Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nat Methods ; 21(5): 882-888, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38395993

RESUMO

Light-sheet fluorescence microscopy is an invaluable tool for four-dimensional biological imaging of multicellular systems due to the rapid volumetric imaging and minimal illumination dosage. However, it is challenging to retrieve fine subcellular information, especially in living cells, due to the width of the sheet of light (>1 µm). Here, using reversibly switchable fluorescent proteins (RSFPs) and a periodic light pattern for photoswitching, we demonstrate a super-resolution imaging method for rapid volumetric imaging of subcellular structures called multi-sheet RESOLFT. Multiple emission-sheets with a width that is far below the diffraction limit are created in parallel increasing recording speed (1-2 Hz) to provide super-sectioning ability (<100 nm). Our technology is compatible with various RSFPs due to its minimal requirement in the number of switching cycles and can be used to study a plethora of cellular structures. We track cellular processes such as cell division, actin motion and the dynamics of virus-like particles in three dimensions.


Assuntos
Microscopia de Fluorescência , Microscopia de Fluorescência/métodos , Humanos , Proteínas Luminescentes/química , Proteínas Luminescentes/metabolismo , Animais , Actinas/metabolismo , Imageamento Tridimensional/métodos , Proteínas de Fluorescência Verde/metabolismo , Proteínas de Fluorescência Verde/química , Células HeLa
2.
Nat Methods ; 19(4): 461-469, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35314838

RESUMO

The promise of single-objective light-sheet microscopy is to combine the convenience of standard single-objective microscopes with the speed, coverage, resolution and gentleness of light-sheet microscopes. We present DaXi, a single-objective light-sheet microscope design based on oblique plane illumination that achieves: (1) a wider field of view and high-resolution imaging via a custom remote focusing objective; (2) fast volumetric imaging over larger volumes without compromising image quality or necessitating tiled acquisition; (3) fuller image coverage for large samples via multi-view imaging and (4) higher throughput multi-well imaging via remote coverslip placement. Our instrument achieves a resolution of 450 nm laterally and 2 µm axially over an imaging volume of 3,000 × 800 × 300 µm. We demonstrate the speed, field of view, resolution and versatility of our instrument by imaging various systems, including Drosophila egg chamber development, zebrafish whole-brain activity and zebrafish embryonic development - up to nine embryos at a time.


Assuntos
Encéfalo , Peixe-Zebra , Animais , Encéfalo/diagnóstico por imagem , Drosophila , Desenvolvimento Embrionário , Microscopia de Fluorescência/métodos
3.
Nat Methods ; 18(7): 829-834, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34183831

RESUMO

We introduce a cost-effective and easily implementable scan unit that converts any camera-based microscope with optical sectioning capability into a multi-angle projection imaging system. Projection imaging reduces data overhead and accelerates imaging by a factor of >100, while also allowing users to readily view biological phenomena of interest from multiple perspectives on the fly. By rapidly interrogating the sample from just two perspectives, our method also enables real-time stereoscopic imaging and three-dimensional particle localization. We demonstrate projection imaging with spinning disk confocal, lattice light-sheet, multidirectional illumination light-sheet and oblique plane microscopes on specimens that range from organelles in single cells to the vasculature of a zebrafish embryo. Furthermore, we leverage our projection method to rapidly image cancer cell morphodynamics and calcium signaling in cultured neurons at rates up to 119 Hz as well as to simultaneously image orthogonal views of a beating embryonic zebrafish heart.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microscopia Confocal/instrumentação , Microscopia Confocal/métodos , Animais , Colo/citologia , Embrião não Mamífero/citologia , Feminino , Coração/diagnóstico por imagem , Coração/embriologia , Humanos , Imageamento Tridimensional , Masculino , Camundongos , Camundongos Transgênicos , Neurônios/citologia , Ratos Sprague-Dawley , Esferoides Celulares/patologia , Peixe-Zebra/embriologia
4.
Exp Physiol ; 108(2): 240-252, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36454193

RESUMO

NEW FINDINGS: What is the central question of this study? Skeletal muscle extracellular vesicles likely act as pro-angiogenic signalling factors: does overexpression of peroxisome proliferator-activated receptor γ coactivator 1-α (PGC-1α) alter skeletal muscle myotube extracellular vesicle release, contents and angiogenic potential? What is the main finding and its importance? Overexpression of PGC-1α results in secretion of extracellular vesicles that elevate measures of angiogenesis and protect against acute oxidative stress in vitro. Skeletal muscle with high levels of PGC-1α expression, commonly associated with exercise induced angiogenesis and high basal capillarization, may secrete extracellular vesicles that support capillary growth and maintenance. ABSTRACT: Skeletal muscle capillarization is proportional to muscle fibre mitochondrial content and oxidative capacity. Skeletal muscle cells secrete many factors that regulate neighbouring capillary endothelial cells (ECs), including extracellular vesicles (SkM-EVs). Peroxisome proliferator-activated receptor γ coactivator 1-α (PGC-1α) regulates mitochondrial biogenesis and the oxidative phenotype in skeletal muscle. Skeletal muscle PGC-1α also regulates secretion of multiple angiogenic factors, but it is unknown whether PGC-1α regulates SkM-EV release, contents and angiogenic signalling potential. PGC-1α was overexpressed via adenovirus in primary human myotubes. EVs were collected from PGC-1α-overexpressing myotubes (PGC-EVs) as well as from green fluorescent protein-overexpressing myotubes (GFP-EVs), and from untreated myotubes. EV release and select mRNA contents were measured from EVs. Additionally, ECs were treated with EVs to measure angiogenic potential of EVs in normal conditions and following an oxidative stress challenge. PGC-1α overexpression did not impact EV release but did elevate EV content of mRNAs for several antioxidant proteins (nuclear factor erythroid 2-related factor 2, superoxide dismutase 2, glutathione peroxidase). PGC-EV treatment of cultured human umbilical vein endothelial cells (HUVECs) increased their proliferation (+36.6%), tube formation (length: +28.1%; number: +25.7%) and cellular viability (+52.9%), and reduced reactive oxygen species levels (-41%) compared to GFP-EVs. Additionally, PGC-EV treatment protected against tube formation impairments and induction of cellular senescence following acute oxidative stress. Overexpression of PGC-1α in human myotubes increases the angiogenic potential of SkM-EVs. These angiogenic benefits coincided with increased anti-oxidative capacity of recipient HUVECs. High PGC-1α expression in skeletal muscle may prompt the release of SkM-EVs that support vascular redox homeostasis and angiogenesis.


Assuntos
Vesículas Extracelulares , Fatores de Transcrição , Humanos , Fatores de Transcrição/metabolismo , Coativador 1-alfa do Receptor gama Ativado por Proliferador de Peroxissomo/metabolismo , Músculo Esquelético/metabolismo , Células Endoteliais da Veia Umbilical Humana/metabolismo , Vesículas Extracelulares/metabolismo
5.
Phys Chem Chem Phys ; 23(33): 17752-17760, 2021 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-34190253

RESUMO

The relative surface affinities of pyridine within microporous HZSM-5 zeolites are explored using two-dimensional 1H nuclear magnetic resonance (NMR) relaxation time measurements. The dimensionless ratio of longitudinal-to-transverse nuclear spin relaxation times T1/T2 is shown to exhibit strong sensitivity to the silica/alumina ratio (SAR) of these zeolites, which is indicative of material acidity. This trend is interpreted in terms of increased pyridine surface affinity with decreasing SAR. Temperature programmed desorption (TPD) analysis corroborates this observation, revealing a distinct increase in the heat of desorption associated with adsorbed pyridine as a function of decreasing SAR. A direct correlation between NMR and TPD data suggests NMR relaxation time analysis can be a valuable tool for the non-invasive characterisation of adsorption phenomena in microporous solids.

6.
PLoS Genet ; 10(8): e1004526, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25101664

RESUMO

Sporulation in the bacterium Bacillus subtilis is a developmental program in which a progenitor cell differentiates into two different cell types, the smaller of which eventually becomes a dormant cell called a spore. The process begins with an asymmetric cell division event, followed by the activation of a transcription factor, σF, specifically in the smaller cell. Here, we show that the structural protein DivIVA localizes to the polar septum during sporulation and is required for asymmetric division and the compartment-specific activation of σF. Both events are known to require a protein called SpoIIE, which also localizes to the polar septum. We show that DivIVA copurifies with SpoIIE and that DivIVA may anchor SpoIIE briefly to the assembling polar septum before SpoIIE is subsequently released into the forespore membrane and recaptured at the polar septum. Finally, using super-resolution microscopy, we demonstrate that DivIVA and SpoIIE ultimately display a biased localization on the side of the polar septum that faces the smaller compartment in which σF is activated.


Assuntos
Proteínas de Bactérias/genética , Proteínas de Ciclo Celular/genética , Fator sigma/genética , Esporos Bacterianos/genética , Divisão Celular Assimétrica/genética , Bacillus subtilis/genética , Bacillus subtilis/crescimento & desenvolvimento , Polaridade Celular , Regulação Bacteriana da Expressão Gênica , Esporos Bacterianos/crescimento & desenvolvimento
7.
Proc Natl Acad Sci U S A ; 111(14): 5254-9, 2014 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-24706872

RESUMO

Multifocal structured illumination microscopy (MSIM) provides a twofold resolution enhancement beyond the diffraction limit at sample depths up to 50 µm, but scattered and out-of-focus light in thick samples degrades MSIM performance. Here we implement MSIM with a microlens array to enable efficient two-photon excitation. Two-photon MSIM gives resolution-doubled images with better sectioning and contrast in thick scattering samples such as Caenorhabditis elegans embryos, Drosophila melanogaster larval salivary glands, and mouse liver tissue.


Assuntos
Iluminação , Microscopia/métodos , Fótons , Animais , Caenorhabditis elegans/embriologia , Drosophila melanogaster/crescimento & desenvolvimento , Larva/química , Fígado/química , Camundongos
8.
Nat Methods ; 10(11): 1122-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24097271

RESUMO

Existing super-resolution fluorescence microscopes compromise acquisition speed to provide subdiffractive sample information. We report an analog implementation of structured illumination microscopy that enables three-dimensional (3D) super-resolution imaging with a lateral resolution of 145 nm and an axial resolution of 350 nm at acquisition speeds up to 100 Hz. By using optical instead of digital image-processing operations, we removed the need to capture, store and combine multiple camera exposures, increasing data acquisition rates 10- to 100-fold over other super-resolution microscopes and acquiring and displaying super-resolution images in real time. Low excitation intensities allow imaging over hundreds of 2D sections, and combined physical and computational sectioning allow similar depth penetration to spinning-disk confocal microscopy. We demonstrate the capability of our system by imaging fine, rapidly moving structures including motor-driven organelles in human lung fibroblasts and the cytoskeleton of flowing blood cells within developing zebrafish embryos.


Assuntos
Embrião de Mamíferos/citologia , Animais , Microscopia de Fluorescência
9.
Methods ; 88: 37-47, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26210400

RESUMO

A challenge in biological imaging is to capture high-resolution images at fast frame rates in live cells. The "instant structured illumination microscope" (iSIM) is a system designed for this purpose. Similarly to standard structured illumination microscopy (SIM), an iSIM provides a twofold improvement over widefield microscopy, in x, y and z, but also allows much faster image acquisition, with real-time display of super-resolution images. The assembly of an iSIM is reasonably complex, involving the combination and alignment of many optical components, including three micro-optics arrays (two lenslet arrays and an array of pinholes, all with a pitch of 222 µm) and a double-sided scanning mirror. In addition, a number of electronic components must be correctly controlled. Construction of the system is therefore not trivial, but is highly desirable, particularly for live-cell imaging. We report, and provide instructions for, the construction of an iSIM, including minor modifications to a previous design in both hardware and software. The final instrument allows us to rapidly acquire fluorescence images at rates faster than 100 fps, with approximately twofold improvement in resolution in both x-y and z; sub-diffractive biological features have an apparent size (full width at half maximum) of 145 nm (lateral) and 320 nm (axial), using a 1.49 NA objective and 488 nm excitation.


Assuntos
Aumento da Imagem , Imageamento Tridimensional/instrumentação , Microscopia de Fluorescência/instrumentação , Software , Limite de Detecção
10.
Phys Chem Chem Phys ; 18(26): 17159-68, 2016 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-27306298

RESUMO

The diffusion of ammonia in commercial NH3-SCR catalyst Cu-CHA was measured and compared with H-CHA using quasielastic neutron scattering (QENS) and molecular dynamics (MD) simulations to assess the effect of counterion presence on NH3 mobility in automotive emission control relevant zeolite catalysts. QENS experiments observed jump diffusion with a jump distance of 3 Å, giving similar self-diffusion coefficient measurements for both Cu- and H-CHA samples, in the range of ca. 5-10 × 10(-10) m(2) s(-1) over the measured temperature range. Self-diffusivities calculated by MD were within a factor of 6 of those measured experimentally at each temperature. The activation energies of diffusion were also similar for both studied systems: 3.7 and 4.4 kJ mol(-1) for the H- and Cu-chabazite respectively, suggesting that counterion presence has little impact on ammonia diffusivity on the timescale of the QENS experiment. An explanation is given by the MD simulations, which showed the strong coordination of NH3 with Cu(2+) counterions in the centre of the chabazite cage, shielding other molecules from interaction with the ion, and allowing for intercage diffusion through the 8-ring windows (consistent with the experimentally observed jump length) to carry on unhindered.

11.
Pain Med ; 17(12): 2291-2304, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-28025363

RESUMO

INTRODUCTION: Adverse drug events (ADEs) have been highlighted as a major patient safety and public health challenge by the National Action Plan for Adverse Drug Event Prevention (ADE Action Plan), which was released by the Office of Disease Prevention and Health Promotion (ODPHP) in August 2014. The ADE Action Plan focuses on surveillance, evidence-based prevention, incentives, and oversights, additional research needs as well as possible measures and metrics to track progress of ADE prevention within three drug classes: anticoagulants, diabetes agents, and opioids.Objectives and Recommendations. With outpatient opioid prescriptions being a great concern among many healthcare providers, this article focuses on recommendations from the ADE Action Plan to help guide safer opioid use in healthcare delivery settings. Its aim is to discuss current federal methods in place to prevent opioid ADEs while also providing evidence to encourage providers and hospitals to innovate new systems and practices to increase prevention.


Assuntos
Analgésicos Opioides/efeitos adversos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/prevenção & controle , Diretrizes para o Planejamento em Saúde , Política de Saúde/legislação & jurisprudência , Transtornos Relacionados ao Uso de Opioides/prevenção & controle , Humanos
12.
Nat Methods ; 9(7): 749-54, 2012 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-22581372

RESUMO

We demonstrate three-dimensional (3D) super-resolution in live multicellular organisms using structured illumination microscopy (SIM). Sparse multifocal illumination patterns generated by a digital micromirror device (DMD) allowed us to physically reject out-of-focus light, enabling 3D subdiffractive imaging in samples eightfold thicker than had been previously imaged with SIM. We imaged samples at one 2D image per second, at resolutions as low as 145 nm laterally and 400 nm axially. In addition to dual-labeled, whole fixed cells, we imaged GFP-labeled microtubules in live transgenic zebrafish embryos at depths >45 µm. We captured dynamic changes in the zebrafish lateral line primordium and observed interactions between myosin IIA and F-actin in cells encapsulated in collagen gels, obtaining two-color 4D super-resolution data sets spanning tens of time points and minutes without apparent phototoxicity. Our method uses commercially available parts and open-source software and is simpler than existing SIM implementations, allowing easy integration with wide-field microscopes.


Assuntos
Embrião não Mamífero , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Microscopia Confocal/métodos , Animais , Animais Geneticamente Modificados/embriologia , Animais Geneticamente Modificados/genética , Embrião não Mamífero/metabolismo , Embrião não Mamífero/ultraestrutura , Proteínas de Fluorescência Verde/genética , Aumento da Imagem/instrumentação , Imageamento Tridimensional/instrumentação , Iluminação , Microscopia Confocal/instrumentação , Transgenes , Peixe-Zebra/embriologia , Peixe-Zebra/genética
13.
Jt Comm J Qual Patient Saf ; 41(8): 351-60, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26215524

RESUMO

BACKGROUND: Adverse drug events (ADEs) are important contributors to preventable morbidity and mortality, comprising one third of all hospital adverse events. In response to growing evidence detailing the high prevalence of ADEs, particularly among vulnerable older adults, Congress requested that the Secretary of the Department of Health and Human Services (HHS) convene a Federal Interagency Steering Committee to establish a National Action Plan to focus on ADE prevention. In August 2014, the Office of Disease Prevention and Health Promotion released the final version of the National Action Plan for Adverse Drug Event Prevention. The Action Plan directly supports the goals of the HHS Strategic Plan and the Patient Protection and Affordable Care Act by providing guidance on tracking and preventing ADEs, as well as describing evidence-based tools and resources to enhance medication safety. ADE ACTION PLAN CONTENT: The Federal Interagency Steering Committee focused the Action Plan on ADEs that are clinically significant, account for the greatest number of measurable harms as identified by using existing surveillance tools, and are largely preventable. As such, the decision was made to target three medication classes: anticoagulants, diabetes agents (insulin and oral hypoglycemic agents), and opioids. The Action Plan is organized around four key areas: surveillance; evidence-based prevention; payment, policy incentives, and oversight; and research opportunities to advance medication safety. CONCLUSION: One measure of the ADE Action Plan's success will be the wider dissemination of information and educational resources to providers and patients (or consumers) regarding the risks associated with medications. Future Action Plan iterations are likely to consider other high-priority medication classes and update the recommendations.


Assuntos
Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/prevenção & controle , United States Dept. of Health and Human Services/organização & administração , Sistemas de Notificação de Reações Adversas a Medicamentos/organização & administração , Centers for Medicare and Medicaid Services, U.S./organização & administração , Continuidade da Assistência ao Paciente/organização & administração , Educação em Saúde/organização & administração , Humanos , Sistemas de Informação/organização & administração , Relações Interinstitucionais , Erros de Medicação/prevenção & controle , Vigilância em Saúde Pública/métodos , Estados Unidos
14.
Nat Methods ; 8(4): 327-33, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21317909

RESUMO

We demonstrate three-dimensional (3D) super-resolution microscopy in whole fixed cells using photoactivated localization microscopy (PALM). The use of the bright, genetically expressed fluorescent marker photoactivatable monomeric (m)Cherry (PA-mCherry1) in combination with near diffraction-limited confinement of photoactivation using two-photon illumination and 3D localization methods allowed us to investigate a variety of cellular structures at <50 nm lateral and <100 nm axial resolution. Compared to existing methods, we have substantially reduced excitation and bleaching of unlocalized markers, which allows us to use 3D PALM imaging with high localization density in thick structures. Our 3D localization algorithms, which are based on cross-correlation, do not rely on idealized noise models or specific optical configurations. This allows instrument design to be flexible. By generating appropriate fusion constructs and expressing them in Cos7 cells, we could image invaginations of the nuclear membrane, vimentin fibrils, the mitochondrial network and the endoplasmic reticulum at depths of greater than 8 µm.


Assuntos
Microscopia de Fluorescência por Excitação Multifotônica/métodos , Transporte Proteico/fisiologia , Algoritmos , Animais , Células COS , Chlorocebus aethiops , Imageamento Tridimensional , Microscopia Confocal , Microscopia de Interferência , Fótons
15.
Chemphyschem ; 15(4): 794-800, 2014 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-24436314

RESUMO

We use Richardson-Lucy (RL) deconvolution to combine multiple images of a simulated object into a single image in the context of modern fluorescence microscopy techniques. RL deconvolution can merge images with very different point-spread functions, such as in multiview light-sheet microscopes,1, 2 while preserving the best resolution information present in each image. We show that RL deconvolution is also easily applied to merge high-resolution, high-noise images with low-resolution, low-noise images, relevant when complementing conventional microscopy with localization microscopy. We also use RL deconvolution to merge images produced by different simulated illumination patterns, relevant to structured illumination microscopy (SIM)3, 4 and image scanning microscopy (ISM). The quality of our ISM reconstructions is at least as good as reconstructions using standard inversion algorithms for ISM data, but our method follows a simpler recipe that requires no mathematical insight. Finally, we apply RL deconvolution to merge a series of ten images with varying signal and resolution levels. This combination is relevant to gated stimulated-emission depletion (STED) microscopy, and shows that merges of high-quality images are possible even in cases for which a non-iterative inversion algorithm is unknown.


Assuntos
Processamento de Imagem Assistida por Computador , Microscopia/métodos , Algoritmos
16.
Nat Biotechnol ; 41(4): 552-559, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36217028

RESUMO

The formation of macromolecular complexes can be measured by detection of changes in rotational mobility using time-resolved fluorescence anisotropy. However, this method is limited to relatively small molecules (~0.1-30 kDa), excluding the majority of the human proteome and its complexes. We describe selective time-resolved anisotropy with reversibly switchable states (STARSS), which overcomes this limitation and extends the observable mass range by more than three orders of magnitude. STARSS is based on long-lived reversible molecular transitions of switchable fluorescent proteins to resolve the relatively slow rotational diffusivity of large complexes. We used STARSS to probe the rotational mobility of several molecular complexes in cells, including chromatin, the retroviral Gag lattice and activity-regulated cytoskeleton-associated protein oligomers. Because STARSS can probe arbitrarily large structures, it is generally applicable to the entire human proteome.


Assuntos
Proteoma , Humanos , Polarização de Fluorescência/métodos , Espectrometria de Fluorescência/métodos
17.
Chem Commun (Camb) ; 59(85): 12767-12770, 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37812072

RESUMO

We use in situ neutron imaging to observe the adsorption/absorption of hydrogen within a packed catalyst bed of a Pd/C catalyst at a spatial and temporal resolution of ∼430 µm and a ∼9 s respectively. Additionally, the H2/D2 exchange process across the catalyst bed is followed in real time.

18.
Chem Sci ; 14(44): 12621-12636, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38020362

RESUMO

Oxygen storage and release is a foundational part of many key pathways in heterogeneous catalysis, such as the Mars-van Krevelen mechanism. However, direct measurement of oxygen storage capacity (OSC) is time-consuming and difficult to parallelise. To accelerate the discovery of stable high OSC rare-earth doped ceria-zirconia oxygen storage catalysts, a high-throughput robotic-based co-precipitation synthesis route was coupled with sequentially automated powder X-ray diffraction (PXRD), Raman and thermogravimetric analysis (TGA) characterisation of the resulting materials libraries. Automated extraction of data enabled rapid trend identification and provided a data set for the development of an OSC prediction model, investigating the significance of each extracted quantity towards OSC. The optimal OSC prediction model produced incorporated variables from only fast-to-measure analytical techniques and gave predicted values of OSC that agreed with experimental observations across an independent validation set. Those measured quantities that feature in the model emerge as proxies for OSC performance. The ability to predict the OSC of the materials accelerates the discovery of high-capacity oxygen storage materials and motivates the development of similar high-throughput workflows to identify candidate catalysts for other heterogeneous transformations.

19.
Biomed Opt Express ; 13(11): 5616-5627, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36733723

RESUMO

Fast volumetric imaging of large fluorescent samples with high-resolution is required for many biological applications. Oblique plane microscopy (OPM) provides high spatiotemporal resolution, but the field of view is typically limited by its optical train and the pixel number of the camera. Mechanically scanning the sample or decreasing the overall magnification of the imaging system can partially address this challenge, albeit by reducing the volumetric imaging speed or spatial resolution, respectively. Here, we introduce a novel dual-axis scan unit for OPM that facilitates rapid and high-resolution volumetric imaging throughout a volume of 800 × 500 × 200 microns. This enables us to perform volumetric imaging of cell monolayers, spheroids and zebrafish embryos with subcellular resolution. Furthermore, we combined this microscope with a multi-perspective projection imaging technique that increases the volumetric interrogation rate to more than 10 Hz. This allows us to rapidly probe a large field of view in a dimensionality reduced format, identify features of interest, and volumetrically image these regions with high spatiotemporal resolution.

20.
Genetics ; 217(4)2021 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-33693628

RESUMO

We create and share a new red fluorophore, along with a set of strains, reagents and protocols, to make it faster and easier to label endogenous Caenorhabditis elegans proteins with fluorescent tags. CRISPR-mediated fluorescent labeling of C. elegans proteins is an invaluable tool, but it is much more difficult to insert fluorophore-size DNA segments than it is to make small gene edits. In principle, high-affinity asymmetrically split fluorescent proteins solve this problem in C. elegans: the small fragment can quickly and easily be fused to almost any protein of interest, and can be detected wherever the large fragment is expressed and complemented. However, there is currently only one available strain stably expressing the large fragment of a split fluorescent protein, restricting this solution to a single tissue (the germline) in the highly autofluorescent green channel. No available C. elegans lines express unbound large fragments of split red fluorescent proteins, and even state-of-the-art split red fluorescent proteins are dim compared to the canonical split-sfGFP protein. In this study, we engineer a bright, high-affinity new split red fluorophore, split-wrmScarlet. We generate transgenic C. elegans lines to allow easy single-color labeling in muscle or germline cells and dual-color labeling in somatic cells. We also describe a novel expression strategy for the germline, where traditional expression strategies struggle. We validate these strains by targeting split-wrmScarlet to several genes whose products label distinct organelles, and we provide a protocol for easy, cloning-free CRISPR/Cas9 editing. As the collection of split-FP strains for labeling in different tissues or organelles expands, we will post updates at doi.org/10.5281/zenodo.3993663.


Assuntos
Proteínas de Caenorhabditis elegans/metabolismo , Proteínas de Fluorescência Verde/metabolismo , Proteínas Luminescentes/metabolismo , Animais , Caenorhabditis elegans , Proteínas de Caenorhabditis elegans/genética , Engenharia Genética/métodos , Células Germinativas/citologia , Células Germinativas/metabolismo , Proteínas de Fluorescência Verde/genética , Proteínas Luminescentes/genética , Transporte Proteico , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Proteína Vermelha Fluorescente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA