Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 147
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 386(2): 128-137, 2022 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-34735046

RESUMO

BACKGROUND: Patients with three-vessel coronary artery disease have been found to have better outcomes with coronary-artery bypass grafting (CABG) than with percutaneous coronary intervention (PCI), but studies in which PCI is guided by measurement of fractional flow reserve (FFR) have been lacking. METHODS: In this multicenter, international, noninferiority trial, patients with three-vessel coronary artery disease were randomly assigned to undergo CABG or FFR-guided PCI with current-generation zotarolimus-eluting stents. The primary end point was the occurrence within 1 year of a major adverse cardiac or cerebrovascular event, defined as death from any cause, myocardial infarction, stroke, or repeat revascularization. Noninferiority of FFR-guided PCI to CABG was prespecified as an upper boundary of less than 1.65 for the 95% confidence interval of the hazard ratio. Secondary end points included a composite of death, myocardial infarction, or stroke; safety was also assessed. RESULTS: A total of 1500 patients underwent randomization at 48 centers. Patients assigned to undergo PCI received a mean (±SD) of 3.7±1.9 stents, and those assigned to undergo CABG received 3.4±1.0 distal anastomoses. The 1-year incidence of the composite primary end point was 10.6% among patients randomly assigned to undergo FFR-guided PCI and 6.9% among those assigned to undergo CABG (hazard ratio, 1.5; 95% confidence interval [CI], 1.1 to 2.2), findings that were not consistent with noninferiority of FFR-guided PCI (P = 0.35 for noninferiority). The incidence of death, myocardial infarction, or stroke was 7.3% in the FFR-guided PCI group and 5.2% in the CABG group (hazard ratio, 1.4; 95% CI, 0.9 to 2.1). The incidences of major bleeding, arrhythmia, and acute kidney injury were higher in the CABG group than in the FFR-guided PCI group. CONCLUSIONS: In patients with three-vessel coronary artery disease, FFR-guided PCI was not found to be noninferior to CABG with respect to the incidence of a composite of death, myocardial infarction, stroke, or repeat revascularization at 1 year. (Funded by Medtronic and Abbott Vascular; FAME 3 ClinicalTrials.gov number, NCT02100722.).


Assuntos
Ponte de Artéria Coronária , Estenose Coronária/cirurgia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea/métodos , Idoso , Doenças Cardiovasculares/epidemiologia , Ponte de Artéria Coronária/efeitos adversos , Estenose Coronária/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Reoperação , Stents
2.
Circulation ; 148(12): 950-958, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37602376

RESUMO

BACKGROUND: Previous studies comparing percutaneous coronary intervention (PCI) with coronary artery bypass grafting (CABG) in patients with multivessel coronary disease not involving the left main have shown significantly lower rates of death, myocardial infarction (MI), or stroke after CABG. These studies did not routinely use current-generation drug-eluting stents or fractional flow reserve (FFR) to guide PCI. METHODS: FAME 3 (Fractional Flow Reserve versus Angiography for Multivessel Evaluation) is an investigator-initiated, multicenter, international, randomized trial involving patients with 3-vessel coronary artery disease (not involving the left main coronary artery) in 48 centers worldwide. Patients were randomly assigned to receive FFR-guided PCI using zotarolimus drug-eluting stents or CABG. The prespecified key secondary end point of the trial reported here is the 3-year incidence of the composite of death, MI, or stroke. RESULTS: A total of 1500 patients were randomized to FFR-guided PCI or CABG. Follow-up was achieved in >96% of patients in both groups. There was no difference in the incidence of the composite of death, MI, or stroke after FFR-guided PCI compared with CABG (12.0% versus 9.2%; hazard ratio [HR], 1.3 [95% CI, 0.98-1.83]; P=0.07). The rates of death (4.1% versus 3.9%; HR, 1.0 [95% CI, 0.6-1.7]; P=0.88) and stroke (1.6% versus 2.0%; HR, 0.8 [95% CI, 0.4-1.7]; P=0.56) were not different. MI occurred more frequently after PCI (7.0% versus 4.2%; HR, 1.7 [95% CI, 1.1-2.7]; P=0.02). CONCLUSIONS: At 3-year follow-up, there was no difference in the incidence of the composite of death, MI, or stroke after FFR-guided PCI with current-generation drug-eluting stents compared with CABG. There was a higher incidence of MI after PCI compared with CABG, with no difference in death or stroke. These results provide contemporary data to allow improved shared decision-making between physicians and patients with 3-vessel coronary artery disease. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02100722.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Intervenção Coronária Percutânea , Acidente Vascular Cerebral , Humanos , Doença da Artéria Coronariana/cirurgia , Seguimentos , Intervenção Coronária Percutânea/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
3.
Circulation ; 145(22): 1655-1662, 2022 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-35369704

RESUMO

BACKGROUND: Previous studies have shown that quality of life improves after coronary revascularization more so after coronary artery bypass grafting (CABG) than after percutaneous coronary intervention (PCI). This study aimed to evaluate the effect of fractional flow reserve guidance and current generation, zotarolimus drug-eluting stents on quality of life after PCI compared with CABG. METHODS: The FAME 3 trial (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation) is a multicenter, international trial including 1500 patients with 3-vessel coronary artery disease who were randomly assigned to either CABG or fractional flow reserve-guided PCI. Quality of life was measured using the European Quality of Life-5 Dimensions (EQ-5D) questionnaire at baseline and 1 and 12 months. The Canadian Cardiovascular Class angina grade and working status were assessed at the same time points and at 6 months. The primary objective was to compare EQ-5D summary index at 12 months. Secondary end points included angina grade and work status. RESULTS: The EQ-5D summary index at 12 months did not differ between the PCI and CABG groups (difference, 0.001 [95% CI, -0.016 to 0.017]; P=0.946). The trajectory of EQ-5D during the 12 months differed (P<0.001) between PCI and CABG: at 1 month, EQ-5D was 0.063 (95% CI, 0.047 to 0.079) higher in the PCI group. A similar trajectory was found for the EQ (EuroQol) visual analogue scale. The proportion of patients with Canadian Cardiovascular Class 2 or greater angina at 12 months was 6.2% versus 3.1% (odds ratio, 2.5 [95% CI, 0.96-6.8]), respectively, in the PCI group compared with the CABG group. A greater percentage of younger patients (<65 years old) were working at 12 months in the PCI group compared with the CABG group (68% versus 57%; odds ratio, 3.9 [95% CI, 1.7-8.8]). CONCLUSIONS: In the FAME 3 trial, quality of life after fractional flow reserve-guided PCI with current generation drug-eluting stents compared with CABG was similar at 1 year. The rate of significant angina was low in both groups and not significantly different. The trajectory of improvement in quality of life was significantly better after PCI, as was working status in those <65 years old. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02100722.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Angina Pectoris , Canadá , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Qualidade de Vida , Resultado do Tratamento
4.
Am Heart J ; 222: 30-37, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32007823

RESUMO

BACKGROUND: The safety and efficacy of angiotensin converting enzyme inhibition (ACEI) after heart transplantation (HT) is unknown. This study examined long-term clinical outcomes after ACEI in HT recipients. METHODS: The ACEI after HT study was a prospective, randomized trial that tested the efficacy of ACEI with ramipril after HT. In this study, long-term clinical outcomes were assessed in 91 patients randomized to either ramipril or placebo (median, 5.8 years). The primary endpoint was a composite of death, retransplantation, hospitalization for rejection or heart failure, and coronary revascularization. RESULTS: The primary endpoint occurred in 10 of 45 patients (22.2%) in the ramipril group and in 14 of 46 patients (30.4%) in the placebo group (Hazard ratio (HR), 0.68; 95% CI, 0.29-1.51; P = .34). When the analysis was restricted to comparing patients who remained on a renin-angiotensin system inhibitor beyond 1 year with those who did not, there was a trend to improved outcomes (HR, 0.54; 95% CI, 0.22-1.28, P = .16). There was no significant difference in creatinine, blood urea nitrogen, and potassium at 3 years after randomization. The cumulative incidence of the primary endpoint was significantly higher in patients in whom the index of microcirculatory resistance increased from baseline to 1 year compared with those in whom it did not (39.1 vs 17.4%, HR: 3.36; 95% CI, 1.07-12.7; P = .037). CONCLUSION: The use of ramipril after HT safely lowers blood pressure and is associated with favorable long-term clinical outcomes. Clinical Trial Registration-URL: https://www.clinicaltrials.gov. Unique identifier: NCT01078363.


Assuntos
Rejeição de Enxerto/prevenção & controle , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Ramipril/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Método Duplo-Cego , Feminino , Seguimentos , Rejeição de Enxerto/fisiopatologia , Humanos , Masculino , Microcirculação/efeitos dos fármacos , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 95(6): 1067-1073, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31301219

RESUMO

OBJECTIVES: To assess the long-term safety and efficacy of the Resolute zotarolimus-eluting stent (R-ZES). BACKGROUND: The R-ZES has been associated with low rates of adverse events over short-intermediate term follow-up. However, reliable assessment of the safety and efficacy of any implanted device requires long-term evaluation. METHODS: The RESOLUTE US trial was a prospective, observational study conducted at 116 U.S. sites and enrolled patients with de novo coronary lesions. Patients were followed clinically for 5 years with independent event adjudication and data monitoring. RESULTS: A total of 1,402 patients (1,573 lesions) were enrolled; 34% had diabetes mellitus and 75% had ACC type B2/C lesions. The 5-year rate of target lesion failure (TLF) was 12.3%, target lesion revascularization was 6.5%, target vessel myocardial infarction was 3.2%, and cardiac death was 4.1%. Dual antiplatelet therapy usage was 94% at 1 year and 47% at 5 years, with a 0.1% and 0.5% respective incidence of definite or probable stent thrombosis. The 5-year rate of TLF was 16.9% among patients with diabetes mellitus and 14.7% in patients with at least one small (≤2.5 mm) vessel treated. Covariates independently associated with 5-year TLF in multivariable analysis included diabetes mellitus (odds ratio [OR] 1.89, p < .001), prior coronary artery bypass grafting (OR 2.28, p < .001), prior myocardial infarction (OR 1.85, p = .002), and smaller reference vessel diameter (OR 1.75, p = .004). CONCLUSIONS: Results from the fully adjudicated and monitored RESOLUTE US trial demonstrate long-term 5-year safety and efficacy of the R-ZES stent among a relatively low-risk population of patients, including a 0.5% rate of stent thrombosis at 5 years.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Trombose Coronária/prevenção & controle , Terapia Antiplaquetária Dupla , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Recidiva , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
6.
J Card Fail ; 25(2): 97-104, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30543947

RESUMO

BACKGROUND: Endothelin-1 (ET-1) has been implicated in the development of post-heart transplantation (HT) cardiac allograft vasculopathy (CAV), but has not been well studied in humans. METHODS AND RESULTS: In 90 HT patients, plasma ET-1 was measured within 8 weeks after HT (baseline) via a competitive enzyme-linked immunosorbent assay. Three-dimensional volumetric intravascular ultrasound of the left anterior descending artery was performed at baseline and at 1 year. Accelerated CAV (lumen volume loss) was defined with the 75th percentile as a cutoff. Patients were followed beyond the first year after HT for late death or retransplantation. A receiver operating characteristic (ROC) curve demonstrated that a baseline ET-1 concentration of 1.75 pg/mL provided the best accuracy for diagnosis of accelerated CAV at 1 year (area under the ROC curve 0.69, 95% confidence interval [CI] 0.57-0.82; P = .007). In multivariate logistic regression, a higher baseline ET-1 concentration was independently associated with accelerated CAV (odds ratio [OR] 2.13, 95% CI 1.15-3.94; P = .01); this relationship persisted when ET-1 was dichotomized at 1.75 pg/mL (OR 4.88, 95% CI 1.69-14.10; P = .003). Eighteen deaths occurred during a median follow-up period of 3.99 (interquartile range 2.51-9.95) years. Treated as a continuous variable, baseline ET-1 was not associated with late mortality in multivariate Cox regression (hazard ratio [HR] 1.22, 95% CI 0.72-2.05; P = .44). However, ET-1 >1.75 pg/mL conferred a significantly lower cumulative event-free survival on Kaplan-Meier analysis (P = .047) and was independently associated with late mortality (HR 2.94, 95% CI 1.12-7.72; P = .02). CONCLUSIONS: Elevated ET-1 early after HT is an independent predictor of accelerated CAV and late mortality, suggesting that ET-1 has durable prognostic value in the HT arena.


Assuntos
Doença das Coronárias/sangue , Vasos Coronários/diagnóstico por imagem , Endotelina-1/sangue , Transplante de Coração/efeitos adversos , Complicações Pós-Operatórias/sangue , Aloenxertos , Biomarcadores/sangue , California/epidemiologia , Angiografia Coronária , Doença das Coronárias/diagnóstico , Doença das Coronárias/etiologia , Ensaio de Imunoadsorção Enzimática , Feminino , Seguimentos , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/cirurgia , Transplante de Coração/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Curva ROC , Fatores de Risco , Taxa de Sobrevida/tendências , Ultrassonografia de Intervenção
7.
N Engl J Med ; 372(13): 1204-12, 2015 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-25774645

RESUMO

BACKGROUND: Most trials comparing percutaneous coronary intervention (PCI) with coronary-artery bypass grafting (CABG) have not made use of second-generation drug-eluting stents. METHODS: We conducted a randomized noninferiority trial at 27 centers in East Asia. We planned to randomly assign 1776 patients with multivessel coronary artery disease to PCI with everolimus-eluting stents or to CABG. The primary end point was a composite of death, myocardial infarction, or target-vessel revascularization at 2 years after randomization. Event rates during longer-term follow-up were also compared between groups. RESULTS: After the enrollment of 880 patients (438 patients randomly assigned to the PCI group and 442 randomly assigned to the CABG group), the study was terminated early owing to slow enrollment. At 2 years, the primary end point had occurred in 11.0% of the patients in the PCI group and in 7.9% of those in the CABG group (absolute risk difference, 3.1 percentage points; 95% confidence interval [CI], -0.8 to 6.9; P=0.32 for noninferiority). At longer-term follow-up (median, 4.6 years), the primary end point had occurred in 15.3% of the patients in the PCI group and in 10.6% of those in the CABG group (hazard ratio, 1.47; 95% CI, 1.01 to 2.13; P=0.04). No significant differences were seen between the two groups in the occurrence of a composite safety end point of death, myocardial infarction, or stroke. However, the rates of any repeat revascularization and spontaneous myocardial infarction were significantly higher after PCI than after CABG. CONCLUSIONS: Among patients with multivessel coronary artery disease, the rate of major adverse cardiovascular events was higher among those who had undergone PCI with the use of everolimus-eluting stents than among those who had undergone CABG. (Funded by CardioVascular Research Foundation and others; BEST ClinicalTrials.gov number, NCT00997828.).


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/epidemiologia , Complicações do Diabetes/terapia , Everolimo , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/prevenção & controle , Complicações Pós-Operatórias , Estudos Prospectivos , Sirolimo/administração & dosagem , Acidente Vascular Cerebral/epidemiologia
8.
Circulation ; 133(20): 1945-50, 2016 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-27143679

RESUMO

BACKGROUND: The aim of this study is to determine the prognostic value of invasively assessing coronary physiology early after heart transplantation. METHODS AND RESULTS: Seventy-four cardiac transplant recipients had fractional flow reserve, coronary flow reserve, index of microcirculatory resistance (IMR), and intravascular ultrasound performed down the left anterior descending coronary artery soon after (baseline) and 1 year after heart transplantation. The primary end point was the cumulative survival free of death or retransplantation at a mean follow-up of 4.5±3.5 years. The cumulative event-free survival was significantly lower in patients with a fractional flow reserve <0.90 at baseline (42% versus 79%; P=0.01) or an IMR ≥20 measured 1 year after heart transplantation (39% versus 69%; P=0.03). Patients in whom IMR decreased or did not change from baseline to 1 year had higher event-free survival compared with patients with an increase in IMR (66% versus 36%; P=0.03). Fractional flow reserve <0.90 at baseline (hazard ratio, 0.13; 95% confidence interval, 0.02-0.81; P=0.03), IMR ≥20 at 1 year (hazard ratio, 3.93; 95% confidence interval, 1.08-14.27; P=0.04), and rejection during the first year (hazard ratio, 6.00; 95% confidence interval, 1.56-23.09; P=0.009) were independent predictors of death/retransplantation, whereas intravascular ultrasound parameters were not. CONCLUSIONS: Invasive measures of coronary physiology (fractional flow reserve and IMR) determined early after heart transplantation are significant predictors of late death or retransplantation.


Assuntos
Circulação Coronária/fisiologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Transplante de Coração/mortalidade , Microcirculação/fisiologia , Adulto , Feminino , Seguimentos , Transplante de Coração/tendências , Humanos , Masculino , Microvasos/fisiologia , Pessoa de Meia-Idade , Mortalidade/tendências , Valor Preditivo dos Testes , Estudos Prospectivos
9.
Circulation ; 131(12): 1054-60, 2015 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-25712205

RESUMO

BACKGROUND: More than 20% of patients presenting to the cardiac catheterization laboratory with angina have no angiographic evidence of coronary artery disease. Despite a "normal" angiogram, these patients often have persistent symptoms, recurrent hospitalizations, a poor functional status, and adverse cardiovascular outcomes, without a clear diagnosis. METHODS AND RESULTS: In 139 patients with angina in the absence of obstructive coronary artery disease (no diameter stenosis >50%), endothelial function was assessed; the index of microcirculatory resistance, coronary flow reserve, and fractional flow reserve were measured; and intravascular ultrasound was performed. There were no complications. The average age was 54.0±11.4 years, and 107 (77%) were women. All patients had at least some evidence of atherosclerosis based on an intravascular ultrasound examination of the left anterior descending artery. Endothelial dysfunction (a decrease in luminal diameter of >20% after intracoronary acetylcholine) was present in 61 patients (44%). Microvascular impairment (an index of microcirculatory resistance ≥25) was present in 29 patients (21%). Seven patients (5%) had a fractional flow reserve ≤0.80. A myocardial bridge was present in 70 patients (58%). Overall, only 32 patients (23%) had no coronary explanation for their angina, with normal endothelial function, normal coronary physiological assessment, and no myocardial bridging. CONCLUSIONS: The majority of patients with angina in the absence of obstructive coronary artery disease have occult coronary abnormalities. A comprehensive invasive assessment of these patients at the time of coronary angiography can be performed safely and provides important diagnostic information that may affect treatment and outcomes.


Assuntos
Angina Pectoris/diagnóstico por imagem , Angiografia Coronária/normas , Doença da Artéria Coronariana , Circulação Coronária/fisiologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Ultrassonografia de Intervenção/normas , Adulto , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Ultrassonografia de Intervenção/métodos
11.
Am Heart J ; 170(4): 619-626.e2, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26386784

RESUMO

UNLABELLED: Guidelines recommend coronary artery bypass graft (CABG) surgery over percutaneous coronary intervention (PCI) for the treatment of 3-vessel coronary artery disease (3-VD). The inferior results of PCI demonstrated by previous large randomized trials comparing PCI and CABG might be explained by the use of suboptimal stent technology and by the lack of fractional flow reserve (FFR) guidance of PCI. TRIAL DESIGN: The objective of this investigator-initiated, multicenter, randomized clinical trial is to investigate whether FFR-guided PCI with new-generation stents is noninferior to CABG in patients with 3-VD, not including the left main coronary artery. Eligible patients must have ≥50% coronary stenoses in all 3 major epicardial vessels or major side branches. Patients with a nondominant right coronary artery may be included only if the left anterior descending artery and left circumflex have ≥50% stenoses. Consecutive patients who meet all of the inclusion criteria and none of the exclusion criteria will be randomized in a 1:1 fashion to either CABG or FFR-guided PCI. Coronary artery bypass graft will be performed based on the angiogram as per clinical routine. Patients assigned to FFR-guided PCI will have FFR measured in each diseased vessel and only undergo stenting if the FFR is ≤0.80. The primary end point of the study is a composite of major adverse cardiac and cerebrovascular events, including death, myocardial infarction, repeat coronary revascularization, and stroke at 1 year. Key secondary end point will be a composite of death, myocardial infarction, and stroke at 3-year follow-up. Other secondary end points include the individual adverse events, cost-effectiveness, and quality of life at 2-year, 3-year, with up to 5-year follow-up. CONCLUSION: The FAME 3 study will compare in a multicenter, randomized fashion FFR-guided PCI with contemporary drug-eluting stents to CABG in patients with 3-VD.


Assuntos
Angiografia Coronária , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Intervenção Coronária Percutânea/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Stents Farmacológicos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Adulto Jovem
12.
Catheter Cardiovasc Interv ; 85(3): E70-5, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25331940

RESUMO

OBJECTIVE: To report our initial animal and human experience with a new multi-lumen catheter called MultiCross™ (Roxwood Medical, Inc.) in a porcine coronary model and patients with a chronic total occlusion (CTO). METHODS: Preclinical safety study was done in the coronary vasculature of a porcine model. In a clinical setting, patients with a CTO of a coronary artery (n = 5) were enrolled. After an initial unsuccessful attempt using a conventional guidewire, operators could use the MultiCross system. The primary efficacy endpoint was successful recanalization (technical success) and the primary safety endpoint was serious adverse events through 30 days post-procedure. RESULTS: The MultiCross catheter was used for all patients after failure of the initial attempt with a guidewire. Successful recanalization was achieved in all CTOs attempted (100%). No patients reported any adverse events at 30 days post-procedure. CONCLUSION: In this first-in-man experience, the MultiCross catheter has the potential to enhance crossing of CTOs.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Oclusão Coronária/terapia , Idoso , Animais , Cateterismo Cardíaco/efeitos adversos , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico , Desenho de Equipamento , Feminino , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Modelos Animais , Sistema de Registros , Suínos , Fatores de Tempo , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 85(6): 952-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25689692

RESUMO

BACKGROUND: An increased body mass index (BMI) is associated with a high risk of cardiovascular disease and reduction in life expectancy. However, several studies reported improved clinical outcomes in obese patients treated for cardiovascular diseases. The aim of the present study is to investigate the impact of BMI on long-term clinical outcomes after implantation of zotarolimus eluting stents. METHODS: Individual patient data were pooled from the RESOLUTE Clinical Program comprising five trials worldwide. The study population was sorted according to BMI tertiles and clinical outcomes were evaluated at 2-year follow-up. RESULTS: Data from a total of 5,127 patients receiving the R-ZES were included in the present study. BMI tertiles were as follow: I tertile (≤ 25.95 kg/m(2) -Low or normal weight) 1,727 patients; II tertile (>25.95 ≤ 29.74 kg/m(2) -overweight) 1,695 patients, and III tertile (>29.74 kg/m(2) -obese) 1,705 patients. At 2-years follow-up no difference was found for patients with high BMI (III tertile) compared with patients with normal or low BMI (I tertile) in terms of target lesion failure (I-III tertile, HR [95% CI] = 0.89 [0.69, 1.14], P = 0.341; major adverse cardiac events (I-III tertile, HR [95% CI] = 0.90 [0.72, 1.14], P = 0.389; cardiac death (I-III tertile, HR [95% CI] = 1.20 [0.73, 1.99], P = 0.476); myocardial infarction (I-III tertile, HR [95% CI] = 0.86 [0.55, 1.35], P = 0.509; clinically-driven target lesion revascularization (I-III tertile, HR [95% CI] = 0.75 [0.53, 1.08], P = 0.123; definite or probable stent thrombosis (I-III tertile, HR [95% CI] = 0.98 [0.49, 1.99], P = 0.964. CONCLUSIONS: In the present study, the patients' body mass index was found to have no impact on long-term clinical outcomes after coronary artery interventions.


Assuntos
Angioplastia Coronária com Balão/mortalidade , Índice de Massa Corporal , Reestenose Coronária/epidemiologia , Estenose Coronária/terapia , Stents Farmacológicos , Idoso , Angioplastia Coronária com Balão/métodos , Estudos de Coortes , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Bases de Dados Factuais , Everolimo/farmacologia , Feminino , Seguimentos , Humanos , Internacionalidade , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
15.
JAMA ; 311(10): 1035-45, 2014 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-24618965

RESUMO

IMPORTANCE: Whole-genome sequencing (WGS) is increasingly applied in clinical medicine and is expected to uncover clinically significant findings regardless of sequencing indication. OBJECTIVES: To examine coverage and concordance of clinically relevant genetic variation provided by WGS technologies; to quantitate inherited disease risk and pharmacogenomic findings in WGS data and resources required for their discovery and interpretation; and to evaluate clinical action prompted by WGS findings. DESIGN, SETTING, AND PARTICIPANTS: An exploratory study of 12 adult participants recruited at Stanford University Medical Center who underwent WGS between November 2011 and March 2012. A multidisciplinary team reviewed all potentially reportable genetic findings. Five physicians proposed initial clinical follow-up based on the genetic findings. MAIN OUTCOMES AND MEASURES: Genome coverage and sequencing platform concordance in different categories of genetic disease risk, person-hours spent curating candidate disease-risk variants, interpretation agreement between trained curators and disease genetics databases, burden of inherited disease risk and pharmacogenomic findings, and burden and interrater agreement of proposed clinical follow-up. RESULTS: Depending on sequencing platform, 10% to 19% of inherited disease genes were not covered to accepted standards for single nucleotide variant discovery. Genotype concordance was high for previously described single nucleotide genetic variants (99%-100%) but low for small insertion/deletion variants (53%-59%). Curation of 90 to 127 genetic variants in each participant required a median of 54 minutes (range, 5-223 minutes) per genetic variant, resulted in moderate classification agreement between professionals (Gross κ, 0.52; 95% CI, 0.40-0.64), and reclassified 69% of genetic variants cataloged as disease causing in mutation databases to variants of uncertain or lesser significance. Two to 6 personal disease-risk findings were discovered in each participant, including 1 frameshift deletion in the BRCA1 gene implicated in hereditary breast and ovarian cancer. Physician review of sequencing findings prompted consideration of a median of 1 to 3 initial diagnostic tests and referrals per participant, with fair interrater agreement about the suitability of WGS findings for clinical follow-up (Fleiss κ, 0.24; P < 001). CONCLUSIONS AND RELEVANCE: In this exploratory study of 12 volunteer adults, the use of WGS was associated with incomplete coverage of inherited disease genes, low reproducibility of detection of genetic variation with the highest potential clinical effects, and uncertainty about clinically reportable findings. In certain cases, WGS will identify clinically actionable genetic variants warranting early medical intervention. These issues should be considered when determining the role of WGS in clinical medicine.


Assuntos
Genoma Humano/genética , Mutação , Farmacogenética , Análise de Sequência de DNA/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Genes BRCA1 , Predisposição Genética para Doença , Variação Genética , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
16.
JACC Asia ; 4(4): 292-302, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38660112

RESUMO

Background: Sex-related disparities in clinical outcomes following transcatheter aortic valve replacement (TAVR) and the impact of sex on clinical outcomes after TAVR among different racial groups are undetermined. Objectives: This study assessed whether sex-specific differences in baseline clinical and anatomical characteristics affect clinical outcomes after TAVR and investigated the impact of sex on clinical outcomes among different racial groups. Methods: The TP-TAVR (Trans-Pacific TAVR) registry is a multinational cohort study of patients with severe aortic stenosis who underwent TAVR at 2 major centers in the United States and 1 major center in South Korea. The primary outcome was a composite of death from any cause, stroke, or rehospitalization after 1 year. Results: The incidence of the primary composite outcome was not significantly different between sexes (27.9% in men vs 28% in women; adjusted HR: 0.97; 95% CI: 0.79-1.20). This pattern was consistent in Asian (23.5% vs 23.3%; adjusted HR: 0.99; 95% CI: 0.69-1.41) and non-Asian (30.8% vs 31.6%; adjusted HR: 0.95; 95% CI: 0.72-1.24) cohorts, without a significant interaction between sex and racial group (P for interaction = 0.74). The adjusted risk for all-cause mortality was similar between sexes, regardless of racial group. However, the adjusted risk of stroke was significantly lower in male patients than in female patients, which was more prominent in the non-Asian cohort. Conclusions: Despite significantly different baseline and procedural characteristics, there were no sex-specific differences in the adjusted 1-year rates of primary composite outcomes and all-cause mortality, regardless of different racial groups. (Transpacific TAVR registry [TP-TAVR]; NCT03826264).

18.
Catheter Cardiovasc Interv ; 82(3): E192-9, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-23412754

RESUMO

BACKGROUND: Frequency-domain optical coherence tomography (FD-OCT) is an intravascular imaging technique now available in the United States. However, the importance of level of training required for analysis using intravascular ultrasound (IVUS) and FD-OCT is unclear. The aim of this study was to evaluate inter- and intra-observer variability between expert and beginner analysts interpreting IVUS and FD-OCT images. METHODS AND RESULTS: Two independent expert analysts and two independent beginner analysts evaluated a total of 226 ± 2 stent cross-sections with IVUS and 232 ± 2 stent cross-sections with FD-OCT in 14 patients after stenting. Inter- and intra-observer variability for determining stent volume index (VI), as well as identifying incomplete stent apposition and dissection were assessed. The inter- and intra-observer variability of stent VI was minimal for both beginner and expert analysts regardless of imaging technology (random variability: 0.38 vs. 0.05 mm(3) /mm for IVUS, 0.26 vs. 0.08 mm(3) /mm for FD-OCT). Although qualitative IVUS analysis at the patient level revealed no significant difference between beginners and experts, this was not the case for FD-OCT. The number of overall qualitative findings noted by beginner and expert analysts were more variable (overestimated or underestimated) with FD-OCT. CONCLUSION: Despite varying levels of training, the increased resolution of FD-OCT compared to IVUS provides better detection and less variability in quantitative image analysis. On the contrary, this increased resolution not only increases the rate but also the variability of detection of qualitative image analysis, especially for beginner analysts.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Idoso , Competência Clínica , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intervenção Coronária Percutânea/instrumentação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Stents , Resultado do Tratamento
19.
JACC Case Rep ; 23: 101980, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37954949

RESUMO

We present the case of a 66-year-old woman who developed severe mitral regurgitation from rupture of the anterior mitral valve leaflet following percutaneous balloon mitral valvuloplasty. Emergency transcatheter mitral valve repair was used to reduce the severity of mitral regurgitation and facilitate definitive surgical treatment. (Level of Difficulty: Advanced.).

20.
Cardiovasc Revasc Med ; 51: 31-37, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36740551

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat younger, lower-risk patients with bicuspid aortic valve (BAV). Patient-specific computer simulation may identify patients at risk for developing paravalvular regurgitation (PVR) and major conduction disturbance. Only limited prospective experience of this technology exist. We wished to describe our ongoing experience with patient-specific computer simulation. METHODS: Patients who were referred for consideration of TAVR with a self-expanding transcatheter heart valve (THV) and had BAV identified on pre-procedural cardiac computed tomography imaging underwent patient-specific computer simulation. The computer simulations were reviewed by the Heart Team and used to guide surgical or transcatheter treatment approaches and to aid in THV sizing and positioning. Clinical outcomes were recorded. RESULTS: Between May 2019 and May 2021, 16 patients with BAV were referred for consideration of TAVR with a self-expanding THV. Sievers Type 1 morphology was present in 15 patients and Type 0 in the remaining patient. Two patients were predicted to develop moderate-to-severe PVR with a TAVR procedure and these patients underwent successful surgical aortic valve replacement. In the remaining 14 patients, computer simulation was used to optimize THV sizing and positioning to minimise PVR and conduction disturbance. One patient with a low valve implantation depth developed moderate PVR and this complication was correctly predicted by the computer simulations. No patient required insertion of a new permanent pacemaker. CONCLUSION: Patient-specific computer simulation may be used to guide the most appropriate treatment modality for patients with BAV. The usage of computer simulation to guide THV sizing and positioning was associated with favourable clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Doença da Válvula Aórtica Bicúspide/etiologia , Doença da Válvula Aórtica Bicúspide/cirurgia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Simulação por Computador , Estudos Prospectivos , Tomografia Computadorizada Multidetectores , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA