Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Strahlenther Onkol ; 199(7): 686-691, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37000223

RESUMO

PURPOSE: 4D CT imaging is an integral part of 4D radiotherapy workflows. However, 4D CT data often contain motion artifacts that mitigate treatment planning. Recently, breathing-adapted 4D CT (i4DCT) was introduced into clinical practice, promising artifact reduction in in-silico and phantom studies. Here, we present an image quality comparison study, pooling clinical patient data from two centers: a new i4DCT and a conventional spiral 4D CT patient cohort. METHODS: The i4DCT cohort comprises 129 and the conventional spiral 4D CT cohort 417 4D CT data sets of lung and liver tumor patients. All data were acquired for treatment planning. The study consists of three parts: illustration of image quality in selected patients of the two cohorts with similar breathing patterns; an image quality expert rater study; and automated analysis of the artifact frequency. RESULTS: Image data of the patients with similar breathing patterns underline artifact reduction by i4DCT compared to conventional spiral 4D CT. Based on a subgroup of 50 patients with irregular breathing patterns, the rater study reveals a fraction of almost artifact-free scans of 89% for i4DCT and only 25% for conventional 4D CT; the quantitative analysis indicated a reduction of artifact frequency by 31% for i4DCT. CONCLUSION: The results demonstrate 4D CT image quality improvement for patients with irregular breathing patterns by breathing-adapted 4D CT in this first corresponding clinical data image quality comparison study.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Humanos , Tomografia Computadorizada Quadridimensional/métodos , Respiração , Pulmão , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Movimento (Física)
2.
Stroke ; 52(11): 3497-3504, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34496622

RESUMO

Background and Purpose: Mechanical thrombectomy is an established procedure for treatment of acute ischemic stroke. Mechanical thrombectomy success is commonly assessed by the Thrombolysis in Cerebral Infarction (TICI) score, assigned by visual inspection of X-ray digital subtraction angiography data. However, expert-based TICI scoring is highly observer-dependent. This represents a major obstacle for mechanical thrombectomy outcome comparison in, for instance, multicentric clinical studies. Focusing on occlusions of the M1 segment of the middle cerebral artery, the present study aimed to develop a deep learning (DL) solution to automated and, therefore, objective TICI scoring, to evaluate the agreement of DL- and expert-based scoring, and to compare corresponding numbers to published scoring variability of clinical experts. Methods: The study comprises 2 independent datasets. For DL system training and initial evaluation, an in-house dataset of 491 digital subtraction angiography series and modified TICI scores of 236 patients with M1 occlusions was collected. To test the model generalization capability, an independent external dataset with 95 digital subtraction angiography series was analyzed. Characteristics of the DL system were modeling TICI scoring as ordinal regression, explicit consideration of the temporal image information, integration of physiological knowledge, and modeling of inherent TICI scoring uncertainties. Results: For the in-house dataset, the DL system yields Cohen's kappa, overall accuracy, and specific agreement values of 0.61, 71%, and 63% to 84%, respectively, compared with the gold standard: the expert rating. Values slightly drop to 0.52/64%/43% to 87% when the model is, without changes, applied to the external dataset. After model updating, they increase to 0.65/74%/60% to 90%. Literature Cohen's kappa values for expert-based TICI scoring agreement are in the order of 0.6. Conclusions: The agreement of DL- and expert-based modified TICI scores in the range of published interobserver variability of clinical experts highlights the potential of the proposed DL solution to automated TICI scoring.


Assuntos
Infarto Cerebral/patologia , Aprendizado Profundo , Interpretação de Imagem Assistida por Computador/métodos , Neuroimagem/métodos , Angiografia Digital , Infarto Cerebral/terapia , Humanos , Estudo de Prova de Conceito , Trombectomia
3.
Int J Mol Sci ; 22(21)2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34769223

RESUMO

Live-cell Ca2+ fluorescence microscopy is a cornerstone of cellular signaling analysis and imaging. The demand for high spatial and temporal imaging resolution is, however, intrinsically linked to a low signal-to-noise ratio (SNR) of the acquired spatio-temporal image data, which impedes on the subsequent image analysis. Advanced deconvolution and image restoration algorithms can partly mitigate the corresponding problems but are usually defined only for static images. Frame-by-frame application to spatio-temporal image data neglects inter-frame contextual relationships and temporal consistency of the imaged biological processes. Here, we propose a variational approach to time-dependent image restoration built on entropy-based regularization specifically suited to process low- and lowest-SNR fluorescence microscopy data. The advantage of the presented approach is demonstrated by means of four datasets: synthetic data for in-depth evaluation of the algorithm behavior; two datasets acquired for analysis of initial Ca2+ microdomains in T-cells; finally, to illustrate the transferability of the methodical concept to different applications, one dataset depicting spontaneous Ca2+ signaling in jGCaMP7b-expressing astrocytes. To foster re-use and reproducibility, the source code is made publicly available.


Assuntos
Algoritmos , Sinalização do Cálcio , Cálcio/metabolismo , Processamento de Imagem Assistida por Computador , Modelos Teóricos , Humanos , Células Jurkat , Microscopia de Fluorescência , Razão Sinal-Ruído
4.
Strahlenther Onkol ; 196(5): 421-443, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32211939

RESUMO

This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.


Assuntos
Consenso , Garantia da Qualidade dos Cuidados de Saúde/normas , Radiocirurgia/normas , Alemanha , Doses de Radiação , Sociedades Médicas
5.
Radiology ; 290(2): 479-487, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30526358

RESUMO

Purpose To investigate the feasibility of tumor type prediction with MRI radiomic image features of different brain metastases in a multiclass machine learning approach for patients with unknown primary lesion at the time of diagnosis. Materials and methods This single-center retrospective analysis included radiomic features of 658 brain metastases from T1-weighted contrast material-enhanced, T1-weighted nonenhanced, and fluid-attenuated inversion recovery (FLAIR) images in 189 patients (101 women, 88 men; mean age, 61 years; age range, 32-85 years). Images were acquired over a 9-year period (from September 2007 through December 2016) with different MRI units, reflecting heterogeneous image data. Included metastases originated from breast cancer (n = 143), small cell lung cancer (n = 151), non-small cell lung cancer (n = 225), gastrointestinal cancer (n = 50), and melanoma (n = 89). A total of 1423 quantitative image features and basic clinical data were evaluated by using random forest machine learning algorithms. Validation was performed with model-external fivefold cross validation. Comparative analysis of 10 randomly drawn cross-validation sets verified the stability of the results. The classifier performance was compared with predictions from a respective conventional reading by two radiologists. Results Areas under the receiver operating characteristic curve of the five-class problem ranged between 0.64 (for non-small cell lung cancer) and 0.82 (for melanoma); all P values were less than .01. Prediction performance of the classifier was superior to the radiologists' readings. Highest differences were observed for melanoma, with a 17-percentage-point gain in sensitivity compared with the sensitivity of both readers; P values were less than .02. Conclusion Quantitative features of routine brain MR images used in a machine learning classifier provided high discriminatory accuracy in predicting the tumor type of brain metastases. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/secundário , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Neoplasias Encefálicas/classificação , Neoplasias Encefálicas/epidemiologia , Feminino , Humanos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Neoplasias/patologia , Estudos Retrospectivos
6.
Z Gastroenterol ; 57(6): 767-780, 2019 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-31170744

RESUMO

Artificial neural networks, as a specific approach towards artificial intelligence (AI), can open up a variety of new perspectives for endoscopy, such as automated lesion detection and the precise prediction of a lesion's histology by its endoscopic appearance. Whilst early experiments do suggest an enormous potential for these methods, public expectations on their application in various fields of medicine sometimes appear to be grounded on general fascination rather than detailed understanding of their inner workings. Based on a selective review of the literature, this article shall convey an intuitive understanding of the underlying methods in order to help close the gap between functioning and fascination and allow for a realistic discussion of their perspectives and limitations in endoscopy.After decades of research, the success of deep neuronal networks in image classification has provoked rising interest for AI during recent years. We quickly touch upon the developments surrounding this breakthrough and the reasons for their impact on various disciplines much beyond computer science. Through a comparison with the functioning of the human vision system, we aim to understand the mechanisms of these techniques and their success in computer vision tasks in detail. Based on these considerations, we analyse the functioning of some important AI applications in endoscopy, deduce specific limitations and perspectives, discuss the current state of their evaluation in practical endoscopy and make a plea for the need for additional and realistic tests. Moreover, we seek to give an impression of some further specific applications that can currently be foreseen and how these can shape the role that AI might finally acquire in the routine clinical practice of GI endoscopy.


Assuntos
Inteligência Artificial , Endoscopia/tendências , Medicina/tendências , Redes Neurais de Computação , Aprendizado Profundo , Humanos , Processamento de Imagem Assistida por Computador
7.
Strahlenther Onkol ; 194(6): 570-579, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29450592

RESUMO

BACKGROUND AND PURPOSE: Radiotherapy of extracranial metastases changed from normofractioned 3D CRT to extreme hypofractionated stereotactic treatment using VMAT beam techniques. Random interaction between tumour motion and dynamically changing beam parameters might result in underdosage of the CTV even for an appropriately dimensioned ITV (interplay effect). This study presents a clinical scenario of extreme hypofractionated stereotactic treatment and analyses the impact of interplay effects on CTV dose coverage. METHODS: For a thoracic/abdominal phantom with an integrated high-resolution detector array placed on a 4D motion platform, dual-arc treatment plans with homogenous target coverage were created using a common VMAT technique and delivered in a single fraction. CTV underdosage through interplay effects was investigated by comparing dose measurements with and without tumour motion during plan delivery. RESULTS: Our study agrees with previous works that pointed out insignificant interplay effects on target coverage for very regular tumour motion patterns like simple sinusoidal motion. However, we identified and illustrated scenarios that are likely to result in a clinically relevant CTV underdosage. For tumour motion with abnormal variability, target coverage quantified by the CTV area receiving more than 98% of the prescribed dose decreased to 78% compared to 100% at static dose measurement. CONCLUSION: This study is further proof of considerable influence of interplay effects on VMAT dose delivery in stereotactic radiotherapy. For selected conditions of an exemplary scenario, interplay effects and related motion-induced target underdosage primarily occurred in tumour motion pattern with increased motion variability and VMAT plan delivery using complex MLC dose modulation.


Assuntos
Hipofracionamento da Dose de Radiação , Radiometria/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia , Radioterapia de Intensidade Modulada/métodos , Revelação da Verdade , Movimentos dos Órgãos/fisiologia , Imagens de Fantasmas , Fatores de Risco
10.
J Comput Assist Tomogr ; 40(6): 899-906, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27331925

RESUMO

OBJECTIVE: We propose a computer-aided method for regional ventilation analysis and observation of lung diseases in temporally resolved magnetic resonance imaging (4D MRI). METHODS: A shape model-based segmentation and registration workflow was used to create an atlas-derived reference system in which regional tissue motion can be quantified and multimodal image data can be compared regionally. Model-based temporal registration of the lung surfaces in 4D MRI data was compared with the registration of 4D computed tomography (CT) images. A ventilation analysis was performed on 4D MR images of patients with lung fibrosis; 4D MR ventilation maps were compared with corresponding diagnostic 3D CT images of the patients and 4D CT maps of subjects without impaired lung function (serving as reference). RESULTS: Comparison between the computed patient-specific 4D MR regional ventilation maps and diagnostic CT images shows good correlation in conspicuous regions. Comparison to 4D CT-derived ventilation maps supports the plausibility of the 4D MR maps. Dynamic MRI-based flow-volume loops and spirograms further visualize the free-breathing behavior. CONCLUSIONS: The proposed methods allow for 4D MR-based regional analysis of tissue dynamics and ventilation in spontaneous breathing and comparison of patient data. The proposed atlas-based reference coordinate system provides an automated manner of annotating and comparing multimodal lung image data.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Fibrose Pulmonar/diagnóstico por imagem , Ventilação Pulmonar , Técnicas de Imagem de Sincronização Respiratória/métodos , Idoso , Simulação por Computador , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Fibrose Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
11.
Strahlenther Onkol ; 191(2): 161-71, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25238989

RESUMO

PURPOSE: To investigate the adequacy of three-dimensional (3D) Monte Carlo (MC) optimization (3DMCO) and the potential of four-dimensional (4D) dose renormalization (4DMCrenorm) and optimization (4DMCO) for CyberKnife (Accuray Inc., Sunnyvale, CA) radiotherapy planning in lung cancer. MATERIALS AND METHODS: For 20 lung tumors, 3DMCO and 4DMCO plans were generated with planning target volume (PTV5 mm) = gross tumor volume (GTV) plus 5 mm, assuming 3 mm for tracking errors (PTV3 mm) and 2 mm for residual organ deformations. Three fractions of 60 Gy were prescribed to ≥ 95 % of the PTV5 mm. Each 3DMCO plan was recalculated by 4D MC dose calculation (4DMCrecal) to assess the dosimetric impact of organ deformations. The 4DMCrecal plans were renormalized (4DMCrenorm) to 95 % dose coverage of the PTV5 mm for comparisons with the 4DMCO plans. A 3DMCO plan was considered adequate if the 4DMCrecal plan showed ≥ 95 % of the PTV3 mm receiving 60 Gy and doses to other organs at risk (OARs) were below the limits. RESULTS: In seven lesions, 3DMCO was inadequate, providing < 95 % dose coverage to the PTV3 mm. Comparison of 4DMCrecal and 3DMCO plans showed that organ deformations resulted in lower OAR doses. Renormalizing the 4DMCrecal plans could produce OAR doses higher than the tolerances in some 4DMCrenorm plans. Dose conformity of the 4DMCrenorm plans was inferior to that of the 3DMCO and 4DMCO plans. The 4DMCO plans did not always achieve OAR dose reductions compared to 3DMCO and 4DMCrenorm plans. CONCLUSION: This study indicates that 3DMCO with 2 mm margins for organ deformations may be inadequate for Cyberknife-based lung stereotactic body radiotherapy (SBRT). Renormalizing the 4DMCrecal plans could produce degraded dose conformity and increased OAR doses; 4DMCO can resolve this problem.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Imageamento Tridimensional/métodos , Neoplasias Pulmonares/cirurgia , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Robótica , Humanos , Neoplasias Pulmonares/patologia , Dosagem Radioterapêutica , Carga Tumoral
12.
Med Phys ; 51(5): 3173-3183, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38536107

RESUMO

BACKGROUND: Stereotactic body radiotherapy of thoracic and abdominal tumors has to account for respiratory intrafractional tumor motion. Commonly, an external breathing signal is continuously acquired that serves as a surrogate of the tumor motion and forms the basis of strategies like breathing-guided imaging and gated dose delivery. However, due to inherent system latencies, there exists a temporal lag between the acquired respiratory signal and the system response. Respiratory signal prediction models aim to compensate for the time delays and to improve imaging and dose delivery. PURPOSE: The present study explores and compares six state-of-the-art machine and deep learning-based prediction models, focusing on real-time and real-world applicability. All models and data are provided as open source and data to ensure reproducibility of the results and foster reuse. METHODS: The study was based on 2502 breathing signals ( t t o t a l ≈ 90 $t_{total} \approx 90$  h) acquired during clinical routine, split into independent training (50%), validation (20%), and test sets (30%). Input signal values were sampled from noisy signals, and the target signal values were selected from corresponding denoised signals. A standard linear prediction model (Linear), two state-of-the-art models in general univariate signal prediction (Dlinear, Xgboost), and three deep learning models (Lstm, Trans-Enc, Trans-TSF) were chosen. The prediction performance was evaluated for three different prediction horizons (480, 680, and 920 ms). Moreover, the robustness of the different models when applied to atypical, that is, out-of-distribution (OOD) signals, was analyzed. RESULTS: The Lstm model achieved the lowest normalized root mean square error for all prediction horizons. The prediction errors only slightly increased for longer horizons. However, a substantial spread of the error values across the test signals was observed. Compared to typical, that is, in-distribution test signals, the prediction accuracy of all models decreased when applied to OOD signals. The more complex deep learning models Lstm and Trans-Enc showed the least performance loss, while the performance of simpler models like Linear dropped the most. Except for Trans-Enc, inference times for the different models allowed for real-time application. CONCLUSION: The application of the Lstm model achieved the lowest prediction errors. Simpler prediction filters suffer from limited signal history access, resulting in a drop in performance for OOD signals.


Assuntos
Benchmarking , Aprendizado de Máquina , Radiocirurgia , Respiração , Radiocirurgia/métodos , Humanos , Fatores de Tempo , Aprendizado Profundo , Tomografia Computadorizada Quadridimensional
13.
Front Neurosci ; 18: 1296357, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38298911

RESUMO

Background: Voxel-based lesion symptom mapping (VLSM) assesses the relation of lesion location at a voxel level with a specific clinical or functional outcome measure at a population level. Spatial normalization, that is, mapping the patient images into an atlas coordinate system, is an essential pre-processing step of VLSM. However, no consensus exists on the optimal registration approach to compute the transformation nor are downstream effects on VLSM statistics explored. In this work, we evaluate four registration approaches commonly used in VLSM pipelines: affine (AR), nonlinear (NLR), nonlinear with cost function masking (CFM), and enantiomorphic registration (ENR). The evaluation is based on a standard VLSM scenario: the analysis of statistical relations of brain voxels and regions in imaging data acquired early after stroke onset with follow-up modified Rankin Scale (mRS) values. Materials and methods: Fluid-attenuated inversion recovery (FLAIR) MRI data from 122 acute ischemic stroke patients acquired between 2 and 3 days after stroke onset and corresponding lesion segmentations, and 30 days mRS values from a European multicenter stroke imaging study (I-KNOW) were available and used in this study. The relation of the voxel location with follow-up mRS was assessed by uni- as well as multi-variate statistical testing based on the lesion segmentations registered using the four different methods (AR, NLR, CFM, ENR; implementation based on the ANTs toolkit). Results: The brain areas evaluated as important for follow-up mRS were largely consistent across the registration approaches. However, NLR, CFM, and ENR led to distortions in the patient images after the corresponding nonlinear transformations were applied. In addition, local structures (for instance the lateral ventricles) and adjacent brain areas remained insufficiently aligned with corresponding atlas structures even after nonlinear registration. Conclusions: For VLSM study designs and imaging data similar to the present work, an additional benefit of nonlinear registration variants for spatial normalization seems questionable. Related distortions in the normalized images lead to uncertainties in the VLSM analyses and may offset the theoretical benefits of nonlinear registration.

14.
Front Immunol ; 15: 1258119, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38426095

RESUMO

CD8+ T cells are a crucial part of the adaptive immune system, responsible for combating intracellular pathogens and tumor cells. The initial activation of T cells involves the formation of highly dynamic Ca2+ microdomains. Recently, purinergic signaling was shown to be involved in the formation of the initial Ca2+ microdomains in CD4+ T cells. In this study, the role of purinergic cation channels, particularly P2X4 and P2X7, in CD8+ T cell signaling from initial events to downstream responses was investigated, focusing on various aspects of T cell activation, including Ca2+ microdomains, global Ca2+ responses, NFAT-1 translocation, cytokine expression, and proliferation. While Ca2+ microdomain formation was significantly reduced in the first milliseconds to seconds in CD8+ T cells lacking P2X4 and P2X7 channels, global Ca2+ responses over minutes were comparable between wild-type (WT) and knockout cells. However, the onset velocity was reduced in P2X4-deficient cells, and P2X4, as well as P2X7-deficient cells, exhibited a delayed response to reach a certain level of free cytosolic Ca2+ concentration ([Ca2+]i). NFAT-1 translocation, a crucial transcription factor in T cell activation, was also impaired in CD8+ T cells lacking P2X4 and P2X7. In addition, the expression of IFN-γ, a major pro-inflammatory cytokine produced by activated CD8+ T cells, and Nur77, a negative regulator of T cell activation, was significantly reduced 18h post-stimulation in the knockout cells. In line, the proliferation of T cells after 3 days was also impaired in the absence of P2X4 and P2X7 channels. In summary, the study demonstrates that purinergic signaling through P2X4 and P2X7 enhances initial Ca2+ events during CD8+ T cell activation and plays a crucial role in regulating downstream responses, including NFAT-1 translocation, cytokine expression, and proliferation on multiple timescales. These findings suggest that targeting purinergic signaling pathways may offer potential therapeutic interventions.


Assuntos
Linfócitos T CD8-Positivos , Transdução de Sinais , Citocinas
15.
Bioengineering (Basel) ; 10(8)2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37627780

RESUMO

Is self-supervised deep learning (DL) for medical image analysis already a serious alternative to the de facto standard of end-to-end trained supervised DL? We tackle this question for medical image classification, with a particular focus on one of the currently most limiting factor of the field: the (non-)availability of labeled data. Based on three common medical imaging modalities (bone marrow microscopy, gastrointestinal endoscopy, dermoscopy) and publicly available data sets, we analyze the performance of self-supervised DL within the self-distillation with no labels (DINO) framework. After learning an image representation without use of image labels, conventional machine learning classifiers are applied. The classifiers are fit using a systematically varied number of labeled data (1-1000 samples per class). Exploiting the learned image representation, we achieve state-of-the-art classification performance for all three imaging modalities and data sets with only a fraction of between 1% and 10% of the available labeled data and about 100 labeled samples per class.

16.
Med Phys ; 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38055336

RESUMO

BACKGROUND: 4D CT imaging is an essential component of radiotherapy of thoracic and abdominal tumors. 4D CT images are, however, often affected by artifacts that compromise treatment planning quality and image information reliability. PURPOSE: In this work, deep learning (DL)-based conditional inpainting is proposed to restore anatomically correct image information of artifact-affected areas. METHODS: The restoration approach consists of a two-stage process: DL-based detection of common interpolation (INT) and double structure (DS) artifacts, followed by conditional inpainting applied to the artifact areas. In this context, conditional refers to a guidance of the inpainting process by patient-specific image data to ensure anatomically reliable results. The study is based on 65 in-house 4D CT images of lung cancer patients (48 with only slight artifacts, 17 with pronounced artifacts) and two publicly available 4D CT data sets that serve as independent external test sets. RESULTS: Automated artifact detection revealed a ROC-AUC of 0.99 for INT and of 0.97 for DS artifacts (in-house data). The proposed inpainting method decreased the average root mean squared error (RMSE) by 52 % (INT) and 59 % (DS) for the in-house data. For the external test data sets, the RMSE improvement is similar (50 % and 59 %, respectively). Applied to 4D CT data with pronounced artifacts (not part of the training set), 72 % of the detectable artifacts were removed. CONCLUSIONS: The results highlight the potential of DL-based inpainting for restoration of artifact-affected 4D CT data. Compared to recent 4D CT inpainting and restoration approaches, the proposed methodology illustrates the advantages of exploiting patient-specific prior image information.

17.
Med Phys ; 50(12): 7539-7547, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37831550

RESUMO

BACKGROUND: Respiratory signal-guided 4D CT sequence scanning such as the recently introduced Intelligent 4D CT (i4DCT) approach reduces image artifacts compared to conventional 4D CT, especially for irregular breathing. i4DCT selects beam-on periods during scanning such that data sufficiency conditions are fulfilled for each couch position. However, covering entire breathing cycles during beam-on periods leads to redundant projection data and unnecessary dose to the patient during long exhalation phases. PURPOSE: We propose and evaluate the feasibility of respiratory signal-guided dose modulation (i.e., temporary reduction of the CT tube current) to reduce the i4DCT imaging dose while maintaining high projection data coverage for image reconstruction. METHODS: The study is designed as an in-silico feasibility study. Dose down- and up-regulation criteria were defined based on the patients' breathing signals and their representative breathing cycle learned before and during scanning. The evaluation (including an analysis of the impact of the dose modulation criteria parameters) was based on 510 clinical 4D CT breathing curves. Dose reduction was determined as the fraction of the downregulated dose delivery time to the overall beam-on time. Furthermore, under the assumption of a 10-phase 4D CT and amplitude-based reconstruction, beam-on periods were considered negatively affected by dose modulation if the downregulation period covered an entire phase-specific amplitude range for a specific breathing phase (i.e., no appropriate reconstruction of the phase image possible for this specific beam-on period). Corresponding phase-specific amplitude bins are subsequently denoted as compromised bins. RESULTS: Dose modulation resulted in a median dose reduction of 10.4% (lower quartile: 7.4%, upper quartile: 13.8%, maximum: 28.6%; all values corresponding to a default parameterization of the dose modulation criteria). Compromised bins were observed in 1.0% of the beam-on periods (72 / 7370 periods) and affected 10.6% of the curves (54/510 curves). The extent of possible dose modulation depends strongly on the individual breathing patterns and is weakly correlated with the median breathing cycle length (Spearman correlation coefficient 0.22, p < 0.001). Moreover, the fraction of beam-on periods with compromised bins is weakly anti-correlated with the patient's median breathing cycle length (Spearman correlation coefficient -0.24; p < 0.001). Among the curves with the 17% longest average breathing cycles, no negatively affected beam-on periods were observed. CONCLUSION: Respiratory signal-guided dose modulation for i4DCT imaging is feasible and promises to significantly reduce the imaging dose with little impact on projection data coverage. However, the impact on image quality remains to be investigated in a follow-up study.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Humanos , Tomografia Computadorizada Quadridimensional/métodos , Estudos de Viabilidade , Redução da Medicação , Seguimentos , Respiração
18.
Front Immunol ; 14: 1299435, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38274810

RESUMO

Ca2+ microdomains play a key role in intracellular signaling processes. For instance, they mediate the activation of T cells and, thus, the initial adaptive immune system. They are, however, also of utmost importance for activation of other cells, and a detailed understanding of the dynamics of these spatially localized Ca2+ signals is crucial for a better understanding of the underlying signaling processes. A typical approach to analyze Ca2+ microdomain dynamics is live cell fluorescence microscopy imaging. Experiments usually involve imaging a larger number of cells of different groups (for instance, wild type and knockout cells), followed by a time consuming image and data analysis. With DARTS, we present a modular Python pipeline for efficient Ca2+ microdomain analysis in live cell imaging data. DARTS (Deconvolution, Analysis, Registration, Tracking, and Shape normalization) provides state-of-the-art image postprocessing options like deep learning-based cell detection and tracking, spatio-temporal image deconvolution, and bleaching correction. An integrated automated Ca2+ microdomain detection offers direct access to global statistics like the number of microdomains for cell groups, corresponding signal intensity levels, and the temporal evolution of the measures. With a focus on bead stimulation experiments, DARTS provides a so-called dartboard projection analysis and visualization approach. A dartboard projection covers spatio-temporal normalization of the bead contact areas and cell shape normalization onto a circular template that enables aggregation of the spatiotemporal information of the microdomain detection results for the individual cells of the cell groups of interest. The dartboard visualization allows intuitive interpretation of the spatio-temporal microdomain dynamics at the group level. The application of DARTS is illustrated by three use cases in the context of the formation of initial Ca2+ microdomains after cell stimulation. DARTS is provided as an open-source solution and will be continuously extended upon the feedback of the community. Code available at: 10.5281/zenodo.10459243.


Assuntos
Boidae , Animais , Microscopia de Fluorescência , Linfócitos T/metabolismo
19.
Cancers (Basel) ; 15(11)2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37296843

RESUMO

Discordance and conversion of receptor expressions in metastatic lesions and primary tumors is often observed in patients with brain metastases from breast cancer. Therefore, personalized therapy requires continuous monitoring of receptor expressions and dynamic adaptation of applied targeted treatment options. Radiological in vivo techniques may allow receptor status tracking at high frequencies at low risk and cost. The present study aims to investigate the potential of receptor status prediction through machine-learning-based analysis of radiomic MR image features. The analysis is based on 412 brain metastases samples from 106 patients acquired between 09/2007 and 09/2021. Inclusion criteria were as follows: diagnosed cerebral metastases from breast cancer; histopathology reports on progesterone (PR), estrogen (ER), and human epidermal growth factor 2 (HER2) receptor status; and availability of MR imaging data. In total, 3367 quantitative features of T1 contrast-enhanced, T1 non-enhanced, and FLAIR images and corresponding patient age were evaluated utilizing random forest algorithms. Feature importance was assessed using Gini impurity measures. Predictive performance was tested using 10 permuted 5-fold cross-validation sets employing the 30 most important features of each training set. Receiver operating characteristic areas under the curves of the validation sets were 0.82 (95% confidence interval [0.78; 0.85]) for ER+, 0.73 [0.69; 0.77] for PR+, and 0.74 [0.70; 0.78] for HER2+. Observations indicate that MR image features employed in a machine learning classifier could provide high discriminatory accuracy in predicting the receptor status of brain metastases from breast cancer.

20.
Sci Signal ; 16(790): eabn9405, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37339181

RESUMO

During an immune response, T cells migrate from blood vessel walls into inflamed tissues by migrating across the endothelium and through extracellular matrix (ECM). Integrins facilitate T cell binding to endothelial cells and ECM proteins. Here, we report that Ca2+ microdomains observed in the absence of T cell receptor (TCR)/CD3 stimulation are initial signaling events triggered by adhesion to ECM proteins that increase the sensitivity of primary murine T cells to activation. Adhesion to the ECM proteins collagen IV and laminin-1 increased the number of Ca2+ microdomains in a manner dependent on the kinase FAK, phospholipase C (PLC), and all three inositol 1,4,5-trisphosphate receptor (IP3R) subtypes and promoted the nuclear translocation of the transcription factor NFAT-1. Mathematical modeling predicted that the formation of adhesion-dependent Ca2+ microdomains required the concerted activity of two to six IP3Rs and ORAI1 channels to achieve the increase in the Ca2+ concentration in the ER-plasma membrane junction that was observed experimentally and that required SOCE. Further, adhesion-dependent Ca2+ microdomains were important for the magnitude of the TCR-induced activation of T cells on collagen IV as assessed by the global Ca2+ response and NFAT-1 nuclear translocation. Thus, adhesion to collagen IV and laminin-1 sensitizes T cells through a mechanism involving the formation of Ca2+ microdomains, and blocking this low-level sensitization decreases T cell activation upon TCR engagement.


Assuntos
Células Endoteliais , Proteínas da Matriz Extracelular , Camundongos , Animais , Proteínas da Matriz Extracelular/metabolismo , Linfócitos T/metabolismo , Receptores de Antígenos de Linfócitos T/metabolismo , Colágeno/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA