Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Am Coll Cardiol ; 32(2): 427-31, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9708471

RESUMO

OBJECTIVES: We used color Doppler flow mapping to determine whether vena contracta width (VCW) is a load-independent measure of the severity of mitral regurgitation. BACKGROUND: VCW has been proposed to be a relatively load-independent measure of mitral regurgitation severity in flow models using a fixed orifice. However, in patients with mitral regurgitation, VCW may not be load independent because of a dynamic regurgitant orifice. METHODS: VCW, effective regurgitant orifice area and regurgitant volume were measured by quantitative Doppler mapping in 31 patients with chronic mitral regurgitation at baseline and during nitroprusside infusion. Patients with rheumatic heart disease, annular calcification or endocarditis were considered to have a fixed regurgitant orifice, whereas patients with mitral valve prolapse, dilated cardiomyopathy or ischemia were considered to have a dynamic regurgitant orifice. RESULTS: Systolic blood pressure (148 +/- 27 to 115 +/- 25 mm Hg) and end-systolic wall stress (121 +/- 50 to 89 +/- 36) decreased with nitroprusside (p < 0.05). Although nitroprusside did not significantly change mean values for VCW (0.5 +/- 0.2 to 0.5 +/- 0.2 cm), regurgitant volume (69 +/- 47 to 69 +/- 56 ml) or effective regurgitant orifice area (0.5 +/- 0.4 to 0.5 +/- 0.6 cm2), individual patients exhibited marked directional variability. Specifically, VCW decreased in 16 patients (improved mitral regurgitation), remained unchanged in 7 patients and increased in 8 patients (worsened mitral regurgitation) with nitroprusside. Also, the VCW response to nitroprusside was concordant with changes in effective regurgitant orifice area and regurgitant volume, and was not different between dynamic and fixed orifice groups. CONCLUSIONS: Contrary to the results from in vitro studies, VCW is not load independent in patients with mitral regurgitation caused by dynamic changes in the regurgitant orifice. The origin of mitral regurgitation does not predict accurately whether the regurgitant orifice is fixed or dynamic. Finally, short-term vasodilation with nitroprusside may significantly worsen the severity of mitral regurgitation in some patients.


Assuntos
Volume Cardíaco/fisiologia , Insuficiência da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Adulto , Idoso , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/fisiologia , Calcinose/complicações , Cardiomiopatia Dilatada/complicações , Doença Crônica , Ecocardiografia Doppler em Cores , Endocardite/complicações , Feminino , Previsões , Doenças das Valvas Cardíacas/complicações , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/efeitos dos fármacos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Prolapso da Valva Mitral/complicações , Contração Miocárdica/fisiologia , Isquemia Miocárdica/complicações , Nitroprussiato/administração & dosagem , Cardiopatia Reumática/complicações , Vasodilatadores/administração & dosagem
2.
J Am Coll Cardiol ; 37(5): 1450-5, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11300460

RESUMO

OBJECTIVES: This study was performed to validate the accuracy of color flow vena contracta (VC) measurements of aortic regurgitation (AR) severity by comparing them to simultaneous intraoperative flow probe measurements of regurgitant fraction (RgF) and regurgitant volume (RgV). BACKGROUND: Color Doppler imaging of the vena contracta has emerged as a simple and reliable measure of the severity of valvular regurgitation. This study evaluated the accuracy of VC imaging of AR by transesophageal echocardiography (TEE). METHODS: A transit-time flow probe was placed on the ascending aorta during cardiac surgery in 24 patients with AR. The flow probe was used to measure RgF and RgV simultaneously during VC imaging by TEE. Flow probe and VC imaging were interpreted separately and in blinded fashion. RESULTS: A good correlation was found between VC width and RgF (r = 0.85) and RgV (r = 0.79). All six patients with VC width >6 mm had a RgF >0.50. All 18 patients with VC width <5 mm had a RgF <0.50. Vena contracta area also correlated well with both RgF (r = 0.81) and RgV (r = 0.84). All six patients with VC area >7.5 mm2 had a RgF >0.50, and all 18 patients with a VC area <7.5 mm2 had a RgF <0.50. In a subset of nine patients who underwent afterload manipulation to increase diastolic blood pressure, RgV increased significantly (34 +/- 26 ml to 41 +/- 27 ml, p = 0.042) while VC width remained unchanged (5.4 +/- 2.8 mm to 5.4 +/- 2.8 mm, p = 0.41). CONCLUSIONS: Vena contracta imaging by TEE color flow mapping is an accurate marker of AR severity. Vena contracta width and VC area correlate well with RgF and RgV obtained by intraoperative flow probe. Vena contracta width appears to be less afterload-dependent than RgV.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Volume Sanguíneo/fisiologia , Ecocardiografia Transesofagiana , Ultrassonografia Doppler em Cores , Adulto , Idoso , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
3.
Am J Cardiol ; 81(2): 253-5, 1998 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-9591918

RESUMO

A potential cardiovascular source of embolism was demonstrated by transesophageal echocardiography in 20 of 33 patients (61%) with acute limb ischemia. The percentage was higher in patients with large artery occlusions (9 of 11, 82%) than in those with small artery occlusions (9 of 22, 41%) (p = 0.026).


Assuntos
Ecocardiografia Transesofagiana , Cardiopatias/diagnóstico por imagem , Isquemia/complicações , Perna (Membro)/irrigação sanguínea , Tromboembolia/diagnóstico por imagem , Doença Aguda , Adulto , Idoso , Angiografia Coronária , Feminino , Cardiopatias/complicações , Humanos , Perna (Membro)/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tromboembolia/etiologia , Ultrassonografia Doppler Dupla
4.
Am J Cardiol ; 82(9): 1149-51, A10, 1998 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-9817504

RESUMO

Segmental contractile reserve measured by dobutamine magnetic resonance imaging quantitatively predicts improvement in end-systolic wall thickness after revascularization. Segments with end-systolic wall thickness <7 mm at rest do not demonstrate contractile reserve or improve after revascularization.


Assuntos
Cardiotônicos , Doença das Coronárias/cirurgia , Dobutamina , Ventrículos do Coração/patologia , Imagem Cinética por Ressonância Magnética/métodos , Revascularização Miocárdica , Miocárdio/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
5.
Am J Cardiol ; 81(2): 175-9, 1998 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-9591901

RESUMO

Mitral regurgitation (MR) severity is routinely assessed by Doppler color flow mapping, which is subject to technical and hemodynamic variables. Vena contracta width may be less influenced by hemodynamic variables and has previously been shown to correlate with angiographic estimates of MR severity. This study was performed to compare mitral vena contracta width by multiplane transesophageal echocardiography (TEE) with simultaneous quantitative Doppler echocardiography in 35 patients with MR. The vena contracta width was measured at the narrowest portion of the MR jet as it emerged through the coaptation of the leaflets; it was identified in 97% of the patients. Vena contracta width correlated well with regurgitant volume (R2 = 0.81) and regurgitant orifice area (R2 = 0.81) by quantitative Doppler technique. A vena contracta width > or = 0.5 cm always predicted a regurgitant volume >60 ml and an effective regurgitant orifice area > or = 0.4 cm2 in all patients. A vena contracta width < or = 0.3 cm always predicted a regurgitant volume <45 ml and a regurgitant orifice area < or = 0.35 cm2. Thus, vena contracta width by multiplane TEE correlates well with mitral regurgitant volume and regurgitant orifice area by quantitative Doppler echocardiography and provides a simple method for the identification of patients with severe MR.


Assuntos
Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Insuficiência da Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/fisiopatologia , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Veias/diagnóstico por imagem
6.
Am J Cardiol ; 81(6): 792-5, 1998 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-9527098

RESUMO

We compared quantitative Doppler echocardiography and cine magnetic resonance imaging for calculation of regurgitant volume and regurgitant fraction in mitral regurgitation. A good correlation was present between the 2 methods with some scatter in patients with severe mitral regurgitation and high regurgitant volumes.


Assuntos
Ecocardiografia Doppler , Imageamento por Ressonância Magnética , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/patologia , Adulto , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Índice de Gravidade de Doença
7.
Am J Cardiol ; 76(12): 937-40, 1995 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-7484835

RESUMO

There are racial differences in the prevalence and pattern of left ventricular (LV) hypertrophy in hypertension. This study was performed to determine whether racial differences also exist in LV hypertrophy among chronic cocaine users. We studied 112 chronic cocaine abusers < 45 years old in whom normal blood pressures (< or = 140/90 mm Hg) were recorded 3 times daily for 3 weeks. LV wall thickness and mass were measured echocardiographically. Technically adequate studies were obtained in 79 blacks and 33 whites. Self-reported cocaine use was higher in whites than in blacks (688 +/- 516 vs 431 +/- 468 $/week, p = 0.03). There were no group differences in terms of duration of cocaine use, age, height, weight, blood pressure, LV dimensions, or left atrial size. However, posterior wall thickness (1.13 +/- 0.17 vs 1.03 +/- 0.14 cm, p = 0.0035) and LV mass index (113 +/- 25 vs 94 +/- 19 g/m2, p = 0.0001) were significantly greater in blacks. LV hypertrophy, defined as an M-mode LV mass index > or = 134 g/m2, was present in 24 blacks (30%) and 2 whites (6%) (p = 0.011). When defined as a posterior wall thickness > or = 1.2 cm and a 2-dimensional echocardiographic LV mass index > or = 105 g/m2, LV hypertrophy was present in 37 of 79 blacks (47%) and in 6 of 33 whites (18%) (p = 0.0086). Cocaine-related LV hypertrophy is more prevalent in black men than in white men.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
População Negra , Cocaína , Hipertrofia Ventricular Esquerda/epidemiologia , Transtornos Relacionados ao Uso de Substâncias/complicações , Adulto , Ecocardiografia , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/etiologia , Masculino , Prevalência , Texas/epidemiologia , População Branca
8.
Am J Cardiol ; 78(10): 1119-23, 1996 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-8914874

RESUMO

Currently available invasive and noninvasive techniques for the determination of left ventricular end-diastolic and end-systolic volumes, ejection fraction, and cardiac output are more time-consuming and potentially less accurate in patients with atrial fibrillation (AF) than in those with sinus rhythm. Although magnetic resonance imaging (MRI) can rapidly and accurately measure these variables in patients with sinus rhythm, its ability to do so in subjects with AF is not known. To determine if left ventricular volumes, ejection fraction, and cardiac output can be measured accurately in patients with AF using MRI, 26 subjects (13 women and 13 men, aged 15 to 76 years) in sinus rhythm (n = 13) or AF (n = 13) underwent MRI followed immediately by invasive measurements of these indexes. For those in AF, MRI measurements of left ventricular end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, and cardiac output correlated well with catheterization measurements (r = 0.90, 0.90, 0.95, 0.85, and 0.90, respectively). In addition, the mean difference between MRI and catheterization measurements was similar in subjects with AF and in those with sinus rhythm. Compared with standard invasive measurements, MRI provides an accurate noninvasive determination of left ventricular volumes, ejection fraction, and cardiac output in patients with AF.


Assuntos
Fibrilação Atrial/etiologia , Cateterismo Cardíaco , Cardiopatias/diagnóstico , Imagem Cinética por Ressonância Magnética , Adolescente , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Volume Cardíaco/fisiologia , Eletrocardiografia , Feminino , Cardiopatias/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ventriculografia com Radionuclídeos , Volume Sistólico/fisiologia
9.
Magn Reson Imaging Clin N Am ; 4(2): 287-305, 1996 May.
Artigo em Inglês | MEDLINE | ID: mdl-8724567

RESUMO

MR imaging cardiac quantitation is accurate, highly reproducible, and feasible using equipment available in most hospitals. For determination of myocardial mass, evaluation of RV function, and quantitative measurements of flow in the great vessels and peripheral vasculature, MR imaging is the reference method. Availability of methods for rapid scanning and analysis will lead to increased use of cardiac MR imaging in quantifying cardiac function.


Assuntos
Coração/anatomia & histologia , Imageamento por Ressonância Magnética , Coração/fisiologia , Doenças das Valvas Cardíacas/diagnóstico , Humanos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia
12.
Circulation ; 92(10): 2863-8, 1995 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-7586253

RESUMO

BACKGROUND: Dobutamine stress echocardiography (DSE) and myocardial contrast echocardiography (MCE) can predict recovery of left ventricular function after myocardial infarction. DSE also has been shown to predict left ventricular functional recovery after revascularization in chronic ischemic heart disease, whereas MCE has not been evaluated in such patients. This study was performed to compare DSE and MCE in the prediction of left ventricular functional recovery after revascularization in patients with chronic ischemic heart disease. METHODS AND RESULTS: MCE and DSE were performed in 35 patients with chronic coronary artery disease and significant wall motion abnormalities (mean ejection fraction, 0.36 +/- 0.09). Regional wall motion was scored by use of a 16-segment model wherein 1 = normal or hyperkinetic, 2 = hypokinetic, 3 = akinetic, and 4 = dyskinetic. Each segment was evaluated for contractile reserve by DSE and perfusion by MCE. Revascularization (coronary artery bypass graft [n = 13] and percutaneous transluminal coronary angioplasty [n = 10]) was successful in 23 patients. Follow-up echocardiograms were done to assess wall motion 30 to 60 days later. In 238 segments with resting wall motion abnormalities, perfusion was more likely to present than contractile reserve (97% versus 91%, P < .02). Revascularization resulted in functional recovery in 77 of 95 hypokinetic segments (81%) but only 18 of 57 akinetic segments (32%, P < .0001). DSE and MCE were not significantly different in predicting functional recovery of hypokinetic segments. In akinetic segments, DSE and MCE had similar sensitivities (89% versus 94%, respectively) and negative predictive values (93% and 97%, respectively) in predicting functional recovery. However, DSE had a higher specificity (92% versus 67%, P < .02) and positive predictive value (85% versus 55%, P < .02) than MCE in predicting functional recovery. CONCLUSIONS: Both contractile reserve by DSE and perfusion by MCE are predictive of functional recovery in hypokinetic segments after coronary revascularization in patients with chronic coronary revascularization in patients with chronic coronary artery disease. In akinetic segments, myocardial perfusion by MCE may exist in segments that do not recover contractile function after revascularization. Thus, contractile reserve during low-dose dobutamine infusion is a better predictor of functional recovery after revascularization in akinetic segments than perfusion.


Assuntos
Dobutamina , Ecocardiografia/métodos , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/terapia , Revascularização Miocárdica , Função Ventricular Esquerda/fisiologia , Angioplastia Coronária com Balão , Cateterismo Cardíaco , Estudos de Casos e Controles , Ponte de Artéria Coronária , Circulação Coronária/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Isquemia Miocárdica/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
13.
Circulation ; 95(3): 636-42, 1997 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-9024151

RESUMO

BACKGROUND: Although Doppler color flow mapping is widely used to assess the severity of mitral regurgitation (MR), a simple, accurate, and quantitative marker of MR by color flow mapping remains elusive. We hypothesized that vena contracta width by color flow mapping would accurately predict the severity of MR. METHODS AND RESULTS: We studied 80 patients with MR. Vena contracta width was measured in multiple views with zoom mode and nonstandard angulation to optimize its visualization. Flow volumes across the left ventricular outflow tract and mitral annulus were calculated by pulsed-Doppler technique to determine regurgitant volume. Effective regurgitant orifice area was calculated by dividing the regurgitant volume by the continuous-wave Doppler velocity-time integral of the MR jet. The cause of MR was ischemia in 24, dilated cardiomyopathy in 34 mitral valve prolapse in 12, endocarditis in 2, rheumatic disease in 2, mitral annular calcification in 1, and uncertain in 5. Regurgitant volumes ranged from 2 to 191 mL. Regurgitant orifice area ranged from 0.01 to 1.47 cm2. Single-plane vena contracta width from the parasternal long-axis view correlated well with regurgitant volume (r = .85, SEE = 20 mL) and regurgitant orifice area (r = .86, SEE = 0.15 cm2). Biplane vena contracta width from apical views correlated well with regurgitant volume (r = .85, SEE = 19 mL) and regurgitant orifice area (r = .88, SEE = 0.14 cm2). A biplane vena contracta width > or = 0.5 cm was always associated with a regurgitant volume > 60 mL and a regurgitant orifice area > 0.4 cm2. A biplane vena contracta width < or = 0.3 cm predicted a regurgitant volume < 60 mL and a regurgitant orifice area < 0.4 cm2 in 24 of 29 patients. No other parameter, including jet area, left atrial size, pulmonary flow reversal, or semiquantitative MR grade, correlated significantly with regurgitant volume or regurgitant orifice area in a multivariate analysis. CONCLUSIONS: Our results demonstrate that careful color flow mapping of the vena contracta of the MR jet provides a simple quantitative assessment of MR that correlates well with quantitative Doppler techniques.


Assuntos
Vasos Coronários/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Insuficiência da Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/fisiopatologia , Veias/diagnóstico por imagem
14.
Circulation ; 93(8): 1502-8, 1996 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-8608617

RESUMO

BACKGROUND: The noninvasive measurement of absolute epicardial coronary arterial flow and flow reserve would be useful in the evaluation of patients with coronary circulatory disorders. Phase-contrast magnetic resonance imaging (PC-MRI) has been used to measure coronary arterial flow in animals, but its accuracy in humans is unknown. METHODS AND RESULTS: Twelve subjects (7 men, 5 women: age 44 to 67 years) underwent PC-MRI measurements of flow in the left anterior descending coronary artery or one of its diagonal branches at rest and after administration of adenosine (140 microgram . kg(-1) . min (-1) IV). Immediately thereafter, intracoronary Doppler velocity (IDV) and flow measurements were made during cardiac catheterization at rest and after intravenous administration of adenosine. For the 12 patients, the correlation between MRI and invasive measurements of coronary arterial flow and coronary arterial flow reserve was excellent: coronary flow (MRI) (mL/min)= 0.85 x coronary flow (IDV) (mL/min)+17 (mL/min), r=.89, and coronary flow reserve (MRI) =0.79 x coronary velocity reserve (IDV) + 0.34, r=.89. For the range of coronary arterial flows (18 to 161 mL/min) measured by MRI, the limit of agreement between MRI and catheterization measurements of flow was -13+/-30 mL/min; for the range of coronary reserves (0.7 to 3.7) measured by MRI, the limit of agreement between the two techniques was 0.1+/-0.4. CONCLUSIONS: Cine velocity-encoded PC-MRI can noninvasively measure absolute coronary arterial flow in the left anterior descending artery in humans. PC-MRI can detect pharmacologically induced changes in coronary arterial flow and can reliably distinguish between those subjects with normal and abnormal coronary artery flow reserve.


Assuntos
Circulação Coronária , Doença das Coronárias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adenosina/farmacologia , Adulto , Idoso , Feminino , Humanos , Fluxometria por Laser-Doppler , Masculino , Pessoa de Meia-Idade , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA