Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 130(2): 161-7, 2014 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-24914037

RESUMO

BACKGROUND: Children with heart disease are frequently exposed to imaging examinations that use ionizing radiation. Although radiation exposure is potentially carcinogenic, there are limited data on cumulative exposure and the associated cancer risk. We evaluated the cumulative effective dose of radiation from all radiation examinations to estimate the lifetime attributable risk of cancer in children with heart disease. METHODS AND RESULTS: Children ≤6 years of age who had previously undergone 1 of 7 primary surgical procedures for heart disease at a single institution between 2005 and 2010 were eligible for the study. Exposure to radiation-producing examinations was tabulated, and cumulative effective dose was calculated in millisieverts. These data were used to estimate lifetime attributable risk of cancer above baseline using the approach of the Committee on Biological Effects of Ionizing Radiation VII. The cohort included 337 children exposed to 13 932 radiation examinations. Conventional radiographs represented 92% of examinations, whereas cardiac catheterization and computed tomography accounted for 81% of cumulative exposure. Overall median cumulative effective dose was 2.7 mSv (range, 0.1-76.9 mSv), and the associated lifetime attributable risk of cancer was 0.07% (range, 0.001%-6.5%). Median lifetime attributable risk of cancer ranged widely depending on surgical complexity (0.006%-1.6% for the 7 surgical cohorts) and was twice as high in females per unit exposure (0.04% versus 0.02% per 1-mSv effective dose for females versus males, respectively; P<0.001). CONCLUSIONS: Overall radiation exposures in children with heart disease are relatively low; however, select cohorts receive significant exposure. Cancer risk estimation highlights the need to limit radiation dose, particularly for high-exposure modalities.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Diagnóstico por Imagem/efeitos adversos , Cardiopatias/diagnóstico , Neoplasias Induzidas por Radiação/diagnóstico , Doses de Radiação , Pré-Escolar , Estudos de Coortes , Feminino , Cardiopatias/epidemiologia , Humanos , Lactente , Recém-Nascido , Masculino , Neoplasias Induzidas por Radiação/epidemiologia , Fatores de Risco
2.
J Urol ; 194(4): 878-85, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26055822

RESUMO

PURPOSE: There is rising concern over the increasing amount of patient radiation exposure from diagnostic imaging and medical procedures. Patients with nephrolithiasis are at potentially significant risk for radiation exposure due to the need for imaging to manage recurrent stone disease. We reviewed the literature in an attempt to better characterize actual risks and discussed methods to reduce radiation exposure for adult patients with nephrolithiasis. MATERIALS AND METHODS: A PubMed search was performed using the key words nephrolithiasis, stones, radiation, fluoroscopy, ureteroscopy, percutaneous nephrolithotomy, computerized tomography and shock wave lithotripsy. Additional citations were identified by reviewing reference lists of pertinent articles. RESULTS: A total of 50 relevant articles were included in this review. Patients with a first time acute stone event are exposed to a significant amount of radiation. Most radiation is from computerized tomography. Patients undergoing percutaneous nephrolithotomy are exposed to an equal or greater amount of radiation than they received from computerized tomography. Risk factors for increased exposure during percutaneous nephrolithotomy include obesity, multiple tracts and a larger stone burden. Ureteroscopy exposes patients to approximately the same amount of radiation as plain x-ray of the kidneys, ureters and bladder. Risk factors for increased exposure during ureteroscopy include obesity and ureteral dilation. During shock wave lithotripsy the amount of radiation exposure is not well characterized. Interventions to reduce exposure to patients include using ultrasound when possible and implementing low dose computerized tomography protocols. The as low as reasonably achievable principle of radiation exposure should always be followed when fluoroscopy is performed. The use of an air retrograde pyelogram may also reduce exposure during percutaneous nephrolithotomy. Fluoroscopy time during ureteroscopy may be decreased by a laser guided C-arm, a dedicated C-arm technician, stent placement under direct vision and tactile feedback to help guide wire placement. CONCLUSIONS: Patients with nephrolithiasis are at significant risk for increased radiation exposure from the imaging and fluoroscopy used during treatment. The true risks of low radiation exposure remain uncertain. It is important to be aware of these risks to provide better counseling for patients. Urologists must also be familiar with techniques to decrease radiation exposure for patients with nephrolithiasis.


Assuntos
Nefrolitíase/diagnóstico , Nefrolitíase/terapia , Exposição à Radiação , Diagnóstico por Imagem/efeitos adversos , Humanos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Tomografia Computadorizada por Raios X/efeitos adversos
3.
AJR Am J Roentgenol ; 204(5): W579-85, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25905965

RESUMO

OBJECTIVE: The purpose of this study is to measure the organ doses and effective dose (ED) for parathyroid 4D CT and scintigraphy and to estimate the lifetime attributable risk of cancer incidence associated with imaging. MATERIALS AND METHODS: Organ radiation doses for 4D CT and scintigraphy were measured on the basis of imaging with our institution's protocols. An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was scanned to measure CT organ dose. Organ doses from the radionuclide were based on International Commission for Radiological Protection report 80. ED was calculated for 4D CT and scintigraphy and was used to estimate the lifetime attributable risk of cancer incidence for patients differing in age and sex with the approach established by the Biologic Effects of Ionizing Radiation VII report. A 55-year-old woman was selected as the standard patient according to the demographics of patients with primary hyperparathyroidism. RESULTS: Organs receiving the highest radiation dose from 4D CT were the thyroid (150.6 mGy) and salivary glands (137.8 mGy). For scintigraphy, the highest organ doses were to the colon (41.5 mGy), gallbladder (39.8 mGy), and kidneys (32.3 mGy). The ED was 28 mSv for 4D CT, compared with 12 mSv for scintigraphy. In the exposed standard patient, the lifetime attributable risk for cancer incidence was 193 cancers/100,000 patients for 4D CT and 68 cancers/100,000 patients for scintigraphy. Given a baseline lifetime incidence of cancer of 46,300 cancers/100,000 patients, imaging results in an increase in lifetime incidence of cancer over baseline of 0.52% for 4D CT and 0.19% for scintigraphy. CONCLUSION: The ED of 4D CT is more than double that of scintigraphy, but both studies cause negligible increases in lifetime risk of cancer. Clinicians should not allow concern for radiation-induced cancer to influence decisions regarding workup in older patients.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Induzidas por Radiação/etiologia , Doenças das Paratireoides/diagnóstico por imagem , Doses de Radiação , Feminino , Humanos , Incidência , Masculino , Neoplasias Induzidas por Radiação/epidemiologia , Imagens de Fantasmas , Cintilografia , Medição de Risco , Fatores de Risco
4.
Abdom Imaging ; 40(7): 2606-12, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25989931

RESUMO

PURPOSE: Computed tomographic (CT) fluoroscopy-guided percutaneous cryoablation is an effective therapeutic method used to treat focal renal masses. The purpose of this study is to quantify the radiation dose to the patient and interventional radiologist during percutaneous cryoablation of renal masses using CT fluoroscopic guidance. METHODS: Over a 1-year period, the CT fluoroscopy time during percutaneous cryoablation of renal masses was recorded in 41 patients. The level of complexity of each procedure was designated as simple, intermediate, or complex. Patient organ radiation doses were estimated using an anthropomorphic model. Dose to the interventional radiologist was estimated using ion chamber survey meters. RESULTS: The average CT fluoroscopy time for technically simple cases was 47 s, 126 s for intermediate cases, and 264 s for complex cases. The relative risk of hematologic stomach and liver malignancy in patients undergoing this procedure was 1.003-1.074. The lifetime attributable risk of cancer ranged from 2 to 58, with the highest risk in younger patients for developing leukemia. The estimated radiation dose to the interventionalist without lead shielding was 390 mR (3.9 mGy) per year of cases. CONCLUSIONS: The radiation risk to the patient during CT fluoroscopy-guided percutaneous renal mass cryoablation is, as expected, related to procedure complexity. Quantification of patient organ radiation dose was estimated using an anthropomorphic model. This information, along with the associated relative risk of malignancy, may assist in evaluating risks of the procedure, particularly in younger patients. The radiation dose to the interventionist is low regardless of procedure complexity, but highlights the importance of lead shielding.


Assuntos
Criocirurgia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Doses de Radiação , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia , Humanos , Rim/diagnóstico por imagem , Rim/cirurgia , Masculino , Pessoa de Meia-Idade , Risco , Adulto Jovem
5.
J Urol ; 189(6): 2142-6, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23261481

RESUMO

PURPOSE: Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults. MATERIALS AND METHODS: We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation doses. The nonobese and obese models have an approximate body mass index of 24 and 30 kg/m(2), respectively. Three runs of renal stone protocol computerized tomography were performed on each phantom under automatic tube current modulation. Organ specific absorbed doses were measured and effective doses were calculated. RESULTS: The bone marrow of each model received the highest dose and the skin received the second highest dose. The mean ± SD effective dose for the nonobese and obese models was 3.04 ± 0.34 and 10.22 ± 0.50 mSv, respectively (p <0.0001). CONCLUSIONS: The effective dose of stone protocol computerized tomography in obese patients is more than threefold higher than the dose in nonobese patients using automatic tube current modulation. The implication of this finding extends beyond the urological stone population and adds to our understanding of radiation exposure from medical imaging.


Assuntos
Obesidade/complicações , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Carga Corporal (Radioterapia) , Índice de Massa Corporal , Humanos , Masculino , Modelos Teóricos , Nefrolitíase/diagnóstico por imagem , Monitoramento de Radiação/métodos , Recidiva , Valores de Referência , Tomografia Computadorizada por Raios X/métodos
6.
J Urol ; 190(6): 2117-23, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23764073

RESUMO

PURPOSE: Computerized tomography use increased exponentially in the last 3 decades, and it is commonly used to evaluate many urological conditions. Ionizing radiation exposure from medical imaging is linked to the risk of malignancy. We measured the organ and calculated effective doses of different studies to determine whether the dose-length product method is an accurate estimation of radiation exposure. MATERIALS AND METHODS: An anthropomorphic male phantom validated for human organ dosimetry measurements was used to determine radiation doses. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations to measure specific organ doses. For each study the phantom was scanned 3 times using our institutional protocols. Organ doses were measured and effective doses were calculated on dosimetry. Effective doses measured by a metal oxide semiconductor field effect transistor dosimeter were compared to calculated effective doses derived from the dose-length product. RESULTS: The mean±SD effective dose on dosimetry for stone protocol, chest and abdominopelvic computerized tomography, computerized tomography urogram and renal cell carcinoma protocol computerized tomography was 3.04±0.34, 4.34±0.27, 5.19±0.64, 9.73±0.71 and 11.42±0.24 mSv, respectively. The calculated effective dose for these studies Was 3.33, 2.92, 5.84, 9.64 and 10.06 mSv, respectively (p=0.8478). CONCLUSIONS: The effective dose varies considerable for different urological computerized tomography studies. Renal stone protocol computerized tomography shows the lowest dose, and computerized tomography urogram and the renal cell carcinoma protocol accumulate the highest effective doses. The calculated effective dose derived from the dose-length product is a reasonable estimate of patient radiation exposure.


Assuntos
Técnicas de Diagnóstico Urológico/normas , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/normas , Humanos , Masculino
7.
AJR Am J Roentgenol ; 201(5): W730-4, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24063388

RESUMO

OBJECTIVE: The purpose of this study was to measure the organ doses and estimate the effective dose for the standard brain perfusion CT protocol and erroneous protocols. MATERIALS AND METHODS: An anthropomorphic phantom with metal oxide semiconductor field effect transistor (MOSFET) detectors was scanned on a 64-MDCT scanner. Protocol 1 used a standard brain perfusion protocol with 80 kVp and fixed tube current of 200 mA. Protocol 2 used 120 kVp and fixed tube current of 200 mA. Protocol 3 used 120 kVp with automatic tube current modulation (noise index, 2.4; minimum, 100 mA; maximum, 520 mA). RESULTS: Compared with protocol 1, the effective dose was 2.8 times higher with protocol 2 and 7.8 times higher with protocol 3. For all protocols, the peak dose was highest in the skin, followed by the brain and calvarial marrow. Compared with protocol 1, the peak skin dose was 2.6 times higher with protocol 2 and 6.7 times higher with protocol 3. The peak skin dose for protocol 3 exceeded 3 Gy. The ocular lens received significant scatter radiation: 177 mGy for protocol 2 and 435 mGy for protocol 3, which were 4.6 and 11.3 times the dose for protocol 1, respectively. CONCLUSION: Compared with the standard protocol, erroneous protocols of increasing the tube potential from 80 kVp to 120 kVp will lead to a three- to fivefold increase in organ doses, and concurrent use of high peak kilovoltage with incorrectly programmed tube current modulation can increase dose to organs by 7- to 11-fold. Tube current modulation with a low noise index can lead to doses to the skin and ocular lens that are close to thresholds for tissue reactions.


Assuntos
Encéfalo/diagnóstico por imagem , Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação
8.
Pediatr Radiol ; 43(9): 1117-27, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23636537

RESUMO

BACKGROUND: Advanced multidetector CT systems facilitate volumetric image acquisition, which offers theoretic dose savings over helical acquisition with shorter scan times. OBJECTIVE: Compare effective dose (ED), scan duration and image noise using 320- and 64-detector CT scanners in various acquisition modes for clinical chest, abdomen and pelvis protocols. MATERIALS AND METHODS: ED and scan durations were determined for 64-detector helical, 160-detector helical and volume modes under chest, abdomen and pelvis protocols on 320-detector CT with adaptive collimation and 64-detector helical mode on 64-detector CT without adaptive collimation in a phantom representing a 5-year-old child. Noise was measured as standard deviation of Hounsfield units. RESULTS: Compared to 64-detector helical CT, all acquisition modes on 320-detector CT resulted in lower ED and scan durations. Dose savings were greater for chest (27-46%) than abdomen/pelvis (18-28%) and chest/abdomen/pelvis imaging (8-14%). Noise was similar across scanning modes, although some protocols on 320-detector CT produced slightly higher noise. CONCLUSION: Dose savings can be achieved for chest, abdomen/pelvis and chest/abdomen/pelvis examinations on 320-detector CT compared to helical acquisition on 64-detector CT, with shorter scan durations. Although noise differences between some modes reached statistical significance, this is of doubtful diagnostic significance and will be studied further in a clinical setting.


Assuntos
Artefatos , Imageamento Tridimensional/instrumentação , Imagens de Fantasmas , Doses de Radiação , Radiometria , Tomografia Computadorizada Espiral/instrumentação , Imagem Corporal Total/instrumentação , Criança , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
9.
J Urol ; 187(3): 920-4, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22264465

RESUMO

PURPOSE: We measured organ specific radiation dose rates and determined effective dose rates during simulated ureteroscopy using a validated model. To calculate the effective dose, patients were exposed to ureteroscopic management of stones at our institution. MATERIALS AND METHODS: A validated anthropomorphic male phantom was placed on a fluoroscopy table and underwent simulated ureteroscopy. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ sites in the phantom and used to measure organ specific radiation doses. These dose rates were multiplied by the appropriate tissue weighting factor and summed to calculate effective dose rates. Also, we retrospectively reviewed the charts of patients who underwent ureteroscopy at our institution. A total of 30 nonobese males with data on fluoroscopy time were included in analysis. The median effective dose was determined by multiplying median fluoroscopy time by the effective dose rate. RESULTS: The skin entrance was exposed to the highest absorbed dose rate, followed by the small intestine (mean ± SD 0.3286 ± 0.0054 and 0.1882 ± 0.0194 mGy per second, respectively). The mean effective dose rate was 0.024 ± 0.0019 mSv per second. Median fluoroscopy time was 46.95 seconds (range 12.9 to 298.8). The median effective dose was 1.13 mSv (range 0.31 to 7.17). CONCLUSIONS: The fluoroscopy used during ureteroscopy contributes to overall radiation exposure in patients with nephrolithiasis. Nonobese males are exposed to a median of 1.13 mSv during ureteroscopy, similar to that of abdominopelvic x-ray. More data are needed to determine clinical implications but urologists must be aware and decrease patient radiation during ureteroscopy.


Assuntos
Doses de Radiação , Ureteroscopia , Urolitíase/diagnóstico por imagem , Carga Corporal (Radioterapia) , Humanos , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Radiografia , Estudos Retrospectivos , Fatores de Tempo , Ureter/efeitos da radiação , Bexiga Urinária/efeitos da radiação
10.
AJR Am J Roentgenol ; 198(3): 621-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22358002

RESUMO

OBJECTIVE: The purpose of this study was to assess the effect of peak kilovoltage on radiation dose and image quality in adult neck MDCT. MATERIALS AND METHODS: An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was imaged with a 64-MDCT scanner. The reference CT protocol called for 120 kVp, and images obtained with that protocol were compared with CT images obtained with protocols entailing 80, 100, and 140 kVp. All imaging was performed with automatic tube current modulation. Organ dose and effective dose were determined for each protocol and compared with those obtained with the 120-kVp protocol. Image noise was evaluated objectively and subjectively for each protocol. RESULTS: The highest organ doses for all protocols were to the thyroid, ocular lens, skin, and mandible. The greatest reductions in organ dose were for the bone marrow of the cervical spine and mandible: 43% and 35% with the 100-kVp protocol and 63% and 53% with the 80-kVp protocol. Effective dose decreased as much as 9% with the 100-kVp protocol and 12% with the 80-kVp protocol. Use of the 140-kVp protocol was associated with an increase in organ dose as high as 64% for bone marrow in the cervical spine and a 19% increase in effective dose. Image noise increased with lower peak kilovoltage. The measured noise difference was greatest at 80 kVp, absolute increases were less than 2.5 HU. There was no difference in subjective image quality among protocols. CONCLUSION: Reducing the voltage from 120 to 80 kVp for neck CT can result in greater than 50% reduction in the absorbed organ dose to the bone marrow of the cervical spine and mandible without impairment in subjective image quality.


Assuntos
Pescoço/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Adulto , Humanos , Imagens de Fantasmas , Doses de Radiação , Proteção Radiológica , Interpretação de Imagem Radiográfica Assistida por Computador , Valores de Referência
11.
AJR Am J Roentgenol ; 199(5): 1129-35, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23096189

RESUMO

OBJECTIVE: The purpose of this study is to determine patient dose estimates for clinical pediatric cardiac-gated CT angiography (CTA) protocols on a 320-MDCT volume scanner. MATERIALS AND METHODS: Organ doses were measured using 20 metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Radiation dose was estimated for volumetrically acquired clinical pediatric prospectively and retrospectively ECG-gated cardiac CTA protocols in 5-year-old and 1-year-old anthropomorphic phantoms on a 320-MDCT scanner. Simulated heart rates of 60 beats/min (5-year-old phantom) and 120 beats/min (1- and 5-year-old phantoms) were used. Effective doses (EDs) were calculated using average measured organ doses and International Commission on Radiological Protection 103 tissue-weighting factors. Dose-length product (DLP) was recorded for each examination and was used to develop dose conversion factors for pediatric cardiac examinations acquired with volume scan mode. DLP was also used to estimate ED according to recently published dose conversion factors for pediatric helical chest examinations. Repeated measures and paired Student t test analyses were performed. RESULTS: For the 5-year-old phantom, at 60 beats/min, EDs ranged from 1.2 mSv for a prospectively gated examination to 4.5 mSv for a retrospectively gated examination. For the 5-year-old phantom, at 120 beats/min, EDs ranged from 3.0 mSv for a prospectively gated examination to 4.9 mSv for a retrospectively gated examination. For the 1-year-old phantom, at 120 beats/min, EDs ranged from 2.7 mSv for a prospectively gated examination to 4.5 mSv for a retrospectively gated examination. CONCLUSION: EDs for 320-MDCT volumetrically acquired ECG-gated pediatric cardiac CTA are lower than those published for conventional 16- and 64-MDCT scanners.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária/métodos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Carga Corporal (Radioterapia) , Calibragem , Pré-Escolar , Humanos , Lactente , Estudos Prospectivos , Estudos Retrospectivos
12.
AJR Am J Roentgenol ; 198(5): 1132-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22528904

RESUMO

OBJECTIVE: The purpose of this study was to assess the difference in absorbed organ dose and image quality for MDCT neck protocols using automatic tube current modulation alone compared with organ-based dose modulation and in-plane thyroid bismuth shielding. MATERIALS AND METHODS: An anthropomorphic female phantom with metal oxide semiconductor field effect transistor (MOSFET) detectors was scanned on a 64-MDCT scanner. The protocols included a reference neck CT protocol using automatic tube current modulation and three modified protocols: organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield. Image noise was evaluated quantitatively with the SD of the attenuation value, and subjectively by two neuroradiologists. RESULTS: Organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield protocols reduced the thyroid dose by 28%, 33%, and 45%, respectively, compared with the use of automatic tube current modulation alone (p ≤ 0.005). Organ-based dose modulation also reduced the radiation dose to the ocular lens (33-47%) compared with the use of automatic tube current modulation (p ≤ 0.04). There was no significant difference in measured noise and subjective image quality between the protocols. CONCLUSION: Both organ-based dose modulation and thyroid shields significantly reduce the thyroid organ dose without degradation of subjective image quality compared with automatic tube current modulation. Organ-based dose modulation has the additional benefit of dose reduction to the ocular lens.


Assuntos
Doses de Radiação , Proteção Radiológica/instrumentação , Glândula Tireoide/efeitos da radiação , Tomografia Computadorizada por Raios X , Carga Corporal (Radioterapia) , Feminino , Humanos , Pescoço , Imagens de Fantasmas , Radiometria , Software
13.
AJR Am J Roentgenol ; 199(1): W65-73, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22733933

RESUMO

OBJECTIVE: The purpose of this study was to assess the radiation dose distribution and image quality for organ-based dose modulation during adult thoracic MDCT. MATERIALS AND METHODS: Organ doses were measured using an anthropomorphic adult female phantom containing 30 metal oxide semiconductor field-effect transistor detectors on a dual-source MDCT scanner with two protocols: standard tube current modulation thoracic CT and organ-based dose modulation using a 120° radial arc. Radiochromic film measured the relative axial dose. Noise was measured to evaluate image quality. Breast tissue location across the anterior aspect of the thorax was retrospectively assessed in 100 consecutive thoracic MDCT examinations. RESULTS: There was a 17-47% decrease (p = < 0.05) in anterior thoracic organ dose and a maximum 52% increase (p = < 0.05) in posterior thoracic organ dose using organ-based dose modulation compared with tube current modulation. Effective dose (SD) for tube current modulation and organ-based dose modulation were 5.25 ± 0.36 mSv and 4.42 ± 0.30 mSv, respectively. Radiochromic film analysis showed a 30% relative midline anterior-posterior gradient. There was no statistically significant difference in image noise. Adult female breast tissue was located within an average anterior angle of 155° (123-187°). CONCLUSION: Organ-based dose modulation CT using an anterior 120° arc can reduce the organ dose in the anterior aspect of the thorax with a compensatory organ dose increase posteriorly without impairment of image quality. Laterally located breast tissue will have higher organ doses than medially located breast tissue when using organ-based dose modulation. The benefit of this dose reduction must be clinically determined on the basis of the relationship of the irradiated organs to the location of the prescribed radial arc used in organ-based dose modulation.


Assuntos
Exposição Ambiental/análise , Doses de Radiação , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica , Dosagem Radioterapêutica , Estudos Retrospectivos , Tórax , Adulto Jovem
14.
Med Phys ; 38(1): 397-407, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21361208

RESUMO

PURPOSE: Radiation-dose awareness and optimization in CT can greatly benefit from a dose-reporting system that provides dose and risk estimates specific to each patient and each CT examination. As the first step toward patient-specific dose and risk estimation, this article aimed to develop a method for accurately assessing radiation dose from CT examinations. METHODS: A Monte Carlo program was developed to model a CT system (LightSpeed VCT, GE Healthcare). The geometry of the system, the energy spectra of the x-ray source, the three-dimensional geometry of the bowtie filters, and the trajectories of source motions during axial and helical scans were explicitly modeled. To validate the accuracy of the program, a cylindrical phantom was built to enable dose measurements at seven different radial distances from its central axis. Simulated radial dose distributions in the cylindrical phantom were validated against ion chamber measurements for single axial scans at all combinations of tube potential and bowtie filter settings. The accuracy of the program was further validated using two anthropomorphic phantoms (a pediatric one-year-old phantom and an adult female phantom). Computer models of the two phantoms were created based on their CT data and were voxelized for input into the Monte Carlo program. Simulated dose at various organ locations was compared against measurements made with thermoluminescent dosimetry chips for both single axial and helical scans. RESULTS: For the cylindrical phantom, simulations differed from measurements by -4.8% to 2.2%. For the two anthropomorphic phantoms, the discrepancies between simulations and measurements ranged between (-8.1%, 8.1%) and (-17.2%, 13.0%) for the single axial scans and the helical scans, respectively. CONCLUSIONS: The authors developed an accurate Monte Carlo program for assessing radiation dose from CT examinations. When combined with computer models of actual patients, the program can provide accurate dose estimates for specific patients.


Assuntos
Método de Monte Carlo , Neoplasias Induzidas por Radiação/etiologia , Medicina de Precisão/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Adulto , Feminino , Humanos , Lactente , Imagens de Fantasmas , Medição de Risco , Dosimetria Termoluminescente
15.
Med Phys ; 38(1): 408-19, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21361209

RESUMO

PURPOSE: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. METHODS: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GE Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient's clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDIvol) and the effective dose derived from the dose-length product (DLP). RESULTS: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller patients. However, the overall risk of cancer incidence attributable to the CT examination was much higher for the newborn (2.4 in 1000) than for the teenager (0.7 in 1000). For the two pediatric-aged patients in our study, CTDIvol underestimated dose to large organs in the scan coverage by 30%-48%. The effective dose derived from DLP using published conversion coefficients differed from that calculated using patient-specific organ dose values by -57% to 13%, when the tissue weighting factors of ICRP 60 were used, and by -63% to 28%, when the tissue weighting factors of ICRP 103 were used. CONCLUSIONS: It is possible to estimate patient-specific radiation dose and cancer risk from CT examinations by combining a validated Monte Carlo program with patient-specific anatomical models that are derived from the patients' clinical CT data and supplemented by transformed models of reference adults. With the construction of a large library of patient-specific computer models encompassing patients of all ages and weight percentiles, dose and risk can be estimated for any patient prior to or after a CT examination. Such information may aid in decisions for image utilization and can further guide the design and optimization of CT technologies and scan protocols.


Assuntos
Neoplasias Induzidas por Radiação/etiologia , Medicina de Precisão/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Adulto , Criança , Feminino , Humanos , Lactente , Masculino , Órgãos em Risco/efeitos da radiação , Medição de Risco
16.
Med Phys ; 38(6): 3232-45, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21815398

RESUMO

PURPOSE: A dual modality SPECT-CT prototype system dedicated to uncompressed breast imaging (mammotomography) has been developed. The computed tomography subsystem incorporates an ultrathick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam that optimizes the dose efficiency of the system for lesion imaging in an uncompressed breast. Here, the absorbed dose in various geometric phantoms and in an uncompressed and pendant cadaveric breast using a normal tomographic cone beam imaging protocol is characterized using both thermoluminescent dosimeter (TLD) measurements and ionization chamber-calibrated radiochromic film. METHODS: Initially, two geometric phantoms and an anthropomorphic breast phantom are filled in turn with oil and water to simulate the dose to objects that mimic various breast shapes having effective density bounds of 100% fatty and glandular breast compositions, respectively. Ultimately, an excised human cadaver breast is tomographically scanned using the normal tomographic imaging protocol, and the dose to the breast tissue is evaluated and compared to the earlier phantom-based measurements. RESULTS: Measured trends in dose distribution across all breast geometric and anthropomorphic phantom volumes indicate lower doses in the medial breast and more proximal to the chest wall, with consequently higher doses near the lateral peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes due to the reduced mass energy-absorption coefficient of oil relative to water. The mean measured dose to the breast cadaver, composed of adipose and glandular tissues, was measured to be 4.2 mGy compared to a mean whole-breast dose of 3.8 and 4.5 mGy for the oil- and water-filled anthropomorphic breast phantoms, respectively. CONCLUSIONS: Assuming rotational symmetry due to the tomographic acquisition exposures, these results characterize the 3D dose distributions in an uncompressed human breast tissue volume for this dedicated breast imaging device and illustrate advantages of using the novel ultrathick K-edge filtered beam to minimize the dose to the breast during fully-3D imaging.


Assuntos
Mama/efeitos da radiação , Dosimetria Fotográfica/métodos , Mamografia/instrumentação , Doses de Radiação , Calibragem , Cor , Feminino , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Dosimetria Termoluminescente
17.
AJR Am J Roentgenol ; 197(4): 778-82, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21940563

RESUMO

OBJECTIVE: The purpose of this article is to compare the radiation dose of conventional fluoroscopy-guided lumbar epidural steroid injections (ESIs) and CT fluoroscopy (CTF)-guided lumbar ESI using both clinical data and anthropomorphic phantoms. MATERIALS AND METHODS: We performed a retrospective review of dose parameters for 14 conventional fluoroscopy ESI procedures performed by one proceduralist and 42 CTF-guided ESIs performed by three proceduralists (14 each). By use of imaging techniques similar to those for our clinical cohorts, a commercially available anthropomorphic male phantom with metal oxide semiconductor field effect transistor detectors was scanned to obtain absorbed organ doses for conventional fluoroscopy-guided and CTF-guided ESIs. Effective dose (ED) was calculated from measured organ doses. RESULTS: The mean conventional fluoroscopy time for ESI was 37 seconds, and the mean procedural CTF time was 4.7 seconds. Calculated ED for conventional fluoroscopy was 0.85 mSv compared with 0.45 mSv for CTF. The greatest contribution to the radiation dose from CTF-guided ESI came from the planning lumbar spine CT scan, which had an ED of 2.90 mSv when z-axis ranged from L2 to S1. This resulted in a total ED for CTF-guided ESI (lumbar spine CT scan plus CTF) of 3.35 mSv. CONCLUSION: The ED for the CTF-guided ESI was almost half that of conventional fluoroscopy because of the shorter fluoroscopy time. However, the overall radiation dose for CTF-guided ESIs can be up to four times higher when a full diagnostic lumbar CT scan is performed as part of the procedure. Radiation dose reduction for CTF-guided ESI is best achieved by minimizing the dose from the preliminary planning lumbar spine CT scan.


Assuntos
Fluoroscopia/métodos , Injeções Epidurais , Injeções Espinhais , Dor Lombar/tratamento farmacológico , Doses de Radiação , Radiografia Intervencionista/métodos , Esteroides/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Vértebras Lombares , Masculino , Imagens de Fantasmas , Estudos Retrospectivos , Fatores de Tempo
18.
J Appl Clin Med Phys ; 12(2): 3395, 2011 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-21587186

RESUMO

Dosimetry in kilovoltage cone beam computed tomography (CBCT) is a challenge due to the limitation of physical measurements. To address this, we used a Monte Carlo (MC) method to estimate the CT dose index (CTDI) and the dose length product (DLP) for a commercial CBCT system. As Dixon and Boone showed that CTDI concept can be applicable to both CBCT and conventional CT, we evaluated weighted CT dose index (CTDI(w)) and DLP for a commercial CBCT system. Two extended CT phantoms were created in our BEAMnrc/EGSnrc MC system. Before the simulations, the beam collimation of a Varian On-Board Imager (OBI) system was measured with radiochromic films (model: XR-QA). The MC model of the OBI X-ray tube, validated in a previous study, was used to acquire the phase space files of the full-fan and half-fan cone beams. Then, DOSXYZnrc user code simulated a total of 20 CBCT scans for the nominal beam widths from 1 cm to 10 cm. After the simulations, CBCT dose profiles at center and peripheral locations were extracted and integrated (dose profile integral, DPI) to calculate the CTDI per each beam width. The weighted cone-beam CTDI (CTDI(w,l)) was calculated from DPI values and mean CTDI(w,l) (CTDI(w,l)) and DLP were derived. We also evaluated the differences of CTDI(w) values between MC simulations and point dose measurements using standard CT phantoms. In results, it was found that CTDI(w,600) was 8.74 ± 0.01 cGy for head and CTDI(w,900) was 4.26 ± 0.01 cGy for body scan. The DLP was found to be proportional to the beam collimation. We also found that the point dose measurements with standard CT phantoms can estimate the CTDI within 3% difference compared to the full integrated CTDI from the MC method. This study showed the usability of CTDI as a dose index and DLP as a total dose descriptor in CBCT scans.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Calibragem , Simulação por Computador , Desenho de Equipamento , Dosimetria Fotográfica/métodos , Humanos , Modelos Estatísticos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação
19.
Radiology ; 254(1): 145-53, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20032149

RESUMO

PURPOSE: To investigate whether an adaptive statistical iterative reconstruction (ASIR) algorithm improves the image quality at low-tube-voltage (80-kVp), high-tube-current (675-mA) multidetector abdominal computed tomography (CT) during the late hepatic arterial phase. MATERIALS AND METHODS: This prospective, single-center HIPAA-compliant study was institutional review board approved. Informed patient consent was obtained. Ten patients (six men, four women; mean age, 63 years; age range, 51-77 years) known or suspected to have hypervascular liver tumors underwent dual-energy 64-section multidetector CT. High- and low-tube-voltage CT images were acquired sequentially during the late hepatic arterial phase of contrast enhancement. Standard convolution FBP was used to reconstruct 140-kVp (protocol A) and 80-kVp (protocol B) image sets, and ASIR (protocol C) was used to reconstruct 80-kVp image sets. The mean image noise; contrast-to-noise ratio (CNR) relative to muscle for the aorta, liver, and pancreas; and effective dose with each protocol were assessed. A figure of merit (FOM) was computed to normalize the image noise and CNR for each protocol to effective dose. Repeated-measures analysis of variance with Bonferroni adjustment for multiple comparisons was used to compare differences in mean CNR, image noise, and corresponding FOM among the three protocols. The noise power spectra generated from a custom phantom with each protocol were also compared. RESULTS: When image noise was normalized to effective dose, protocol C, as compared with protocols A (P = .0002) and B (P = .0001), yielded an approximately twofold reduction in noise. When the CNR was normalized to effective dose, protocol C yielded significantly higher CNRs for the aorta, liver, and pancreas than did protocol A (P = .0001 for all comparisons) and a significantly higher CNR for the liver than did protocol B (P = .003). Mean effective doses were 17.5 mSv +/- 0.6 (standard error) with protocol A and 5.1 mSv +/- 0.3 with protocols B and C. Compared with protocols A and B, protocol C yielded a small but quantifiable noise reduction across the entire spectrum of spatial frequencies. CONCLUSION: Compared with standard FBP reconstruction, an ASIR algorithm improves image quality and has the potential to decrease radiation dose at low-tube-voltage, high-tube-current multidetector abdominal CT during the late hepatic arterial phase.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Idoso , Algoritmos , Análise de Variância , Meios de Contraste/administração & dosagem , Feminino , Humanos , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Abdominal/instrumentação
20.
Radiology ; 256(2): 450-9, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20656835

RESUMO

PURPOSE: To intraindividually compare a low-tube-voltage (80 kVp), high-tube-current (675 mA) computed tomographic (CT) technique with a high-tube-voltage (140 kVp) CT protocol for the detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase. MATERIALS AND METHODS: This prospective, single-center, HIPAA-compliant study was approved by the institutional review board, and written informed consent was obtained. Twenty-seven patients (nine men, 18 women; mean age, 64 years) with 23 solitary pancreatic tumors underwent dual-energy CT. Two imaging protocols were used: 140 kVp and 385 mA (protocol A) and 80 kVp and 675 mA (protocol B). For both protocols, the following variables were compared during the pancreatic parenchymal phase: contrast enhancement for the aorta, the pancreas, and the portal vein; pancreas-to-tumor contrast-to-noise ratio (CNR); noise; and effective dose. Two blinded, independent readers qualitatively scored the two data sets for tumor detection and image quality. Random-effect analysis of variance tests were used to compare differences between the two protocols. RESULTS: Compared with protocol A, protocol B yielded significantly higher contrast enhancement for the aorta (508.6 HU vs 221.5 HU, respectively), pancreas (151.2 HU vs 67.0 HU), and portal vein (189.7 HU vs 87.3 HU), along with a greater pancreas-to-tumor CNR (8.1 vs 5.9) (P < .001 for all comparisons). No statistically significant difference in tumor detection was observed between the two protocols. Although standard deviation of image noise increased with protocol B (11.5 HU vs 18.6 HU), this protocol significantly reduced the effective dose (from 18.5 to 5.1 mSv; P < .001). CONCLUSION: A low-tube-voltage, high-tube-current CT technique has the potential to improve the enhancement of the pancreas and peripancreatic vasculature, improve tumor conspicuity, and reduce patient radiation dose during the pancreatic parenchymal phase.


Assuntos
Carga Corporal (Radioterapia) , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA