Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur Radiol ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780766

RESUMO

OBJECTIVES: To establish and evaluate an ultra-fast MRI screening protocol for prostate cancer (PCa) in comparison to the standard multiparametric (mp) protocol, reducing scan time and maintaining adequate diagnostic performance. MATERIALS AND METHODS: This prospective single-center study included consecutive biopsy-naïve patients with suspected PCa between December 2022 and March 2023. A PI-RADSv2.1 conform mpMRI protocol was acquired in a 3 T scanner (scan time: 25 min 45 sec). In addition, two deep-learning (DL) accelerated sequences (T2- and diffusion-weighted) were acquired, serving as a screening protocol (scan time: 3 min 28 sec). Two readers evaluated image quality and the probability of PCa regarding PI-RADSv2.1 scores in two sessions. The diagnostic performance of the screening protocol with mpMRI serving as the reference standard was derived. Inter- and intra-reader agreements were evaluated using weighted kappa statistics. RESULTS: We included 77 patients with 97 lesions (mean age: 66 years; SD: 7.7). Diagnostic performance of the screening protocol was excellent with a sensitivity and specificity of 100%/100% and 89%/98% (cut-off ≥ PI-RADS 4) for reader 1 (R1) and reader 2 (R2), respectively. Mean image quality was 3.96 (R1) and 4.35 (R2) for the standard protocol vs. 4.74 and 4.57 for the screening protocol (p < 0.05). Inter-reader agreement was moderate (κ: 0.55) for the screening protocol and substantial (κ: 0.61) for the multiparametric protocol. CONCLUSION: The ultra-fast screening protocol showed similar diagnostic performance and better imaging quality compared to the mpMRI in under 15% of scan time, improving efficacy and enabling the implementation of screening protocols in clinical routine. CLINICAL RELEVANCE STATEMENT: The ultra-fast protocol enables examinations without contrast administration, drastically reducing scan time to 3.5 min with similar diagnostic performance and better imaging quality. This facilitates patient-friendly, efficient examinations and addresses the conflict of increasing demand for examinations at currently exhausted capacities. KEY POINTS: Time-consuming MRI protocols are in conflict with an expected increase in examinations required for prostate cancer screening. An ultra-fast MRI protocol shows similar performance and better image quality compared to the standard protocol. Deep-learning acceleration facilitates efficient and patient-friendly examinations, thus improving prostate cancer screening capacity.

2.
Pacing Clin Electrophysiol ; 47(3): 347-352, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38140909

RESUMO

BACKGROUND: Cryoballoon ablation for atrial fibrillation (AF) requires adequate contact between the pulmonary vein (PV) antrum and cryoballoon. The surge of intraballoon pressure during the initial phase of ablation may change the balloon's shape and compliance, resulting in balloon dislodgement and loss of PV occlusion. Without continuous monitoring, this phenomenon is often undetected but can be associated with incomplete PV isolation (PVI). METHODS: Primary cryoablation of AF was performed in 15 patients. PV occlusion status pre- and post-freezing were analyzed with intracardiac echocardiography (ICE) and dielectric imaging-based occlusion tool (DIOT) to calculate the incidence of expansion dislodgement of cryoballoon. RESULTS: A total of 105 cryoablation applications were performed on 57 veins, including three common ostiums of left pulmonary veins. In the evaluation of PV occlusion, both modalities reported consistent results in 86.7% of the assessments. Despite complete PV occlusion before ablation, peri-balloon leak after initiation of freezing was detected by ICE in 5/22 (22.7%) applications and by DIOT in 8/25 (32%) applications. CONCLUSION: Incidence of expansion dislodgement of the cryoballoon was detected in one-fourth to one-third of cryoablation applications depending on the imaging modality used, which was clinically frequent and significant.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Incidência , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Resultado do Tratamento , Ablação por Cateter/métodos
3.
Support Care Cancer ; 32(8): 500, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985388

RESUMO

PURPOSE: Within families affected by parental cancer, open communication impacts the well-being of parents and their children; however, limited research exists on communication patterns in these families. This sub-study addresses this through the Family-SCOUT study, a multicenter, prospective, interventional, and non-randomized investigation with intervention (IG) and control group (CG). The purpose of this sub-study was to identify and compare the differences in communication patterns between the IG and CG as part of the process evaluation. The research question was addressed in both groups: What communication patterns do healthy parents perceive within their families? METHODS: Using a qualitative approach, the study involved interviewing healthy parents as surrogates for their families. The interviews were audio-recorded, transcribed, and coded using a template analysis. The resulting data were analyzed at the group level. RESULTS: Twenty-three interviews were conducted in the IG and 27 interviews in the CG. The analysis of themes centered on communication patterns as seen in the family structure. Both groups exhibited instances of open communication about fears and wishes as well as the use of child-friendly language when discussing cancer. Notable differences were observed: challenges in open communication with children were sorely reported in CG interviews, and "the illness is discussed when necessary" was sorely described in IG interviews. CONCLUSION: This study underscores the need to address and encourage open communication within families with parental cancer.


Assuntos
Comunicação , Neoplasias , Pais , Humanos , Neoplasias/psicologia , Feminino , Masculino , Pais/psicologia , Adulto , Estudos Prospectivos , Criança , Pessoa de Meia-Idade , Pesquisa Qualitativa , Entrevistas como Assunto , Filho de Pais com Deficiência/psicologia
4.
Radiol Cardiothorac Imaging ; 6(3): e230303, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38869431

RESUMO

Purpose To examine the clinical effect of lead length and lead orientation in patients with cardiac implantable electronic devices (CIEDs) and lead fragments or abandoned leads undergoing 1.5-T MRI. Materials and Methods This Health Insurance Portability and Accountability Act-compliant retrospective study included patients with CIEDs and abandoned leads or lead fragments undergoing 1.5-T MRI from March 2014 through July 2020. CIED settings before and after MRI were reviewed, with clinically significant variations defined as a composite of the change in capture threshold of at least 50%, in sensing of at least 40%, or in lead impedance of at least 30% between before MRI and after MRI interrogation. Adverse clinical events were assessed at MRI and up to 30 days after. Univariable and multivariable analysis was performed. Results Eighty patients with 126 abandoned CIED leads or lead fragments underwent 107 1.5-T MRI examinations. Sixty-seven patients (median age, 74 years; IQR, 66-78 years; 44 male patients, 23 female patients) had abandoned leads, and 13 (median age, 66 years; IQR, 52-74 years; nine male patients, four female patients) had lead fragments. There were no reported deaths, clinically significant arrhythmias, or adverse clinical events within 30 days of MRI. Three patients with abandoned leads had a significant change in the composite of capture threshold, sensing, or lead impedance. In a multivariable generalized estimating equation analysis, lead orientation, lead length, MRI type, and MRI duration were not associated with a significant change in the composite outcome. Conclusion Use of 1.5-T MRI in patients with abandoned CIED leads or lead fragments of varying length and orientation was not associated with adverse clinical events. Keywords: Cardiac Assist Devices, MRI, Cardiac Implantable Electronic Device Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Marca-Passo Artificial/efeitos adversos , Pessoa de Meia-Idade , Falha de Equipamento/estatística & dados numéricos
5.
HeartRhythm Case Rep ; 10(5): 310-311, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38799599
9.
Clin Infect Dis ; 28(5): 1086-90, May 1999.
Artigo em Inglês | MedCarib | ID: med-1381

RESUMO

Individuals presenting consecutively with genital ulcers in Kingston, Jamaica, underwent serological testing for human immunodeficiency virus (HIV) infection , chlamydial infection, and syphilis. Ulcer material was analyzed by the multiplex polymerase chain reaction (M-PCR) analysis DNA from herpes simplex virus (HSV), Haemophilus ducreyi, and Treponema pallidum was detected in 158 (52.0 percent), 72 (23.7 percent), and 31 (10.2 percent) of 304 ulcer specimens. Of the 304 subjects, 67 (22 percent) were HIV-seropositive and 64 (21 percent) were T. pallidum-seroactive. Granuloma inguinale was clinically diagnosed in nine (13.4 percent) of 67 ulcers negative by M-PCR analysis and in 12 (5.1 percent) of 237 ulcers positive by M-PCR analysis (P = .03). Lymphogranuloma venereum was clinically diagnosed in eight patients. Compared with M-PCR analysis, the sensitivity and specificity of a clinical diagnosis of syphilis, herpes, and chancroid were 67.7 percent, 53.8 percent, and 75 percent and 91.2 percent, 83.6 percent, and 75.4 percent, respectively. Reactive syphilis serology was 74 percent sensitive and 85 percent specific compared with M-PCR analysis. Reported contact with a prostitute in the preceding 3 months was associated with chancroid (P = .009), reactive syphilis serology (P = .011), and HIV infection (P = .007). The relatively poor pleads for syndromic management of genital ulcers in Jamaica. Prevention efforts should be intensified.(Au)


Assuntos
Adulto , Feminino , Masculino , Humanos , Doenças dos Genitais Femininos/microbiologia , Doenças dos Genitais Masculinos/microbiologia , Infecções por HIV/complicações , Úlcera/microbiologia , HIV-1 , HIV-2 , Jamaica , Linfogranuloma Venéreo/complicações , Linfogranuloma Venéreo/diagnóstico , Reação em Cadeia da Polimerase , Prevalência , Fatores de Risco , Sensibilidade e Especificidade , Simplexvirus/isolamento & purificação , Treponema pallidum/isolamento & purificação , Úlcera/complicações , Doenças dos Genitais Femininos/complicações , Doenças dos Genitais Femininos/diagnóstico , Doenças dos Genitais Masculinos/complicações , Doenças dos Genitais Masculinos/diagnóstico , Haemophilus ducreyi/isolamento & purificação , Herpes Genital/complicações , Herpes Genital/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA