Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Arch Otorhinolaryngol ; 281(1): 43-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37466660

RESUMO

PURPOSE: In cochlear implantation with flexible lateral wall electrode arrays, a cochlear coverage (CC) range between 70% and 80% is considered ideal for optimal speech perception. To achieve this CC, the cochlear implant (CI) electrode array has to be chosen according to the individual cochlear duct length (CDL). Here, we mathematically analyzed the suitability of different flexible lateral wall electrode array lengths covering between 70% and 80% of the CDL. METHODS: In a retrospective cross-sectional study preoperative high-resolution computed tomography (HRCT) from patients undergoing cochlear implantation was investigated. The CDL was estimated using an otosurgical planning software and the CI electrode array lengths covering 70-80% of the CDL was calculated using (i) linear and (ii) non-linear models. RESULTS: The analysis of 120 HRCT data sets showed significantly different model-dependent CDL. Significant differences between the CC of 70% assessed from linear and non-linear models (mean difference: 2.5 mm, p < 0.001) and the CC of 80% assessed from linear and non-linear models (mean difference: 1.5 mm, p < 0.001) were found. In up to 25% of the patients none of the existing flexible lateral wall electrode arrays fit into this range. In 59 cases (49,2%) the models did not agree on the suitable electrode arrays. CONCLUSIONS: The CC varies depending on the underlying CDL approximation, which critically influences electrode array choice. Based on the literature, we hypothesize that the non-linear method systematically overestimates the CC and may lead to rather too short electrode array choices. Future studies need to assess the accuracy of the individual mathematical models.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Estudos Retrospectivos , Estudos Transversais , Dinâmica não Linear , Cóclea/diagnóstico por imagem , Cóclea/cirurgia
2.
Chemistry ; 28(33): e202200626, 2022 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-35420718

RESUMO

S-F-bond activation of sulfur tetrafluoride at [Rh(Cl)(tBu xanPOP)] (1; tBu xanPOP=9,9-dimethyl-4,5-bis-(di-tert-butylphosphino)-xanthene) led to the formation of the cationic complex [Rh(F)(Cl)(SF2 )(tBu xanPOP)][SF5 ] (2 a) together with trans-[Rh(Cl)(F)2 (tBu xanPOP)] (3) and cis-[Rh(Cl)2 (F)(tBu xanPOP)] (4) which both could also be obtained by the reaction of SF5 Cl with 1. In contrast to that, the conversion of SF4 at the methyl complex [Rh(Me)(tBu xanPOP)] (5) gave the isolable and room-temperature stable cationic λ4 -trifluorosulfanyl complex [Rh(Me)(SF3 )(tBu xanPOP)][SF5 ] (6). Treatment of 6 with the Lewis acids BF3 or AsF5 produced the dicationic difluorosulfanyl complex [Rh(Me)(SF2 )(tBu xanPOP)][BF4 ]2 (8 a) or [Rh(Me)(SF2 )(tBu xanPOP)][AsF6 ]2 (8 b), respectively. Refluorination of 8 a was possible with the use of dimethylamine giving [Rh(Me)(SF3 )(tBu xanPOP)][BF4 ] (9). A reaction of 6 with trichloroisocyanuric acid (TClCA) gave the fluorido complex [Rh(F)(Cl)(SF2 )(tBu xanPOP)][Cl] (2 b) together with chloromethane and SF5 Cl.

3.
Chemistry ; 26(31): 6945-6963, 2020 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-31840851

RESUMO

Binary sulfur fluorides exhibit an interesting reactivity towards transition metal complexes. They open up routes for the generation of sulfur-containing building blocks. Often ligands with particular properties can be constructed. This includes their ability to transfer sulfur atoms or polysulfide units as well as fluorination reactions. This Minireview provides an insight into the reactivity of the binary and ternary sulfur halides S2 Cl2 , SCl2 , SF4 , SF6 and SF5 Cl towards transition-metal compounds.

4.
J Vis Exp ; (198)2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-37590502

RESUMO

Impedance measurements are routinely performed during cochlear implantation (CI) after finalized electrode insertion. They may allow conclusions on the electrode's and implant's function. In the postoperative setting, the analysis of impedance changes enables the identification of scarring or inflammation processes around the electrode. Recent studies report associations between impedance telemetry and the site of stimulation. Consequently, repeated impedance measurements during cochlear implant electrode insertion may enable objective feedback on whether the electrode is positioned inside the perilymph or outside the inner ear. With the presented novel method, impedances can be measured in real-time during cochlear implantation. This protocol systematically explains how to perform repeated impedance recordings during CI surgery. These repeated measurements are challenging since they depend on multiple intraoperative methodological factors starting with the draping of the patient. Thus, for successful recordings, a standardized procedure is mandatory. In this article, we comprehensively illustrate the system setup and procedure of performing intraoperative measurements during CI surgery.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Impedância Elétrica , Cicatriz , Telemetria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA