities persist in UF treatment utilization, we reviewed patient characteristics associated with UAE versus hysterectomy for UF among studies of US clinical practices. METHODS: A systematic literature review was conducted via PubMed, Embase, and CINAHL (PROSPERO CRD42023455051), yielding 1,350 articles (January 1, 1995, to July 15, 2023) that outlined demographic characteristics of UAE compared with hysterectomy. Two readers screened for inclusion criteria, yielding 13 full-text US-based comparative studies specifying at least one common demographic characteristic. Random effects meta-analysis was performed on the data (STATA v18.0). Egger's regression test was used to quantify publication bias. RESULTS: Nine (138,960 patients), four (183,643 patients), and seven (312,270 patients) studies were analyzed for race, insurance status, and age as predictors of treatment modality, respectively. Black race (odds ratio = 3.35, P < .01) and young age (P < .05) were associated with UAE, whereas private insurance (relative to Medicare and/or Medicaid) was not (odds ratio = 1.06, P = .52). Between-study heterogeneity (I2 > 50%) was detected in all three meta-analyses. Small-study bias was detected for age but not race or insurance. CONCLUSIONS AND IMPLICATIONS: Knowledge of demographic characteristics of patients with UFs receiving UAE versus hysterectomy is sparse (n = 13 studies). Among these studies, which seem to be racially well distributed, Black and younger women are more likely to receive UAE than their counterparts.


Assuntos
Histerectomia , Leiomioma , Embolização da Artéria Uterina , Neoplasias Uterinas , Feminino , Leiomioma/terapia , Leiomioma/cirurgia , Humanos , Neoplasias Uterinas/terapia , Neoplasias Uterinas/cirurgia , Estados Unidos
3.
J Am Coll Radiol ; 21(5): 740-751, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38220040

RESUMO

INTRODUCTION: Transarterial radioembolization (TARE) is one of the most promising therapeutic options for hepatic masses. Radiomics features, which are quantitative numeric features extracted from medical images, are considered to have potential in predicting treatment response in TARE. This article aims to provide meta-analytic evidence and critically appraise the methodology of radiomics studies published in this regard. METHODS: A systematic search was performed on PubMed, Scopus, Embase, and Web of Science. All relevant articles were retrieved, and the characteristics of the studies were extracted. The Radiomics Quality Score and Checklist for Evaluation of Radiomics Research were used to assess the methodologic quality of the studies. Pooled sensitivity, specificity, and area under the receiver operating characteristic curve in predicting objective response were determined. RESULTS: The systematic review included 15 studies. The average Radiomics Quality Score of these studies was 11.4 ± 2.1, and the average Checklist for Evaluation of Radiomics Research score was 33± 6.7. There was a notable correlation (correlation coefficient = 0.73) between the two metrics. Adherence to quality measures differed considerably among the studies and even within different components of the same studies. The pooled sensitivity and specificity of the radiomics models in predicting complete or partial response were 83.5% (95% confidence interval 76%-88.9%) and 86.7% (95% confidence interval 78%-92%), respectively. CONCLUSION: Radiomics models show great potential in predicting treatment response in TARE of hepatic lesions. However, the heterogeneity seen between the methodologic quality of studies may limit the generalizability of the results. Future initiatives should aim to develop radiomics signatures using multiple external datasets and adhere to quality measures in radiomics methodology.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Embolização Terapêutica/métodos , Resultado do Tratamento , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Valor Preditivo dos Testes , Radiômica
4.
Artigo em Inglês | MEDLINE | ID: mdl-38516341

RESUMO

Among the numerous additive manufacturing or "three-dimensional (3D) printing" techniques, two-photon Direct Laser Writing (DLW) is distinctively suited for applications that demand high geometric versatility with micron-to-submicron-scale feature resolutions. Recently, "ex situ DLW (esDLW)" has emerged as a powerful approach for printing 3D microfluidic structures directly atop meso/macroscale fluidic tubing that can be manipulated by hand; however, difficulties in creating custom esDLW-compatible multilumen tubing at such scales has hindered progress. To address this impediment, here we introduce a novel methodology for fabricating submillimeter multilumen tubing for esDLW 3D printing. Preliminary fabrication results demonstrate the utility of the presented strategy for resolving 743 µm-in-diameter tubing with three lumens-each with an inner diameter (ID) of 80 µm. Experimental results not only revealed independent flow of discrete fluorescently labelled fluids through each of the three lumens, but also effective esDLW-printing of a demonstrative 3D "MEMS" microstructure atop the tubing. These results suggest that the presented approach could offer a promising pathway to enable geometrically sophisticated microfluidic systems to be 3D printed with input and/or output ports fully sealed to multiple, distinct lumens of fluidic tubing for emerging applications in fields ranging from drug delivery and medical diagnostics to soft surgical robotics.

5.
J Neurointerv Surg ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637150

RESUMO

Advancements in technology and technical expertise increasingly enable neurointerventionalists to deliver safer and more effective endovascular treatments to cancers of the brain, spine, head, and neck. In addition to established neuro-oncological interventions such as pre-surgical tumor embolization and percutaneous ablation, newer modalities focused on direct arterial infusion of chemotherapy, radioisotopes, and radiosensitizers continue to gain traction as complementary treatment options, while stem cell-mediated delivery of theranostic nanoparticles and oncolytic virus are being explored for even greater specificity in targeting cancers across the blood-brain barrier. This article aims to provide an overview of the current state of the art and future directions for the field of interventional neuro-oncology, as well as opportunities and challenges presented by this emerging treatment modality.

6.
Med Phys ; 51(6): 4158-4180, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38733602

RESUMO

PURPOSE: Interventional Cone-Beam CT (CBCT) offers 3D visualization of soft-tissue and vascular anatomy, enabling 3D guidance of abdominal interventions. However, its long acquisition time makes CBCT susceptible to patient motion. Image-based autofocus offers a suitable platform for compensation of deformable motion in CBCT, but it relies on handcrafted motion metrics based on first-order image properties and that lack awareness of the underlying anatomy. This work proposes a data-driven approach to motion quantification via a learned, context-aware, deformable metric, VI F D L ${\bm{VI}}{{\bm{F}}}_{DL}$ , that quantifies the amount of motion degradation as well as the realism of the structural anatomical content in the image. METHODS: The proposed VI F D L ${\bm{VI}}{{\bm{F}}}_{DL}$ was modeled as a deep convolutional neural network (CNN) trained to recreate a reference-based structural similarity metric-visual information fidelity (VIF). The deep CNN acted on motion-corrupted images, providing an estimation of the spatial VIF map that would be obtained against a motion-free reference, capturing motion distortion, and anatomic plausibility. The deep CNN featured a multi-branch architecture with a high-resolution branch for estimation of voxel-wise VIF on a small volume of interest. A second contextual, low-resolution branch provided features associated to anatomical context for disentanglement of motion effects and anatomical appearance. The deep CNN was trained on paired motion-free and motion-corrupted data obtained with a high-fidelity forward projection model for a protocol involving 120 kV and 9.90 mGy. The performance of VI F D L ${\bm{VI}}{{\bm{F}}}_{DL}$ was evaluated via metrics of correlation with ground truth VIF ${\bm{VIF}}$ and with the underlying deformable motion field in simulated data with deformable motion fields with amplitude ranging from 5 to 20 mm and frequency from 2.4 up to 4 cycles/scan. Robustness to variation in tissue contrast and noise levels was assessed in simulation studies with varying beam energy (90-120 kV) and dose (1.19-39.59 mGy). Further validation was obtained on experimental studies with a deformable phantom. Final validation was obtained via integration of VI F D L ${\bm{VI}}{{\bm{F}}}_{DL}$ on an autofocus compensation framework, applied to motion compensation on experimental datasets and evaluated via metric of spatial resolution on soft-tissue boundaries and sharpness of contrast-enhanced vascularity. RESULTS: The magnitude and spatial map of VI F D L ${\bm{VI}}{{\bm{F}}}_{DL}$ showed consistent and high correlation levels with the ground truth in both simulation and real data, yielding average normalized cross correlation (NCC) values of 0.95 and 0.88, respectively. Similarly, VI F D L ${\bm{VI}}{{\bm{F}}}_{DL}$ achieved good correlation values with the underlying motion field, with average NCC of 0.90. In experimental phantom studies, VI F D L ${\bm{VI}}{{\bm{F}}}_{DL}$ properly reflects the change in motion amplitudes and frequencies: voxel-wise averaging of the local VI F D L ${\bm{VI}}{{\bm{F}}}_{DL}$ across the full reconstructed volume yielded an average value of 0.69 for the case with mild motion (2 mm, 12 cycles/scan) and 0.29 for the case with severe motion (12 mm, 6 cycles/scan). Autofocus motion compensation using VI F D L ${\bm{VI}}{{\bm{F}}}_{DL}$ resulted in noticeable mitigation of motion artifacts and improved spatial resolution of soft tissue and high-contrast structures, resulting in reduction of edge spread function width of 8.78% and 9.20%, respectively. Motion compensation also increased the conspicuity of contrast-enhanced vascularity, reflected in an increase of 9.64% in vessel sharpness. CONCLUSION: The proposed VI F D L ${\bm{VI}}{{\bm{F}}}_{DL}$ , featuring a novel context-aware architecture, demonstrated its capacity as a reference-free surrogate of structural similarity to quantify motion-induced degradation of image quality and anatomical plausibility of image content. The validation studies showed robust performance across motion patterns, x-ray techniques, and anatomical instances. The proposed anatomy- and context-aware metric poses a powerful alternative to conventional motion estimation metrics, and a step forward for application of deep autofocus motion compensation for guidance in clinical interventional procedures.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Movimento , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Humanos
7.
Med Image Anal ; 97: 103254, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38968908

RESUMO

The present standard of care for unresectable liver cancer is transarterial chemoembolization (TACE), which involves using chemotherapeutic particles to selectively embolize the arteries supplying hepatic tumors. Accurate volumetric identification of intricate fine vascularity is crucial for selective embolization. Three-dimensional imaging, particularly cone-beam CT (CBCT), aids in visualization and targeting of small vessels in such highly variable anatomy, but long image acquisition time results in intra-scan patient motion, which distorts vascular structures and tissue boundaries. To improve clarity of vascular anatomy and intra-procedural utility, this work proposes a targeted motion estimation and compensation framework that removes the need for any prior information or external tracking and for user interaction. Motion estimation is performed in two stages: (i) a target identification stage that segments arteries and catheters in the projection domain using a multi-view convolutional neural network to construct a coarse 3D vascular mask; and (ii) a targeted motion estimation stage that iteratively solves for the time-varying motion field via optimization of a vessel-enhancing objective function computed over the target vascular mask. The vessel-enhancing objective is derived through eigenvalues of the local image Hessian to emphasize bright tubular structures. Motion compensation is achieved via spatial transformer operators that apply time-dependent deformations to partial angle reconstructions, allowing efficient minimization via gradient backpropagation. The framework was trained and evaluated in anatomically realistic simulated motion-corrupted CBCTs mimicking TACE of hepatic tumors, at intermediate (3.0 mm) and large (6.0 mm) motion magnitudes. Motion compensation substantially improved median vascular DICE score (from 0.30 to 0.59 for large motion), image SSIM (from 0.77 to 0.93 for large motion), and vessel sharpness (0.189 mm-1 to 0.233 mm-1 for large motion) in simulated cases. Motion compensation also demonstrated increased vessel sharpness (0.188 mm-1 before to 0.205 mm-1 after) and reconstructed vessel length (median increased from 37.37 to 41.00 mm) on a clinical interventional CBCT. The proposed anatomy-aware motion compensation framework presented a promising approach for improving the utility of CBCT for intra-procedural vascular imaging, facilitating selective embolization procedures.

8.
Eur J Radiol ; 174: 111397, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38452733

RESUMO

PURPOSE: To investigate quantitative changes in MRI signal intensity (SI) and lesion volume that indicate treatment response and correlate these changes with clinical outcomes after percutaneous sclerotherapy (PS) of extremity venous malformations (VMs). METHODS: VMs were segmented manually on pre- and post-treatment T2-weighted MRI using 3D Slicer to assess changes in lesion volume and SI. Clinical outcomes were scored on a 7-point Likert scale according to patient perception of symptom improvement; treatment response (success or failure) was determined accordingly. RESULTS: Eighty-one patients with VMs underwent 125 PS sessions. Treatment success occurred in 77 patients (95 %). Mean (±SD) changes were -7.9 ± 24 cm3 in lesion volume and -123 ± 162 in SI (both, P <.001). Mean reduction in lesion volume was greater in the success group (-9.4 ± 24 cm3) than in the failure group (21 ± 20 cm3) (P =.006). Overall, lesion volume correlated with treatment response (ρ = -0.3, P =.004). On subgroup analysis, volume change correlated with clinical outcomes in children (ρ = -0.3, P =.03), in sodium tetradecyl sulfate-treated lesions (ρ = -0.5, P =.02), and in foot lesions (ρ = -0.6, P =.04). SI change correlated with clinical outcomes in VMs treated in 1 PS session (ρ = -0.3, P =.01) and in bleomycin-treated lesions (ρ = -0.4, P =.04). CONCLUSIONS: Change in lesion volume is a reliable indicator of treatment response. Lesion volume and SI correlate with clinical outcomes in specific subgroups.


Assuntos
Escleroterapia , Malformações Vasculares , Criança , Humanos , Soluções Esclerosantes/uso terapêutico , Estudos Retrospectivos , Malformações Vasculares/diagnóstico por imagem , Malformações Vasculares/terapia , Veias , Resultado do Tratamento
9.
Abdom Radiol (NY) ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38951233

RESUMO

PURPOSE: To describe residual arterial supply to the stomach after bariatric surgery via a systematic arterial-phase CT assessment approach that can aid in diagnosis and treatment of postoperative complications and facilitate planning for future procedures. METHODS: Arterial-phase CT of 46 patients who underwent Roux-en-Y gastric bypass (RYGB) or sleeve gastrectomy (SG) at 3 academic institutions were retrospectively reviewed to assess patency of left gastric artery (LGA), right gastric artery (RGA), gastroepiploic artery (GEA), and left inferior phrenic artery (LIPA) and presence of gastric perforators. RESULTS: In 25 RYGB and 21 SG patients, mean diameters were LGA 2.2 ± 0.4 mm, RGA 1.6 ± 0.5 mm, and GEA 1.7 ± 0.4 mm. On RYGB scans, all LGAs, RGAs, and 24/25 (96%) of GEAs were identified. Excellent to good patency was seen in 20/25 (80%) LGAs, 21/25 (84%) RGAs, and 23/24 (96%) GEAs. On SG scans, all LGAs, 18/21 (86%) of RGAs, and 20/21 (95%) GEAs were identified. Excellent to good patency was seen in 17/21 (81%) LGAs, 15/18 (83%) RGAs, and 20/20 (100%) GEAs. In terms of gastric perforators, LGA supply was seen on 23/25 (92%) of RYGB and 17/17 (100%) of SG scans. RGA supply was seen on 13/21 (62%) RYGB and 9/18 (50%) SG scans. GEA supply was seen on 19/23 (83%) RYGB scans. No gastric supply via GEA was seen on SG scans. CONCLUSION: In this study, arterial supply to the stomach through the LGA was consistently identified in all RYGB and SG cases, indicating an uncomplicated surgical approach with regard to preserving the LGA. Dedicated CT angiography protocol or catheter-directed angiography is recommended for accurate and comprehensive assessment of the gastric blood supply, particularly before surgical re-intervention.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA