Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Thorac Oncol ; 15(2): 274-287, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31655296

RESUMO

INTRODUCTION: We assessed the Aurora A kinase inhibitor, alisertib, plus paclitaxel (henceforth referred to as alisertib/paclitaxel) as second-line treatment for SCLC. METHODS: In this double-blind study, patients with relapsed or refractory SCLC were stratified by relapse type (sensitive versus resistant or refractory) and brain metastases and randomized 1:1 to alisertib/paclitaxel or placebo plus paclitaxel (henceforth referred to as placebo/paclitaxel) in 28-day cycles. The primary end point was progression-free survival (PFS). Associations of c-Myc expression in tumor tissue (prespecified) and genetic alterations in circulating tumor DNA (retrospective) with clinical outcome were evaluated. RESULTS: A total of 178 patients were enrolled (89 in each arm). The median PFS was 3.32 months with alisertib/paclitaxel versus 2.17 months with placebo/paclitaxel (hazard ratio [HR] = 0.77, 95% confidence limit [CI]: 0.557-1.067, p = 0.113 in the intent-to-treat population versus HR = 0.71, 95% CI: 0.509-0.985, p = 0.038 with corrected analysis applied). Among 140 patients with genetic alternations, patients with cell cycle regulator mutations (cyclin-dependent kinase 6 gene [CDK6], retinoblastoma-like 1 gene [RBL1], retinoblastoma-like 2 gene [RBL2], and retinoblastoma 1 gene [RB1]) had significantly improved PFS with alisertib/paclitaxel versus with placebo/paclitaxel (3.68 versus 1.80 months, respectively [HR = 0.395, 95% CI: 0.239-0.654, p = 0.0003]), and overall survival (7.20 versus 4.47 months, respectively [HR = 0.427, 95% CI: 0.259-0.704, p = 0.00085]). A subset of patients with c-Myc expression showed significantly improved PFS with alisertib/paclitaxel. The incidence of grade 3 or higher drug-related adverse events was 67% (58 patients) with alisertib/paclitaxel versus 22% (25 patients) with placebo/paclitaxel. Twelve patients (14%) versus 11 (12%) died on study, including four versus zero treatment-related deaths. CONCLUSIONS: Efficacy signals were seen with alisertib/paclitaxel in relapsed or refractory SCLC. c-Myc expression and mutations in cell cycle regulators may be potential predictive biomarkers of alisertib efficacy; further prospective validations are warranted.


Assuntos
Neoplasias Pulmonares , Paclitaxel , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Azepinas , Biomarcadores , Intervalo Livre de Doença , Método Duplo-Cego , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Recidiva Local de Neoplasia/tratamento farmacológico , Pirimidinas , Estudos Retrospectivos , Resultado do Tratamento
2.
Biotechnol J ; 9(3): 337-47, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24390851

RESUMO

Tissue engineering is rapidly progressing from a research-based discipline to clinical applications. Emerging technologies could be utilized to develop therapeutics for a wide range of diseases, but many are contingent on a cell scaffold that can produce proper tissue ultrastructure. The extracellular matrix, which a cell scaffold simulates, is not merely a foundation for tissue growth but a dynamic participant in cellular crosstalk and organ homeostasis. Cells change their growth rates, recruitment, and differentiation in response to the composition, modulus, and patterning of the substrate on which they reside. Cell scaffolds can regulate these factors through precision design, functionalization, and application. The ideal therapy would utilize highly specialized cell scaffolds to best mimic the tissue of interest. This paper discusses advantages and challenges of optimized cell scaffold design in the endoderm, mesoderm, and ectoderm for clinical applications in tracheal transplant, cardiac regeneration, and skin grafts, respectively.


Assuntos
Diferenciação Celular/genética , Matriz Extracelular/metabolismo , Engenharia Tecidual , Ectoderma/crescimento & desenvolvimento , Ectoderma/metabolismo , Endoderma/crescimento & desenvolvimento , Endoderma/metabolismo , Matriz Extracelular/genética , Humanos , Mesoderma/crescimento & desenvolvimento , Mesoderma/metabolismo , Alicerces Teciduais
3.
Biomol Detect Quantif ; 1(1): 8-22, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27920993

RESUMO

Digital PCR offers very high sensitivity compared to many other technologies for processing molecular detection assays. Herein, a process is outlined for determining the lower limit of detection (LoD) of two droplet-based digital PCR assays for point mutations of the epidermal growth factor receptor (EGFR) gene. Hydrolysis probe mutation-detection assays for EGFR p.L858R and p.T790M mutations were characterized in detail. Furthermore, sixteen additional cancer-related mutation assays were explored by the same approach. For the EGFR L8585R assay, the assay sensitivity is extremely good, and thus, the LoD is limited by the amount of amplifiable DNA that is analyzed. With 95% confidence limits, the LoD is one mutant in 180,000 wild-type molecules for the evaluation of 3.3 µg of genomic DNA, and detection of one mutant molecule in over 4 million wild-type molecules was achieved when 70 million copies of DNA were processed. The measured false-positive rate for the EGFR L8585R assay is one in 14 million, which indicates the theoretical LoD if an unlimited amount of DNA is evaluated. For the EFGR T790M assay, the LoD is one mutant in 13,000 for analysis of a 3.3 µg sample of genomic DNA, and the dPCR assay limit sensitivity approaches one mutant in 22,000 wild-type molecules.

4.
Sci Rep ; 4: 4466, 2014 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-24667734

RESUMO

Targeted delivery of drugs and sensors into cells is an attractive technology with both medical and scientific applications. Existing delivery vehicles are generally limited by the complexity of their design, dependence on active transport, and inability to function within cellular compartments. Here, we developed self-assembled nanofibrous hydrogel fibers using a biologically inert, low-molecular-weight amphiphile. Self-assembled nanofibrous hydrogels offer unique physical/mechanical properties and can easily be loaded with a diverse range of payloads. Unlike commercially available E. coli membrane particles covalently bound to the pH reporting dye pHrodo, pHrodo encapsulated in self-assembled hydrogel-fibers internalizes into macrophages at both physiologic (37°C) and sub-physiologic (4°C) temperatures through an energy-independent, passive process. Unlike dye alone or pHrodo complexed to E. coli, pHrodo-SAFs report pH in both the cytoplasm and phagosomes, as well the nucleus. This new class of materials should be useful for next-generation sensing of the intracellular milieu.


Assuntos
Materiais Biocompatíveis/química , Técnicas Biossensoriais , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Nanofibras/química , Materiais Biocompatíveis/administração & dosagem , Citoplasma/química , Sistemas de Liberação de Medicamentos , Escherichia coli/efeitos dos fármacos , Hidrogel de Polietilenoglicol-Dimetacrilato/administração & dosagem , Cinética , Nanofibras/administração & dosagem , Fagossomos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA