Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(11)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38893971

RESUMO

Surface treatment of implants facilitates osseointegration, with nanostructured surfaces exhibiting accelerated peri-implant bone regeneration. This study compared bone-to-implant contact (BIC) in implants with hydroxyapatite (HA), sand-blasted and acid-etched (SLA), and SLA with calcium (Ca)-coated (XPEED®) surfaces. Seventy-five disk-shaped grade 4 Ti specimens divided into three groups were prepared, with 16 implants per group tested in New Zealand white rabbits. Surface characterization was performed using X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), digital microscopy, and a contact angle analyzer. Cell viability, proliferation, and adhesion were assessed using MC3T3-E1 cells. Apatite formation was evaluated using modified simulated body fluid (m-SBF) incubation. After 4 weeks of healing, the outcomes reviewed were BIC, bone area (BA), removal torque tests, and histomorphometric evaluation. A microstructure analysis revealed irregular pores across all groups, with the XPEED group exhibiting a nanostructured Ca-coated surface. Surface characterization showed a crystalline CaTiO3 layer on XPEED surfaces, with evenly distributed Ca penetrating the implants. All surfaces provided excellent environments for cell growth. The XPEED and SLA groups showed significantly higher cell density and viability with superior osseointegration than HA (p < 0.05); XPEED exhibited the highest absorbance values. Thus, XPEED surface treatment improved implant performance, biocompatibility, stability, and osseointegration.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38940681

RESUMO

AIM: The aim of this work is to present a new protocol for implant surgical planning which involves the combined use of artificial intelligence (AI) and mixed reality (MR). METHODS: This protocol involves the acquisition of three-dimensional (3D) patient data through intraoral scanning (IOS) and cone beam computed tomography (CBCT). These data are loaded into AI software which automatically segments and aligns the patient's 3D models. These 3D models are loaded into MR software and used for planning implant surgery through holography. The files are then exported and used to design surgical guides via open-source software, which are 3D printed and used to prepare the implant sites through static computer-assisted implant surgery (s-CAIS). The case is finalized prosthetically through a fully digital protocol. The accuracy of implant positioning is verified by comparing the planned position with the actual position of the implants after surgery. RESULTS: As a proof of principle, the present protocol seems to be to be reliable and efficient when used for planning simple cases of s-CAIS in partially edentulous patients. The clinician can plan the implants in an authentic 3D environment without using any radiology-guided surgery software. The precision of implant placement seems clinically acceptable, with minor deviations. CONCLUSIONS: The present study suggests that AI and MR technologies can be successfully used in s-CAIS for an authentic 3D planning. Further clinical studies are needed to validate this protocol.

3.
Materials (Basel) ; 17(10)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38793397

RESUMO

Titanium implants undergo an aging process through surface hydrocarbon deposition, resulting in decreased wettability and bioactivity. Plasma treatment was shown to significantly reduce surface hydrocarbons, thus improving implant hydrophilicity and enhancing the osseointegration process. This study investigates the effect of plasma surface treatment on bone-to-implant contact (BIC) of implants presenting a nanostructured calcium-incorporated surface (XPEED®). Following a Randomized Controlled Trial (RCT) design, patients undergoing implant surgery in the posterior maxilla received additional plasma-treated (n = 7) or -untreated (n = 5) 3.5 × 8 mm implants that were retrieved after a 4-week healing period for histological examination. Histomorphometric analysis showed that plasma-treated implants exhibited a 38.7% BIC rate compared to 22.4% of untreated implants (p = 0.002), indicating enhanced osseointegration potential. Histological images also revealed increased bone formation and active osteoblastic activity around plasma-treated implants when compared to untreated specimens. The findings suggest that plasma treatment improves surface hydrophilicity and biological response, facilitating early bone formation around titanium implants. This study underscores the importance of surface modifications in optimizing implant integration and supports the use of plasma treatment to enhance osseointegration, thereby improving clinical outcomes in implant dentistry and offering benefits for immediate and early loading protocols, particularly in soft bone conditions.

4.
Materials (Basel) ; 17(13)2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38998421

RESUMO

This study aimed to histologically evaluate the effects of XPEED® and SLA surface on the mineral apposition rate (MAR) at 3 and 5 weeks in titanium dental implants placed in human bone. In total, 17 titanium dental implants with XPEED® surface (n = 9) used as test and SLA surface (n = 8) used as control were included in this study. Each patient received four doses of tetracycline 500 mg at 12 h intervals 2 weeks prior to biopsy retrieval. Implant retrieval was performed, and retrieved biopsies were carefully treated for histomorphometric evaluation under epifluorescence microscopy. At 3 and 5 weeks, newly formed bone appeared in direct contact with both types of tested surfaces. At 3 weeks, the MAR value was, respectively, 2.0 (±0.18) µm/day for XPEED® implants and 1.5 (±0.10) µm/day for SLA implants (p = 0.017). At 5 weeks, lower MAR values for both XPEED® and SLA implants were noted, with 1.2 (±0.10) µm/day and 1.1 (±0.10) µm/day, respectively (p = 0.046). The overall evaluation by linear regression analysis for both time and implant surfaces showed a decreased osteoblast activity at 5 weeks compared to 3 weeks (p < 0.005). The results of the present study show that the bone apposition rate occurs faster around implants with XPEED® surface at 3 weeks and 5 weeks of healing. MAR values may support the use of implants with XPEED® surfaces in early loading protocols.

5.
J Dent ; 147: 105095, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38788917

RESUMO

PURPOSE: To report the clinical results obtained with fixed short-span (single crowns [SCs] and fixed partial prostheses [FPPs]) implant-supported hybrid composite restorations fabricated through tilting stereolithography (TSLA). METHODS: This retrospective clinical study included 85 patients who had been restored with 95 fixed short-span implant-supported hybrid composite (Irix Max®, DWS Systems) restorations (70 SCs and 25 FPPs up to three units) fabricated with TSLA. The full-digital model-free workflow was based on intraoral implant scanning, computer-assisted design (CAD) and 3D printing using TSLA (Dfab®, DWS Systems). The primary outcomes were the marginal adaptation, the quality of the occlusal and interproximal contact points, and the chromatic integration of the restorations, assessed independently by two experienced operators (a prosthodontist and a periodontist). A score from 1 to 5 (with 5 as the highest value, 4 for satisfactory quality, 3 for acceptable quality, and 2 and 1 as the lowest values, expressing unsatisfactory quality) was assigned by each operator to each restoration at delivery. The secondary outcomes were the survival and success of the restorations at the 1-year follow-up. The restoration was defined as successful in the absence of any complications throughout the follow-up period. A statistical analysis was conducted. RESULTS: For the quality of the marginal closure and occlusal and interproximal contact points, the 3D-printed hybrid composite restorations scored highly; the aesthetic integration was satisfactory. One year after placement, all restorations survived, with a low incidence (4.2 % overall, 5.7 % SCs) of complications (two abutment screw loosenings, two decementation of the restorations, and one upper portion of the hybrid abutment decemented from the titanium base), for a success rate of 95.8 %. CONCLUSIONS: Within the limits of this study (retrospective design, follow-up limited to 1 year from the delivery, and only cemented restorations included) fixed short-span implant-supported hybrid composite crowns and bridges fabricated through TSLA were clinically precise, presenting a low incidence of complications at 1 year. STATEMENT OF CLINICAL RELEVANCE: The use of TSLA printing technology can open new perspectives for the treatment of small edentulous gaps with definitive implant-supported prosthetic restorations.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Coroas , Prótese Dentária Fixada por Implante , Impressão Tridimensional , Estereolitografia , Humanos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Seguimentos , Adulto , Idoso , Resinas Compostas/química , Planejamento de Prótese Dentária , Adaptação Marginal Dentária , Prótese Parcial Fixa , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA