Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Toxicol In Vitro ; 49: 77-89, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28870540

RESUMO

Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. The objective of CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for eye irritation assessment that can lead to complete replacement of the in vivo Draize rabbit eye test (OECD TG 405). A set of 80 reference chemicals was tested with seven test methods, one method was the Slug Mucosal Irritation (SMI) test method. The method measures the amount of mucus produced (MP) during a single 1-hour contact with a 1% and 10% dilution of the chemical. Based on the total MP, a classification (Cat 1, Cat 2, or No Cat) is predicted. The SMI test method correctly identified 65.8% of the Cat 1 chemicals with a specificity of 90.5% (low over-prediction rate for in vivo Cat 2 and No Cat chemicals). Mispredictions were predominantly unidirectional towards lower classifications with 26.7% of the liquids and 40% of the solids being underpredicted. In general, the performance was better for liquids than for solids with respectively 76.5% vs 57.1% (Cat 1), 61.5% vs 50% (Cat 2), and 87.5% vs 85.7% (No Cat) being identified correctly.


Assuntos
Olho/efeitos dos fármacos , Gastrópodes , Irritantes/classificação , Irritantes/toxicidade , Mucosa/efeitos dos fármacos , Testes de Toxicidade/métodos , Animais
2.
Toxicol In Vitro ; 49: 6-10, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29598996

RESUMO

Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. In the past, several prospective and retrospective validation studies have taken place in the area of serious eye damage/eye irritation testing. Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. A very important aspect to ensure development of successful alternative test methods and/or strategies for serious eye damage/eye irritation testing is the selection of appropriate reference chemicals. A set of 80 reference chemicals was selected for the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project, in collaboration with Cosmetics Europe, from the Draize Reference Database published by Cosmetics Europe based on key criteria that were set in their paper (e.g. balanced by important driver of classification and physical state). The most important goals of the CON4EI project were to identify the performance of eight in vitro alternative tests in terms of driver of classification and to identify similarities/differences between the methods in order the build a successful testing strategy that can discriminate between all UN GHS categories. This paper provides background on selection of the test chemicals.

3.
Toxicol In Vitro ; 49: 11-20, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28625465

RESUMO

Assessment of ocular irritancy is an international regulatory requirement and a necessary step in the safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as a stand-alone assay. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed with the goal of assessing the reliability of eight in vitro/alternative test methods as well as establishing an optimal tiered-testing strategy. One of the in vitro assays selected was the validated SkinEthic™ Human Corneal Epithelium Eye Irritation Test method (SkinEthic™ HCE EIT). The SkinEthic™ HCE EIT has already demonstrated its capacity to correctly identify chemicals (both substances and mixtures) not requiring classification and labelling for eye irritation or serious eye damage (No Category). The goal of this study was to evaluate the performance of the SkinEthic™ HCE EIT test method in terms of the important in vivo drivers of classification. For the performance with respect to the drivers all in vivo Cat 1 and No Cat chemicals were 100% correctly identified. For Cat 2 chemicals the liquids and the solids had a sensitivity of 100% and 85.7%, respectively. For the SkinEthic™ HCE EIT test method, 100% concordance in predictions (No Cat versus No prediction can be made) between the two participating laboratories was obtained. The accuracy of the SkinEthic™ HCE EIT was 97.5% with 100% sensitivity and 96.9% specificity. The SkinEthic™ HCE EIT confirms its excellent results of the validation studies.


Assuntos
Epitélio Corneano/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade/métodos , Alternativas aos Testes com Animais , Humanos , Reprodutibilidade dos Testes
4.
Toxicol In Vitro ; 49: 21-33, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28697962

RESUMO

Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI project was to develop tiered testing strategies for eye irritation assessment. A set of 80 reference chemicals (38 liquids and 42 solids) was tested with eight different methods. Here, the results obtained with the EpiOcular™ Eye Irritation Test (EIT), adopted as OECD TG 492, are shown. The primary aim of this study was to evaluate of the performance of the test method to discriminate between chemicals not requiring classification for serious eye damage/eye irritancy (No Category) and chemicals requiring classification and labelling. In addition, the predictive capacity in terms of in vivo drivers of classification (i.e. corneal opacity, conjunctival redness and persistence at day 21) was investigated. EpiOcular™ EIT achieved a sensitivity of 97%, a specificity of 87% and accuracy of 95% and also confirmed its excellent reproducibility (100%) from the original validation. The assay was applicable to all chemical categories tested in this project and its performance was not limited to the particular driver of the classification. In addition to the existing prediction model for dichotomous categorization, a new prediction model for Cat 1 is suggested.


Assuntos
Olho/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade/métodos , Alternativas aos Testes com Animais , Opacidade da Córnea/induzido quimicamente , Humanos , Reprodutibilidade dos Testes
5.
Toxicol In Vitro ; 49: 99-115, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28964898

RESUMO

Assessment of acute eye irritation potential is part of the international regulatory requirements for safety testing of chemicals. In the last decades, many efforts have been made in the search for alternative methods to replace the regulatory in vivo Draize rabbit eye test (OECD TG 405). Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. The main objective of the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for serious eye damage and eye irritation assessment that can lead to complete replacement of OECD TG 405. A set of 80 reference chemicals (e.g. balanced by important driver of classification and physical state), was tested with seven test methods. Based on the results of this project, three different strategies were suggested. We have provided a standalone (EpiOcular ET-50), a two-tiered and three-tiered strategy, that can be used to distinguish between Cat 1 and Cat 2 chemicals and chemicals that do not require classification (No Cat). The two-tiered and three-tiered strategies use an RhCE test method (EpiOcular EIT or SkinEthic™ EIT) at the bottom (identification No Cat) in combination with the BCOP LLBO (two-tiered strategy) or BCOP OP-KIT and SMI (three-tiered strategy) at the top (identification Cat 1). For our proposed strategies, 71.1% - 82.9% Cat 1, 64.2% - 68.5% Cat 2 and ≥80% No Cat chemicals were correctly identified. Also, similar results were obtained for the Top-Down and Bottom-Up approach.


Assuntos
Olho/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade/métodos , Animais , Bovinos , Gastrópodes , Humanos
6.
Toxicol In Vitro ; 49: 90-98, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28941583

RESUMO

Assessment of ocular irritation is a regulatory requirement in safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as stand-alone assays. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed to assess the reliability of eight in vitro test methods and computational models as well as establishing an optimal tiered-testing strategy. For three computational models (Toxtree, and Case Ultra EYE_DRAIZE and EYE_IRR) performance parameters were calculated. Coverage ranged from 15 to 58%. Coverage was 2 to 3.4 times higher for liquids than for solids. The lowest number of false positives (5%) was reached with EYE_IRR; this model however also gave a high number of false negatives (46%). The lowest number of false negatives (25%) was seen with Toxtree; for liquids Toxtree predicted the lowest number of false negatives (11%), for solids EYE_DRAIZE did (17%). It can be concluded that the training sets should be enlarged with high quality data. The tested models are not yet sufficiently powerful for stand-alone evaluations, but that they can surely become of value in an integrated weight-of-evidence approach in hazard assessment.


Assuntos
Olho/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Modelos Biológicos , Animais , Simulação por Computador , Relação Quantitativa Estrutura-Atividade , Coelhos , Testes de Toxicidade
7.
Toxicol In Vitro ; 49: 65-76, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28801046

RESUMO

Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium was developed to assess the reliability of eight in vitro test methods and establish an optimal tiered-testing strategy. One assay selected was the Short Time Exposure (STE) assay. This assay measures the viability of SIRC rabbit corneal cells after 5min exposure to 5% and 0.05% solutions of test material, and is capable of categorizing of Category 1 and No Category chemicals. The accuracy of the STE test method to identify Cat 1 chemicals was 61.3% with 23.7% sensitivity and 95.2% specificity. If non-soluble chemicals and unqualified results were excluded, the performance to identify Cat 1 chemicals remained similar (accuracy 62.2% with 22.7% sensitivity and 100% specificity). The accuracy of the STE test method to identify No Cat chemicals was 72.5% with 66.2% sensitivity and 100% specificity. Excluding highly volatile chemicals, non-surfactant solids and non-qualified results resulted in an important improvement of the performance of the STE test method (accuracy 96.2% with 81.8% sensitivity and 100% specificity). Furthermore, it seems that solids are more difficult to test in the STE, 71.4% of the solids resulted in unqualified results (solubility issues and/or high variation between independent runs) whereas for liquids 13.2% of the results were not qualified, supporting the restriction of the test method regarding the testing of solids.


Assuntos
Córnea/citologia , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade/métodos , Animais , Sobrevivência Celular/efeitos dos fármacos , Coelhos
8.
Toxicol In Vitro ; 44: 44-48, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28595836

RESUMO

Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. In the past, several prospective and retrospective validation studies have taken place in the area of serious eye damage/eye irritation testing. Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. A very important aspect to ensure development of successful alternative test methods and/or strategies for serious eye damage/eye irritation testing is the selection of appropriate reference chemicals. A set of 80 reference chemicals was selected for the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project, in collaboration with Cosmetics Europe, from the Draize Reference Database published by Cosmetics Europe based on key criteria that were set in their paper (e.g. balanced by important driver of classification and physical state). The most important goals of the CON4EI project were to identify the performance of eight in vitro alternative tests in terms of driver of classification and to identify similarities/differences between the methods in order the build a successful testing strategy that can discriminate between all UN GHS categories. This paper provides background on selection of the test chemicals.


Assuntos
Alternativas aos Testes com Animais , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade , Animais , Bases de Dados Factuais , Olho/efeitos dos fármacos , Rotulagem de Produtos , Coelhos
9.
Toxicol In Vitro ; 27(8): 2175-83, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23999410

RESUMO

The aim of this study was to determine if the EpiDerm™ reconstructed human skin model (MatTek Corp.) could be an acceptable alternative to the ISO 10993-required rabbit skin irritation test for assessing medical device biocompatibility. Eleven medical device polymers were tested. Four extracts were prepared per polymer, two each with saline and sesame oil; half were spiked with two R-38 irritants, lactic acid for saline extracts and heptanoic acid for the sesame oil extracts. Tissue viability was assessed by MTT reduction and the proinflammatory response was assessed by IL-1α release. LOAELs of 2% for lactic acid in saline and 0.7% for heptanoic acid in sesame oil were determined. A cell viability reduction of >50% was indicative of skin irritation. Cells exposed to saline extracts spiked with 3.25% lactic acid had significantly reduced mean cell viabilities (12.6-17.2%). Cells exposed to sesame oil extracts spiked with 1.25% heptanoic acid also exhibited reduced mean cell viabilities (25.5%-41.7%). All spiked cells released substantial amounts of IL-1α (253.5-387.4pg/ml) signifying a proinflammatory response. These results indicate that the EpiDerm™ model may be a suitable in vitro replacement for the assessment of the irritation potential of medical device extracts.


Assuntos
Adesivos/química , Alternativas aos Testes com Animais , Misturas Complexas/toxicidade , Equipamentos e Provisões , Polímeros/química , Testes de Irritação da Pele , Sobrevivência Celular/efeitos dos fármacos , Dureza , Humanos , Técnicas In Vitro , Interleucina-1alfa/metabolismo , Óleo de Gergelim/química , Cloreto de Sódio/química
10.
Can Med Assoc J ; 96(5): 285, 1967 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-20328740
11.
Can Med Assoc J ; 97(1): 35, 1967 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-20328963
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA