2.
Clin Implant Dent Relat Res ; 3(3): 166-74, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11799707

RESUMO

BACKGROUND: The Brånemark System Classic is well documented for its successful and predictable results in dental implant rehabilitation. However, the classic two-stage protocol is associated with problems, such as long treatment time and high treatment cost. To overcome these problems, new developments, including early functional loading protocol and Brånemark System Novum, have been introduced by various groups of researchers. In Hong Kong, a protocol has been developed to immediately load the Brånemark System fixtures with a fixed provisional prosthesis. PURPOSE: The goal of this prospective study was to present the Hong Kong Bridge protocol and report the short-term evaluation of this protocol in a group of patients who had undergone dental implant treatment for their edentulous mandibles. MATERIALS AND METHODS: Twenty-seven consecutive patients being treated at the Hong Kong Osseointegration Implant Centre between June 1998 and December 2000 were included in this study. A total of 123 Brånemark System fixtures were installed and regularly followed up for 3 to 30 months. The prosthesis stability and the marginal bone level were regularly evaluated clinically and radiographically, respectively, after the implant surgery. RESULTS: Fifteen of the 27 patients had been followed up for 1 year or longer. Two patients with eight fixtures were withdrawn from the study. Two of the 115 remaining fixtures failed, resulting in an overall implant survival rate of 98.3%. The mean marginal bone change was reported on 49 fixtures that had passed the 1-year review. The mean marginal bone loss was 0.60 mm (p < .05) after 1 year of functional loading. CONCLUSIONS: To load the mandibular Brånemark System fixtures immediately according to the Hong Kong Bridge protocol was a predictable and simple method with good results during this preliminary study period.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Prótese Parcial Fixa , Prótese Parcial Temporária , Mandíbula/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Reabsorção Óssea/diagnóstico por imagem , Protocolos Clínicos , Dente Suporte , Implantação Dentária Endóssea/métodos , Falha de Restauração Dentária , Planejamento de Dentadura , Retenção de Dentadura , Feminino , Seguimentos , Hong Kong , Humanos , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/reabilitação , Arcada Edêntula/cirurgia , Masculino , Mandíbula/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Análise de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA