Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 145(10): 742-753, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-34913361

RESUMO

BACKGROUND: Regulatory authorities of most industrialized countries recommend 6 months of private driving restriction after implantation of a secondary prevention implantable cardioverter-defibrillator (ICD). These driving restrictions result in significant inconvenience and social implications. This study aimed to assess the incidence rate of appropriate device therapies in contemporary recipients of a secondary prevention ICD. METHODS: This retrospective study at 3 Canadian tertiary care centers enrolled consecutive patients with new secondary prevention ICD implants between 2016 and 2020. RESULTS: For a median of 760 days (324, 1190 days), 721 patients were followed up. The risk of recurrent ventricular arrhythmia was highest during the first 3 months after device insertion (34.4%) and decreased over time (10.6% between 3 and 6 months, 11.7% between 6 and 12 months). The corresponding incidence rate per 100 patient-days was 0.48 (95% CI, 0.35-0.64) at 90 days, 0.28 (95% CI, 0.17-0.45) at 180 days, and 0.21 (95% CI, 0.13-0.33) between 181 and 365 days after ICD insertion (P<0.001). The cumulative incidence of arrhythmic syncope resulting in sudden cardiac incapacitation was 1.8% within the first 90 days and subsequently dropped to 0.4% between 91 and 180 days (P<0.001) after ICD insertion. CONCLUSIONS: The incidence rate of appropriate therapies resulting in sudden cardiac incapacitation in contemporary recipients of a secondary prevention ICD is much lower than previously reported and declines significantly after the first 3 months. Lowering driving restrictions to 3 months after the index cardiac event seems safe, and revision of existing guidelines should be considered in countries still adhering to a 6-month period. Existing restrictions for private driving after implantation of a secondary prevention ICD should be reconsidered.


Assuntos
Desfibriladores Implantáveis , Canadá , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Prevenção Primária/métodos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
2.
Europace ; 25(2): 400-407, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36164922

RESUMO

AIMS: Same-day discharge is increasingly common after catheter ablation for atrial fibrillation (AF). However, the impact of same-day discharge on healthcare utilization after ablation and whether this differs by ablation modality remains uncertain. We examined the safety, efficacy, and subsequent healthcare utilization of a same-day discharge protocol for AF ablation, including radiofrequency (RF) and cryoballoon ablation, in a contemporary cohort. METHODS AND RESULTS: All consecutive patients for whom full healthcare utilization data were available at two centres and who underwent AF ablation from 2018 to 2019 were included. Same-day discharge was the default strategy for all patients. The efficacy and safety outcomes were proportions of same-day discharge and readmission/emergency room (ER) visits, and post-discharge complications, respectively. Of the 421 patients who underwent AF ablation (mean 63.3 ± 10.2 years, 33% female), 90.5% (381/421) achieved same-day discharge with no difference between RF and cryoballoon ablation (89.8 vs. 95.1%, adjusted P = 0.327). Readmission ≤30 days occurred in 4.8%, with ER visits ≤30 days seen in 26.1% with no difference between ablation modalities (P = 0.634). Patients admitted overnight were more likely to present to the ER (40.0 vs. 24.7% with same-day discharge, P = 0.036). The overall post-discharge complication rate was low at 4/421 (1.0%), with no difference between ablation modality (P = 0.324) and admission/same-day discharge (P = 0.485). CONCLUSION: Same-day discharge can be achieved in a majority of patients undergoing RF or cryoballoon ablation for AF. Healthcare utilization, particularly ER visits, remains high after AF ablation, regardless of ablation modality or same-day discharge.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Feminino , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Alta do Paciente , Assistência ao Convalescente , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva , Veias Pulmonares/cirurgia
3.
Pacing Clin Electrophysiol ; 46(2): 138-143, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36514201

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) using radiofrequency catheter ablation is a widely accepted therapy for drug-refractory atrial fibrillation patients. Elimination of the negative component of the local unipolar electrogram (UEGM) during PVI is a marker of transmural lesion formation. The ablation index (AI) can predict the quality of ablation lesion. Combining these two parameters could make PVI safer and efficient. The purpose of this pilot study was to examine the correlation between UEGM modification characteristics of the different target areas of left atrium and the associated AI values during PVI. METHODS: We analyzed 10 patients who underwent PVI using radiofrequency energy. The local electrophysiological properties and ablation parameters of 15 designated areas of interest in the left atria targeted by radiofrequency catheter ablation were collected. RESULTS: Out of the 10 patients, six were men (mean age 66 years) and 80% had paroxysmal AF. The mean time to achieve the UEGM modification in the posterior wall was shorter than that of the anterior wall (8.9 seconds vs. 11.1 s, respectively). The UEGM modification for every lesion was achieved at significantly lower AI values than conventional AIs (p < .001). CONCLUSION: During PVI, the AIs deduced according to the local UEGM modification are markedly shorter than those generally recommended AIs in contemporary practice. This indicates that conventionally recommended AIs could be safely reduced while ensuring the efficacy and quality of radiofrequency ablation during PVI. This approach would probably reduce to risk of collateral thermal injuries.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Idoso , Feminino , Projetos Piloto , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Átrios do Coração , Resultado do Tratamento , Recidiva
4.
J Cardiovasc Electrophysiol ; 32(8): 2246-2253, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34216056

RESUMO

INTRODUCTION: The relative effectiveness of medical therapy compared with a conservative approach of monitoring in patients with idiopathic frequent premature ventricular complexes (PVCs) is uncertain. We evaluated the effectiveness of medical versus conservative therapy for frequent PVCs. METHODS: Patients with frequent PVCs (≥5%) were prospectively enrolled in this cohort study between 2016 and 2020. In patients with normal cardiac function and no structural heart disease, those receiving medical therapy were compared with controls without therapy. Patients were followed longitudinally for change in PVC burden and with serial echocardiography. RESULTS: Overall, 120 patients met inclusion criteria (mean: 56.5 ± 14.6 years, 54.2% female) with 53 on beta-blockers or calcium channel blockers (BBs/CCBs), 27 on Class I or III antiarrhythmic drugs (AADs), and 40 patients treated conservatively. Median initial PVC burden ranged from 15.5% to 20.6%. The median relative reduction of PVCs was 32.7%, 30.5%, and 81.3%, in the conservative therapy, BBs/CCBs, and AADs cohorts, respectively. AADs had greater PVC reduction compared with BBs/CCBs (p = 0.017) and conservative therapy (p = 0.045). PVC reduction to <1% was comparable across groups at 35.0%, 17.0%, 33.3%, respectively. Four patients (4/120, 3.3%) developed left ventricular dysfunction. Rates of adverse drug reactions and medication discontinuation were similar between groups, with no serious adverse events noted. CONCLUSION: In patients with idiopathic frequent PVCs, BB, and CCB have limited effectiveness in PVC reduction. Class I and III AADs have superior effectiveness for medical therapy in symptomatic patients, but only achieved complete PVC resolution suppression in one-third of patients.


Assuntos
Disfunção Ventricular Esquerda , Complexos Ventriculares Prematuros , Antiarrítmicos/efeitos adversos , Estudos de Coortes , Ecocardiografia , Feminino , Humanos , Masculino , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/tratamento farmacológico
5.
J Cardiovasc Electrophysiol ; 26(12): 1340-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26471861

RESUMO

INTRODUCTION: Medtronic's Lead Integrity Alert (LIA) software algorithm is useful for detecting abnormal parameters across various ICD-lead families. However, its utility in the assessment of the Biotronik Linox™ family of high-voltage (HV) leads is unknown. METHODS: We conducted a retrospective cohort study to assess the performance of the LIA algorithm to detect abnormalities and lead failure in Linox ICD-leads. All LIA-enabled Medtronic devices connected to an active Linox lead were included. The alerts were adjudicated by 2 blinded electrophysiologists and correlated with clinical data. RESULTS: Between 2008 and 2012, data from 208 patients with 564 patient-years of follow-up were available for analysis. The median follow-up duration was 32 (IQR 21-41 months). Twenty-one LIA triggers were noted in 20 different patients. The median delay until a positive LIA was 32 months (IQR 21-41 months) postimplant with a 5-year lead survival free from LIA of 76%. Ninety-five percent (19/20) LIA alerts were true lead failures. The most common LIA triggers were short V-V intervals (85%) and nonsustained ventricular tachycardia (85%). Abrupt changes of the ICD-lead impedance occurred in 5/20 triggers. Inappropriate ICD-shocks were strongly associated with a positive LIA (30% vs. 7.4%; P = 0.006). Of the explanted Linox leads 53% had visible abnormalities. The sensitivity, specificity, and positive predictive value for lead failure in the presence of a LIA trigger were 87%, 99.5%, and 95.2%, respectively. CONCLUSIONS: A positive LIA trigger in Biotronik Linox ICD-leads is highly predictive of lead failure. LIA is useful in ongoing surveillance of lead performance.


Assuntos
Algoritmos , Desfibriladores Implantáveis , Taquicardia Ventricular/terapia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Estudos de Coortes , Morte Súbita Cardíaca/prevenção & controle , Intervalo Livre de Doença , Eletrocardiografia , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Falha de Tratamento
6.
JACC Clin Electrophysiol ; 8(9): 1122-1132, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36137717

RESUMO

BACKGROUND: The role of cardiac magnetic resonance (CMR) in the evaluation and management of patients with frequent premature ventricular complexes (PVCs) of unknown etiology remains unclear. OBJECTIVES: This study evaluated the prevalence and prognostic significance of myocardial abnormalities detected with CMR among patients with frequent PVCs and no known structural heart disease. METHODS: This prospective cohort study included consecutive patients with frequent PVCs and a negative initial diagnostic work-up who underwent CMR with late gadolinium enhancement imaging. The clinical outcome was a composite of mortality, ventricular fibrillation, sustained ventricular tachycardia, or reduction in left ventricular ejection fraction of ≥10%. RESULTS: A total of 255 patients were included, of whom 35 (13.7%) had evidence of myocardial abnormality on CMR. Age ≥60 years (odds ratio [OR]: 6.96; 95% CI: 1.30-37.18), multifocal PVCs (OR: 10.90; 95% CI: 3.21-36.97), and non-outflow tract left ventricular PVC origin (OR: 3.00; 95% CI: 1.00-8.95) were independently associated with the presence of a myocardial abnormality on CMR. After a median follow-up of 36 months, the composite outcome occurred in 15 (5.9%) patients. The presence of a myocardial abnormality on CMR was independently associated with the composite outcome (HR: 4.35; 95% CI: 1.34-14.15; P = 0.014). CONCLUSIONS: One in 7 patients with frequent PVCs with no known structural heart disease had myocardial abnormality detected on CMR, and these abnormalities were associated with adverse clinical outcomes. These findings highlight the important role of CMR in the evaluation of patients with frequent PVCs.


Assuntos
Função Ventricular Esquerda , Complexos Ventriculares Prematuros , Humanos , Pessoa de Meia-Idade , Meios de Contraste , Gadolínio , Espectroscopia de Ressonância Magnética , Estudos Prospectivos , Volume Sistólico , Complexos Ventriculares Prematuros/diagnóstico
7.
Heart Rhythm O2 ; 2(1): 46-52, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34113904

RESUMO

BACKGROUND: Rate control medications are foundational in the management of persistent atrial fibrillation (AF). There are no guidelines for adjusting these medications prior to elective direct-current cardioversion (DCCV). OBJECTIVE: To derive and validate a preprocedural medication adjustment protocol that maintains peri-DCCV rate control and minimizes risk of postconversion bradycardia, pauses, need for pacing, and cardiopulmonary resuscitation (CPR). METHODS: Consecutive patients with persistent AF awaiting elective DCCV across 2 hospitals were screened for inclusion into derivation, validation, and control cohorts. In the derivation cohort, each patient taking an atrioventricular (AV) nodal blocker had medications adjusted based on heart rate (HR) 2 days before DCCV, and the magnitude of dose adjustment was compared with peri-DCCV HR. The adjustment protocol that achieved the highest percentage of optimal peri-DCCV rate control was tested prospectively in the validation cohort and compared to a standard-of-care control group. RESULTS: The optimal protocol from the derivation cohort (n = 71), based on the 2-day pre-DCCV HR, was to (1) CONTINUE AV nodal blocker for HR ≥ 100 beats per minute (bpm), (2) reduce dose by ONE increment when 80-99 bpm, (3) reduce dose by TWO increments when 60-79 bpm, and (4) HOLD when <60 bpm. In the prospective validation cohort (n = 106), this protocol improved peri-DCCV rate control (82% vs 62%, P < .001) compared to current standard of care (n = 107). There were no conversion pauses ≥5 seconds, need for pacing, or CPR post-DCCV. CONCLUSION: This simple preprocedural medication adjustment protocol provides an effective strategy of optimizing peri-DCCV rate control in patients with AF.

9.
Heart ; 106(22): 1732-1739, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32690622

RESUMO

OBJECTIVE: Despite the widespread and increasing use of ambulatory electrocardiography (ECG), there is no consensus on reference ranges for ambulatory electrocardiogram parameters to guide interpretation. We sought to determine population distribution-based reference ranges for parameters measured during ambulatory electrocardiogram in healthy adults, based on existing literature. METHODS: We searched multiple databases from 1950 to 2020. Articles reporting original data from ≥24-hour ambulatory electrocardiogram monitoring in healthy adults were included. Data extraction and synthesis were performed according to Meta-analysis of Observational Studies in Epidemiology guidelines. The prevalence/mean and SD for common parameters (sinus pauses, conduction abnormalities and ectopy) were extracted by age group (18-39, 40-59, 60-79 and 80+ years). RESULTS: We identified 33 studies involving 6466 patients. Sinus pauses of >3 s were rare (pooled prevalence <1%) across all ages. Supraventricular ectopy of >1000/24 hours increased with age, from 0% (95% CI 0% to 0%) in those aged 18-39 years to 6% (95% CI 0% to 17%) in those aged 60-79 years. Episodes of supraventricular tachycardia increased from 3% (95% CI 1% to 6%) in those aged 18-39 years to 28% (95% CI 9% to 52%) in those aged 60-79 years. Ventricular ectopy of >1000/24 hours also increased with age, from 1% (95% CI 0% to 2%) in those aged 18-39 years to 5% (95% CI 1% to 10%) in those aged 60-79 years. Episodes of non-sustained ventricular tachycardia ranged from 0% (95% CI 0% to 1%) in those aged 18-39 years to 2% (95% CI 0% to 5%) in those aged 60-79 years. CONCLUSION: Despite the limitations of existing published data, this meta-analysis provides evidence-based reference ranges for ambulatory electrocardiogram parameters and highlights significant age-dependent differences that should be taken into account during interpretation.


Assuntos
Eletrocardiografia Ambulatorial/métodos , Frequência Cardíaca/fisiologia , Complexos Ventriculares Prematuros/diagnóstico , Humanos , Valores de Referência , Complexos Ventriculares Prematuros/fisiopatologia
10.
J Interv Card Electrophysiol ; 57(3): 417-424, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30701358

RESUMO

PURPOSE: The purpose of this study was to evaluate the impact of steerable sheaths on multiple contact force parameters during atrial fibrillation (AF) ablation. Steerable sheaths are commonly used during AF ablation, at an additional cost to standard fixed-curve sheaths. However, there is little data on their incremental value in the era of contact force-guided radiofrequency ablation. METHODS: This multi-center cohort study included consecutive patients undergoing index pulmonary vein (PV) isolation with a force-sensing catheter. Operators employed either only steerable or only fixed-curve sheaths. Operators targeted a force of 10-40 g for each ablation lesion. Automated ablation lesion assessment software with standardized settings was employed. RESULTS: Of 85 subjects, 52 and 33 underwent ablation with steerable and fixed-curve sheaths, respectively. The steerable sheath group showed significantly higher average and maximum forces, but predominantly for the right PVs. The proportion of lesions with ≥ 10% of time with less than 10 g of force was lower in the steerable sheath group (adjusted odds ratio 0.56, steerable vs. fixed; 95% confidence interval 0.35, 0.89, p = 0.01). Improved stability was seen in the posterior aspect of both PV pairs. The proportion of RF time-in-target (the proportion of RF time meeting lesion criteria) was not different between the two groups (p = 0.176). CONCLUSIONS: Even with contemporary contact force targets, steerable sheath use in AF ablation is associated with better average and maximum contact force and increased stability in comparison to fixed-curve sheaths.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Mapeamento Epicárdico , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Estudos Retrospectivos
11.
JACC Clin Electrophysiol ; 6(6): 609-619, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32553209

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the efficacy, health care utilization, and safety of a same-day discharge protocol. BACKGROUND: Catheter ablation of atrial fibrillation (AF) is the most common ablation performed. Increasing volumes of AF ablation are placing demands on hospital resources. In response, our institutions developed a same-day discharge protocol for AF ablation. METHODS: This was a multicenter cohort study of all patients undergoing AF ablation from 2010 to 2014 at 2 major centers. The primary efficacy outcome was the proportion of successful same-day discharges. The primary health care utilization outcome was 30-day hospital readmission for any reason. The primary safety outcome was a composite of 30-day death, stroke/transient ischemic attack or embolism, or bleeding requiring hospitalization. RESULTS: A total of 3,054 patients underwent AF ablation from 2010 to 2014 and met inclusion criteria. Same-day discharge was achieved in 79.2% (2,418 of 3,054). Hospital readmission at 30 days was 7.7% for the same-day discharge group, 10.2% for those who remained in the hospital overnight without complications (p = 0.055 for comparison with same-day discharge), and 19.5% (p < 0.001) for those who remained in the hospital with procedural complications (7.7%). Complication rates from discharge to 30 days (excluding immediate procedural complications) were 0.37% for the same-day discharge group, 0.36% (p = 0.999) for those kept overnight without complications, and 2.5% (p = 0.044) for those with initial procedural complications. CONCLUSIONS: Same-day discharge after AF ablation is feasible in the majority of patients with use of a standardized protocol. This approach was not associated with higher hospital readmission or complication rates after discharge.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Estudos de Coortes , Humanos , Alta do Paciente , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento
12.
Can J Cardiol ; 36(8): 1269-1277, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32474110

RESUMO

BACKGROUND: Current guidelines recommend 4 weeks of private driving restriction after implantation of a primary-prevention implantable cardioverter-defibrillator (ICD). These driving restrictions result in significant inconvenience and social implications. Advances in medical treatment and ICD programming have lowered the overall rate of device therapies. The objective of this study was to assess the incidence of ICD therapies at 30, 60, and 180 days after implantation. METHODS: Driving Restrictions and Early Arrhythmias in Patients Receiving a Primary-Prevention Implantable Cardioverter-Defibrillator (DREAM-ICD) was a retrospective cohort study conducted at 2 Canadian university centres enrolling patients with new implantation of a primary-prevention ICD. Device programming was standardised according to current guidelines. A total of 803 patients were enrolled. RESULTS: The cumulative rates of appropriate ICD therapies at 30, 60, and 180 days were 0.12%, 0.50%, and 0.75%, respectively. There was no syncope during the first 6 months. The median duration to the first appropriate ICD therapy was 208 (range 23-1109) days after implantation. The rate of inappropriate ICD therapies at 30 days was only 0.2%. Overall, < 13.6% of all appropriate ICD therapies occurred within the first 6 months after implantation. CONCLUSIONS: The rate of appropriate ICD therapies within the first 30 days after device insertion is extremely low in contemporary primary prevention cohorts with guideline-concordant device programming. There was no increased risk for ventricular arrhythmia early after ICD insertion. The results of DREAM-ICD suggest the need for a revision of the existing driving restrictions for primary-prevention ICD recipients.


Assuntos
Arritmias Cardíacas/prevenção & controle , Condução de Veículo , Desfibriladores Implantáveis , Cardioversão Elétrica/métodos , Prevenção Primária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/epidemiologia , Canadá/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Adulto Jovem
13.
Heart ; 105(18): 1408-1413, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31142596

RESUMO

OBJECTIVE: The natural history of frequent premature ventricular complexes (PVCs) in association with preserved left ventricular ejection fraction (LVEF) is uncertain. The optimal management of this population is thus undefined. We studied the outcomes of untreated patients with frequent PVCs and preserved LVEF. METHODS: This cohort study prospectively evaluated consecutive patients from 2012 to 2017, with asymptomatic or minimally symptomatic frequent idiopathic PVCs (≥5% PVCs in 24 hours; normal LVEF; no cause identified on comprehensive evaluation). No suppressive therapy (ablation or antiarrhythmic drugs) were used and patients were followed with serial ambulatory ECG monitoring and echocardiography. The primary arrhythmic outcome was reduction in PVC burden to <1% on serial ambulatory monitoring. The primary echocardiographic outcome was a reduction of LVEF to <50%. RESULTS: One hundred patients met inclusion criteria (mean age 51.8 years, 57% female) with a median PVC burden of 18.4%. Reduction to <1% PVCs occurred in 44 of 100 patients (44.0%) at a median of 15.4 months (range 2.6 to 64.3). Recurrence was uncommon (4/44, 9.1%). Four patients (4.3%) with a persistently elevated PVC burden developed left ventricular dysfunction (LVEF <50%) during the follow-up period at a range of 53-71 months. The initial PVC burden did not predict subsequent resolution (HR 1.00(0.97, 1.03); p=0.86). CONCLUSIONS: A strategy of active surveillance is appropriate for the majority of patients with frequent idiopathic PVCs in association with preserved LVEF, owing to the low risk of developing left ventricular systolic dysfunction and the high rate of spontaneous resolution.


Assuntos
Frequência Cardíaca , Volume Sistólico , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/fisiopatologia , Adolescente , Adulto , Idoso , Doenças Assintomáticas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Recidiva , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Complexos Ventriculares Prematuros/complicações , Complexos Ventriculares Prematuros/diagnóstico , Adulto Jovem
14.
JACC Clin Electrophysiol ; 5(4): 504-512, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-31000106

RESUMO

OBJECTIVES: The authors studied the response rates and relative sensitivity of the most common agents used in the sodium-channel blocker (SCB) challenge. BACKGROUND: A type 1 Brugada electrocardiographic pattern precipitated by an SCB challenge confers a diagnosis of Brugada syndrome. METHODS: Patients undergoing an SCB challenge were prospectively enrolled across Canada and the United Kingdom. Patients with no prior cardiac arrest and family histories of sudden cardiac death or Brugada syndrome were included. RESULTS: Four hundred twenty-five subjects underwent SCB challenge (ajmaline, n = 331 [78%]; procainamide, n = 94 [22%]), with a mean age of 39 ± 15 years (54% men). Baseline non-type 1 Brugada ST-segment elevation was present in 10%. A total of 154 patients (36%) underwent signal-averaged electrocardiography, with 41% having late potentials. Positive results were seen more often with ajmaline than procainamide infusion (26% vs. 4%, p < 0.001). On multivariate analysis, baseline non-type 1 Brugada ST-segment elevation (odds ratio [OR]: 6.92; 95% confidence interval [CI]: 3.15 to 15.2; p < 0.001) and ajmaline use (OR: 8.76; 95% CI: 2.62 to 29.2; p < 0.001) were independent predictors of positive results to SCB challenge. In the subgroup undergoing signal-averaged electrocardiography, non-type 1 Brugada ST-segment elevation (OR: 9.28; 95% CI: 2.22 to 38.8; p = 0.002), late potentials on signal-averaged electrocardiography (OR: 4.32; 95% CI: 1.50 to 12.5; p = 0.007), and ajmaline use (OR: 12.0; 95% CI: 2.45 to 59.1; p = 0.002) were strong predictors of SCB outcome. CONCLUSIONS: The outcome of SCB challenge was significantly affected by the drug used, with ajmaline more likely to provoke a type 1 Brugada electrocardiographic pattern compared with procainamide. Patients undergoing SCB challenge may have contrasting results depending on the drug used, with potential clinical, psychosocial, and socioeconomic implications.


Assuntos
Ajmalina/farmacologia , Síndrome de Brugada/diagnóstico , Eletrocardiografia/efeitos dos fármacos , Procainamida/farmacologia , Bloqueadores do Canal de Sódio Disparado por Voltagem/farmacologia , Adulto , Síndrome de Brugada/fisiopatologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
16.
Heart Rhythm ; 13(10): 1964-70, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27321245

RESUMO

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a progressive disease characterized by replacement of normal myocardium by fibrofatty tissue. The right ventricular (RV) apex is the typical target for implantable cardioverter-defibrillator (ICD) lead placement, raising concerns for suboptimal lead performance in medium- to long-term follow-up. OBJECTIVE: The purpose of this study was to determine whether placement of ICD leads at the RV apex was associated with performance deterioration of medium-term leads in ARVC patients compared to non-ARVC patients. METHODS: In this multicenter, retrospective, case-control study, ICD lead performance measures of R-wave, impedance, and pacing thresholds were compared at baseline and between 1-year and 5-year postimplantation follow-up using mixed-effect models adjusted for age and sex. RESULTS: One hundred one ARVC patients (49 women, age 50.6 ± 14.5 years) were compared to 56 control patients (37 women, age 48.2 ± 14.2 years). The mean difference in R wave between years 1 and 2 was -0.85 mV (P = .16) compared to a mean difference at years 5 and 6 of -1.85 mV (P = .02). There was no difference in impedance or pacing threshold or in lead lifetime between the 2 groups over 6-year follow-up (5.91 ± 3.89 years vs 5.48 ± 3.70 years, P = .239). CONCLUSION: In ARVC patients with ICD leads implanted in the RV apex, ventricular sensing deteriorates significantly during medium-term follow-up. Septal RV lead placement should be explored as the first choice at implantation.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis/efeitos adversos , Efeitos Adversos de Longa Duração , Adulto , Displasia Arritmogênica Ventricular Direita/patologia , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Displasia Arritmogênica Ventricular Direita/terapia , Canadá , Eletrocardiografia/métodos , Falha de Equipamento/estatística & dados numéricos , Feminino , Septos Cardíacos/patologia , Septos Cardíacos/fisiopatologia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Efeitos Adversos de Longa Duração/diagnóstico , Efeitos Adversos de Longa Duração/etiologia , Efeitos Adversos de Longa Duração/fisiopatologia , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Estudos Retrospectivos
17.
J Interv Card Electrophysiol ; 47(2): 163-170, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27394160

RESUMO

BACKGROUND: The protective effect of beta-blockers in patients with inherited Long-QT syndrome is well established. Recent reports have suggested that beta-blockers are not equally effective in Long-QT (LQT). Bisoprolol is an attractive candidate for use in LQT because of its cardioselective properties and favorable side-effect profile. METHODS: We performed a retrospective cohort study of 114 consecutive patients with gene-positive Long-QT syndrome type 1 (LQT1) or Long-QT syndrome type 2 (LQT2) treated with bisoprolol, nadolol or atenolol with a total of 580 person-years of follow-up. Electrocardiogram (ECG) parameters and cardiac events during follow-up were compared. In addition, exercise treadmill testing was performed in bisoprolol-treated patients. RESULTS: Fifty-nine patients were treated with bisoprolol, 39 with atenolol and 16 with nadolol. Overall, 59 % were females and 62 % had LQT1. Baseline heart rate and corrected QT (QTc) interval were similar between the groups. QTc shortening was observed in individuals on bisoprolol (ΔQTc -5 ± 31 ms; p = 0.049) and nadolol (ΔQTc -13 ± 16 ms; p = 0.02) but not on atenolol (ΔQTc +9 ± 24 ms; p = 0.16). Median follow-up was similar for bisoprolol and nadolol (3 years), but longer for atenolol (6 years; p = 0.03); one cardiac event occurred in the bisoprolol group (1.7 %) and two events occurred in the atenolol group (5.1 %; p = 0.45), whereas none occurred in nadolol-treated patients. Beta-blocker efficacy was not affected by the underlying genotype. The antiadrenergic effect of bisoprolol correlated with the reduction of peak heart rates at exercise testing. CONCLUSIONS: Bisoprolol treatment results in QTc shortening in gene-positive LQT1 and LQT2 patients and is well tolerated during long-term administration. The equivalence of bisoprolol for protection from ventricular arrhythmia in LQT patients compared to established beta-blockers remains unknown. Further large-scale studies are required.


Assuntos
Bisoprolol/administração & dosagem , Eletrocardiografia/efeitos dos fármacos , Síndrome do QT Longo/tratamento farmacológico , Síndrome de Romano-Ward/diagnóstico , Síndrome de Romano-Ward/tratamento farmacológico , Antagonistas de Receptores Adrenérgicos beta 1 , Adulto , Canadá , Cardiotônicos/administração & dosagem , Estudos de Coortes , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Síndrome do QT Longo/diagnóstico , Masculino , Estudos Retrospectivos , Resultado do Tratamento
18.
Circ Cardiovasc Qual Outcomes ; 8(2 Suppl 1): S21-30, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25714829

RESUMO

BACKGROUND: Social health is a dimension of quality of life, and refers to people's involvement in, and satisfaction with social roles, responsibilities, and activities. The implantable cardioverter-defibrillator is associated with changes in overall quality of life, but little is known about sex differences in individual trajectories of change in social health. METHODS AND RESULTS: We prospectively measured changes in 3 subscales of the SF-36v2 generic health questionnaire (role physical, role emotional, and social functioning), 2 Patient-Reported Outcomes Measurement Information System short forms (satisfaction with participation in social roles and satisfaction with participation in discretionary social activities), and the Florida Patient Acceptance Survey before and at 1, 2, and 6 months after implantation. Individual growth models of temporal change were estimated. The scores of the 6 indicators improved with time. The unconditional model demonstrated significant (fixed effects: P<0.05; covariance parameters: P<0.10) residual variability in the individual trajectories. In the conditional model, men and women differed significantly in their rates of change in the scores of 3 of the 6 measures. Although men's mean scores exceeded women's mean scores on all indicators at baseline (range of relative mean difference: 11.0% to 17.8%), the rate of women's change resulted in a reversal in relative standing at 6 months after implantation, with the mean scores of women exceeding the men's by 4.5% to 5.6%. CONCLUSIONS: Men and women differed in their trajectories of change in social health, both in terms of their starting points (ie, baseline scores) and their rates of change.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Qualidade de Vida , Comportamento Social , Adulto , Idoso , Cardioversão Elétrica/efeitos adversos , Emoções , Feminino , Disparidades nos Níveis de Saúde , Humanos , Relações Interpessoais , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Fatores Sexuais , Responsabilidade Social , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
19.
Ann Thorac Surg ; 77(6): 2083-8, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15172272

RESUMO

BACKGROUND: Malignant ventricular tachyarrhythmia early after cardiac surgery is an uncommon arrhythmic complication but has a negative impact on mortality. The purpose of this study was to evaluate the incidence of new-onset sustained postoperative ventricular tachycardia-ventricular fibrillation and to identify risk factors for the dysrhythmia. METHODS: Demographic, clinical, operative, and postoperative data, including a variable of postoperative ventricular tachycardia, were prospectively obtained from 4748 patients undergoing nonemergency coronary artery bypass graft and(or) valve replacement with no history of sustained ventricular tachycardia or sudden death. A detailed analysis was performed to define the risk factors for the ventricular tachycardia and the prognostic impact of the arrhythmia on 30-day mortality was evaluated. RESULTS: Forty-five patients (0.95%) had sustained ventricular tachycardia or ventricular fibrillation and the initial episode occurred 3.9 +/- 5.2 days (mean +/- standard deviation) after surgery. By multivariate analysis, female sex (odds ratio, 1.982), left ventricular ejection fraction (< 35%: > 50%, 4.771), the presence of pulmonary hypertension (3.066), the presence of systemic hypertension (2.391), and pump time (per 10 minutes, 1.085) were independently associated with the dysrhythmias. Early mortality of patients with the arrhythmia was 28.9%, strikingly higher than that of patients without ventricular tachycardia/ventricular fibrillation (1.9%). CONCLUSIONS: Left ventricular ejection fraction is the strongest risk factor for new-onset postoperative sustained ventricular tachycardia-ventricular fibrillation; female sex, pump time, pulmonary and systemic hypertension are independent predictors of the dysrhythmias; the arrhythmia is associated with increased 30-day mortality after cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Taquicardia Ventricular/etiologia , Fibrilação Ventricular/etiologia , Idoso , Ponte de Artéria Coronária/efeitos adversos , Feminino , Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia
20.
J Am Soc Echocardiogr ; 17(7): 769-74, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15220903

RESUMO

BACKGROUND: This study describes the use and outcomes of transesophageal echocardiography to guide atrial fibrillation (AF) ablation procedures. METHODS: Under general anesthesia, 25 patients with a history of AF underwent multiplane transesophageal echocardiography in conjunction with catheter placement under fluoroscopy. RESULTS: In this series, a combined fluoroscopic/echocardiographic approach obviated the need for angiographic imaging. Anatomic variation in pulmonary veins (PV) was common; the shortest distance between the ostia ranged from 2 to 11 mm. Individual PV diameters did not predict the presence of ectopic foci. The number of radiofrequency pulses delivered per vein was 2.6 +/- 2.3 (range: 0-10). Mean fluoroscopy time per procedure was 31 +/- 13 minutes and mean procedure time was 110 +/- 31 minutes. At follow-up, 68% of patients were free from AF. CONCLUSIONS: Transesophageal echocardiography enables identification and cannulation of the ostia and proximal branches of PV during AF ablation. Fluoroscopy, procedure times, and outcomes compare favorably with series using PV angiography and, as such, suggest that a controlled trial is warranted.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ecocardiografia Transesofagiana , Veias Pulmonares/diagnóstico por imagem , Adulto , Idoso , Ecocardiografia Transesofagiana/métodos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA