Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Hepatology ; 79(2): 380-391, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37548928

RESUMO

BACKGROUND AND AIMS: The objective of this study is to determine the diagnostic accuracy of the American College of Radiology Contrast-Enhanced Ultrasound (CEUS) Liver Imaging Reporting and Data System LR-5 characterization for HCC diagnosis in North American or European patients. APPROACH AND RESULTS: A prospective multinational cohort study was performed from January 2018 through November 2022 at 11 academic and nonacademic centers in North America and Europe. Patients at risk for HCC with at least 1 liver observation not previously treated, identified on ultrasound (US), or multiphase CT or MRI performed as a part of standard clinical care were eligible for the study. All participants were examined with CEUS of the liver within 4 weeks of CT/MRI or tissue diagnosis to characterize up to 2 liver nodules per participant using ACR CEUS Liver Imaging Reporting and Data System. Definite HCC diagnosis on the initial CT/MRI, imaging follow-up, or histology for CT/MRI-indeterminate nodules were used as reference standards. A total of 545 nodules had confirmed reference standards in 480 patients, 73.8% were HCC, 5.5% were other malignancies, and 20.7% were nonmalignant. The specificity of CEUS LR-5 for HCC was 95.1% (95% CI 90.1%-97.7%), sensitivity 62.9% (95% CI 57.9%-67.7%), positive predictive value 97.3% (95% CI 94.5%-98.7%), and negative predictive value 47.7% (95% CI 41.7%-53.8%). In addition, benign CEUS characterization (LR-1 or LR-2) had 100% specificity and 100% positive predictive value for nonmalignant liver nodules. CONCLUSIONS: CEUS Liver Imaging Reporting and Data System provides an accurate categorization of liver nodules in participants at risk for HCC.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Estudos Prospectivos , Estudos de Coortes , Meios de Contraste , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Europa (Continente) , América do Norte , Sensibilidade e Especificidade
2.
Radiology ; 309(1): e230727, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37847138

RESUMO

Background Contrast-enhanced (CE) US has been studied for use in the detection of residual viable hepatocellular carcinoma (HCC) after locoregional therapy, but multicenter data are lacking. Purpose To compare two-dimensional (2D) and three-dimensional (3D) CE US diagnostic performance with that of CE MRI or CT, the current clinical standard, in the detection of residual viable HCC after transarterial chemoembolization (TACE) in a prospective multicenter trial. Materials and Methods Participants aged at least 21 years with US-visible HCC scheduled for TACE were consecutively enrolled at one of three participating academic medical centers from May 2016 to March 2022. Each underwent baseline 2D and 3D CE US before TACE, 2D and 3D CE US 1-2 weeks and/or 4-6 weeks after TACE, and CE MRI or CT 4-6 weeks after TACE. CE US and CE MRI or CT were evaluated by three fellowship-trained radiologists for the presence or absence of viable tumors and were compared with reference standards of pathology (18%), angiography on re-treatment after identification of residual disease at 1-2-month follow-up imaging (31%), 4-8-month CE MRI or CT (42%), or short-term (approximately 1-2 months) CE MRI or CT if clinically decompensated and estimated viability was greater than 50% at imaging (9%). Diagnostic performance criteria, including sensitivity and specificity, were obtained for each modality and time point with generalized estimating equation analysis. Results A total of 132 participants were included (mean age, 64 years ± 7 [SD], 87 male). Sensitivity of 2D CE US 4-6 weeks after TACE was 91% (95% CI: 84, 95), which was higher than that of CE MRI or CT (68%; 95% CI: 58, 76; P < .001). Sensitivity of 3D CE US 4-6 weeks after TACE was 89% (95% CI: 81, 94), which was higher than that of CE MRI or CT (P < .001), with no evidence of a difference from 2D CE US (P = .22). CE MRI or CT had 85% (95% CI: 76, 91) specificity, higher than that of 4-6-week 2D and 3D CE US (70% [95% CI: 56, 80] and 67% [95% CI: 53, 78], respectively; P = .046 and P = .023, respectively). No evidence of differences in any diagnostic criteria were observed between 1-2-week and 4-6-week 2D CE US (P > .21). Conclusion The 2D and 3D CE US examinations 4-6 weeks after TACE revealed higher sensitivity in the detection of residual HCC than CE MRI or CT, albeit with lower specificity. Importantly, CE US performance was independent of follow-up time. Clinical trial registration no. NCT02764801 © RSNA, 2023 Supplemental material is available for this article.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Meios de Contraste , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/patologia , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem , Adulto
3.
J Ultrasound Med ; 42(8): 1747-1756, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36807314

RESUMO

OBJECTIVES: Current diagnosis of nonalcoholic fatty liver disease (NAFLD) relies on biopsy or MR-based fat quantification. This prospective study explored the use of ultrasound with artificial intelligence for the detection of NAFLD. METHODS: One hundred and twenty subjects with clinical suspicion of NAFLD and 10 healthy volunteers consented to participate in this institutional review board-approved study. Subjects were categorized as NAFLD and non-NAFLD according to MR proton density fat fraction (PDFF) findings. Ultrasound images from 10 different locations in the right and left hepatic lobes were collected following a standard protocol. MRI-based liver fat quantification was used as the reference standard with >6.4% indicative of NAFLD. A supervised machine learning model was developed for assessment of NAFLD. To validate model performance, a balanced testing dataset of 24 subjects was used. Sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy with 95% confidence interval were calculated. RESULTS: A total of 1119 images from 106 participants was used for model development. The internal evaluation achieved an average precision of 0.941, recall of 88.2%, and precision of 89.0%. In the testing set AutoML achieved a sensitivity of 72.2% (63.1%-80.1%), specificity of 94.6% (88.7%-98.0%), positive predictive value (PPV) of 93.1% (86.0%-96.7%), negative predictive value of 77.3% (71.6%-82.1%), and accuracy of 83.4% (77.9%-88.0%). The average agreement for an individual subject was 92%. CONCLUSIONS: An ultrasound-based machine learning model for identification of NAFLD showed high specificity and PPV in this prospective trial. This approach may in the future be used as an inexpensive and noninvasive screening tool for identifying NAFLD in high-risk patients.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos , Inteligência Artificial , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Aprendizado de Máquina
4.
J Urol ; 207(1): 152-160, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34428090

RESUMO

PURPOSE: Urologists will benefit from an imaging modality which can assess intra and extraluminal characteristics of urethral strictures. We conducted a prospective pilot study evaluating the utility of contrast-enhanced ultrasound and shear wave elastography for the evaluation of bulbar urethral stricture disease. MATERIALS AND METHODS: Patients with a single, bulbar urethral stricture were prospectively recruited. Contrast-enhanced ultrasound and shear wave elastography were performed at the time of surgical repair and at 4 months' followup using an Aplio i800 scanner (Canon Medical Systems, Tustin, California) with an i8CX1 transducer. Sulfur hexafluoride lipid-type A microsphere ultrasound contrast (Lumason®, Bracco Imaging, Princeton, New Jersey) was injected retrograde through the urethra. Stiffness of the corpus spongiosum was measured at and adjacent to the stricture site. Stricture lengths based on retrograde urethrogram, grayscale ultrasound and contrast-enhanced ultrasound were correlated with measured intraoperative stricture length. RESULTS: Thirty men were enrolled. Contrast-enhanced ultrasound (R2=0.709) showed the best correlation with intraoperative measured stricture length compared to retrograde urethrogram (R2=0.016) or grayscale ultrasound (R2=0.471). Stiffness of the spongiosum was greater at the site of the stricture (32.6±5.4 vs 27.3±5.8 kPa, p=0.044) and in narrower caliber strictures (p=0.044) but did not differ by stricture length (p=0.182). At followup (4.3±1.1 months) contrast-enhanced ultrasound detected stricture recurrence with 80% sensitivity, 100% specificity, and 93% accuracy compared to cystoscopy. CONCLUSIONS: This pilot study demonstrates the ability of contrast-enhanced ultrasound and shear wave elastography to become safe, accurate, and potentially efficacious modalities for assessing bulbar urethral strictures and spongiofibrosis.


Assuntos
Meios de Contraste , Técnicas de Imagem por Elasticidade , Estreitamento Uretral/diagnóstico por imagem , Adulto , Idoso , Humanos , Masculino , Microesferas , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Ultrassonografia/métodos
5.
J Ultrasound Med ; 41(9): 2365-2371, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34866197

RESUMO

The feasibility of activating phase change contrast agents (PCCA) made from Definity (Lantheus Medical Imaging) using X-rays was investigated. A 10 mL of Definity PCCA (0.1 mL PCCA/mL) were injected into gelatin phantoms and irradiated using doses of 0, 30, 50, and 100 Gy. Size distribution and PCCA activation were measured after irradiation. Definity PCCAs were activated at a threshold of 50 Gy. Changes were visible with microscopy, visual inspection of T-flasks, and ultrasound imaging of gelatin phantoms. Moreover, increasing the radiation dose above 50 Gy appeared to further activate PCCA. These results indicate Definity PCCAs may be useful for ultrasound-based radiation dosimetry.


Assuntos
Meios de Contraste , Gelatina , Humanos , Imagens de Fantasmas , Radiação Ionizante , Ultrassonografia/métodos
6.
J Ultrasound Med ; 41(7): 1781-1789, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34724241

RESUMO

OBJECTIVES: Subharmonic aided pressure estimation (SHAPE) has been shown effective for noninvasively measuring hydrostatic fluid pressures in a variety of clinical applications. The objective of this study was to explore potential improvements in SHAPE sensitivity using monodisperse microbubbles. METHODS: Populations of monodisperse microbubbles were created using a commercially available microfluidics device (Solstice Pharmaceuticals). Size distributions were assessed using a Coulter Counter and stability of the distribution following fabrication was evaluated over 24 hours. Attenuation of the microbubble populations from 1 to 10 MHz was then quantified using single element transducers to identify each formulation's resonance frequency. Frequency spectra over increasing driving amplitudes were investigated to determine the nonlinear phases of subharmonic signal generation. SHAPE sensitivity was evaluated in a hydrostatic pressure-controlled water bath using a Logiq E10 scanner (GE Healthcare). RESULTS: Monodisperse lipid microbubble suspensions ranging from 2.4 to 5.3 µm in diameter were successfully created and they showed no discernable change in size distribution over 24 hours following activation. Calculated resonance frequencies ranged from 2.1 to 6.3 MHz and showed excellent correlation with microbubble diameter (R2 > 0.99). When investigating microbubble frequency response, subharmonic signal occurrence was shown to begin at 150 kPa peak negative pressure, grow up to 225 kPa, and saturate at approximately 250 kPa. Using the Logiq E10, monodisperse bubbles demonstrated a SHAPE sensitivity of -0.17 dB/mmHg, which was nearly twice the sensitivity of the commercial polydisperse microbubble currently being used in clinical trials. CONCLUSIONS: Monodisperse microbubbles have the potential to greatly improve the sensitivity of SHAPE for the noninvasive measurement of hydrostatic pressures.


Assuntos
Meios de Contraste , Microbolhas , Determinação da Pressão Arterial , Humanos , Transdutores , Ultrassonografia
7.
J Ultrasound Med ; 41(9): 2181-2189, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34850412

RESUMO

OBJECTIVES: Hepatic venous pressure gradient (HVPG) is considered the standard in quantifying portal hypertension, but can be unreliable in dialysis patients. A noninvasive ultrasound technique, subharmonic-aided pressure estimation (SHAPE), may be a valuable surrogate of these pressure estimates. This study compared SHAPE and HVPG with pathology findings for fibrosis in dialysis patients. METHODS: This was a subgroup study from an IRB-approved trial that included 20 patients on dialysis undergoing SHAPE examinations of portal and hepatic veins using a modified Logiq 9 scanner (GE, Waukesha, WI), during infusion of Sonazoid (GE Healthcare, Oslo, Norway). SHAPE was compared to HVPG and pathology findings using the Ludwig-Batts scoring system for fibrosis. Logistic regression, ROC analysis, and t-tests were used to compare HVPG and SHAPE with pathological findings of fibrosis. RESULTS: Of 20 cases, 5 had HVPG values corresponding to subclinical and clinical portal hypertension (≥6 and ≥10 mmHg, respectively) while 15 had normal HVPG values (≤5 mmHg). SHAPE and HVPG correlated moderately (r = 0.45; P = .047). SHAPE showed a trend toward correlating with fibrosis (r = 0.42; P = .068), while HVPG did not (r = 0.18; P = .45). SHAPE could differentiate between mild (stage 0-1) and moderate to severe (stage 2-4) fibrosis (-10.4 ± 4.9 dB versus -5.4 ± 3.2 dB; P = .035), HVPG could not (3.0 ± 0.6 mmHg versus 4.8 ± 0.7 mmHg; P = .30). ROC curves showed a diagnostic accuracy for SHAPE of 80%, while HVPG reached 76%. CONCLUSION: Liver fibrosis staging in dialysis patients evaluated for portal hypertension appears to be more accurately predicted by SHAPE than by HVPG; albeit in a small sample size.


Assuntos
Hipertensão Portal , Insuficiência Renal Crônica , Humanos , Hipertensão Portal/complicações , Hipertensão Portal/diagnóstico por imagem , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Pressão na Veia Porta , Diálise Renal , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/terapia
8.
J Ultrasound Med ; 41(4): 835-843, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34101877

RESUMO

BACKGROUND: Small intestinal ischemia is a challenging diagnosis to make, even with the combination of imaging, laboratory analysis, and physical exam. This pilot study investigated the role of CEUS in evaluating small bowel wall vascularity in participants with suspected ischemia. METHODS: In this IRB-approved pilot study, CEUS using perflutren lipid microspheres (DEFINITY®; Lantheus Medical Imaging Inc., N. Billerica, MA) was performed on participants determined by the clinical surgical team to have concerns for small intestinal ischemia. CEUS interpretations were performed at both the bedside and later by a blinded radiologist and compared to clinical imaging, surgical findings, or long-term clinical outcomes. RESULTS: Fifteen CEUS examinations were performed on 14 participants. Five of the participants underwent exploratory laparotomy. Of these, one had small intestinal ischemia (without necrosis). Point of care CEUS demonstrated no evidence of bowel necrosis in any case, and delayed enhancement (indicative of intestinal ischemia) in three cases, resulting in a sensitivity of 100% (95% CI 2.5-100%) and specificity of 85.7% (95% CI 57.2-98.2%). CEUS correctly ruled out ischemia in 91.7% of cases with CT suspicion of small bowel obstruction and 60% of cases that underwent surgical intervention. Additionally, the rate of agreement between bedside interpretation and later radiologist read was high (93%). CONCLUSIONS: CEUS is uniquely positioned for evaluating the small intestine, because of its high temporal resolution and immediacy of results. Combined with multi-sectional imaging for focal areas of ischemia and/or clinical suspicion for pan ischemia, CEUS may be a useful rule out test for small intestinal ischemia.


Assuntos
Meios de Contraste , Intestino Delgado , Humanos , Intestino Delgado/diagnóstico por imagem , Isquemia/diagnóstico por imagem , Isquemia/etiologia , Projetos Piloto , Ultrassonografia/efeitos adversos
9.
Radiology ; 298(2): 450-457, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33320067

RESUMO

Background US contrast agents are gas-filled microbubbles (MBs) that can be locally destroyed by using external US. Among other bioeffects, US-triggered MB destruction, also known as UTMD, has been shown to sensitize solid tumors to radiation in preclinical models through localized insult to the vascular endothelial cells. Purpose To evaluate the safety and preliminary efficacy of combining US-triggered MB destruction and transarterial radioembolization (TARE) in participants with hepatocellular carcinoma (HCC). Materials and Methods In this pilot clinical trial, participants with HCC scheduled for sublobar TARE were randomized to undergo either TARE or TARE with US-triggered MB destruction 1-4 hours and approximately 1 and 2 weeks after TARE. Enrollment took place between July 2017 and February 2020. Safety of US-triggered MB destruction was evaluated by physiologic monitoring, changes in liver function tests, adverse events, and radiopharmaceutical distribution. Treatment efficacy was evaluated by using modified Response Evaluation Criteria in Solid Tumors (mRECIST) on cross-sectional images, time to required next treatment, transplant rates, and overall survival. Differences across mRECIST reads were compared by using a Mann-Whitney U test, and the difference in prevalence of tumor response was evaluated by Fisher exact test, whereas differences in time to required next treatment and overall survival curves were compared by using a log-rank (Mantel-Cox) test. Results Safety results from 28 participants (mean age, 70 years ± 10 [standard deviation]; 17 men) demonstrated no significant changes in temperature (P = .31), heart rate (P = .92), diastolic pressure (P = .31), or systolic pressure (P = .06) before and after US-triggered MB destruction. No changes in liver function tests between treatment arms were observed 1 month after TARE (P > .15). Preliminary efficacy results showed a greater prevalence of tumor response (14 of 15 [93%; 95% CI: 68, 100] vs five of 10 [50%; 95% CI: 19, 81]; P = .02) in participants who underwent both US-triggered MB destruction and TARE (P = .02). Conclusion The combination of US-triggered microbubble destruction and transarterial radioembolization is feasible with an excellent safety profile in this patient population and appears to result in improved hepatocellular carcinoma treatment response. © RSNA, 2020.


Assuntos
Braquiterapia/métodos , Carcinoma Hepatocelular/radioterapia , Meios de Contraste , Neoplasias Hepáticas/radioterapia , Microbolhas , Ultrassonografia/métodos , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Feminino , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Resultado do Tratamento
10.
Radiology ; 298(1): 104-111, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33201789

RESUMO

Background The current standard for assessing the severity of portal hypertension is the invasive acquisition of hepatic venous pressure gradient (HVPG). A noninvasive US-based technique called subharmonic-aided pressure estimation (SHAPE) could reduce risk and enable routine acquisition of these pressure estimates. Purpose To compare quantitative SHAPE to HVPG measurements to diagnose portal hypertension in participants undergoing a transjugular liver biopsy. Materials and Methods This was a prospective cross-sectional trial conducted at two hospitals between April 2015 and March 2019 (ClinicalTrials.gov identifier, NCT02489045). This trial enrolled participants who were scheduled for transjugular liver biopsy. After standard-of-care transjugular liver biopsy and HVPG pressure measurements, participants received an infusion of a US contrast agent and saline. During infusion, SHAPE data were collected from a portal vein and a hepatic vein, and the difference was compared with HVPG measurements. Correlations between data sets were determined by using the Pearson correlation coefficient, and statistical significance between groups was determined by using the Student t test. Receiver operating characteristic analysis was performed to determine the sensitivity and specificity of SHAPE. Results A total of 125 participants (mean age ± standard deviation, 59 years ± 12; 80 men) with complete data were included. Participants at increased risk for variceal hemorrhage (HVPG ≥12 mm Hg) had a higher mean SHAPE gradient compared with participants with lower HVPGs (0.79 dB ± 2.53 vs -4.95 dB ± 3.44; P < .001), which is equivalent to a sensitivity of 90% (13 of 14; 95% CI: 88, 94) and a specificity of 80% (79 of 99; 95% CI: 76, 84). The SHAPE gradient between the portal and hepatic veins was in good overall agreement with the HVPG measurements (r = 0.68). Conclusion Subharmonic-aided pressure estimation is an accurate noninvasive technique for detecting clinically significant portal hypertension. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Kiessling in this issue.


Assuntos
Meios de Contraste , Hipertensão Portal/diagnóstico por imagem , Aumento da Imagem/métodos , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Hipertensão Portal/fisiopatologia , Masculino , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem , Veia Porta/fisiopatologia , Estudos Prospectivos , Sensibilidade e Especificidade
11.
Dig Dis Sci ; 66(12): 4354-4360, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33392869

RESUMO

BACKGROUND: Portal hypertension is the underlying cause of most complications associated with cirrhosis, with the hepatic venous pressure gradient (HVPG) used for diagnosis and disease progression. Subharmonic imaging (SHI) is a contrast-specific imaging technique receiving at half the transmit frequency resulting in better tissue suppression. AIMS: To determine whether the presence of optimized SHI signals inside the hepatic vein can be used as a screening test for portal hypertension. METHODS: This prospective trial had 131 patients undergoing SHI examination of portal and hepatic veins using a modified Logiq 9 scanner (GE, Waukesha, WI). Images acquired after infusion of the ultrasound contrast agent Sonazoid (GE Healthcare, Oslo, Norway) were assessed for the presence of optimized SHI signals in the hepatic vein and compared to the HVPG values obtained as standard of care. RESULTS: Of 131 cases, 64 had increased HVPG values corresponding to subclinical (n = 31) and clinical (n = 33) portal hypertension (> 5 and > 10 mmHg, respectively), and 67 had normal HVPG values (< 5 mmHg). Two readers performed independent, binary qualitative assessments of the acquired digital clips. Reader one (experienced radiologist) achieved for the subclinical subgroup sensitivity of 98%, specificity of 88%, and ROC area of 0.93 and for the clinical subgroup sensitivity of 100% and specificity of 61%, with an ROC area of 0.74. Reader two (less experienced radiologist) achieved for the subclinical subgroup sensitivity of 77%, specificity of 76%, and ROC area of 0.76 and for the clinical subgroup sensitivity of 88% and specificity of 63%, with an ROC area of 0.70. Readers agreement was of 83% with kappa value of 0.66. CONCLUSION: The presence of optimized SHI signals inside the hepatic vein can be a qualitative screening test for portal hypertension, which could reduce the need for invasive diagnostic procedures.


Assuntos
Veias Hepáticas/diagnóstico por imagem , Hipertensão Portal/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Compostos Férricos , Humanos , Ferro , Masculino , Pessoa de Meia-Idade , Óxidos , Estudos Prospectivos , Adulto Jovem
12.
J Ultrasound Med ; 39(5): 977-985, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31769529

RESUMO

OBJECTIVES: This pilot study evaluated whether contrast-enhanced subharmonic imaging (SHI) could be used to characterize adnexal masses before surgical intervention. METHODS: Ten women (with 12 lesions) scheduled for surgery of an ovarian mass underwent an SHI examination of their adnexal region using a modified LOGIQ E9 scanner (GE Healthcare, Waukesha, WI) with an endocavitary transducer, in which digital clips were acquired by pulse destruction-replenishment SHI across the lesions. Time-intensity curves were created offline to quantitatively evaluate SHI parameters (fractional tumor perfusion, peak contrast intensity, time to peak contrast enhancement, and area under the time-intensity curve), which were compared to pathologic characterizations of the lesions. RESULTS: Of the 12 masses, 8 were benign, and 4 were malignant. A qualitative analysis of the SHI images by an experienced radiologist resulted in diagnostic accuracy of 70%, compared to 56% without contrast, whereas an inexperienced radiologist improved from 50% to 58% accuracy, demonstrating the benefit of SHI. A quantitative analysis of SHI parameters produced diagnostic accuracy as high as 81%. Peak contrast intensity was significantly greater in malignant than benign masses (mean ± SD, 0.109 ± 0.088 versus 0.046 ± 0.030 arbitrary units; P = .046). Malignant masses also showed significantly greater perfusion than benign masses (24.79% ± 25.34% versus 7.62% ± 6.50%; P = .045). When the radiologist reads were combined with the most predictive quantitative SHI parameter (percent perfusion), diagnostic accuracy improved to 84% for the experienced radiologist and 96% for the novice radiologist. CONCLUSIONS: Results indicate that SHI for presurgical characterization of adnexal masses may improve the determination of malignancy and diagnostic accuracy, albeit based on a small sample size.


Assuntos
Doenças dos Anexos/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Neoplasias Ovarianas/diagnóstico por imagem , Ultrassonografia/métodos , Anexos Uterinos/diagnóstico por imagem , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes
13.
J Ultrasound Med ; 39(10): 1947-1955, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32309889

RESUMO

OBJECTIVES: Vascular assessment of indeterminate renal masses (iRMs) remains a crucial element of diagnostic imaging, as the presence of blood flow within renal lesions suggests malignancy. We compared the utility of Superb Microvascular Imaging (SMI; Canon Medical Systems, Tustin, CA), a novel Doppler technique, to standard color Doppler imaging (CDI) and power Doppler imaging (PDI) for the detection of vascularity within iRMs. METHODS: Patients undergoing contrast-enhanced ultrasound (CEUS) evaluations for iRMs first underwent a renal ultrasound examination with the following modes: CDI, PDI, color Superb Microvascular Imaging (cSMI), and monochrome Superb Microvascular Imaging (mSMI), using an Aplio i800 scanner with an i8CX1 transducer (Canon Medical Systems). After image randomization, each mode was assessed for iRM vascularity by 4 blinded readers on a diagnostic confidence scale of 1 to 5 (5 = most confident). The results were compared to CEUS as the reference standard. RESULTS: Forty-one patients with 50 lesions met inclusion criteria. Relative to the other 3 modalities, mSMI had the highest sensitivity (63.3%), whereas cSMI had the highest specificity (62.1%). Both cSMI and mSMI also had the highest diagnostic accuracy (0.678 and 0.680, respectively; both P < 0.001) compared to CDI (0.568) and PDI (0.555). Although the reader-reported confidence interval of mSMI (mean ± SD, 3.6 ± 1.1) was significantly lower than CDI (4.1 ± 1.0) and PDI (4.0 ± 1.0; P < 0.001), the confidence level of cSMI (4.1 ± 0.9) was not (P > 0.173). CONCLUSIONS: Preliminary data suggest that SMI is a potentially useful modality in detecting microvasculature in iRMs compared to standard Doppler techniques. Future studies should aim to compare the efficacy of both SMI and CEUS and to assess the ability of SMI to characterize malignancy in iRMs.


Assuntos
Microvasos , Ultrassonografia Doppler , Humanos , Rim/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Sensibilidade e Especificidade , Ultrassonografia
14.
J Ultrasound Med ; 38(12): 3221-3228, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31124171

RESUMO

OBJECTIVES: Hypoxic cancer cells have been shown to be more resistant to radiation therapy than normoxic cells. Hence, this study investigated whether ultrasound (US)-induced rupture of oxygen-carrying microbubbles (MBs) would enhance the response of breast cancer metastases to radiation. METHODS: Nude mice (n = 15) received stereotactic injections of brain-seeking MDA-MB-231 breast cancer cells into the right hemisphere. Animals were randomly assigned into 1 of 5 treatment groups: no intervention, 10 Gy radiation using a small-animal radiation research platform, nitrogen-carrying MBs combined with US-mediated MB rupture immediately before 10 Gy radiation, oxygen-carrying MBs immediately before 10 Gy radiation, and oxygen-carrying MBs with US-mediated MB rupture immediately before 10 Gy radiation. Tumor progression was monitored with 3-dimensional US, and overall survival was noted. RESULTS: All groups except those treated with oxygen-carrying MB rupture and radiation had continued rapid tumor growth after treatment. Tumors treated with radiation alone showed a mean increase in volume ± SD of 337% ± 214% during the week after treatment. Tumors treated with oxygen-carrying MBs and radiation without MB rupture showed an increase in volume of 383% ± 226%. Tumors treated with radiation immediately after rupture of oxygen-carrying MBs showed an increase in volume of only 41% ± 1% (P = 0.045), and this group also showed a 1 week increase in survival time. CONCLUSIONS: Adding US-ruptured oxygen-carrying MBs to radiation therapy appears to delay tumor progression and improve survival in a murine model of metastatic breast cancer.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Neoplasias da Mama/patologia , Portadores de Fármacos , Microbolhas , Oxigênio/administração & dosagem , Animais , Modelos Animais de Doenças , Feminino , Camundongos , Camundongos Nus , Distribuição Aleatória , Ultrassonografia
15.
J Ultrasound Med ; 37(11): 2667-2679, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29708268

RESUMO

OBJECTIVES: The purpose of this study was to conduct a systematic review of the evidence of educational outcomes associated with teaching ultrasonography (US) to medical students. METHODS: A review of databases through 2016 was conducted for research studies that reported data on teaching US to medical students. Each title and abstract were reviewed by teams of 2 independent abstractors to determine whether the article would be ordered for full-text review and subsequently by 2 independent authors for inclusion. Data were abstracted with a form developed a priori by the authors. RESULTS: Ninety-five relevant unique articles were included (of 6936 identified in the databases). Survey data showed that students enjoyed the US courses and desired more US training. Of the studies that assessed US-related knowledge and skill, most of the results were either positive (16 of 25 for knowledge and 24 of 58 for skill) or lacked a control (8 of 25 for knowledge and 27 of 58 for skill). The limited evidence (14 of 95 studies) of the effect of US training on non-US knowledge and skill (eg, anatomy knowledge or physical examination skill) was mixed. CONCLUSIONS: There is ample evidence that students can learn US knowledge and skills and that they enjoy and want US training in medical school. The evidence for the effect of US on external outcomes is limited, and there is insufficient evidence to recommend it for this purpose at this time.


Assuntos
Competência Clínica , Currículo , Educação de Graduação em Medicina/métodos , Ultrassom/educação , Humanos , Ultrassonografia
17.
Acad Radiol ; 31(1): 199-211, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37507328

RESUMO

RATIONALE AND OBJECTIVES: Marked liver steatosis, steatohepatitis, and significant fibrosis are risk factors for unfavorable outcomes in non-alcoholic fatty liver disease (NAFLD). In this study, the diagnostic performance of attenuation coefficient (AC), liver stiffness (LS), and dispersion slope (DS) was evaluated separately and combined in the diagnosis of liver steatosis and fibrosis in NAFLD suspects using biopsy or magnetic resonance imaging (MRI) as a reference standard. MATERIALS AND METHODS: Seventy-four NAFLD suspects were prospectively imaged with an Aplio i800 ultrasound scanner (Canon Medical Systems, Tustin, CA). AC, LS, and DS measurements were obtained from the right liver lobe. RESULTS: Thirty-four patients underwent liver biopsy, and 40 had MRI. There were 32 patients (43%) with liver steatosis and fibrosis (S + F), 22 (30%) with steatosis (S), 5 (7%) with fibrosis (F), and 15 (20%) with normal liver (N). Mean ACs were significantly higher in steatotic livers (n = 54) than in non-steatotic livers (n = 20) (P < 0.0001). LS and DS were significantly higher in patients with liver fibrosis (n = 37) compared to non-fibrotic livers (n = 37) (P = 0.0004 and P = 0.0002, respectively). In detecting (S + F), the area under the receiver operating characteristic curve (AUROCC) was 0.87 for combined ultrasound parameters of LS and AC (negative predictive value [NPV]: 75%, positive predictive value [PPV]: 77%, P < 0.0001). In detecting patients with liver steatosis and fibrosis stage ≥2, LS had an AUROCC of 0.93 (NPV: 87%, PPV: 82%, P < 0.0001). In the biopsy group, 32% (11/34) were diagnosed with non-alcoholic steatohepatitis (NASH). DS values showed a significant difference among patients with (n = 23) or without (n = 11) hepatocellular ballooning (P = 0.02). AUROCC was 0.87 for combined ultrasound parameters of AC, LS, and DS with body mass index (BMI) in detecting NASH (NPV: 80%, PPV: 87%, P = 0.0006). CONCLUSION: AC and LS showed high diagnostic value in detecting liver steatosis and fibrosis, respectively. The combined AC and LS values further improved the diagnostic accuracy in detecting NAFLD and high-risk NAFLD patients.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/complicações , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Fibrose , Biópsia
18.
Ultrasound Med Biol ; 50(9): 1387-1394, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38876912

RESUMO

OBJECTIVE: Both microbubble ultrasound contrast agents and acoustic phase change droplets (APCD) have been explored in hepatocellular carcinoma (HCC). This work aimed to evaluate changes to the HCC microenvironment following either microbubble or APCD destruction in a syngeneic pre-clinical model. METHODS: Mouse RIL-175 HCC tumors were grown in the right flank of 64 immunocompetent mice. Pre-treatment, photoacoustic volumetric tumor oxygenation, and power Doppler measurements were obtained using a Vevo 3100 system (VisualSonics, Toronto, Canada). The experimental groups received a 0.1 mL bolus injection of either Definity ultrasound contrast agent (Lantheus Medical Imaging) or APCD fabricated by condensing Definity. Following injection, ultrasound destruction was performed using flash-replenishment sequences on a Sequoia with a 10L4 probe (Siemens) for the duration of enhancement. Tumor oxygenation and power Doppler measurements were then repeated immediately post-ultrasound treatment. Twenty-four hours post-treatment, animals were euthanized, and tumors were harvested and stained for CD31, Cleaved Caspase 3 and CD45. RESULTS: Imaging biomarkers demonstrated a significant reduction in percent vascularity following either microbubble or APCD destruction in the tumor microenvironment ( p < 0.022) but no significant changes in tumor oxygenation (p = 0.12). Similarly, immunohistochemistry data demonstrated a significant decrease in CD31 expression (p < 0.042) and an increase in apoptosis (p < 0.014) in tumors treated with destroyed microbubbles or APCD relative to controls. Finally, a significant increase in CD45 expression was observed in tumors treated with APCD (p = 0.046), indicating an increase in tumor immune response. CONCLUSION: Ultrasound-triggered destruction of both microbubbles and APCD reduces vascularity, increases apoptosis, and may also increase immune response in this HCC model.


Assuntos
Carcinoma Hepatocelular , Meios de Contraste , Neoplasias Hepáticas , Microbolhas , Microambiente Tumoral , Animais , Camundongos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Modelos Animais de Doenças , Fluorocarbonos
19.
Transl Androl Urol ; 13(2): 342-352, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38481874

RESUMO

Background and Objective: Erectile dysfunction (ED) is a common condition in men, and many patients refractory to conservative treatment may undergo penile prostheses (PPs) placement. The primary concern following PP implantation is device infection. Although antibiotic and hydrophilic coatings have reduced the incidence of inflatable PP (IPP) infections, there remains room for improvement. Optimization of PP outcomes requires a practical in vivo model to better understand mechanisms of infection and to test new infection control strategies. We aimed to describe a new rabbit model which contains a functional IPP and review previously reported animal PP models. Methods: An IPP was placed into rabbit flanks and cycled for functionality testing. Rabbits were evaluated for signs of pain and distress over 14 days. Separately, narrative review methodology was utilized to search the PubMed and Scopus databases for all publications through March 21, 2023, which studied PP within an in vivo setting. Three independent reviewers ultimately selected 12 papers from 1992-2021 for inclusion. Key Content and Findings: Several animal studies highlighted the initial functionality or feasibility of devices for ED before their introduction in the clinical setting. There are several subsequent studies aimed at optimizing the type of antibiotic use or coating material using segments of PP material in an in vivo setting. However, the literature lacks a contemporary animal model containing a functional IPP. Our novel rabbit model offers a safe, practical way to implant a functioning IPP and investigate new perioperative infection prevention and treatment strategies before trials in the clinical setting. Conclusions: Animal models have played a key role in testing medical devices, including PPs, prior to their clinical introduction. Our review uncovered no modern animal studies involving placement of a functional PP. A new animal model can facilitate study of evolving microorganism profiles, novel methods to enhance antibiotic delivery, and proposed treatment options.

20.
Acad Radiol ; 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38908918

RESUMO

RATIONALE AND OBJECTIVE: Hepatocellular carcinoma (HCC) locoregional treatment response is commonly evaluated using the Modified Response Evaluation Criteria in Solid Tumors and the American College of Radiology (ACR) Liver Reporting and Data System (LI-RADS) Treatment Response Assessment (TRA) for MRI/CT. This study aims to evaluate the diagnostic performance of the new ACR contrast-enhanced ultrasound (CEUS) Nonradiation TRA LI-RADS v2024 in HCC treated with transarterial chemoembolization (TACE). MATERIALS AND METHODS: This retrospective observational study included 87 patients treated with TACE from a previously reported cohort. At 15- and 30-days post-treatment, 68 and 72 HCC lesions were evaluated. Three blinded radiologists with different levels of CEUS experience interpreted the images independently. According to CEUS Nonradiation TRA LI-RADSv2024, both intralesional and perilesional tumor viability were evaluated and final TRA categories were as follows: TR-Nonviable, TR-Equivocal, and TR-Viable. The reference standard used was a composite of histology and imaging. RESULTS: 140 HCC lesions were analyzed. At 15 days post-treatment, the sensitivity (SN), specificity (SP), positive predictive value (PPV), negative predictive value (NPV), and accuracy of TR-Viable classification ranged from 72.5-94.3%, 72.2-86.4%, 86.8-91.4%, 65.6-86.7%, 76.9-86.8%, respectively. At 30 days post-treatment, the SN, PPV, and NPV of TR-Viable classification decreased, ranging from 65.9-84.2%, 85.7-90.6%, and 59.5-73.9%, respectively, while the SP increased, ranging from 80.0-88.0%. Kappa values ranged from 0.557-0.730, indicating moderate to substantial agreement. CONCLUSION: CEUS Nonradiation TRA LI-RADS is a reliable tool for the detection of viable tumors in lesions treated with TACE and demonstrates reproducibility across readers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA