Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Cardiovasc Disord ; 24(1): 149, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475690

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is a prevalent disease that triggers systemic pathological changes including cardiac, respiratory, hepatic and digestive, hematopoietic, renal and skin issues. The burden of extra-cardiac manifestations has not been well described in TR patients and the clinical impact is unknown. METHODS: Patients with severe or more-than-severe TR during hospitalization, who did not have any previous cardiac procedures, hemodynamically significant congenital heart disease or concomitant severe aortic or mitral valve disease, were retrospectively analyzed. Pre-specified criteria and diagnosis of baseline characteristics were used to evaluate the presence of extra-cardiac manifestations secondary to TR after excluding comorbidities that may also lead to corresponding abnormalities. Extra-cardiac involvements encompass respiratory, hepatic and, digestive, renal, hematopoietic and dermatic system. Staging criteria are defined as no extra-cardiac system involvement in Stage 1, one in Stage 2, at least two extra-cardiac involvements in Stage 3 and any end-stage organ failure in Stage 4. A telephone follow-up was conducted to record the composite endpoint namely all-cause death or cardiac rehospitalization after the index hospitalization. RESULTS: A total of 258 patients were identified with a median age of 73 (interquartile range [IQR]: 62-83) years and 52.3% were female. Severe TR and more-than-severe TR patients accounted for 92.6% and 7.4% of the cohort. There were 20.5%, 27.5%, 37.6% and 14.3% of patients from Stage 1 to 4 respectively. The follow-up time was at a median of 251 (IQR: 183-324) days. TR Patients in Stage 3&4 were at an increased risk with borderline statistical significance to experience the composite endpoint compared to patients in Stage 1&2 (odds ratio [OR] 1.9, 95% confidence interval [CI] 1.0 to 3.7, P = 0.049). CONCLUSIONS: Approximately half of patients with at least severe TR presented with two or more extra-cardiac systemic manifestations, which may incur a 1.9-fold higher risk of all-cause death or cardiac rehospitalization than TR patients with one or less extra-cardiac involvement.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Insuficiência da Valva Tricúspide/etiologia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Medição de Risco , Hemodinâmica
2.
Rev Cardiovasc Med ; 24(1): 11, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39076857

RESUMO

Background: As an emerging arrhythmia monitor, ambulatory smartwatch electrocardiogram (ECG) provides an option for home-based monitoring of delayed new-onset arrhythmic events after transcatheter aortic valve replacement (TAVR). We aimed to validate the diagnostic efficacy of a consumer smartwatch ECG in TAVR recipients, while further explore the occurrence rate of both tachy- and brady-arrhythmia for 30 days after discharge to support risk management. Methods: Consecutive TAVR recipients from February 26th, 2021 to December 13th, 2021 were enrolled prospectively, receiving simultaneous 24-hour Holter and 12-lead ECG compared with smartwatch ECG during hospitalization and daily smartwatch ECG collection for 30 days after discharge. Results: Among 110 patients, the efficacy of smartwatch ECG presented sensitivity and specificity in diagnosing atrial fibrillation (AF) as 1.00 and 0.97, left bundle branch block (LBBB) as 0.61 and 0.88, and right bundle branch block (RBBB) as 0.60 and 0.97, respectively, compared with 24-hour Holter; presented sensitivity and specificity in diagnosing AF as 0.88 and 1.00, LBBB as 0.90 and 0.96, and RBBB as 0.83 and 0.94, respectively, compared with 12-lead ECG. At 30-day follow-up, new-onset arrhythmia included new-onset severe conduction disturbance (SCD) (23.6%), new-onset AF (21.8%), new-onset permanent LBBB (14.5%) and new-onset permanent RBBB (0.9%); 69.2% (36/52) of early new-onset LBBB recovered at 30-day follow-up. Conclusions: The diagnostic efficacy of consumer smartwatch ECG in arrhythmic events among TAVR population was acceptable, which provided a recommendable option for home-based management. Clinical Trial Registration: "Continuously ambulatory rhythm monitoring and predictors of electrocardio-related adverse events in 30 days after transcatheter aortic valve replacement"; Identifier: ChiCTR2000041244; http://www.chictr.org.cn/showproj.aspx?proj=66324.

3.
BMC Cardiovasc Disord ; 23(1): 354, 2023 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-37460957

RESUMO

BACKGROUND: We aim to determine predictors of inadequate left ventricular mass index (LVMi) regression at mid-term after transcatheter aortic valve replacement (TAVR), including the potential role of epicardial adipose tissue (EAT). METHODS: We retrospectively reviewed patients with both echocardiographic assessments and multi-slice computed tomography (MSCT) obtained one year after TAVR. The change of LVMi, the volume and the average CT attenuation of EAT from baseline to one-year follow-up was calculated. Patients were divided into two groups by the percentage change of LVMi at a cut-off of 15%. RESULTS: A total of 152 patients were included with a median age of 74 years (interquartile range [IQR] 69-78 years) and 56.6% being male. LVMi decreased (P < 0.0001) while EAT volume increased and the average CT attenuation decreased (both P < 0.0001) at one year. Baseline atrial fibrillation (P = 0.042), mitral regurgitation ≥ mild (P = 0.006), aortic regurgitation (AR) > mild (P = 0.001) and the change in the average CT attenuation of EAT (P = 0.026) were different between the decrease of LVMi ≥ 15% and < 15%. AR > mild at baseline was the only statistically significant predictor of a decrease of LVMi < 15% at one year (OR 0.33, 95% CI: 0.13 to 0.84, P = 0.021) in multivariate regression. CONCLUSIONS: Concomitant more-than-mild AR might predict better left ventricular reverse remodeling regression after TAVR.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Função Ventricular Esquerda , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Remodelação Ventricular
4.
Eur Radiol ; 31(8): 6220-6229, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34156556

RESUMO

OBJECTIVES: We sought to identify the impact of transcatheter aortic valve implantation (TAVI) on changes of fractional flow reserve computed tomography (FFRCT) values and the associated clinical impact. METHODS: A retrospective analysis was done with CT obtained pre-TAVI, prior to hospital discharge and at 1-year follow-up, which provided imaging sources for the calculation of FFRCT values based on an online platform. RESULTS: A total of 190 patients were enrolled. Patients with pre-procedural FFRCT value > 0.80 (i.e., negative) and ≤ 0.80 (i.e., positive) demonstrated a significantly opposite change in the value after TAVI (0.8798 vs. 0.8718, p < 0.001 and 0.7634 vs. 0.8222, p < 0.001, respectively). The history of coronary artery disease (CAD) was identified as an independent predictor for FFRCT changing from negative to positive after TAVI (odds ratio [OR] 2.927, 95% confidence interval [CI] 1.130-7.587, p = 0.027), with lesions more severely stenosed (OR 1.039, 95% CI 1.003-1.076, p = 0.034) and in left anterior descending coronary artery (LAD) (OR 3.939, 95% CI 1.060-14.637, p = 0.041) being prone to change. CONCLUSIONS: TAVI directly brings improvement in FFRCT values in patients with compromised coronary flow. Patients with a history of CAD, especially with lesions more severely stenosed and in LAD, were under risk of FFRCT changing from negative to positive after TAVI. KEY POINTS: •The effect of TAVI on coronary hemodynamics might be influenced by different ischemic severity and coronary territories reflected by FFRCT values. •As different FFRCT variations did not impact outcomes of TAVI patients, AS, but not coronary issues, may be the primary problem to affect, which needs further validation.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Substituição da Valva Aórtica Transcateter , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Hemodinâmica , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
5.
BMC Cardiovasc Disord ; 21(1): 590, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34876008

RESUMO

BACKGROUND: Optimal projection is essential for valve deployment during transcatheter aortic valve implantation (TAVI). The purpose of this study was to propose an approach to predict optimal projection in TAVI candidates with different aortic valve anatomies. METHODS: 331 patients undergoing self-expanding TAVI were included and the so-called non-coronary cusp (NCC)-parallel technique was utilized, which generated the predicted projection by connecting NCC commissures on the transverse plane on the pre-procedural computed tomography images. RESULTS: 37.8% of the study cohort were bicuspid aortic valve (BAV) patients. Around 80% of both NCC-parallel views and final views were in the right anterior oblique (RAO) and caudal (CAU) quadrant. There was less than 5° change required from the NCC-parallel view to the final implanted view in 79% of tricuspid aortic valve (TAV) patients but only in 27% (13/48) of type 0 BAV patients with coronary arteries originated from the different cusps. After excluding the above mentioned BAV patients, 62.3% (48/77) of BAV patients needed less than 5° change to achieve optimal projection and only in 8 patients, the angular change was larger than 10° in either left/right anterior oblique or cranial/caudal direction. CONCLUSIONS: The NCC-parallel technique provides reliable prediction for optimal projection in self-expanding TAVI in all TAV and most BAV patients, with a vast majority of views in the RAO and CAU quadrant.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/cirurgia , Tomografia Computadorizada Multidetectores , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Valva Aórtica/anormalidades , Tomada de Decisão Clínica , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese
6.
Herz ; 46(Suppl 2): 166-172, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32880663

RESUMO

BACKGROUND: Some patients referred for transcatheter aortic valve replacement (TAVR) have excessively large annuli (ELA) without device options according to current sizing charts. This retrospective study aims to summarize the presentation and outcomes of ELA patients receiving first-generation self-expanding valves. METHODS: The TAVR database was reviewed in search for cases of self-expanding valves. Patients who had annuli exceeding the perimeter limit on the device sizing chart were referred to as the ELA group. Patients who had annuli within the range covered by the two largest sizes and received the corresponding valve size served as the control group (CG). Baseline, procedures, outcomes, and imaging characteristics on multislice computed tomography (MSCT), such as native anatomy and postimplant stent geometry, were compared. RESULTS: A total of 28 patients were included in the ELA group and 82 in the CG. The patients in the ELA group were younger than those in the CG (72.5 ± 6.2 vs. 75.4 ± 5.8 years, P = 0.03). The median intended perimeter oversizing in relation to the annulus in the ELA group was much smaller than in the CG (-0.4 [-4.6, 4.1] % vs. 16.1 [11.7, 20.8] %, P < 0.01). The calcium burden in the aortic root was around 1.3-fold greater in the ELA group than the CG (756.0 [534.5, 1670.9] vs. 582.1 [310.3, 870.9] mm3, P = 0.01). The need for second valve implantation was higher in ELA (21.4% vs. 12.2%, P = 0.23) but no valve embolization was encountered. The 1­year follow-up was comparable, including >mild paravalvular leak. CONCLUSION: Under cautious patient selection using MSCT, TAVR with self-expanding valves in patients with ELA appears feasible. Supra-annular structures likely provide the extra anchoring.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 96(7): 1491-1497, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32400115

RESUMO

OBJECTIVE: We hypothesize that different degree of pre-existing aortic regurgitation (AR) may affect the presence of hypo-attenuated leaflet thickening (HALT) after transcatheter aortic valve replacement (TAVR). BACKGROUND: The mechanism of the presence of HALT post-TAVR is not fully understood. METHODS: We retrospectively evaluated the post-procedural multi-slice computed tomography (MSCT) before discharge for evidence of HALT. Patients were grouped according to the degree of pre-existing AR. Baseline, native anatomy and procedure details were compared, then multivariate regression was performed. RESULTS: MSCT analyzed was performed at a median of 6 days post-TAVR in 179 patients. HALT was detected in 10.6% of patients. After adjusting for variables that were significantly different between groups, pre-existing ≥ moderate AR was protective to the risk of HALT (OR 0.15, 95% CI 0.03-0.84, p = .03). Stratifying for factors that might explain the impact of pre-existing AR on HALT, patients with a small Sinus of Valsalva, non-eccentric remodeling and receiving a large bioprosthesis experienced a sevenfold higher risk for HALT (OR 7.16, 95% CI 2.05-25.08, p = .002). CONCLUSIONS: Patients underwent TAVR with pre-existing ≥ moderate AR appeared to experience a lower incidence of early HALT compared to those patients with less than moderate AR, which may be explained by a larger Sinus of Valsalva and a higher proportion of LV eccentric remodeling.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
8.
Catheter Cardiovasc Interv ; 95 Suppl 1: 616-623, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31943783

RESUMO

OBJECTIVES: We evaluated the safety and usefulness of preparatory anatomical reshaping with a geometric hourglass-shaped balloon to optimize transcatheter aortic valve replacement (TAVR) outcomes in bicuspid aortic valve (BAV) stenosis. BACKGROUND: TAVR has been increasingly performed for BAV stenosis; however, technical challenges remain. Procedural results are suboptimal given unfavorable valvular anatomies. METHODS: Eligible patients with BAV stenosis were enrolled to undergo aortic valve predilatation with the hourglass-shaped TAV8 balloon before TAVR using the self-expandable Venus A-Valve. Procedural details and outcomes were compared to a sequential group of patients with BAV who underwent TAVR with the same device following preparatory dilatation using a cylindrical balloon. RESULTS: A total of 22 patients were enrolled in the TAV8 group and 53 were included in the control group. Valve downsizing was less common in the TAV8 group (36.4 vs. 67.9%; p = .012). Stable valve release and optimal implant depth were consistently achieved in the TAV8 group with no requirement for a second valve (0 vs. 17.0%; p = .039) and with higher device success rates (100.0 vs 77.4%; p = .014). Residual aortic regurgitation graded as ≥mild was less common in the TAV8 group (13.6 vs 45.3%; p = .009). Mortality was similar (0 vs. 3.8%; p = 1); no major/disabling stroke or conversion to open-heart surgery was seen in either group within 30 days. CONCLUSIONS: Compared with standard cylindrical balloon valvuloplasty, preparatory reshaping with the hourglass-shaped balloon before self-expandable TAVR in BAV was associated with significantly better procedural results and may encourage more promising outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/instrumentação , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Feminino , Humanos , Masculino , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
9.
BMC Cardiovasc Disord ; 20(1): 229, 2020 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-32423380

RESUMO

BACKGROUND: To explore why bicuspid aortic stenosis has certain clinical differences from the tricuspid morphology, we evaluated the metabolomics profile involved in bicuspid aortic valve (BAV) aortic stenosis prior to and after transcatheter aortic valve replacement (TAVR) in comparison with tricuspid aortic valve (TAV). METHODS: In this TAVR cohort with prospectively collected data, blood samples were obtained before TAVR valve deployment and at the 7th day after TAVR, which were then sent for liquid and gas chromatography-mass spectrometry detection. Besides comparisons between BAV and TAV, BAV patients were also divided in subgroups according to baseline hemodynamics (i.e. maximal transaortic velocity, Vmax) and post-procedural reverse left ventricular (LV) remodeling (i.e. the change in LV mass index from baseline, ∆LVMI) for further analysis. Metabolic differences between groups were identified by integrating univariate test, multivariate analysis and weighted correlation network analysis algorithm. RESULTS: A total of 57 patients were enrolled including 33 BAV patients. The BAV group showed lower arginine and proline metabolism both before and post TAVR than TAV represented by decreased expression of L-Glutamine. In BAV subgroup analysis, patients with baseline Vmax > 5 m/s (n = 11) or the 4th quartile of change in ∆LVMI at one-year follow-up (i.e. poorly-recovered LV, n = 8) showed elevated arachidonic acid metabolism compared with Vmax < 4.5 m/s (n = 12) or the 1st quartile of ∆LVMI (i.e. well-recovered LV, n = 8) respectively. CONCLUSIONS: Difference in arginine and proline metabolism was identified between BAV and TAV in TAVR recipients. Elevated arachidonic acid metabolism may reflect more severe baseline hemodynamics and worse LV reserve remodeling after TAVR in BAV.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Metabolismo Energético , Doenças das Valvas Cardíacas/cirurgia , Metabolômica , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/fisiopatologia , Ácido Araquidônico/sangue , Arginina/sangue , Doença da Válvula Aórtica Bicúspide , Biomarcadores/sangue , Feminino , Doenças das Valvas Cardíacas/sangue , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/fisiopatologia , Hemodinâmica , Humanos , Masculino , Prolina/sangue , Estudos Prospectivos , Recuperação de Função Fisiológica , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
10.
J Interv Cardiol ; 2019: 7348964, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31777470

RESUMO

OBJECTIVES: We aimed to assess the procedural and clinical results of transcatheter aortic valve replacement (TAVR) for nonraphe bicuspid aortic stenosis (AS) with coronary vs mixed cusp fusion. BACKGROUND: It remains unclear whether cusp fusion morphology affects TAVR outcomes in patients with nonraphe bicuspid AS. METHODS: This retrospective study enrolled consecutive patients with severe symptomatic AS and type-0 bicuspid aortic valve, who underwent TAVR at our institution between 2012 and 2017. TAVR outcomes were defined based on the Valve Academic Research Consortium-2 recommendations. RESULTS: Compared to patients with mixed cusp fusion (44/71), those with coronary cusp fusion (27/71) had a larger ellipticity index for the aortic annulus (21.9% ± 9.0% vs 15.6% ± 9.3%, p=0.007) and increased left ventricular outflow tract obstruction (31.1% ± 9.4% vs 26.9% ± 7.5%, p=0.04) but comparable rates of second valve implantation (15.9% vs 14.8%), mild paravalvular leakage (PVL, 38.5% vs 30.2%), permanent pacemaker implantation (PPM, 25.9% vs 15.9%), and 30-day mortality (7.4% vs 6.8%). Use of a first-generation transcatheter heart valve was associated with higher risk for mild PVL (odds ratio (OR) = 4.37; 95% confidence interval (95% CI) = 1.14-16.75; p=0.03) but not PPM (OR = 0.77; 95% CI = 0.22-2.62; p=0.67), whereas a larger oversizing ratio tended to be associated with a higher PPM rate (OR = 1.49; 95% CI = 0.46-4.86; p=0.51) but lower incidence of mild PVL (OR = 0.51; 95% CI = 0.19-1.35; p=0.17). CONCLUSIONS: In AS patients with type-0 bicuspid valves, cusp fusion morphology does not affect the procedural or clinical results of TAVR. Use of second-generation transcatheter heart valves may provide more favorable results in such patients. This trial is registered with NCT01683474.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese
11.
J Interv Cardiol ; 31(6): 878-884, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30079561

RESUMO

BACKGROUND: Studies of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) specifically for bicuspid aortic valve (BAV) patients are lacking. We aim to delineate possible aspects that might affect the incidence of PPI in a retrospective cohort of BAV patients treated with early-generation self-expanding devices. METHODS: A total of 80 patients with bicuspid morphology who successfully underwent TAVR by self-expanding devices without prior PPI were included. Baseline clinical, echocardiographic, and angiographic characteristics, procedural and post-procedural details were collected. RESULTS: The incidence of PPI after early-generation self-expanding valves in this BAV cohort was 26.3%. Baseline characteristics were comparable between patients requiring PPI post-TAVR or not. Perimeter oversizing greater than 20% significantly increased the risk of PPI compared with an oversizing of 10-20% (OR 5.08 [1.22, 21.07], P = 0.03). The proportion of patients with a depth of implantation greater than 6 mm was significantly higher in those who required PPI (82.4% vs 54.3%, P = 0.04). When testing the impact of depth of implantation >6 mm and oversizing in different morphologies, only in type 1 bicuspid patients and by oversizing>20% increased the risk of PPI (OR 12.00 [1.25, 115.36], P = 0.03) compared with an oversizing of 10-20%. CONCLUSIONS: Excessive perimeter oversizing in relation to aortic annulus and depth of implantation greater than 6 mm should be avoided to improve PPI post-TAVR for BAV patients receiving self-expanding devices, especially for type 1 BAV.


Assuntos
Valva Aórtica/anormalidades , Arritmias Cardíacas/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Marca-Passo Artificial/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Arritmias Cardíacas/etiologia , Doença da Válvula Aórtica Bicúspide , Feminino , Humanos , Incidência , Masculino , Tomografia Computadorizada Multidetectores , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
12.
J Thromb Thrombolysis ; 45(3): 463-465, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29478129

RESUMO

The imaging finding of hypo-attenuated leaflet thickening (HALT) on bioprosthesis after transcatheter aortic valve replacement (TAVR) has been reported. The underlying mechanism is not clear, but leaflet thrombosis is speculated to be the cause. Heterogeneous antiplatelet responses may play a role in the process. This is a prospective, single-center pilot study in patients who received successful TAVR from June 2012 to November 2016. HALT on post-procedural multi-detector computed tomography. We thoroughly genotyped 34 SNPs and 8 SNPs that have been reported for clopidogrel and aspirin resistance. A total of 148 patients were enrolled. There were 15 patients demonstrating signs of HALT. Patients with HALT had a higher rate of atrial fibrillation (AF) pre-TAVR (33.3 vs. 7.5%, P = 0.01). We found that rs4244285 G>A polymorphism of the CYP2C19 gene was associated with the risk of HALT in the overdominant model (OR 4.00 [1.15-13.97], P = 0.02 for GA vs. GG+AA) adjusted by sex and the presence of pre-TAVR AF. Antiplatelet drug resistance is a reasonable possibility involved in HALT. Potential directions were suggested in polymorphisms of the CYP2C19 gene.


Assuntos
Inibidores da Agregação Plaquetária/uso terapêutico , Polimorfismo de Nucleotídeo Único , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aspirina/farmacologia , Aspirina/uso terapêutico , Clopidogrel , Citocromo P-450 CYP2C19/genética , Resistência a Medicamentos/genética , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Projetos Piloto , Estudos Prospectivos , Ticlopidina/análogos & derivados , Ticlopidina/farmacologia , Ticlopidina/uso terapêutico
13.
Catheter Cardiovasc Interv ; 87 Suppl 1: 570-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26856312

RESUMO

OBJECTIVE: The present study was performed to investigate the relationship between chronic obstructive pulmonary disease (COPD) and transcatheter aortic valve implantation (TAVI). BACKGROUND: Controversies regarding the relationship between COPD and TAVI have intensified. METHODS: A literature review of the PubMed online database was performed, and articles published between January 1, 2002 and March 20, 2015 were analyzed. Random-effect and fixed-effect models were used, depending on the between-study heterogeneity. RESULTS: A total of 28 studies, involving 51,530 patients, were identified in our review. The burden of COPD ranged from 12.5% to 43.4%, and COPD negatively impacted both short-term and long-term all-cause survival (30 days: odds ratio [OR], 1.43, 95% CI, 1.14-1.79; >2 years: hazard ratio [HR], 1.34, 95% CI, 1.12-1.61). COPD was also associated with increased short-term and mid-term cardiac-cause mortality (30 days: OR, 1.29, 95% CI, 1.02-1.64; 1 year: HR: 1.09, 1.02-1.17). Moreover, COPD (OR, 1.97, 95% CI, 1.29-3.0) predicted post-TAVI acute kidney disease. Importantly, chronic kidney disease (CKD) (HR, 1.2, 95% CI, 1.1-1.32) and the distance of the 6 minute walk test (6MWT) (HR, 1.16, 1.06-1.27) predicted TAVI futility in patients with COPD. CONCLUSION: COPD is common among patients undergoing TAVI, and COPD impacts both short- and long-term survival. COPD patients, who had a lower BMI, shorter distance of 6MWT and CKD, were at higher risk for TAVI futility.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Injúria Renal Aguda/epidemiologia , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Índice de Massa Corporal , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Comorbidade , Teste de Esforço , Tolerância ao Exercício , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Modelos Logísticos , Pulmão/fisiopatologia , Masculino , Análise Multivariada , Razão de Chances , Prevalência , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/mortalidade , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Insuficiência Renal Crônica/epidemiologia , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Caminhada
15.
BMJ Open ; 13(12): e078061, 2023 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-38110378

RESUMO

INTRODUCTION: Decisions regarding the optimal timing of intervention for asymptomatic aortic stenosis (AS) are controversial. The study aims to identify potential risk factors for asymptomatic patients with severe AS that are associated with worse prognosis and to evaluate the benefits of early interventions for asymptomatic patients presenting with one or more additional risk factors. METHODS AND ANALYSIS: This is a non-interventional, prospective, open-label, multicentre registry study across China. A total of 1000 patients will be enrolled and categorised as symptomatic or asymptomatic. The primary endpoint is the occurrence of all-cause mortality, stroke, acute myocardial infarction and heart failure-related hospitalisation at 1-year follow-up. In asymptomatic severe AS patients presenting with one or more risk factors, the occurrence rate of the primary endpoint between those who undergo transcatheter aortic valve replacement (TAVR) and those who do not will be compared. We will also compare the occurrence rate of the primary endpoint for asymptomatic severe AS patients with additional risk factors who undergo TAVR with those presenting with symptoms. This study is believed to provide additional evidence to help clinicians identify and refer severe AS patients who are asymptomatic but present with additional risk factors for early intervention of TAVR. ETHICS AND DISSEMINATION: The study protocol has been approved by the local ethics committee of each participating site: West China Hospital, Sichuan University; Sir Run Run Shaw Hospital, Zhejiang University School of Medicine; Second Hospital of Hebei Medical University; Tianjin Chest Hospital; and First Affiliated Hospital of Nanchang University. All participants will provide written informed consent. Study results will be published through academic conferences and peer-reviewed journals. TRIAL REGISTRATION: This study was registered at the Chinese Clinical Trial Registry (https:// www.chictr.org.cn), with the registration number ChiCTR2200064853.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estudos Multicêntricos como Assunto , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Circ Cardiovasc Interv ; 16(12): e013083, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37846559

RESUMO

BACKGROUND: Data concerning the outcomes of transcatheter aortic valve replacement in type 0 bicuspid aortic stenosis (AS) are scarce. The study aims to compare the outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy. METHODS: We enrolled consecutive patients undergoing transcatheter aortic valve replacement for severe AS between 2012 and 2022 in this single-center retrospective cohort study. The primary outcome was mortality, while secondary outcomes included in-hospital complications such as stroke and pacemaker implantation and transcatheter heart valve hemodynamic performance. RESULTS: The number of patients with AS with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy was 328, 302, and 642, respectively. Self-expanding transcatheter heart valves were used in the majority of patients (n=1160; 91.4%). In the matched population, differences in mortality (30 days: 4.2% versus 1.7% versus 1.7%, Poverall=0.522; 1 year: 10% versus 2.3% versus 6.2%, Poverall=0.099) and all stroke (30 days: 1.0% versus 0.9% versus 0.0%, Poverall=0.765; 1 year: 1.4% versus 1.6% versus 1.3%, Poverall=NS) were nonsignificant, and the incidence of overall in-hospital complications was comparable among groups. Ascending aortic diameter was the single predictor of 1-year mortality in type 0 bicuspid patients (hazard ratio, 1.59 [95% CI, 1.03-2.44]; P=0.035). The proportion of patients with a mean residual gradient ≥20 mm Hg was the highest in those with type 0 bicuspid anatomy, although the need for permanent pacemaker implantation was the lowest in this group. CONCLUSIONS: Major clinical outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy are equivalent at short- and mid-term follow-up. These observations merit further exploration in prospective international registries and randomized controlled trials.


Assuntos
Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia
17.
Nat Rev Cardiol ; 20(1): 52-67, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35726019

RESUMO

Indications for transcatheter aortic valve implantation (TAVI) have expanded in many countries to include patients with aortic stenosis who are at low surgical risk, and a similar expansion to this cohort is anticipated elsewhere in the world, together with an increase in the proportion of patients with bicuspid aortic valve (BAV) morphology as the age of the patients being treated decreases. To date, patients with BAV have been excluded from major randomized trials of TAVI owing to anatomical considerations. As a consequence, BAV has been a relative contraindication to the use of TAVI in international guidelines. Although clinical experience and observational data are accumulating, BAV presents numerous anatomical challenges for successful TAVI, despite advances in device design. Furthermore, in those with BAV, substantial geographical variation exists in patient characteristics, clinical approach and procedural strategy. Therefore, in this Roadmap article, we summarize the existing evidence and provide consensus recommendations from an international group of experts on the application of TAVI in patients with BAV in advance of the anticipated growth in the use of this procedure in this challenging cohort of patients.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/etiologia , Valva Mitral , Resultado do Tratamento , Doença da Válvula Aórtica Bicúspide/etiologia , Doença da Válvula Aórtica Bicúspide/cirurgia , Estenose da Valva Aórtica/cirurgia , Padrões de Referência
18.
JACC Cardiovasc Interv ; 15(2): 123-134, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35057982

RESUMO

OBJECTIVES: The aim of this study was to assess cusp symmetry and coronary ostial eccentricity and its impact on coronary access following transcatheter aortic valve replacement (TAVR) using a patient-specific commissural alignment implantation technique. BACKGROUND: TAVR implantation techniques to obtain neocommissural alignment have been introduced. The impact of cusp symmetry and coronary ostial eccentricity on coronary access after TAVR remains unknown. METHODS: Cardiac computed tomographic scans from 200 tricuspid aortic valves (TAVs) and 200 type 1 bicuspid aortic valves (BAVs) were studied. Cusp symmetry and coronary ostial eccentricity were assessed. In addition, the right coronary cusp/left coronary cusp and right coronary artery (RCA)/left coronary artery (LCA) ostia overlap views were calculated and compared. RESULTS: Severe cusp asymmetry (>135°) was more frequent in BAVs (52.5%) than in TAVs (2.5%) (P < 0.001), with the noncoronary cusp being the most common dominant cusp. The RCA ostium was found to be more often eccentric (>20°) than the LCA ostium (28% vs 6%, respectively; P < 0.001). Considering the right/left cusp overlap view, there was <20° deviation between the right coronary cusp-left coronary cusp centered line and the RCA-LCA centered line in 95% of all patients (TAV, 97%; BAV, 93%). The right/left cusp and coronary ostia overlap view differed by <10° and <20° fluoroscopic angulation in 75% and 98% of all cases, respectively. CONCLUSIONS: Using the right/left cusp overlap view to obtain commissural alignment in TAVR is also an effective approach to implant one of the transcatheter heart valve commissures in the near center between both coronary ostia in most TAVs and type 1 BAVs. Preprocedural CT assessment remains crucial to assess cusp symmetry and coronary ostial eccentricity.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Valva Tricúspide/cirurgia
19.
Front Cardiovasc Med ; 9: 794850, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35369357

RESUMO

Objective: We sought to conduct a systematic review and meta-analysis of clinical adverse events in patients undergoing transcatheter aortic valve replacement (TAVR) with bicuspid aortic valve (BAV) vs. tricuspid aortic valve (TAV) anatomy and the efficacy of balloon-expandable (BE) vs. self-expanding (SE) valves in the BAV population. Comparisons aforementioned will be made stratified into early- and new-generation devices. Differences of prosthetic geometry on CT between patients with BAV and TAV were presented. In addition, BAV morphological presentations in included studies were summarized. Method: Observational studies and a randomized controlled trial of patients with BAV undergoing TAVR were included according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. Results: A total of 43 studies were included in the final analysis. In patients undergoing TAVR, type 1 BAV was the most common phenotype and type 2 BAV accounted for the least. Significant higher risks of conversion to surgical aortic valve replacement (SAVR), the need of a second valve, a moderate or severe paravalvular leakage (PVL), device failure, acute kidney injury (AKI), and stroke were observed in patients with BAV than in patients with TAV during hospitalization. BAV had a higher risk of new permanent pacemaker implantation (PPI) both at hospitalization and a 30-day follow-up. Risk of 1-year mortality was significantly lower in patients with BAV than that with TAV [odds ratio (OR) = 0.85, 95% CI 0.75-0.97, p = 0.01]. BE transcatheter heart valves (THVs) had higher risks of annular rupture but a lower risk of the need of a second valve and a new PPI than SE THVs. Moreover, BE THV was less expanded and more elliptical in BAV than in TAV. In general, the rates of clinical adverse events were lower in new-generation THVs than in early-generation THVs in both BAV and TAV. Conclusions: Despite higher risks of conversion to SAVR, the need of a second valve, moderate or severe PVL, device failure, AKI, stroke, and new PPI, TAVR seems to be a viable option for selected patients with severe bicuspid aortic stenosis (AS), which demonstrated a potential benefit of 1-year survival, especially among lower surgical risk population using new-generation devices. Larger randomized studies are needed to guide patient selection and verified the durable performance of THVs in the BAV population.

20.
JACC Cardiovasc Interv ; 15(16): 1652-1660, 2022 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-35981839

RESUMO

BACKGROUND: It is unknown whether the sex difference whereby female transcatheter aortic valve replacement (TAVR) candidates had a lower risk profile, a higher incidence of in-hospital complications, but more favorable short- and long-term survival observed in tricuspid cohorts undergoing TAVR would persist in patients with bicuspid aortic valves (BAVs). OBJECTIVES: The aim of this study was to reexamine the impact of sex on outcomes following TAVR in patients with BAVs. METHODS: In this single-center study, patients with BAVs undergoing TAVR for severe aortic stenosis from 2012 to 2021 were retrospectively included. Baseline characteristics, aortic root anatomy, and in-hospital and 1-year valve hemodynamic status and survival were compared between sexes. RESULTS: A total of 510 patients with BAVs were included. At baseline, women presented with fewer comorbidities. Men had a greater proportion of Sievers type 1 BAV, higher calcium volumes (549.2 ± 408.4 mm3 vs 920.8 ± 654.3 mm3; P < 0.001), and larger aortic root structures. Women experienced more vascular complications (12.9% vs 4.9%; P = 0.002) and bleeding (11.1% vs 5.3%; P = 0.019) and higher residual gradients (16.9 ± 7.7 mm Hg vs 13.2 ± 6.4 mm Hg; P < 0.001), while men were more likely to undergo second valve implantations during index TAVR (6.3% vs 15.9%; P = 0.001). Death at 1 year was not significantly different between sexes (HR: 1.15; 95% CI: 0.56-2.35; P = 0.70). Bleeding (adjusted HR: 4.62; 95% CI: 1.51-14.12; P = 0.007) was the single independent predictor of 1-year death for women. CONCLUSIONS: In patients with BAVs undergoing TAVR, women presented with fewer comorbidities, while men had a greater proportion of type 1 BAV, more calcification, and larger aortic roots. In-hospital outcomes favored men, with fewer complications except for the need for second valve implantation, but 1-year survival was comparable between sexes.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Caracteres Sexuais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA