Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Surg Innov ; 29(2): 292-294, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34369226

RESUMO

Data from animal models is now available to initiate assessment of human safety and feasibility of wide-angle three-dimensional intracardiac echocardiography (3D ICE) to guide point-of-care implantation of percutaneous left ventricular assist devices in critical care settings. Assessment of these combined new technologies could be best achieved within a surgical institution with pre-existing expertise in separate utilization of ICE and Impella.


Assuntos
COVID-19 , Coração Auxiliar , Procedimentos Cirúrgicos Torácicos , Animais , Ecocardiografia/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Resultado do Tratamento
2.
Sci Rep ; 14(1): 10122, 2024 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698055

RESUMO

Non-invasive neuromodulation of non-compressible internal organs has significant potential for internal organ bleeding and blood-shift in aero/space medicine. The present study aims to investigate the potential influences of the non-invasive transcutaneous electrical nerve stimulation (TENS) on multiple non-compressible internal organs' blood flow. Porcine animal model (n = 8) was randomized for a total of 48 neuromodulation sessions with two different TENS stimulation frequencies (80 Hz, 10 Hz) and a placebo stimulation. A combination of two different electrode configurations (Abdominal-only or Abdominal and hind limb) were also performed. Intraarterial blood flow measurements were taken during pre and post-stimulation periods at the left renal artery, common hepatic artery, and left coronary artery. Intracranial, and extracranial arterial blood flows were also assessed with digital subtraction angiography. TENS with abdominal-only electrode configurations at 10 Hz demonstrated significant reductions in average peak blood flow velocity (APV) of the common hepatic artery (p = 0.0233) and renal arteries (p = 0.0493). Arterial pressures (p = 0.0221) were also significantly lower when renal APV was reduced. The outcome of the present study emphasises the potential use of TENS in decreasing the blood flow of non-compressible internal organs when the correct combination of electrodes configuration and frequency is used.


Assuntos
Estimulação Elétrica Nervosa Transcutânea , Animais , Estimulação Elétrica Nervosa Transcutânea/métodos , Suínos , Artéria Renal/fisiologia , Velocidade do Fluxo Sanguíneo , Artéria Hepática/fisiologia , Abdome/irrigação sanguínea , Fluxo Sanguíneo Regional
3.
ACS Biomater Sci Eng ; 10(5): 2863-2879, 2024 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-38696332

RESUMO

The present work describes a preclinical trial (in silico, in vivo and in vitro) protocol to assess the biomechanical performance and osteogenic capability of 3D-printed polymeric scaffolds implants used to repair partial defects in a sheep mandible. The protocol spans multiple steps of the medical device development pipeline, including initial concept design of the scaffold implant, digital twin in silico finite element modeling, manufacturing of the device prototype, in vivo device implantation, and in vitro laboratory mechanical testing. First, a patient-specific one-body scaffold implant used for reconstructing a critical-sized defect along the lower border of the sheep mandible ramus was designed using on computed-tomographic (CT) imagery and computer-aided design software. Next, the biomechanical performance of the implant was predicted numerically by simulating physiological load conditions in a digital twin in silico finite element model of the sheep mandible. This allowed for possible redesigning of the implant prior to commencing in vivo experimentation. Then, two types of polymeric biomaterials were used to manufacture the mandibular scaffold implants: poly ether ether ketone (PEEK) and poly ether ketone (PEK) printed with fused deposition modeling (FDM) and selective laser sintering (SLS), respectively. Then, after being implanted for 13 weeks in vivo, the implant and surrounding bone tissue was harvested and microCT scanned to visualize and quantify neo-tissue formation in the porous space of the scaffold. Finally, the implant and local bone tissue was assessed by in vitro laboratory mechanical testing to quantify the osteointegration. The protocol consists of six component procedures: (i) scaffold design and finite element analysis to predict its biomechanical response, (ii) scaffold fabrication with FDM and SLS 3D printing, (iii) surface treatment of the scaffold with plasma immersion ion implantation (PIII) techniques, (iv) ovine mandibular implantation, (v) postoperative sheep recovery, euthanasia, and harvesting of the scaffold and surrounding host bone, microCT scanning, and (vi) in vitro laboratory mechanical tests of the harvested scaffolds. The results of microCT imagery and 3-point mechanical bend testing demonstrate that PIII-SLS-PEK is a promising biomaterial for the manufacturing of scaffold implants to enhance the bone-scaffold contact and bone ingrowth in porous scaffold implants. MicroCT images of the harvested implant and surrounding bone tissue showed encouraging new bone growth at the scaffold-bone interface and inside the porous network of the lattice structure of the SLS-PEK scaffolds.


Assuntos
Materiais Biocompatíveis , Mandíbula , Alicerces Teciduais , Animais , Ovinos , Mandíbula/cirurgia , Mandíbula/diagnóstico por imagem , Alicerces Teciduais/química , Impressão Tridimensional , Análise de Elementos Finitos , Osteogênese
4.
Bioengineering (Basel) ; 10(10)2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37892963

RESUMO

Autologous bone replacement remains the preferred treatment for segmental defects of the mandible; however, it cannot replicate complex facial geometry and causes donor site morbidity. Bone tissue engineering has the potential to overcome these limitations. Various commercially available calcium phosphate-based bone substitutes (Novabone®, BioOss®, and Zengro®) are commonly used in dentistry for small bone defects around teeth and implants. However, their role in ectopic bone formation, which can later be applied as vascularized graft in a bone defect, is yet to be explored. Here, we compare the above-mentioned bone substitutes with autologous bone with the aim of selecting one for future studies of segmental mandibular repair. Six female sheep, aged 7-8 years, were implanted with 40 mm long four-chambered polyether ether ketone (PEEK) bioreactors prepared using additive manufacturing followed by plasma immersion ion implantation (PIII) to improve hydrophilicity and bioactivity. Each bioreactor was wrapped with vascularized scapular periosteum and the chambers were filled with autologous bone graft, Novabone®, BioOss®, and Zengro®, respectively. The bioreactors were implanted within a subscapular muscle pocket for either 8 weeks (two sheep), 10 weeks (two sheep), or 12 weeks (two sheep), after which they were removed and assessed by microCT and routine histology. Moderate bone formation was observed in autologous bone grafts, while low bone formation was observed in the BioOss® and Zengro® chambers. No bone formation was observed in the Novabone® chambers. Although the BioOss® and Zengro® chambers contained relatively small amounts of bone, endochondral ossification and retained hydroxyapatite suggest their potential in new bone formation in an ectopic site if a consistent supply of progenitor cells and/or growth factors can be ensured over a longer duration.

5.
Cells ; 12(13)2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-37443758

RESUMO

Periosteum is a highly vascularized membrane lining the surface of bones. It plays essential roles in bone repair following injury and reconstruction following invasive surgeries. To broaden the use of periosteum, including for augmenting in vitro bone engineering and/or in vivo bone repair, we have developed an ex vivo perfusion bioreactor system to maintain the cellular viability and metabolism of surgically resected periosteal flaps. Each specimen was placed in a 3D printed bioreactor connected to a peristaltic pump designed for the optimal flow rates of tissue perfusate. Nutrients and oxygen were perfused via the periosteal arteries to mimic physiological conditions. Biochemical assays and histological staining indicate component cell viability after perfusion for almost 4 weeks. Our work provides the proof-of-concept of ex vivo periosteum perfusion for long-term tissue preservation, paving the way for innovative bone engineering approaches that use autotransplanted periosteum to enhance in vivo bone repair.


Assuntos
Periósteo , Engenharia Tecidual , Ovinos , Animais , Periósteo/irrigação sanguínea , Periósteo/transplante , Retalhos Cirúrgicos , Perfusão , Reatores Biológicos
6.
Eur J Cardiothorac Surg ; 63(1)2022 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-36440952

RESUMO

OBJECTIVES: During mitral valve replacement, the anterior mitral leaflet is usually resected or modified. Anterior leaflet splitting seems the least disruptive modification. Reattachment of the modified leaflet to the annulus reduces the annulopapillary distance. The goal of this study was to quantify the acute effects on left ventricular function of splitting the anterior mitral leaflet and shortening the annulopapillary distance. METHODS: In 6 adult sheep, a wire was placed around the anterior leaflet and exteriorized through the left ventricular wall to enable splitting the leaflet in the beating heart. Releasable snares to reduce annulopapillary distance were likewise positioned and exteriorized. A mechanical mitral prosthesis was inserted to prevent mitral incompetence during external manipulations of the native valve. Instantaneous changes in left ventricular function were recorded before and after shortening the annulopapillary distance, then before and after splitting the anterior leaflet. RESULTS: After splitting the anterior leaflet, preload recruitable stroke work, stroke work, stroke volume, cardiac output, left ventricular end systolic pressure and mean pressure were significantly decreased by 26%, 23%, 12%, 9%, 15% and 11%, respectively. Shortening the annulopapillary distance was associated with significant decreases in the end systolic pressure volume relationship, preload recruitable stroke work, stroke work and left ventricular end systolic pressure by 67%, 33%, 15% and 13%, respectively. Shortening the annulopapillary distance after splitting the leaflet had no significant effect. CONCLUSIONS: Splitting the anterior mitral leaflet acutely impaired left ventricular contractility and haemodynamics in an ovine model. Shortening the annulopapillary distance after leaflet splitting did not further impair left ventricular function.


Assuntos
Insuficiência da Valva Mitral , Valva Mitral , Ovinos , Animais , Valva Mitral/cirurgia , Função Ventricular Esquerda , Insuficiência da Valva Mitral/cirurgia , Volume Sistólico , Hemodinâmica
7.
J Cardiovasc Transl Res ; 15(6): 1455-1463, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35543833

RESUMO

The absence of an accepted gold standard to estimate volume status is an obstacle for optimal management of left ventricular assist devices (LVADs). The applicability of the analogue mean systemic filling pressure (Pmsa) as a surrogate of the mean circulatory pressure to estimate volume status for patients with LVADs has not been investigated. Variability of flows generated by the Impella CP, a temporary LVAD, should have no physiological impact on fluid status. This translational interventional ovine study demonstrated that Pmsa did not change with variable circulatory flows induced by a continuous flow LVAD (the average dynamic increase in Pmsa of 0.20 ± 0.95 mmHg from zero to maximal Impella flow was not significant (p = 0.68)), confirming applicability of the human Pmsa equation for an ovine LVAD model. The study opens new directions for future translational and human investigations of fluid management using Pmsa for patients with temporary LVADs.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Ovinos , Animais , Insuficiência Cardíaca/cirurgia
8.
Open Vet J ; 11(4): 747-754, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35070872

RESUMO

BACKGROUND: Ketamine-based total intravenous anaesthesia techniques are commonly used in equine practice for ponies requiring short procedures such as castration in field conditions. When a longer duration of recumbency than provided by the initial dose of anaesthetic agents is required, administration of supplementary 'top-up' doses of anaesthetic agents is required. Ideally, a single dose of anaesthetic agents would reliably achieve a longer duration of action whilst maintaining adequate anaesthetic, surgical and recovery qualities. AIM: This prospective, randomised and blinded study aimed to compare the UK-licensed induction dose of ketamine with an increased dose in ponies undergoing castration in field conditions. The hypothesis was that an increased dose would produce a longer duration of action without negatively affecting qualities of anaesthesia, surgical conditions and recovery. METHODS: Ponies were randomly allocated to receive ketamine at either 2.2 mg kg-1 (K2.2) or 3 mg kg-1 (K3) combined with diazepam 20 µg kg-1 following pre-anaesthetic medication with romifidine and butorphanol. Quality of anaesthesia, surgery and recovery were scored using simple descriptive scales (SDS) and timings of key events recorded. Top-up doses of ketamine 0.5 mg kg-1 were administered if anaesthesia was inadequate during surgery. Time of top-up doses and total ketamine doses were recorded. Data were analysed using Student t-tests or the Mann-Whitney U test (p < 0.05). RESULTS: Thirty-six ponies completed the study. Six ponies enrolled were excluded due to cryptorchidism or surgical complications that required deviation from the anaesthetic protocol. There were no differences in timing of events recorded, number of ponies requiring top-up ketamine, timing and frequency of top-ups or total ketamine dose. Scores for anaesthetic and recovery qualities, and surgical conditions were similar between groups. CONCLUSION: Both induction doses of ketamine provided a similar duration of action and provided conditions suitable to anaesthetise ponies undergoing castration.


Assuntos
Anestésicos , Ketamina , Animais , Masculino , Anestesia Geral/veterinária , Anestésicos/farmacologia , Cavalos , Ketamina/farmacologia , Orquiectomia/métodos , Orquiectomia/veterinária , Estudos Prospectivos
9.
JTCVS Open ; 7: 111-120, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36003711

RESUMO

Objectives: Transcatheter mitral valve prostheses are designed to capture the anterior leaflet and surgical techniques designed to fully preserve the subvalvular apparatus at prosthetic valve insertion both serve to shorten the anterior mitral leaflet height, thus effectively incorporating it into the anterior annulus. This study quantifies the acute effects of incorporating the anterior mitral leaflet into the annulus on left ventricular function. Methods: Fourteen adult sheep (weight, 48.7 ± 6.2 kg) underwent a mechanical mitral valve insertion on normothermic beating-heart cardiopulmonary bypass, with full retention of the native mitral valve but with placement of exteriorized releasable snares around the anterior mitral leaflet. Continuous measurements of left ventricular mechano-energetics were recorded throughout, alternating incorporating and releasing of the anterior mitral leaflet to the mitral annulus. Echocardiography confirmed the incorporation into the annulus and release. Results: The independent indices of left ventricular contractility (ie, end systolic pressure volume relationship and preload recruitable stroke work) were both significantly impaired when the anterior mitral leaflet was incorporated to the annulus and restored after release, as were the hemodynamic parameters: cardiac output, stroke volume, stroke work, and left ventricular pressure decreased by 15%, 17%, 23%, and 11%, respectively. Echocardiography demonstrated increased sphericity of the left ventricle during anterior mitral leaflet incorporation. Conclusions: Incorporating the anterior mitral leaflet to the anterior annulus adversely affected left ventricular contractility, caused distortion of the left ventricle in the form of increased sphericity, and impaired hemodynamic parameters in normal ovine hearts.

10.
JTCVS Open ; 8: 251-258, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36004084

RESUMO

Background: The anterior mitral leaflet (AML) contributes to left ventricular (LV) function but is normally excised at the time of a bioprosthetic valve insertion. This study aimed to investigate methods of safely retaining the AML at the time of mitral valve replacement. Methods: Five adult sheep (57 ± 3.8 kg) each underwent 3 insertions of a bioprosthetic mitral valve (asymmetric interstrut sectors) alternating the wide and narrow interstrut distance under the AML. Each insertion was performed on normothermic beating-heart cardiopulmonary bypass, with full retention of the native valve. After each valve insertion, continuous measurements of LV and aortic pressures were recorded with echocardiographic assessment of mitral valve function. If LV outflow tract obstruction (LVOTO) was not seen on the resumption of normal cardiac output, a bolus of adrenaline was given to precipitate it. Results: Thirteen of 15 valve insertions resulted in LVOTO caused by systolic anterior motion (SAM), independent of valve orientation. The wide interstrut distance subtending the AML was associated with a greater requirement for inotropic stress to precipitate an obstruction and was associated with late systolic rather than holosystolic obstruction. Conclusions: The predisposition to and nature of LVOTO due to SAM were associated with the bioprosthetic valve interstrut distance subtending the fully retained AML and may explain the survival differences in such patients. This model represents an effective method for research into prevention of LVOTO following mitral valve replacement with preservation of the native valve.

11.
Sci Rep ; 10(1): 17485, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-33060679

RESUMO

Impella CP is a percutaneously inserted left ventricular assist device indicated for temporary mechanical cardiac support during high risk percutaneous coronary interventions and for cardiogenic shock. The potential application of Impella has become particularly relevant during the current COVID-19 pandemic, for patients with acute severe heart failure complicating viral illness. Standard implantation of the Impella CP is performed under fluoroscopic guidance. Positioning of the Impella CP can be confirmed with transthoracic or transoesophageal echocardiography. We describe an alternative approach to guide intracardiac implantation of the Impella CP using two-dimensional and three-dimensional intracardiac echocardiography. This new technique can be useful in selected groups of patients when fluoroscopy, transthoracic and transoesophageal echocardiography is deemed inapplicable or limited for epidemiological or clinical reasons. Intracardiac three-dimensional echocardiography is a feasible alternative to the traditional techniques for implantation of an Impella CP device but careful consideration must be given to the potential limitations and complications of this technique.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiologia , Betacoronavirus/isolamento & purificação , COVID-19 , Infecções por Coronavirus/complicações , Infecções por Coronavirus/patologia , Infecções por Coronavirus/virologia , Modelos Animais de Doenças , Ecocardiografia , Feminino , Insuficiência Cardíaca/complicações , Imageamento Tridimensional , Pandemias , Pneumonia Viral/complicações , Pneumonia Viral/patologia , Pneumonia Viral/virologia , Próteses e Implantes , SARS-CoV-2 , Ovinos , Ultrassonografia Doppler
12.
PLoS One ; 15(8): e0238045, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32857803

RESUMO

The mean systemic filling pressure (MSFP) represents an interaction between intravascular volume and global cardiovascular compliance (GCC). Intravascular volume expansion using fluid resuscitation is the most frequent intervention in intensive care and emergency medicine for patients in shock and with haemodynamic compromise. The relationship between dynamic changes in MSFP, GCC and left ventricular compliance is unknown. We conducted prospective interventional pilot study following euthanasia in post cardiotomy adult sheep, investigating the relationships between changes in MSFP induced by rapid intravascular filling with fluids, global cardiovascular compliance and left ventricular compliance. This pilot investigation suggested a robust correlation between a gradual increase in the intravascular stressed volume from 0 to 40 ml/kg and the MSFP r = 0.708 95% CI 0.435 to 0.862, making feasible future prospective interventional studies. Based on the statistical modelling from the pilot results, we expect to identify a strong correlation of 0.71 ± 0.1 (95% CI) between the MSFP and the stressed intravascular volume in a future study.


Assuntos
Volume Sanguíneo , Hemodinâmica , Animais , Ponte Cardiopulmonar , Ecocardiografia , Feminino , Ventrículos do Coração/fisiopatologia , Modelos Animais , Projetos Piloto , Estudos Prospectivos , Ovinos , Estresse Fisiológico , Função Ventricular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA