Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Acta Neurochir (Wien) ; 165(8): 2153-2163, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37407854

RESUMO

BACKGROUND: Lumbar foraminal stenosis (LFS) is an important pathologic entity that causes lumbar radiculopathies. Unrecognized LFS may be associated with surgical failure, and LFS remains challenging to treat surgically. This retrospective cohort study aimed to evaluate the clinical outcomes and prognostic factors of decompressive foraminotomy performed using the biportal endoscopic paraspinal approach for LFS. METHODS: A total of 102 consecutive patients with single-level unilateral LFS who underwent biportal endoscopic paraspinal decompressive foraminotomy were included. We evaluated the Visual Analogue Scale (VAS) score and the Oswestry Disability Index (ODI) before and after surgery. Demographic, preoperative data, and radiologic parameters, including the coronal root angle (CRA), were investigated. The patients were divided into Group A (satisfaction group) and Group B (unsatisfaction group). Parameters were compared between these two groups to identify the factors influencing unsatisfactory outcomes. RESULTS: In Group A (78.8% of patients), VAS and ODI scores significantly improved after biportal endoscopic paraspinal decompressive foraminotomy (p < 0.001). However, Group B (21.2% of patients) showed higher incidences of stenosis at the lower lumbar level (p = 0.009), wide segmental lordosis (p = 0.021), and narrow ipsilateral CRA (p = 0.009). In the logistic regression analysis, lower lumbar level (OR = 13.82, 95% CI: 1.33-143.48, p = 0.028) and narrow ipsilateral CRA (OR = 0.92, 95% CI: 0.86-1.00, p = 0.047) were associated with unsatisfactory outcomes. CONCLUSIONS: Significant improvement in clinical outcomes was observed for a year after biportal endoscopic paraspinal decompressive foraminotomy. However, clinical outcomes were unsatisfactory in 21.2% of patients, and lower lumbar level and narrow ipsilateral CRA were independent risk factors for unsatisfactory outcomes.


Assuntos
Foraminotomia , Estenose Espinal , Humanos , Descompressão Cirúrgica/efeitos adversos , Estudos Retrospectivos , Constrição Patológica/cirurgia , Resultado do Tratamento , Estenose Espinal/diagnóstico por imagem , Estenose Espinal/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Endoscopia/efeitos adversos
2.
BMC Musculoskelet Disord ; 23(1): 1117, 2022 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-36544180

RESUMO

BACKGROUND: Obese patients have a higher risk of complications during spinal surgery than non-obese patients. To the best of our knowledge, no studies have examined the differences in clinical and radiological outcomes after biportal endoscopic lumbar discectomy (BELD) between obese and non-obese patients. The study evaluated the association between obesity and outcomes after BELD in patients with lumbar disc herniation. METHODS: This was a retrospective case-control study conducted from March 2017 to March 2021 at two hospitals with 360 patients who underwent BELD after showing no improvement with conservative treatment. Clinical and radiologic outcomes were retrospectively analyzed after BELD in the non-obese (body mass index [BMI] < 30 kg/m2) and obese (BMI ≥ 30 kg/m2) groups. Demographic data and surgery-related factors were compared between the two groups. Clinical outcomes were followed up for 12 months after surgery and analyzed for differences. RESULTS: A total of 211 patients were enrolled in this study, and through case-control matching, the data of 115 patients (29, obese group; 86, non-obese group) were analyzed. The two groups showed no significant differences in Oswestry Disability Index, European Quality of Life-5 Dimensions (EQ-5D), and visual analog scale scores measured immediately after BELD and 12 months after surgery. After surgery, back pain, radiating leg pain, and EQ-5D scores improved. However, there was no significant difference in improvement, residual herniated disc, hematoma, or recurrence between the groups. CONCLUSIONS: Obese patients who underwent BELD for lumbar disc herniation showed no significant difference in clinical and radiologic outcomes compared with non-obese patients.


Assuntos
Discotomia Percutânea , Deslocamento do Disco Intervertebral , Humanos , Estudos Retrospectivos , Estudos de Casos e Controles , Deslocamento do Disco Intervertebral/complicações , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/cirurgia , Qualidade de Vida , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Resultado do Tratamento , Endoscopia/métodos , Discotomia/efeitos adversos , Discotomia/métodos , Dor nas Costas/etiologia , Discotomia Percutânea/métodos
3.
IEEE Antennas Wirel Propag Lett ; 21(9): 1857-1861, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37020750

RESUMO

In this letter, we evaluate antenna designs for ultra-high frequency and field (UHF) human brain magnetic resonance imaging (MRI) at 10.5 tesla (T). Although MRI at such UHF is expected to provide major signal-to-noise gains, the frequency of interest, 447 MHz, presents us with challenges regarding improved B1 + efficiency, image homogeneity, specific absorption rate (SAR), and antenna element decoupling for array configurations. To address these challenges, we propose the use of both monopole and dipole antennas in a novel hybrid configuration, which we refer to as a mono-dipole hybrid antenna (MDH) array. Compared to an 8-channel dipole antenna array of the same dimensions, the 8-channel MDH array showed an improvement in decoupling between adjacent array channels, as well as ~18% higher B1 + and SAR efficiency near the central region of the phantom based on simulation and experiment. However, the performances of the MDH and dipole antenna arrays were overall similar when evaluating a human model in terms of peak B1 + efficiency, 10 g SAR, and SAR efficiency. Finally, the concept of an MDH array showed an advantage in improved decoupling, SAR, and B1 + near the superior region of the brain for human brain imaging.

4.
Magn Reson Med ; 86(6): 3292-3303, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34272898

RESUMO

PURPOSE: Investigating the designs and effects of high dielectric constant (HDC) materials in the shape of a conformal helmet on the enhancement of RF field and reduction of specific absorption rate at 10.5 T for human brain studies. METHODS: A continuous and a segmented four-piece HDC helmet fit to a human head inside an eight-channel fractionated-dipole array were constructed and studied with a phantom and a human head model using computer electromagnetic simulations. The simulated transmit efficiency and receive sensitivity were experimentally validated using a phantom with identical electric properties and helmet-coil configurations of the computer model. The temporal and spatial distributions of displacement currents on the HDC helmets were analyzed. RESULTS: Using the continuous HDC helmet, simulation results in the human head model demonstrated an average transmit efficiency enhancement of 66%. A propagating displacement current was induced on the continuous helmet, leading to an inhomogeneous RF field enhancement in the brain. Using the segmented four-piece helmet design to reduce this effect, an average 55% and 57% enhancement in the transmit efficiency and SNR was achieved in human head, respectively, along with 8% and 28% reductions in average and maximum local specific absorption rate. CONCLUSION: The HDC helmets enhanced the transmit efficiency and SNR of the dipole array coil in the human head at 10.5 T. The segmentation of the helmet to disrupt the continuity of circumscribing displacement currents in the helmet produced a more uniform distribution of the transmit field and lower specific absorption rate in the human head compared with the continuous helmet design.


Assuntos
Dispositivos de Proteção da Cabeça , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Ondas de Rádio
5.
Sensors (Basel) ; 21(21)2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34770558

RESUMO

For ultra-high field and frequency (UHF) magnetic resonance imaging (MRI), the associated short wavelengths in biological tissues leads to penetration and homogeneity issues at 10.5 tesla (T) and require antenna transmit arrays for efficiently generated 447 MHz B1+ fields (defined as the transmit radiofrequency (RF) magnetic field generated by RF coils). Previously, we evaluated a 16-channel combined loop + dipole antenna (LD) 10.5 T head array. While the LD array configuration did not achieve the desired B1+ efficiency, it showed an improvement of the specific absorption rate (SAR) efficiency compared to the separate 8-channel loop and separate 8-channel dipole antenna arrays at 10.5 T. Here we compare a 16-channel dipole antenna array with a 16-channel LD array of the same dimensions to evaluate B1+ efficiency, 10 g SAR, and SAR efficiency. The 16-channel dipole antenna array achieved a 24% increase in B1+ efficiency in the electromagnetic simulation and MR experiment compared to the LD array, as measured in the central region of a phantom. Based on the simulation results with a human model, we estimate that a 16-channel dipole antenna array for human brain imaging can increase B1+ efficiency by 15% with similar SAR efficiency compared to a 16-channel LD head array.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Humanos , Imagens de Fantasmas
6.
Sensors (Basel) ; 21(18)2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34577210

RESUMO

For human head magnetic resonance imaging at 10.5 tesla (T), we built an 8-channel transceiver dipole antenna array and evaluated the influence of coaxial feed cables. The influence of coaxial feed cables was evaluated in simulation and compared against a physically constructed array in terms of transmit magnetic field (B1+) and specific absorption rate (SAR) efficiency. A substantial drop (23.1% in simulation and 20.7% in experiment) in B1+ efficiency was observed with a tight coaxial feed cable setup. For the investigation of the feed location, the center-fed dipole antenna array was compared to two 8-channel end-fed arrays: monopole and sleeve antenna arrays. The simulation results with a phantom indicate that these arrays achieved ~24% higher SAR efficiency compared to the dipole antenna array. For a human head model, we observed 30.8% lower SAR efficiency with the 8-channel monopole antenna array compared to the phantom. Importantly, our simulation with the human model indicates that the sleeve antenna arrays can achieve 23.8% and 21% higher SAR efficiency compared to the dipole and monopole antenna arrays, respectively. Finally, we obtained high-resolution human cadaver images at 10.5 T with the 8-channel sleeve antenna array.


Assuntos
Cabeça , Imageamento por Ressonância Magnética , Simulação por Computador , Desenho de Equipamento , Cabeça/diagnóstico por imagem , Humanos , Imagens de Fantasmas
7.
J Emerg Nurs ; 47(3): 400-411, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33229000

RESUMO

INTRODUCTION: Trauma is a leading cause of death in South Korea. This study aimed to identify the factors associated with secondary traumatic stress of nurses working at regional trauma centers. METHODS: A survey-based cross-sectional design was utilized. Data were collected through a structured questionnaire consisting of 5 rating scales and demographic data. Data were analyzed via descriptive statistics, t test, analysis of variance, Pearson's correlation, and multiple regression. RESULTS: One hundred eighty-six nurses participated, and most (84.4%) reported moderate to severe secondary traumatic stress. Exposure to traumatic events averaged 34.33 (SD = 6.25) out of 65 points. Average problem-focused coping was 3.00 (SD = 0.37), emotion-focused coping was 2.57 (SD = 0.26), and dysfunctional coping was 2.17 (SD = 0.41) out of 4 points. Social support from family and friends averaged 5.85 (SD = 0.75), social support from coworkers was 5.78 (SD = 0.83), and social support from supervisors was 4.65 (SD = 1.18) out of 7 points. The factors affecting the respondents' secondary traumatic stress were type D personality (ß = 0.39, P < .001), dysfunctional coping (ß = 0.28, P < .001), problem-focused coping (ß = 0.19, P < .01), desire for job rotation (ß = 0.17, P < .01), and social support from supervisors (ß = -0.12, P = < .05). This regression model was statistically significant and the explanatory power was 46.7% (F = 33.47, P < .001, Adj R2 = 0.47). DISCUSSION: Along with a personal effort to engage in stress management programs, administrators, managers, and supervisors should prioritize developing practical strategies for reducing secondary traumatic stress of nurses.


Assuntos
Fadiga de Compaixão , Enfermeiras e Enfermeiros , Adaptação Psicológica , Estudos Transversais , Humanos , República da Coreia/epidemiologia , Apoio Social , Inquéritos e Questionários , Centros de Traumatologia
8.
J Biomed Inform ; 98: 103274, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31499185

RESUMO

Mental illnesses are highly heterogeneous with diagnoses based on symptoms that are generally qualitative, subjective, and documented in free text clinical notes rather than as structured data. Moreover, there exists significant variation in symptoms within diagnostic categories as well as substantial overlap in symptoms between diagnostic categories. These factors pose extra challenges for phenotyping patients with mental illness, a task that has proven challenging even for seemingly well characterized diseases. The ability to identify more homogeneous patient groups could both increase our ability to apply a precision medicine approach to psychiatric disorders and enable elucidation of underlying biological mechanism of pathology. We describe a novel approach to deep phenotyping in mental illness in which contextual term extraction is used to identify constellations of symptoms in a cohort of patients diagnosed with schizophrenia and related disorders. We applied topic modeling and dimensionality reduction to identify similar groups of patients and evaluate the resulting clusters through visualization and interrogation of clinically interpretable weighted features. Our findings show that patients diagnosed with schizophrenia may be meaningfully stratified using symptom-based clustering.


Assuntos
Informática Médica/métodos , Transtornos Mentais/diagnóstico , Esquizofrenia/diagnóstico , Avaliação de Sintomas/métodos , Adulto , Algoritmos , Análise por Conglomerados , Registros Eletrônicos de Saúde , Feminino , Humanos , Masculino , Transtornos Mentais/fisiopatologia , Pessoa de Meia-Idade , Processamento de Linguagem Natural , Fenótipo , Medicina de Precisão/métodos , Esquizofrenia/fisiopatologia , Processos Estocásticos
9.
NMR Biomed ; 31(1)2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29073724

RESUMO

In vivo 31 P magnetic resonance spectroscopy (MRS) provides a unique tool for the non-invasive study of brain energy metabolism and mitochondrial function. The assessment of bioenergetic impairment in different brain regions is essential to understand the pathophysiology and progression of human brain diseases. This article presents a simple and effective approach which allows the interleaved measurement of 31 P spectra and imaging from two distinct human brain regions of interest with dynamic B0 shimming capability. A transistor-transistor logic controller was employed to actively switch the single-channel X-nuclear radiofrequency (RF) transmitter-receiver between two 31 P RF surface coils, enabling the interleaved acquisition of two 31 P free induction decays (FIDs) from human occipital and frontal lobes within the same repetition time. Linear gradients were incorporated into the RF pulse sequence to perform the first-order dynamic shimming to further improve spectral resolution. The overall results demonstrate that the approach provides a cost-effective and time-efficient solution for reliable 31 P MRS measurement of cerebral phosphate metabolites and adenosine triphosphate (ATP) metabolic fluxes from two human brain regions with high detection sensitivity and spectral quality at 7 T. The same design concept can be extended to acquire multiple spectra from more than two brain regions or can be employed for other magnetic resonance applications beyond the 31 P spin.


Assuntos
Lobo Frontal/fisiologia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Lobo Occipital/fisiologia , Fósforo/química , Simulação por Computador , Humanos , Imageamento Tridimensional , Masculino , Adulto Jovem
10.
Magn Reson Med ; 75(6): 2566-72, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26198163

RESUMO

PURPOSE: To propose a new Extended Monopole antenna Array with individual Shields (EMAS) coil that improves the B1 field coverage and uniformity along the z-direction. METHODS: To increase the spatial coverage of Monopole antenna Array (MA) coil, each monopole antenna was shielded and extended in length. Performance of this new coil, which is referred to as EMAS coil, was compared with the original MA coil and an Extended Monopole antenna Array coil with no shield (EMA). For comparison, flip angle, signal-to-noise ratio (SNR), and receive sensitivity maps were measured at multiple regions of interest (ROIs) in the brain. RESULTS: The EMAS coil demonstrated substantially larger flip angle and receive sensitivity than the MA and EMA coils in the inferior aspect of the brain. In the brainstem ROI, for example, the flip angle in the EMAS coil was increased by 45.5% (or 60.0%) and the receive sensitivity was increased by 26.9% (or 14.9%), resulting in an SNR gain of 84.8% (or 76.3%) when compared with the MA coil (or EMA). CONCLUSION: The EMAS coil provided 25.7% (or 24.4%) more uniform B1+ field distribution compared with the MA (or EMA) coil in sagittal. The EMAS coil successfully extended the imaging volume in lower part of the brain. Magn Reson Med 75:2566-2572, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Humanos , Razão Sinal-Ruído
11.
Magn Reson Med ; 71(5): 1944-52, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23818275

RESUMO

PURPOSE: We have developed and evaluated a monopole antenna array that can increase sensitivity at the center of the brain for 7T MRI applications. METHODS: We have developed a monopole antenna array that has half the length of a conventional dipole antenna with eight channels for brain imaging with a 7T MRI. The eight-channel monopole antenna array and conventional eight-channel transceiver surface coil array were evaluated and compared in terms of transmit properties, specific absorption ratio (SAR), and sensitivity. The sensitivity maps were generated by dividing the SNR map by the flip angle distribution. RESULTS: A single surface coil provides asymmetric sensitivity resulting in reduced sensitivity at the center of the brain. In contrast, a single monopole antenna provides higher sensitivity at the center of the brain. Moreover, the monopole antenna array provides uniform sensitivity over the entire brain, and the sensitivity gain was 1.5 times higher at the center of the brain compared with the surface coil array. CONCLUSION: The monopole antenna array is a promising candidate for MRI applications, especially for brain imaging in a 7T MRI because it provides increased sensitivity at the center of the brain.


Assuntos
Encéfalo/anatomia & histologia , Análise de Falha de Equipamento/instrumentação , Aumento da Imagem/instrumentação , Magnetismo/instrumentação , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Clin J Pain ; 40(2): 92-98, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982510

RESUMO

OBJECTIVES: This study aimed to unidimensionally measure procedural pain at each percutaneous vertebroplasty (PVP) stage and evaluate the effectiveness of paravertebral nerve block (PVNB) in reducing procedural pain. METHODS: A retrospective study of prospectively collected data was conducted on 66 patients who underwent PVP for osteoporotic vertebral compression fractures. The patients were divided into 2 groups: group A (fluoroscopic-guided PVNB; 5 cm 3 of 0.75% ropivacaine on each side) and group B (local anesthesia). To investigate procedural pain associated with PVP, the visual analog scale score was assessed at each surgical stage: before the incision (stage 1), transpedicular approach (stage 2), and polymethylmethacrylate cement injection (stage 3). After the procedure, patients were asked about their surgical experience and satisfaction using the Iowa Satisfaction with Anesthesia Scale. Periprocedural complications were also recorded. RESULTS: A total of 63 patients (78.65 y of age) were finally enrolled: 30 from group A and 33 from group B. In both groups, a significant ≥2-point increase in procedural pain was observed during PVP compared with that during stage 1 ( P < 0.001). In stages 2 and 3, the pain intensity was significantly lower in group A ( P < 0.001). Upon discharge, the visual analog scale score improved in all groups; however, the Iowa Satisfaction with Anesthesia Scale score was significantly higher in group A ( P < 0.001). There was no difference in periprocedural complications between the two groups ( P = 0.743). CONCLUSION: PVP causes significant procedural pain, and PVNB is a potentially effective modality for enhancing patient satisfaction and reducing procedural pain.


Assuntos
Fraturas por Compressão , Bloqueio Nervoso , Fraturas por Osteoporose , Dor Processual , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Vertebroplastia/efeitos adversos , Vertebroplastia/métodos , Fraturas por Compressão/cirurgia , Fraturas por Compressão/complicações , Fraturas da Coluna Vertebral/etiologia , Fraturas da Coluna Vertebral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Fraturas por Osteoporose/complicações , Fraturas por Osteoporose/cirurgia , Bloqueio Nervoso/efeitos adversos
13.
Bioeng Transl Med ; 8(1): e10348, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36684108

RESUMO

Changes in specific circulating RNA (circRNA) expressions can serve as diagnostic noninvasive biomarkers for prostate cancer (PCa). However, there are still unmet needs, such as unclear types and roles of circRNAs, PCa detection in benign prostatic hyperplasia (BPH) by unstandardized methods, and limitations of sample volume capacity and low circRNA concentrations. This study reports a simple and rapid circRNA enrichment and isolation technique named "HAZIS-CirR" for the analysis of urinary circRNAs. The method utilizes homobifunctional hydrazides with amine-modified zeolite and polyvinylidene fluoride (PVDF) syringe filtration for combining electrostatic and covalent coupling and size-based filtration, and it offers instrument-free isolation of circRNAs in 20 min without volume limitation, thermoregulation, and lysis. HAZIS-CirR has high capture efficiency (82.03%-92.38%) and a 10-fold more sensitive detection limit (20 fM) than before enrichment (200 fM). The clinical utility of HAZIS-CirR is confirmed by analyzing circulating mRNAs and circulating miRNAs in 89 urine samples. Furthermore, three miRNA panels that differentiate PCa from BPH and control, PCa from control, and BPH from control, respectively, are established by comparing miRNA levels. HAZIS-CirR will be used as an optimal and established method for the enrichment and isolation of circRNAs as diagnostic, prognostic, and predictive biomarkers in human cancers.

14.
IEEE Trans Med Imaging ; 42(9): 2643-2652, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37030782

RESUMO

For human brain magnetic resonance imaging (MRI), high channel count ( ≥ 32 ) radiofrequency receiver coil arrays are utilized to achieve maximum signal-to-noise ratio (SNR) and to accelerate parallel imaging techniques. With ultra-high field (UHF) MRI at 7 tesla (T) and higher, dipole antenna arrays have been shown to generate high SNR in the deep regions of the brain, however the array elements exhibit increased electromagnetic coupling with one another, making array construction more difficult with the increasing number of elements. Compared to a classical dipole antenna array, a sleeve antenna array incorporates the coaxial ground into the feed-point, resulting in a modified asymmetric antenna structure with improved intra-element decoupling. Here, we extended our previous 16-channel sleeve transceiver work and developed a 32-channel azimuthally arranged sleeve antenna receive-only array for 10.5 T human brain imaging. We experimentally compared the achievable SNR of the sleeve antenna array at 10.5 T to a more traditional 32-channel loop array bult onto a human head-shaped former. The results obtained with a head shaped phantom clearly demonstrated that peripheral intrinsic SNR can be significantly improved compared to a loop array with the same number of elements- except for the superior part of the phantom where sleeve antenna elements are not located.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Ondas de Rádio , Imagens de Fantasmas , Razão Sinal-Ruído , Desenho de Equipamento
15.
J Orthop Surg Res ; 18(1): 29, 2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36631903

RESUMO

BACKGROUND: Many factors associated with chronic low back pain (CLBP) have been proposed, including individual, psychosocial, and physical factors. However, these associated factors are still controversial. PURPOSE: (1) To determine the prevalence of CLBP and (2) to analyze factors associated with CLBP in the general population using a nationally representative sample of South Koreans. STUDY DESIGN: Cross-sectional study. PATIENT SAMPLE: Data from versions IV-1, -2, and -3 of the Korea National Health and Nutrition Examination Survey (KNHANES), which were performed in 2007, 2008, and 2009, respectively (n = 24,871). OUTCOME MEASURES: Multiple logistic regression analysis was performed to determine the association between several factors (age, gender, alcohol consumption, household income, education level, mid-intensity physical activity, depressive symptoms, vitamin D level, and comorbidities [stroke, ischemic heart disease, knee osteoarthritis, asthma, COPD, cancer history]) and CLBP. METHODS: CLBP status was surveyed using a self-reported questionnaire. Demographic, socioeconomic status, comorbidities, and other factors were evaluated from health questionnaires, health and physical examinations, and laboratory tests. To analyze the association between these factors and CLBP, we used multiple logistic regression analysis. RESULTS: Data from 17,038 participants were included in the final analysis, including 2,693 with CLBP and 14,345 without. The prevalence of CLBP was 15.8% in South Korean subjects, with a prevalence of 11.8% in men and 24.5% in women. After regression analysis, we found advanced age, female gender, mid-intensity physical activity, depressive symptoms, stroke, ischemic heart disease, knee arthritis, asthma, COPD, and cancer history were positively associated with CLBP. In contrast, alcohol consumption ≥ 1 drink per month, increased household income, higher education level, and vitamin D insufficiency were negatively associated with CLBP. CONCLUSIONS: Our study showed that CLBP was most common in the elderly and women in the general South Korean population. Several individual, socioeconomic, lifestyle, and health-related factors were associated with CLBP. These results demonstrate the influence of these factors on CLBP in the general population and suggest that consideration of these factors may improve the management of CLBP.


Assuntos
Asma , Dor Crônica , Dor Lombar , Isquemia Miocárdica , Doença Pulmonar Obstrutiva Crônica , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , Idoso , Estudos Transversais , Inquéritos Nutricionais , Dor Lombar/diagnóstico , Dor Lombar/epidemiologia , Prevalência , República da Coreia/epidemiologia , Dor Crônica/epidemiologia
16.
Asian Spine J ; 17(2): 392-400, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36717091

RESUMO

Oblique lumbar interbody fusion is a minimally invasive procedure for treating degenerative lumbar disease. Its advantages include correcting coronal and sagittal spinal alignment and indirect neural decompression. However, achieving a successful outcome is limited in some patients who need direct decompression for central canal lesions including hard stenotic lesions (endplate or facet articular osteophytes and ossification of posterior longitudinal ligaments) and sequestration of the disk. Biportal endoscopic spinal surgery is a minimally invasive technique, which directly decompresses the lesion. By taking advantage of two procedures, in a longlevel lumbar lesion, alignment correction and direct decompression can be both achieved. Herein, the authors introduce multilevel lumbar fusion through oblique lumbar interbody fusion and selective direct decompression through biportal endoscopic spinal surgery and discuss the surgical indications, surgical pitfalls, and recommendations for application. Consequently, it is regarded as a minimally invasive interbody fusion method for patients with multilevel lumbar degenerative degeneration.

17.
J Am Geriatr Soc ; 71(9): 2822-2833, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37195174

RESUMO

BACKGROUND: Poor functional status is a key marker of morbidity, yet is not routinely captured in clinical encounters. We developed and evaluated the accuracy of a machine learning algorithm that leveraged electronic health record (EHR) data to provide a scalable process for identification of functional impairment. METHODS: We identified a cohort of patients with an electronically captured screening measure of functional status (Older Americans Resources and Services ADL/IADL) between 2018 and 2020 (N = 6484). Patients were classified using unsupervised learning K means and t-distributed Stochastic Neighbor Embedding into normal function (NF), mild to moderate functional impairment (MFI), and severe functional impairment (SFI) states. Using 11 EHR clinical variable domains (832 variable input features), we trained an Extreme Gradient Boosting supervised machine learning algorithm to distinguish functional status states, and measured prediction accuracies. Data were randomly split into training (80%) and test (20%) sets. The SHapley Additive Explanations (SHAP) feature importance analysis was used to list the EHR features in rank order of their contribution to the outcome. RESULTS: Median age was 75.3 years, 62% female, 60% White. Patients were classified as 53% NF (n = 3453), 30% MFI (n = 1947), and 17% SFI (n = 1084). Summary of model performance for identifying functional status state (NF, MFI, SFI) was AUROC (area under the receiving operating characteristic curve) 0.92, 0.89, and 0.87, respectively. Age, falls, hospitalization, home health use, labs (e.g., albumin), comorbidities (e.g., dementia, heart failure, chronic kidney disease, chronic pain), and social determinants of health (e.g., alcohol use) were highly ranked features in predicting functional status states. CONCLUSION: A machine learning algorithm run on EHR clinical data has potential utility for differentiating functional status in the clinical setting. Through further validation and refinement, such algorithms can complement traditional screening methods and result in a population-based strategy for identifying patients with poor functional status who need additional health resources.


Assuntos
Registros Eletrônicos de Saúde , Aprendizado de Máquina , Humanos , Feminino , Idoso , Masculino , Algoritmos , Hospitalização , Comorbidade
18.
Appl Environ Microbiol ; 78(16): 5781-7, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22685135

RESUMO

Although respirators and filters are designed to prevent the spread of pathogenic aerosols, a stockpile shortage is anticipated during the next flu pandemic. Contact transfer and reaerosolization of collected microbes from used respirators are also a concern. An option to address these potential problems is UV irradiation, which inactivates microbes by dimerizing thymine/uracil in nucleic acids. The objective of this study was to determine the effects of transmission mode and environmental conditions on decontamination efficiency by UV. In this study, filters were contaminated by different transmission pathways (droplet and aerosol) using three spraying media (deionized water [DI], beef extract [BE], and artificial saliva [AS]) under different humidity levels (30% [low relative humidity {LRH}], 60% [MRH], and 90% [HRH]). UV irradiation at constant intensity was applied for two time intervals at each relative humidity condition. The highest inactivation efficiency (IE), around 5.8 logs, was seen for DI aerosols containing MS2 on filters at LRH after applying a UV intensity of 1.0 mW/cm(2) for 30 min. The IE of droplets containing MS2 was lower than that of aerosols containing MS2. Absorption of UV by high water content and shielding of viruses near the center of the aggregate are considered responsible for this trend. Across the different media, IEs in AS and in BE were much lower than in DI for both aerosol and droplet transmission, indicating that solids present in AS and BE exhibited a protective effect. For particles sprayed in a protective medium, RH is not a significant parameter.


Assuntos
Aerossóis , Filtros de Ar/virologia , Descontaminação/métodos , Levivirus/isolamento & purificação , Levivirus/efeitos da radiação , Raios Ultravioleta , Umidade , Fatores de Tempo
19.
J Aerosol Sci ; 46: 77-82, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32226124

RESUMO

In the event of a pandemic, the general public would use filters as protective devices. However, most commercial filters only remove airborne viruses physically without inactivating them, allowing reproduction on the surface and yielding the mask as a fomite. The objective of this study was to investigate the inactivation performance of dialdehyde starch (DAS) treated filters against airborne viruses. The viable removal efficiency by and relative survivability on the biocidal filters prepared with dialdehyde starch compared to untreated filters were investigated using MS2 bacteriophage at high relative humidity (80-90%) and room temperature. Experimental results showed no significant difference in viable removal efficiency and pressure drop between the treated and untreated filters for polypropylene filtering facepiece respirators. The pressure drop of DAS treated cellulose filters significantly decreased although there was no significant change in viable removal efficiency; the combination of these two factors resulted in an increase of filter quality. All biocidal filters showed a significantly lower relative survivability than untreated filters, and the relative survivability decreased as the concentration of DAS increased. The biocidal filter treated with 4% DAS presented an average of 30% survivability compared to the baseline of untreated filters. The results demonstrate that dialdehyde starch can be incorporated onto filters to provide an effective means for inactivating MS2 viruses through surface contact.

20.
Am J Med Qual ; 37(5): 434-443, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35583984

RESUMO

The authors present a tool to improve gaps in patient safety using the electronic health record. The tool integrates gap identification, passive alerts, and actions into a single interface embedded within clinicians' workflow. The tool was developed to address venous thromboembolism prophylaxis, prevention of hypo- and hyperglycemia, code status documentation, bowel movement frequency, and skilled nursing facility transitions. Alerts and actions during silent and live periods were retrospectively analyzed. The most prevalent safety gaps were lack of venous thromboembolism prophylaxis (40.4% of alerts), constipation (19.3%), and lack of code status (18.4%). Disparities in safety gaps were present by patient race, sex, and socioeconomic status. Usability testing showed positive feedback without significant alert burden. Thus, a safety gap tool was successfully built to study and address patient safety issues. The tool's strengths are its integration within the electronic health record, ease of use, customizability, and scalability.


Assuntos
Registros Eletrônicos de Saúde , Tromboembolia Venosa , Anticoagulantes/uso terapêutico , Humanos , Segurança do Paciente , Estudos Retrospectivos , Tromboembolia Venosa/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA