Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Tipo de estudo
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Biomed Environ Sci ; 30(12): 907-912, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29335060

RESUMO

To characterize long-term nonprogressors (LTNPs) and viremia controllers (VCs), infected with HIV-1 through contaminated blood donation or transfusion between 1992 and 1996 in Henan, China. LTNPs and VCs were defined by CD4+T lymphocyte (CD4) count and viral load (VL). Of 29,294 patients infected with HIV-1 via contaminated blood donation or transfusion that had conducted for more than 20 years, 92 were LTNPs/VCs. There were 70 LTNPs (0.24%), 43 VCs (0.15%), and 48 LTNPs+VCs- (0.16%). VCs had a significantly lower CD4 nadir, compared to LTNPs and LTNPs+VCs-, and no significant differences for the highest VL and HIV-1 DNA. Cases P4 and P5 were LTNPs, while their VL reached approximately 4.3 log copies/mL. P6 was a VC, but with CD4 < 500 cells/µL constantly. Data from the LTNPs/VCs cohort provided valuable information, future research is needed.


Assuntos
Doadores de Sangue , Transfusão de Sangue , Infecções por HIV , HIV-1 , Adolescente , Adulto , Contagem de Linfócito CD4 , Linfócitos T CD4-Positivos , Feminino , Infecções por HIV/etiologia , Infecções por HIV/imunologia , Infecções por HIV/virologia , Humanos , Masculino , Pessoa de Meia-Idade , Carga Viral , Viremia/imunologia , Adulto Jovem
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(2): 565-9, 2011 Feb.
Artigo em Zh | MEDLINE | ID: mdl-21510428

RESUMO

A novel refractive index sensor based on one-dimensional photonic crystal non-complete surface defect is introduced and the principle and the method of the sensor are discussed. The experiment system used to detect the refractive index was constructed to get high resolution and high Q-value. The sensor is verified by detecting the dimethyl sulphone solution. The experimental result indicates that this refractive index sensor's sensitivity is 3 025 nm x RIU(-1), and when the resolution of spectrometer is 0.01 nm the resolution of this sensor is 3.3 x 10(-6) RIU. The Q value of this sensor is 260, and the sensor has good linearity in 1.4-1.42 range (the linearity is 0.991 27). It was analyzed how the photonic crystal periodicity and liquid thickness affect the Q value of the sensor. The result proved that this kind of total reflection photonic crystal surface wave sensor is label free, which is similar with SPR sensor, and the sensor has high resolution, high Q-value and has real-time survey characteristic.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA