Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Med ; 91(4): 1449-1463, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38044790

RESUMO

PURPOSE: Time-lapse MRI enables tracking of single iron-labeled cells. Yet, due to temporal blurring, only slowly moving cells can be resolved. To study faster cells for example during inflammatory processes, accelerated acquisition is needed. METHODS: A rotating phantom system was developed to quantitatively measure the current maximum detectable speed of cells in time-lapse MRI. For accelerated cell tracking, an interleaved radial acquisition scheme was applied to phantom and murine brain in vivo time-lapse MRI experiments at 9.4 T. Detection of iron-labeled cells was evaluated in fully sampled and undersampled reconstructions with and without compressed sensing. RESULTS: The rotating phantom system enabled ultra-slow rotation of phantoms and a velocity detection limit of full-brain Cartesian time-lapse MRI of up to 172 µm/min was determined. Both phantom and in vivo measurements showed that single cells can be followed dynamically using radial time-lapse MRI. Higher temporal resolution of undersampled reconstructions reduced geometric distortion, the velocity detection limit was increased to 1.1 mm/min in vitro, and previously hidden fast-moving cells were recovered. In the mouse brain after in vivo labeling, a total of 42 ± 4 cells were counted in fully sampled, but only 7 ± 1 in undersampled images due to streaking artifacts. Using compressed sensing 33 ± 4 cells were detected. CONCLUSION: Interleaved radial time-lapse MRI permits retrospective reconstruction of both fully sampled and accelerated images, enables single cell tracking at higher temporal resolution and recovers cells hidden before due to blurring. The velocity detection limit as determined with the rotating phantom system increased two- to three-fold compared to previous results.


Assuntos
Rastreamento de Células , Imageamento por Ressonância Magnética , Animais , Camundongos , Estudos Retrospectivos , Limite de Detecção , Imagem com Lapso de Tempo , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ferro , Imageamento Tridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos
2.
Magn Reson Med ; 90(6): 2443-2453, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37466029

RESUMO

PURPOSE: Temporal resolution of time-lapse MRI to track individual iron-labeled cells is limited by the required data-acquisition time to fill k-space and to reach sufficient SNR. Although motion of slowly patrolling monocytes can be resolved, detection of fast-moving immune cells requires improved acquisition and reconstruction strategies. THEORY AND METHODS: For accelerated MRI cell tracking, a Cartesian sampling scheme was designed, in which the fully sampled and undersampled k-space data for different acceleration factors were acquired simultaneously, and multiple undersampling ratios could be chosen retrospectively. Compressed-sensing reconstruction was applied using dictionary learning and low-rank constraints. Detection of iron-labeled monocytes was evaluated with simulations, rotating phantom experiments and in vivo mouse brain measurements at 9.4 T. RESULTS: Fully sampled and 2.4-times and 4.8-times accelerated images were reconstructed and had sufficient contrast-to-noise ratio (CNR) for single cells to be resolved and followed dynamically. The phantom experiments showed an improvement in CNR of 6.1% per µm/s in the 4.8-times undersampled images. Geometric distortion of cells caused by motion was visibly reduced in the accelerated images, which enabled detection of moving cells with velocities of up to 7.0 µm/s. In vivo, additional cells were resolved in the accelerated images due to the improved temporal resolution. CONCLUSION: The easy-to-implement flexible Cartesian sampling scheme with compressed-sensing reconstruction permits simultaneous acquisition of both fully sampled and high temporal resolution images. The CNR of moving cells is effectively improved, enabling the recovery of high velocity cells with sufficient contrast at virtually no cost.


Assuntos
Rastreamento de Células , Imageamento por Ressonância Magnética , Animais , Camundongos , Estudos Retrospectivos , Imagem com Lapso de Tempo , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Processamento de Imagem Assistida por Computador/métodos
3.
Magn Reson Med ; 85(6): 3085-3095, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33462838

RESUMO

PURPOSE: To assess the feasibility of measuring tubular and vascular signal fractions in the human kidney using nonnegative least-square (NNLS) analysis of intravoxel incoherent motion data collected in healthy volunteers and patients with renal pathologies. METHODS: MR imaging was performed at 3 Tesla in 12 healthy subjects and 3 patients with various kidney pathologies (fibrotic kidney disease, failed renal graft, and renal masses). Relative signal fractions f and mean diffusivities of the diffusion components in the cortex, medulla, and renal lesions were obtained using the regularized NNLS fitting of the intravoxel incoherent motion data. Test-retest repeatability of the NNLS approach was tested in 5 volunteers scanned twice. RESULTS: In the healthy kidneys, the NNLS method yielded diffusion spectra with 3 distinguishable components that may be linked to the slow tissue water diffusion, intermediate tubular and vascular flow, and fast blood flow in larger vessels with the relative signal fractions, fslow , finterm and ffast , respectively. In the pathological kidneys, the diffusion spectra varied substantially from those acquired in the healthy kidneys. Overall, the renal cyst showed substantially higher finterm and lower fslow , whereas the fibrotic kidney, failed renal graft, and renal cell carcinoma demonstrated the opposite trend. CONCLUSION: NNLS-based intravoxel incoherent motion could potentially become a valuable tool in assessing changes in tubular and vascular volume fractions under pathophysiological conditions.


Assuntos
Imagem de Difusão por Ressonância Magnética , Rim , Voluntários Saudáveis , Humanos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Movimento (Física) , Reprodutibilidade dos Testes
4.
J Immunother Cancer ; 11(3)2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36918222

RESUMO

BACKGROUND: The inflammatory tumor microenvironment (TME) is formed by various immune cells, being closely associated with tumorigenesis. Especially, the interaction between tumor-infiltrating T-cells and macrophages has a crucial impact on tumor progression and metastatic spread. The purpose of this study was to investigate whether oscillating-gradient diffusion-weighted MRI (OGSE-DWI) enables a cell size-based discrimination between different cell populations of the TME. METHODS: Sine-shaped OGSE-DWI was combined with the Imaging Microstructural Parameters Using Limited Spectrally Edited Diffusion (IMPULSED) approach to measure microscale diffusion distances, here relating to cell sizes. The accuracy of IMPULSED-derived cell radii was evaluated using in vitro spheroid models, consisting of either pure cancer cells, macrophages, or T-cells. Subsequently, in vivo experiments aimed to assess changes within the TME and its specific immune cell composition in syngeneic murine breast cancer models with divergent degrees of malignancy (4T1, 67NR) during tumor progression, clodronate liposome-mediated depletion of macrophages, and immune checkpoint inhibitor (ICI) treatment. Ex vivo analysis of IMPULSED-derived cell radii was conducted by immunohistochemical wheat germ agglutinin staining of cell membranes, while intratumoral immune cell composition was analyzed by CD3 and F4/80 co-staining. RESULTS: OGSE-DWI detected mean cell radii of 8.8±1.3 µm for 4T1, 8.2±1.4 µm for 67NR, 13.0±1.7 for macrophage, and 3.8±1.8 µm for T-cell spheroids. While T-cell infiltration during progression of 4T1 tumors was observed by decreasing mean cell radii from 9.7±1.0 to 5.0±1.5 µm, increasing amount of intratumoral macrophages during progression of 67NR tumors resulted in increasing mean cell radii from 8.9±1.2 to 12.5±1.1 µm. After macrophage depletion, mean cell radii decreased from 6.3±1.7 to 4.4±0.5 µm. T-cell infiltration after ICI treatment was captured by decreasing mean cell radii in both tumor models, with more pronounced effects in the 67NR tumor model. CONCLUSIONS: OGSE-DWI provides a versatile tool for non-invasive profiling of the inflammatory TME by assessing the dominating cell type T-cells or macrophages.


Assuntos
Neoplasias , Microambiente Tumoral , Humanos , Camundongos , Animais , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Linfócitos T , Macrófagos
5.
EBioMedicine ; 73: 103670, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34742131

RESUMO

BACKGROUND: Immune cells show distinct motion patterns that change upon inflammatory stimuli. Monocytes patrol the vasculature to screen for pathogens, thereby exerting an early task of innate immunity. Here, we aimed to non-invasively analyse single patrolling monocyte behaviour upon inflammatory stimuli. METHODS: We used time-lapse Magnetic Resonance Imaging (MRI) of the murine brain to dynamically track single patrolling monocytes within the circulation distant to the actual site of inflammation in different inflammatory conditions, ranging from a subcutaneous pellet model to severe peritonitis and bacteraemia. FINDINGS: Single patrolling immune cells with a velocity of <1 µm/s could be detected and followed dynamically using time-lapse MRI. We show, that due to local and systemic stimuli the slowly patrolling behaviour of monocytes is altered systemically and differs with type, duration and strength of the underlying stimulus. INTERPRETATION: Using time-lapse MRI, it is now possible to investigate the behaviour of single circulating monocytes over the course of the systemic immune response. Monocyte patrolling behaviour is altered systemically even before the onset of clinical symptoms distant to and depending on the underlying inflammatory stimulus. FUNDING: This study was supported by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) - CRC 1009 - 194468054 to AZ, CF and - CRC 1450 - 431460824 to MM, SN, HB, AZ, CF, the Joachim Herz Foundation (Add-on Fellowship for Interdisciplinary Life Sciences to MM), the Interdisciplinary Centre for Clinical Research (IZKF, core unit PIX) and the Medical Faculty of the University of Muenster (MEDK fellowship to FF and IF).


Assuntos
Movimento Celular , Rastreamento de Células/métodos , Sistema Imunitário/citologia , Imageamento por Ressonância Magnética/métodos , Análise de Célula Única , Imagem com Lapso de Tempo , Animais , Biomassa , Movimento Celular/genética , Modelos Animais de Doenças , Feminino , Sistema Imunitário/imunologia , Sistema Imunitário/metabolismo , Inflamação/etiologia , Inflamação/metabolismo , Inflamação/patologia , Camundongos , Monócitos , Análise de Célula Única/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA