J Neurooncol ; 101(2): 267-77, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20563833

RESUMO

The PRECISE study used convection enhanced delivery (CED) to infuse IL13-PE38QQR in patients with recurrent glioblastoma multiforme (GBM) and compared survival to Gliadel Wafers (GW). The objectives of this retrospective evaluation were to assess: (1) catheter positioning in relation to imaging features and (2) to examine the potential impact of catheter positioning, overall catheter placement and imaging features on long term clinical outcome in the PRECISE study. Catheter positioning and overall catheter placement were scored and used as a surrogate of adequate placement. Imaging studies obtained on day 43 and day 71 after resection were each retrospectively reviewed. Catheter positioning scores, catheter overall placement scores, local tumor control and imaging change scores were reviewed and correlated using Generalized Linear Mixed Models. Cox PH regression analysis was used to examine whether these imaging based variables predicted overall survival (OS) and progression free survival (PFS) after adjusting for age and KPS. Of 180 patients in the CED group, 20 patients did not undergo gross total resection. Of the remaining 160 patients only 53% of patients had fully conforming catheters in respect to overall placement and 51% had adequate catheter positioning scores. Better catheter positioning scores were not correlated with local tumor control (P = 0.61) or imaging change score (P = 0.86). OS and PFS were not correlated with catheter positioning score (OS: P = 0.53; PFS: P = 0.72 respectively), overall placement score (OS: P = 0.55; PFS: P = 0.35) or imaging changes on day 43 MRI (P = 0.88). Catheter positioning scores and overall catheter placement scores were not associated with clinical outcome in this large prospective trial.


Assuntos
Catéteres , Neoplasias do Sistema Nervoso Central/diagnóstico , Neoplasias do Sistema Nervoso Central/tratamento farmacológico , Exotoxinas/uso terapêutico , Glioblastoma/diagnóstico , Glioblastoma/tratamento farmacológico , Fatores Imunológicos/uso terapêutico , Interleucina-13/uso terapêutico , Imageamento por Ressonância Magnética , Neoplasias do Sistema Nervoso Central/mortalidade , Terapia Combinada , Intervalo Livre de Doença , Seguimentos , Glioblastoma/mortalidade , Humanos , Cooperação Internacional , Avaliação de Estado de Karnofsky , Modelos Lineares , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/tratamento farmacológico , Razão de Chances , Modelos de Riscos Proporcionais , Proteínas Recombinantes de Fusão , Estudos Retrospectivos , Resultado do Tratamento
2.
Neurooncol Adv ; 2(1): vdaa033, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32642691

RESUMO

BACKGROUND: Treatment options for patients suffering brainstem gliomas are quite limited as surgery is not an option against intrinsic tumors at brainstem and chemotherapy generally failed to demonstrate its efficacy. Intracerebral convection-enhanced delivery (CED) is a novel approach for administering chemotherapy to patients with brain tumors. We present the results of phase I trial of CED of nimustine hydrochloride (ACNU), designed to determine the maximum tolerable concentration of ACNU, for patients with recurrent brainstem gliomas. METHODS: Sixteen patients, aged 3-81 years old, suffering from recurrent brainstem gliomas, including diffuse intrinsic pontine glioma patients as well as patients with recurrent gliomas that originated from non-brainstem sites, were enrolled in this trial between February 2011 and April 2016. The dose/concentration escalation trial included 3 dose/concentration groups (0.25, 0.5, and 0.75 mg/mL, all at 7 mL) to determine the safety and tolerability of CED of ACNU. Real-time monitoring of drug distribution was performed by mixing gadolinium-tetraazacyclododecanetetraacetic acid (Gd-DOTA) in the infusion solution. CED of ACNU was given in combination with oral or intravenous temozolomide chemotherapy. RESULTS: CED of ACNU demonstrated antitumor activity, as assessed by radiographic changes and prolonged overall survival. The recommended dosage was 0.75 mg/mL. Drug-associated toxicity was minimal. CONCLUSIONS: Intracerebral CED of ACNU under real-time monitoring of drug distribution, in combination with systemic temozolomide, was well tolerated among patients with recurrent brainstem gliomas. The safety and efficacy observed suggest the clinical benefits of this strategy against this devastating disease. Based on this phase I study, further clinical development of ACNU is warranted.

3.
J Neurosurg ; 131(6): 1812-1818, 2018 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-30579270

RESUMO

OBJECTIVE: Convection-enhanced delivery (CED) has been explored as a therapeutic strategy for diffuse intrinsic pontine glioma (DIPG). Variables that may affect tolerance include infusate volume, infusion rate, catheter trajectory, and target position. Supratentorial approaches for catheter placement and infusate distribution patterns may conflict with corticospinal tracts (CSTs). The clinical relevance of these anatomical constraints has not been described. The authors report their experience using CED in the brainstem as it relates to anatomical CST conflict and association with clinical tolerance. METHODS: In a phase I clinical trial of CED for DIPG (clinical trial registration no. NCT01502917, clinicaltrials.gov), a flexible infusion catheter was placed with MRI guidance for infusion of 124I-8H9, a radioimmunotherapeutic agent. Intra- and postprocedural MR images were analyzed to identify catheter trajectories and changes in T2-weighted signal intensity to approximate volume of distribution (Vd). Intersection of CST by the catheter and overlap between Vd and CST were recorded and their correlation with motor deficits was evaluated. RESULTS: Thirty-one patients with a mean age of 7.6 years (range 3.2-18 years) underwent 39 catheter insertions for CED between 2012 and 2017. Thirty catheter insertions had tractography data available for analysis. The mean trajectory length was 105.5 mm (range 92.7-121.6 mm). The mean number of intersections of CST by catheter was 2.2 (range 0-3) and the mean intersecting length was 18.9 mm (range 0-44.2 mm). The first 9 infusions in the highest dose level (range 3.84-4.54 ml infusate) were analyzed for Vd overlap with CST. In this group, the mean age was 7.6 years (range 5.8-10.3 years), the mean trajectory length was 109.5 mm (range 102.6-122.3 mm), and the mean overlap between Vd and CST was 5.5 cm3. For catheter placement-related adverse events, 1 patient (3%) had worsening of a contralateral facial nerve palsy following the procedure with two CST intersections, an intersecting distance of 31.7 mm, and an overlap between Vd and CST of 3.64 cm3. For infusion-related adverse events, transient postinfusion deficits were noted in 3 patients in the highest dose level, with a mean number of 2 intersections of CST by catheter, mean intersecting length of 12.9 mm, and mean overlap between Vd and CST of 6.3 cm3. CONCLUSIONS: A supratentorial approach to the brainstem crossing the CST resulted in one worsened neurological deficit. There does not appear to be a significant risk requiring avoidance of dominant motor fiber tracts with catheter trajectory planning. There was no correlation between Vd-CST overlap and neurological adverse events in this cohort.Clinical trial registration no.: NCT01502917 (clinicaltrials.gov).


Assuntos
Neoplasias do Tronco Encefálico/diagnóstico por imagem , Tronco Encefálico/diagnóstico por imagem , Convecção , Sistemas de Liberação de Medicamentos/métodos , Radioisótopos do Iodo/administração & dosagem , Tratos Piramidais/diagnóstico por imagem , Adolescente , Antineoplásicos/administração & dosagem , Tronco Encefálico/efeitos dos fármacos , Neoplasias do Tronco Encefálico/tratamento farmacológico , Catéteres , Criança , Pré-Escolar , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Tratos Piramidais/efeitos dos fármacos , Radioimunoterapia/métodos
4.
World Neurosurg ; 89: 272-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26862025

RESUMO

BACKGROUND: In a phase 1 trial conducted at our institute, convection-enhanced delivery (CED) was used to administrate the Delta-24-RGD adenovirus in patients with a recurrent glioblastoma multiforme. Infusion of the virus was preceded by a gadolinium-conjugated diethylenetriamine penta-acetic acid (Gd-DTPA) test-infusion. In the present study, we analyzed the results of Gd-DTPA test infusion through 50 catheters. METHODS: Thirteen adults with a recurrent glioblastoma multiforme were enrolled in a larger phase 1 multicenter, dose-finding study, in which a conditionally replication-competent adenovirus was administered by CED. Up to 4 infusion catheters per patient were placed intra- and/or peritumorally. Before infusion of the virus, a Gd-DTPA infusion was performed for 6 hours, directly followed by a MRI scan. The MRIs were evaluated for catheter position, Gd-DTPA distribution outcome, and contrast leakage. RESULTS: Leakage of Gd-DTPA into the cerebrospinal fluid was detected in 17 of the 50 catheters (34%). Sulcus crossing was the most frequent cause of leakage. In 8 cases, leakage could only be detected on the fluid-attenuated inversion recovery sequence. Nonleaking catheters showed a significantly larger Gd-DTPA distribution fraction (volume of distribution/volume of infusion) than leaking catheters (P = 0.009). A significantly lower volume of distribution/volume of infusion was observed in intratumoral catheters, compared with peritumoral catheters (P = 0.004). Gd-DTPA test infusion did not result in significant changes in Karnofsky Performance Score and Neurological Status. CONCLUSIONS: Pre-CED treatment infusion of Gd-DTPA is an adequate and safe method to identify dysfunctional catheters. The use of an optimized drug delivery catheter is necessary to reduce leakage and improve the efficacy of intracerebral drug infusion.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Catéteres , Sistemas de Liberação de Medicamentos/instrumentação , Glioblastoma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Terapia Viral Oncolítica/instrumentação , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/terapia , Líquido Cefalorraquidiano/diagnóstico por imagem , Líquido Cefalorraquidiano/metabolismo , Meios de Contraste , Convecção , Dependovirus , Sistemas de Liberação de Medicamentos/métodos , Falha de Equipamento , Gadolínio DTPA , Glioblastoma/terapia , Humanos , Avaliação de Estado de Karnofsky , Terapia Viral Oncolítica/métodos , Fatores de Risco
5.
J Neurosurg ; 113(2): 301-9, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20020841

RESUMO

OBJECT: Convection-enhanced delivery (CED) is a novel intracerebral drug delivery technique with considerable promise for delivering therapeutic agents throughout the CNS. Despite this promise, Phase III clinical trials employing CED have failed to meet clinical end points. Although this may be due to inactive agents or a failure to rigorously validate drug targets, the authors have previously demonstrated that catheter positioning plays a major role in drug distribution using this technique. The purpose of the present work was to retrospectively analyze the expected drug distribution based on catheter positioning data available from the CED arm of the PRECISE trial. METHODS: Data on catheter positioning from all patients randomized to the CED arm of the PRECISE trial were available for analyses. BrainLAB iPlan Flow software was used to estimate the expected drug distribution. RESULTS: Only 49.8% of catheters met all positioning criteria. Still, catheter positioning score (hazard ratio 0.93, p = 0.043) and the number of optimally positioned catheters (hazard ratio 0.72, p = 0.038) had a significant effect on progression-free survival. Estimated coverage of relevant target volumes was low, however, with only 20.1% of the 2-cm penumbra surrounding the resection cavity covered on average. Although tumor location and resection cavity volume had no effect on coverage volume, estimations of drug delivery to relevant target volumes did correlate well with catheter score (p < 0.003), and optimally positioned catheters had larger coverage volumes (p < 0.002). Only overall survival (p = 0.006) was higher for investigators considered experienced after adjusting for patient age and Karnofsky Performance Scale score. CONCLUSIONS: The potential efficacy of drugs delivered by CED may be severely constrained by ineffective delivery in many patients. Routine use of software algorithms and alternative catheter designs and infusion parameters may improve the efficacy of drugs delivered by CED.


Assuntos
Antineoplásicos/farmacocinética , Neoplasias Encefálicas/tratamento farmacológico , Cateterismo/métodos , Sistemas de Liberação de Medicamentos/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Algoritmos , Antineoplásicos/administração & dosagem , Cateterismo/estatística & dados numéricos , Ensaios Clínicos Fase III como Assunto/métodos , Convecção , Sistemas de Liberação de Medicamentos/estatística & dados numéricos , Humanos , Interleucina-13 , Estimativa de Kaplan-Meier , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Software , Distribuição Tecidual , Falha de Tratamento