Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Environ Monit Assess ; 195(12): 1437, 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37940732

RESUMO

To clarify the characteristics of compounds with strong or weak nitrification inhibition in sewage, 64 organic compounds including compounds registered in Pollutant Release and Transfer Register (PRTR) were evaluated in terms of their chemical structures and molecular weights. Nineteen compounds showed strong nitrification inhibition by testing with Nitrosomonas europaea. Compounds with thioamide structures had the lowest median value of EC50 (0.017 mg/L), followed by those with alkyne structures (0.121 mg/L), chlorophenol structures (0.300 mg/L), and then azole structures (0.365 mg/L). In contrast, 33 of the 64 compounds showed weak nitrification inhibition at a concentration of 10 mg/L, 27 of which were categorized into three main groups: long-chain alcohol structures, alkyne structures with a phenyl group, and aromatic structures. Most compounds with strong nitrification inhibition had a low molecular weight (MW) from 50 to 200. Meanwhile, the proportion of compounds with weak nitrification inhibition tended to be greater with increasing MW and such compounds were predominant at higher molecular weights above 300. The correlations of results derived from tests of nitrification inhibition based on ISO 9509 and N. europaea showed that 24 out of 30 compounds provided results that were highly correlated between these tests (R = 0.85), while 4 compounds with chlorophenol structures and 2 compounds with alkyne structures showed weaker inhibition rates in the ISO 9509 test than in the N. europaea test. Our results indicate that the magnitude of nitrification inhibition depends on MW in addition to the chemical structure, which is helpful in the search for the cause of nitrification inhibition in wastewater treatment plants.


Assuntos
Clorofenóis , Esgotos , Nitrificação , Reatores Biológicos , Monitoramento Ambiental , Alcinos , Oxirredução
2.
Pharmacol Res ; 175: 105981, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34798264

RESUMO

Inchinkoto (ICKT) is a popular choleretic and hepatoprotective herbal medicine that is widely used in Japan. Geniposide, a major ingredient of ICKT, is metabolized to genipin by gut microbiota, which exerts a choleretic effect. This study investigates the relationship between stool genipin-producing activity and diversity of the clinical effect of ICKT in patients with malignant obstructive jaundice. Fifty-two patients with malignant obstructive jaundice who underwent external biliary drainage were included. ICKT was administered as three packets per day (7.5 g/day) for three days and 2.5 g on the morning of the fourth day. Stool samples were collected before ICKT administration and bile flow was monitored on a daily basis. The microbiome, genipin-producing activity, and organic acids in stools were analyzed. The Shannon-Wiener (SW) index was calculated to evaluate gut microbiome diversity. The stool genipin-producing activity showed a significant positive correlation with the SW index. Stool genipin-producing activity positively correlated with the order Clostridia (obligate anaerobes), but negatively correlated with the order Lactobacillales (facultative anaerobes). Moreover, stool genipin-producing activity was positively correlated to the concentration valeric acid, but negatively correlated to the concentration of lactic acid and succinic acid. The change of bile flow at 2 and 3 days after ICKT administration showed significant positive correlation with genipin-producing activity (correlation coefficient, 0.40 and 0.29, respectively, P < 0.05). An analysis of stool profile, including stool genipin-producing activity, may predict the efficacy of ICKT. Modification of the microbiome may be a target to enhance the therapeutic effect of ICKT.


Assuntos
Colagogos e Coleréticos/uso terapêutico , Medicamentos de Ervas Chinesas/uso terapêutico , Fezes/química , Microbioma Gastrointestinal/efeitos dos fármacos , Iridoides/metabolismo , Icterícia Obstrutiva/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Bile/química , Ácidos Carboxílicos/metabolismo , Clostridium/genética , Clostridium/metabolismo , Feminino , Microbioma Gastrointestinal/genética , Humanos , Icterícia Obstrutiva/microbiologia , Lactobacillales/genética , Lactobacillales/metabolismo , Masculino , Pessoa de Meia-Idade , Neoplasias/tratamento farmacológico , Neoplasias/microbiologia , Resultado do Tratamento
3.
Metabolomics ; 17(12): 106, 2021 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-34855010

RESUMO

INTRODUCTION: The precise pharmacological action of inchinkoto (ICKT, Yin-Chen-Hao-Tang in Chinese), a hepatoprotective herbal medicine, on total metabolic pathways has not been well investigated. OBJECTIVES: The aim of this study was to explore the serum metabolites reflecting the pharmacological activity of ICKT, and mechanism of action of ICKT using serum metabolome analysis. METHODS: 54 patients with obstructive jaundice due to malignancies were included in this study. ICKT was administered for 3 days. Serum and bile samples were collected before and 1 h after ICKT administration on days 1 and 4. Serum metabolome analysis including ICKT components were performed. RESULTS: The levels of total/direct bilirubin, C-reactive protein, γ-glutamyl transpeptidase, and albumin in the serum were significantly improved after ICKT administration. In the serum metabolome analysis, inosine was the only elevated metabolite on days 1 and 4. Most of the metabolites which were significantly changed after ICKT administration were lipid mediators, and all decreased on day 1. Notably, the levels of many lipid mediators were increased on day 4. The difference in serum aspartic acid 1 h after ICKT administration was significantly correlated with a decrease in the levels of total bilirubin in the serum on day 4. CONCLUSIONS: Using metabolome analysis, we demonstrated several metabolic changes that may be associated with the pharmacological mechanisms of ICKT. The biological implications of these metabolites should be further investigated in basic research studies.


Assuntos
Medicina Herbária , Plantas Medicinais , Humanos , Metaboloma , Metabolômica
4.
Surg Endosc ; 30(9): 4136-49, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26659243

RESUMO

BACKGROUND: Surgical navigation technology directed at fetoscopic procedures is relatively underdeveloped compared with other forms of endoscopy. The narrow fetoscopic field of views and the vast vascular network on the placenta make examination and photocoagulation treatment of twin-to-twin transfusion syndrome challenging. Though ultrasonography is used for intraoperative guidance, its navigational ability is not fully exploited. This work aims to integrate 3D ultrasound imaging and endoscopic vision seamlessly for placental vasculature mapping through a self-contained framework without external navigational devices. METHODS: This is achieved through development, integration, and experimentation of novel navigational modules. Firstly, a framework design that addresses the current limitations based on identified gaps is conceptualized. Secondly, integration of navigational modules including (1) ultrasound-based localization, (2) image alignment, and (3) vision-based tracking to update the scene texture map is implemented. This updated texture map is projected to an ultrasound-constructed 3D model for photorealistic texturing of the 3D scene creating a panoramic view of the moving fetoscope. In addition, a collaborative scheme for the integration of the modular workflow system is proposed to schedule updates in a systematic fashion. Finally, experiments are carried out to evaluate each modular variation and an integrated collaborative scheme of the framework. RESULTS: The modules and the collaborative scheme are evaluated through a series of phantom experiments with controlled trajectories for repeatability. The collaborative framework demonstrated the best accuracy (5.2 % RMS error) compared with all the three single-module variations during the experiment. Validation on an ex vivo monkey placenta shows visual continuity of the freehand fetoscopic panorama. CONCLUSIONS: The proposed developed collaborative framework and the evaluation study of the framework variations provide analytical insights for effective integration of ultrasonography and endoscopy. This contributes to the development of navigation techniques in fetoscopic procedures and can potentially be extended to other applications in intraoperative imaging.


Assuntos
Fetoscopia/métodos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Placenta/irrigação sanguínea , Placenta/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos , Ultrassonografia Pré-Natal/métodos , Endoscópios , Feminino , Humanos , Gravidez
5.
Nagoya J Med Sci ; 78(1): 79-88, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27019529

RESUMO

A rapid and reliable test for detection of complicated appendicitis would be useful when deciding whether emergency surgery is required. We investigated the clinical usefulness of procalcitonin for identifying acute complicated appendicitis. We retrospectively analyzed 63 patients aged ≥15 years who underwent appendectomy without receiving antibiotics before admission and had preoperative data on the plasma procalcitonin level (PCT), body temperature (BT), white blood cell count (WBC), neutrophil / lymphocyte ratio (N/L ratio), and C-reactive protein level (CRP). Patients were classified into 3 groups: group A (inflammatory cell infiltration of the appendix with intact mural architecture), group B (inflammatory cell infiltration with destruction of mural architecture, but without abscess or perforation), and group C (macroscopic abscess and/or perforation). For identifying destruction of mural architecture, the diagnostic accuracy of PCT was similar to that of BT or CRP. However, the diagnostic accuracy of PCT was highest among the five inflammatory indices for identifying abscess and/or perforation, with the positive predictive value of PCT for abscess and/or perforation being higher than that of CRP (73% vs. 48%). Univariate analysis of the predictors of abscess and/or perforation revealed that a plasma PCT level ≥0.46 ng/mL had the highest odds ratio (30.3 [95% confidence interval: 6.5-140.5] versus PCT <0.46 ng/mL). These findings indicate that procalcitonin is a useful marker of acute appendicitis with abscess and/or perforation.


Assuntos
Apendicite , Adolescente , Adulto , Idoso , Biomarcadores , Proteína C-Reativa , Calcitonina , Peptídeo Relacionado com Gene de Calcitonina , Feminino , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Precursores de Proteínas , Estudos Retrospectivos
6.
Circ J ; 79(7): 1504-10, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25818901

RESUMO

BACKGROUND: To determine the feasibility of original aortic valve reconstruction (AVRec) for patients with aortic stenosis (AS), 416 consecutive cases were reviewed. METHODS AND RESULTS: AVRecs for AS were performed for 416 patients from April 2007 through April 2013. All 416 patients were retrospectively reviewed. One hundred and fourteen patients had bicuspid valves and 16 had unicuspid valves. There were 182 men and 234 women. Mean age was 71.2±12.0 years old. On preoperative echocardiography, peak pressure gradient averaged 79.0±33.6 mmHg. Surgical annular diameter was 20.1±2.8 mm. The procedure is based on independent tricuspid replacement by autologous pericardium using original sizing apparatus and template. There was no conversion to prosthetic valve replacement. There were 8 in-hospital mortalities due to non-cardiac cause. On postoperative echocardiography, peak pressure gradient averaged 21.2±10.7 mmHg 1 week after surgery and 14.3±5.0 mmHg 5.5 years after surgery. Four reoperations were done for infective endocarditis. The other 412 patients had less than mild regurgitation. No thrombo-embolic events were recorded. The mean follow-up period was 25.2±17.5 months. Freedom from reoperation was 96.7% with 73-month follow-up. CONCLUSIONS: Medium-term results were excellent. Original AVRec was feasible for the patients with AS. Long-term data will be presented in the future.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos , Pericárdio , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/fisiopatologia , Intervalo Livre de Doença , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Taxa de Sobrevida
8.
Circ J ; 78(5): 1144-51, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24614492

RESUMO

BACKGROUND: This study describes the surgical treatment of bicuspid aortic valve with original aortic valve reconstruction. METHODS AND RESULTS: Aortic valve reconstruction was done in 102 patients with bicuspid aortic valve from April 2007 through September 2011. Thirty-four patients with ascending aortic diameter >45 mm underwent hemi-arch aortic replacement concomitantly. Seventy-seven patients had aortic stenosis, and 25 had aortic regurgitation (AR). Mean age was 63.7±10.0 years old. There were 55 men and 47 women. Harvested pericardium is treated with 0.6% glutaraldehyde solution. The distance between commissures is measured with an original sizing instrument. For bicuspid valve with raphe, the raphe is considered as a commissure in order to measure the distance between each commissure. Without a raphe, we create a new annular margin and commissure using coronary ostium and the sizing instrument as a guide. Then, pericardium is trimmed with original template. Three cusps are sutured independently. The preoperative averaged peak pressure gradient of 71.1±39.0 mmHg was decreased to 16.2±8.8, 13.3±6.0, and 13.9±5.6 mmHg, respectively 1 week, 1 year, and 3 years after operation. AR was trivial. One reoperation was recorded. Mean follow-up was 733 days. There were 5 late mortalities. No thromboembolic event was recorded. CONCLUSIONS: Medium-term results were excellent. Tricuspidization gave good opening and closure of aortic valve with excellent hemodynamics.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Procedimentos Cirúrgicos Cardíacos/métodos , Doenças das Valvas Cardíacas/cirurgia , Pericárdio , Idoso , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/patologia , Estenose da Valva Aórtica/patologia , Doença da Válvula Aórtica Bicúspide , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
9.
Surg Endosc ; 28(11): 3240-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24950723

RESUMO

BACKGROUND: We developed a new ultrahigh-sensitive CMOS camera using a specific sensor that has a wide range of spectral sensitivity characteristics. The objective of this study is to present our updated endoscopic technology that has successfully integrated two innovative functions; ultrasensitive imaging as well as advanced fluorescent viewing. METHODS: Two different experiments were conducted. One was carried out to evaluate the function of the ultrahigh-sensitive camera. The other was to test the availability of the newly developed sensor and its performance as a fluorescence endoscope. In both studies, the distance from the endoscopic tip to the target was varied and those endoscopic images in each setting were taken for further comparison. RESULTS: In the first experiment, the 3-CCD camera failed to display the clear images under low illumination, and the target was hardly seen. In contrast, the CMOS camera was able to display the targets regardless of the camera-target distance under low illumination. Under high illumination, imaging quality given by both cameras was quite alike. In the second experiment as a fluorescence endoscope, the CMOS camera was capable of clearly showing the fluorescent-activated organs. CONCLUSIONS: The ultrahigh sensitivity CMOS HD endoscopic camera is expected to provide us with clear images under low illumination in addition to the fluorescent images under high illumination in the field of laparoscopic surgery.


Assuntos
Aumento da Imagem/instrumentação , Laparoscópios , Laparoscopia/instrumentação , Iluminação , Fotografação/instrumentação , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes
10.
Artigo em Inglês | MEDLINE | ID: mdl-39098025

RESUMO

PURPOSE: Esaxerenone, a mineralocorticoid receptor blocker, attenuates global ischemia-induced myocardial damage and coronary endothelial dysfunction. This study aimed to determine whether esaxerenone exerted cardioprotective effects against cardioplegic arrest in Wistar rat hearts. METHODS: Isolated male Wistar rat hearts aerobically perfused via the Langendorff method for 20 min were randomly allocated to the Control (n = 6; perfused for an additional 10 min and subjected to no treatment) or Esax (n = 6; perfused with 0.1 µmol/L esaxerenone in perfusate for 10 min before ischemia) groups. Hearts in both groups were perfused with St. Thomas' Hospital No. 2 solution (STH2) for 2 min and subjected to 28 min of global ischemia. The recovery of left ventricular developed pressure (LVDP) and total troponin T leakage were measured after reperfusion. RESULTS: The final recovery of LVDP (expressed as a percentage of pre-ischemic value) in the Control and Esax groups was 50.8 ± 3.5% and 62.1 ± 5.6%, respectively (p <0.05, Esax vs. Control). The total troponin T leakage in the Control and Esax groups was 138.8 ± 18.5 ng/g heart wt and 74.3 ± 18.6 ng/g heart wt, respectively (p <0.05, Esax vs. Control). CONCLUSION: The administration of esaxerenone before cardioplegic arrest enhanced the cardioprotective effect exerted by STH2.


Assuntos
Modelos Animais de Doenças , Parada Cardíaca Induzida , Preparação de Coração Isolado , Antagonistas de Receptores de Mineralocorticoides , Traumatismo por Reperfusão Miocárdica , Ratos Wistar , Sulfonas , Troponina T , Função Ventricular Esquerda , Pressão Ventricular , Animais , Masculino , Função Ventricular Esquerda/efeitos dos fármacos , Antagonistas de Receptores de Mineralocorticoides/farmacologia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Troponina T/sangue , Fatores de Tempo , Sulfonas/farmacologia , Pressão Ventricular/efeitos dos fármacos , Recuperação de Função Fisiológica , Miocárdio/metabolismo , Miocárdio/patologia , Soluções Cardioplégicas/farmacologia , Pirróis
11.
Ann Vasc Dis ; 17(3): 283-286, 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39359550

RESUMO

A 43-year-old man diagnosed with a giant retroperitoneal tumor with suspected invasion of the abdominal aorta and inferior vena cava underwent surgery. Complete en bloc tumor resection could be achieved by transection and reconstruction of the abdominal aorta and inferior vena cava. This case highlights the need for aggressive, complete tumor resection when major vessels are invaded. To ensure comprehensive tumor removal, especially in cases requiring manipulation of major vessels, it is imperative to increase the involvement of cardiovascular surgeons in such surgeries. Therefore, widespread promotion of the concept of oncovascular surgery is essential.

12.
Surg Endosc ; 27(5): 1642-7, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23233018

RESUMO

BACKGROUND: During endoscopic surgical procedures, surgeons must manipulate an endoscope inside the body cavity to observe a surgical area while estimating the distance between that area and the surgical instruments by reference to a monitor on which the movement and size of the surgical instruments are displayed in 2-D endoscopic images. Therefore, there is a risk of the endoscope or instruments physically damaging body tissues. To overcome this problem, we developed a Ø5-mm, 3-D endoscope using a single 1/10-inch CCD camera and pneumatic vibration mechanism. METHODS: The 3-D endoscope proposed in this paper consists of an outer and inner sleeve, a 1/10-inch CCD camera attached to its distal end, and a pneumatic vibration mechanism attached to its proximal end. This endoscope can acquire left and right endoscopic images for stereovision in synchrony with the periodical motion generated by the vibration mechanism. We measured the displacement at the proximal and distal end of the 3-D endoscope simultaneously, and evaluated the feasibility of its use in vivo. RESULTS: The displacement at the distal end of the endoscope to which the CCD camera is attached was approximately ±0.25 mm. The timing when the displacement of the CCD camera was at maximal amplitude coincided with the timing when the displacement of its proximal end was at maximal amplitude. In the in vivo experiment, this 3-D endoscope can provide clear 3-D images of the surgical area. CONCLUSIONS: The developed 3-D endoscope that uses a single CCD camera and pneumatic vibration mechanism can successfully visualize internal organs inside the body even though the CCD camera is moved by the vibration. Therefore, the risk of damage to fragile body tissues can be significantly decreased.


Assuntos
Endoscópios , Imageamento Tridimensional , Fotografação/instrumentação , Ar , Conversão Análogo-Digital , Animais , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Complicações Intraoperatórias/prevenção & controle , Suínos , Vibração , Vísceras/anatomia & histologia
13.
Eur J Cardiothorac Surg ; 64(6)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38060261

RESUMO

OBJECTIVES: In myocardial infarction, the addition of mineralocorticoid receptor blockers to standard therapies, such as angiotensin-converting enzyme inhibitors or beta-blockers, reportedly reduces mortality and cardiac events. We investigated whether the non-steroidal mineralocorticoid receptor blocker esaxerenone has cardioprotective effects and its protective mechanisms. METHODS: Isolated rat hearts were Langendorff-perfused (constant pressure, 80 mmHg) with oxygenated Krebs-Henseleit bicarbonate buffer and reperfused for 60 min; afterwards, recovery of function (left ventricular pressure, measured with an intraventricular balloon) and myocardial injury were measured. In a preliminary study, we determined the optimal concentration of esaxerenone required for myocardial protection. Next, esaxerenone was administered in the pre- and post-ischaemic phases to determine the optimal timing of administration. In addition, we assessed coronary flow response to acetylcholine with and without esaxerenone. We examined whether esaxerenone-induced cardioprotection was prevented by targeting putative components in the preconditioning manner (the mitochondrial ATP-sensitive potassium [KATP] channel). RESULTS: Myocardial protection by esaxerenone was observed when esaxerenone was administered before ischaemia but not after ischaemia. The coronary flow response to acetylcholine was significantly better in the esaxerenone group than in the control group. The cardioprotective effect of esaxerenone was eliminated by the mitochondrial KATP channel blocker, 5-hydroxy decanoate. CONCLUSIONS: This study confirmed the myocardial protective effect of the pre-ischaemic administration of esaxerenone. Esaxerenone may contribute to coronary endothelial protection and exert pharmacological preconditioning via the mitochondrial KATP channel.


Assuntos
Infarto do Miocárdio , Traumatismo por Reperfusão Miocárdica , Ratos , Animais , Traumatismo por Reperfusão Miocárdica/tratamento farmacológico , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Acetilcolina/uso terapêutico , Receptores de Mineralocorticoides/uso terapêutico , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/prevenção & controle , Canais KATP
14.
Int J Surg Case Rep ; 112: 108988, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37898007

RESUMO

INTRODUCTION AND IMPORTANCE: The incidence of acquired Gerbode defect has been increasing due to advances in cardiac imaging technology, and some closure methods have been introduced. PRESENTATION OF CASE: A 58-year-old man developed cardiogenic shock due to acute severe aortic valve regurgitation with an acquired Gerbode defect caused by infective endocarditis. Emergency surgery was performed. A large patch with a 0.4 mm extended-polytetrafluoroethylene (e-PTFE) sheet covered with autologous pericardium was used to close the Gerbode defect, and a bioprosthetic valve was used for aortic valve replacement. CLINICAL DISCUSSION: Large patch closure with 0.4 mm e-PTFE sheet and autologous pericardium for fragile Gerbode defect caused by infective endocarditis might be effective with regard to sturdiness, good fitting to the tissue, and excellent resistance to bacteria. CONCLUSION: We encountered a rare case of cardiogenic shock due to acute severe aortic valve regurgitation and acquired Gerbode defect caused by infective endocarditis. In our case, large-patch closure for perforation in a fragile membranous septum was effective.

15.
Ann Vasc Dis ; 15(3): 197-200, 2022 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-36310742

RESUMO

A case of a giant popliteal venous aneurysm that caused massive pulmonary thromboembolism with an arteriovenous fistula draining into the adjacent proximal femoral vein is reported herein. Deep veins in the lower leg were occluded by thrombi. The inlet and outlet orifice inside the aneurysm was closed and aneurysmorraphy was performed. The fistula was retained on the estimation that it would maintain the blood flow and prevent thrombus formation inside the femoral vein. The aneurysm was shrunk, the femoral vein was patent, and the fistula was not observed 1 year later, although it still existed 1 week after the operation.

16.
Surg Endosc ; 25(6): 2029-33, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21136093

RESUMO

BACKGROUND: Endoscopic surgery has become an accepted major type of minimally invasive surgery. However, complications arising from heat generated by sources of endoscopic illumination can include surgical fire or burns, and intense illumination during ob-gyn/fetoscopic surgery might damage fetal ocular development. Fiber-optic bundles for illumination within the endoscope essentially double the outer diameter of the endoscope, which is a major obstacle to miniaturization and decreasing costs. Light cables also decrease the maneuverability of the endoscope METHODS: We developed a novel endoscope with ultralow illumination to visualize dark body cavities and investigated its feasibility in vivo. An adaptor was created to connect a conventional endoscope to an ultrahigh-sensitivity camera developed by the Japan Broadcasting Corporation (NHK) for broadcasting. The ability to visualize rabbit visceral blood vessels in vivo by the new prototype and by a current endoscope under ultralow illumination provided by a standard light source was compared. In addition, the performance of the two endoscopes was compared using only an extracorporeal flashlight without any specific light source placed within body cavities. RESULTS: The new endoscope could visualize the target under ultralow illumination of approximately 100 lx. Very little could be visualized using the current endoscope, whereas the prototype generated clear images of the rabbit blood vessels under both ultralow illumination and extracorporeal illumination provided by a flashlight. CONCLUSIONS: The potential for damage caused by a light source can be minimized using our new endoscope, which results in safer and less invasive procedures. Further studies are under way to develop a nonilluminated endoscope without a light cable or source and to miniaturize the camera to decrease costs and improve the maneuverability of the entire endoscope system.


Assuntos
Endoscópios , Iluminação , Animais , Desenho de Equipamento , Fetoscópios , Masculino , Miniaturização , Modelos Animais , Coelhos , Vísceras/irrigação sanguínea
17.
Pathol Int ; 61(3): 150-5, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21355957

RESUMO

Primary cardiac synovial sarcoma is a rare disease. A 51-year-old man visited our hospital with the chief complaint of palpitations and shortness of breath while exercising. Copious bloody pericardial effusion and a multicystic intrapericardial tumor were detected. A primary cardiac malignant tumor was suspected, an open-chest tumor resection was performed with the objectives of diagnosis and treatment. Histologically, the tumor cells were uniformly spindle-shaped with an ovoid or oval nucleus, they had proliferated in fascicular fashion. In addition myxoid degeneration, a hemangiopericytomatous vascular pattern and pseudorosette formation were seen in some areas of the tumor. Based on the histopathological and immunohistochemical findings and reverse transcription polymerase chain reaction detection of SS18-SSX1 fusion transcripts, a monophasic fibrous type synovial sarcoma was diagnosed. Postoperative radiation therapy was administered and there had been no recurrence 9 months after the surgery.


Assuntos
Neoplasias Cardíacas/patologia , Pericitos/patologia , Sarcoma Sinovial/patologia , Actinas/metabolismo , Angiolipoma/diagnóstico , Antígenos CD34/metabolismo , Biomarcadores Tumorais/metabolismo , Diagnóstico Diferencial , Intervalo Livre de Doença , Neoplasias Cardíacas/metabolismo , Neoplasias Cardíacas/cirurgia , Humanos , Lipoma/diagnóstico , Masculino , Pessoa de Meia-Idade , Pericitos/metabolismo , Radioterapia Adjuvante , Sarcoma Sinovial/metabolismo , Sarcoma Sinovial/cirurgia , Coxa da Perna
19.
Heliyon ; 7(2): e06244, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33665425

RESUMO

The practical application of microscopes using 8K ultra-high definition (UHD) technology is progressing. However, due to insufficiencies in factors such as luminous intensity and stereopsis, it has not been possible to achieve sufficient image quality for close observation of submillimeter order microlymphatic anastomosis using a combination of 8K-UHD cameras with a rigid endoscope. We have improved the quality of microsurgery by the introduction of a new heads up 8K-UHD surgical system. Herein, we show the mechanisms of this next-generation technology that makes optical improvements to the electronic image input data, resolving the initial drawback. We have developed a new 8K-UHD digital microscope system with digital zooming to enable maximum 300X magnification of the surgical field. This system has specific lighting settings for shadows dropped in surgical field to expand the three-dimensional effect while still being a monocular camera. The original mechanism and design enable the increase of the depth of field with optimal angles between the imaging direction and approaching direction towards the surgical field. Assessment during a pre-clinical trial using rats demonstrated that it is possible to perform microlymphatic anastomosis in a heads-up position with a 70-inch 8K-UHD monitor and the 8K-UHD monocular camera system. Performing supermicrosurgery is difficult with conventional surgical microscopes. Our results illustrate the application of this new 8K-UHD microscope system to this new field.

20.
Environ Sci Pollut Res Int ; 28(47): 66901-66913, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34236613

RESUMO

Nylon powders are a type of microplastic (MP) used in personal care products such as cosmetics and sunscreens. To determine the effects of nylon polymers on freshwater microalgae, we investigated the effects of two types of micrometer-sized nylon polymers, i.e., powdered nylon 6 (Ny6-P) and nylon 12 (Ny12), and four other micrometer-sized MPs, i.e., low-density polyethylene, polyethylene terephthalate, polystyrene, and ultra-high-molecular-weight polyethylene, on the microalga Raphidocelis subcapitata. The results showed that Ny6-P inhibited R. subcapitata growth more than the other MPs; R. subcapitata growth was inhibited by 54.2% with 6.25 mg/L Ny6-P compared with the control. Ny6-P in the culture media adhered to R. subcapitata cells electrostatically, which may have disrupted growth and photosynthetic activity. Metabolomic analysis revealed that many metabolites related to the amino acid catabolic pathway and γ-glutamyl cycle were induced, which might trigger responses to avoid starvation and oxidative stress. Our study provides important information on the effects of Ny6-P on algae in freshwater environments.


Assuntos
Plásticos , Poluentes Químicos da Água , Caprolactama/análogos & derivados , Água Doce , Polímeros , Eletricidade Estática
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA