Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Wound Repair Regen ; 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37753874

RESUMO

Wound management for acute and chronic wounds has become a serious clinical problem worldwide, placing considerable pressure on public health systems. Owing to the high-precision, adjustable pore structure, and repeatable manufacturing process, 3D-printed electrospun fibre (3DP-ESF) has attracted widespread attention for fabricating wound dressing. In addition, in comparison with 2D electrospun fibre membranes fabricated by traditional electrospinning, the 3D structures provide additional guidance on cell behaviour. In this perspective article, we first summarise the basic manufacturing principles and methods to fabricate 3DP-ESF. Then, we discuss the function of 3DP-ESF in manipulating the different stages of wound healing, including anti-bacteria, anti-inflammation, and promotion of cell migration and proliferation, as well as the construction of tissue-engineered scaffolds. In the end, we provide the current challenge faced by 3DP-ESF in the application of skin wound regeneration and its promising future directions.

2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 47(3): 268-271, 2023 May 30.
Artigo em Zh | MEDLINE | ID: mdl-37288626

RESUMO

To comprehensively evaluate the human body's respiratory, circular metabolism and other functions, and to diagnose lung disease, an accurate and reliable pulmonary function test (PFT) is developed. The system is divided into two parts:hardware and software. It realizes the collection of respiratory, pulse oxygen, carbon dioxide, oxygen and other signals, and draws flow-volume curve (FV curve), volume-time curve (VT curve), respiratory waveform, pulse wave, carbon dioxide and oxygen waveform in real time on the upper computer of the PFT system, and conducts signal processing and parameter calculation for each signal. The experimental results prove that the system is safe and reliable, it can accurately measure the basic functions of human body, and provide reliable parameters, and has good application prospects.


Assuntos
Dióxido de Carbono , Oxigênio , Humanos , Testes de Função Respiratória , Frequência Cardíaca
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 47(2): 145-149, 2023 Feb 08.
Artigo em Zh | MEDLINE | ID: mdl-37096466

RESUMO

In order to assess and diagnose lower urinary tract dysfunction in patients and help patients with lower urinary tract rehabilitation training, an accurate and reliable urodynamic monitoring and automatic voiding system was designed. The system realizes the signal acquisition circuit of bladder pressure, abdominal pressure and urine volume based on the pressure sensor of urinary catheter and the load sensor. Meanwhile, the dynamic waveforms of urinary flow rate, bladder pressure and abdominal pressure are drawn in real time on the software of urodynamic monitoring. Signal processing and analysis of each signal are carried out, and the system performance is verified by building a simulation experiment. The experimental results show that the system is stable, reliable, accurate and meets the expected design goals, which can provide support for subsequent engineering design and clinical applications.


Assuntos
Bexiga Urinária , Urodinâmica , Humanos , Micção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA