Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(2)2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35062593

RESUMO

Research on stretchable strain sensors is actively conducted due to increasing interest in wearable devices. However, typical studies have focused on improving the elasticity of the electrode. Therefore, methods of directly connecting wire or attaching conductive tape to materials to detect deformation have been used to evaluate the performance of strain sensors. Polyaniline (PANI), a p-type semiconductive polymer, has been widely used for stretchable electrodes. However, conventional procedures have limitations in determining an appropriate metal for ohmic contact with PANI. Materials that are generally used for connection with PANI form an undesirable metal-semiconductor junction and have significant contact resistance. Hence, they degrade sensor performance. This study secured ohmic contact by adapting Au thin film as the metal contact layer (the MCL), with lower contact resistance and a larger work function than PANI. Additionally, we presented a buffer layer using hard polydimethylsiloxane (PDMS) and structured it into a dumbbell shape to protect the metal from deformation. As a result, we enhanced steadiness and repeatability up to 50% strain by comparing the gauge factors and the relative resistance changes. Consequently, adapting structural methods (the MCL and the dumbbell shape) to a device can result in strain sensors with promising stability, as well as high stretchability.

2.
Sensors (Basel) ; 22(7)2022 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-35408355

RESUMO

Stretchable strain sensors are capable of acquiring data when in contact with human skin or equipment and are widely used in wearable applications. Most strain sensors have tensile properties of less than 20% and have limitations regarding body motion linkage, complex sensor structure, and motion nonreliability. To address these problems, we developed a high tension and high sensitivity sensor with a gauge factor over 40 and tensile stress about 50%. Polydimethylsiloxane (PDMS) was selected as the flexible substrate to ensure tensile strength, and polyaniline (PANI) was used to measure the resistance changes in the sensor. In particular, problems regarding poor uniformity of PANI on PDMS were resolved by surface treatment of the PDMS, wherein PANI polymerization was performed sequentially after forming a self-assembled monolayer (SAM) on the PDMS substrate. O2 plasma and (3-aminopropyl)triethoxysilane were used to form the SAM. It is expected that this sensor can obtain stable characteristics even under high tensile stress through the evenly formed PANI films on the surface-treated PDMS substrate and may be used in various flexible sensor applications.


Assuntos
Dimetilpolisiloxanos , Compostos de Anilina , Dimetilpolisiloxanos/química , Humanos , Polimerização , Propilaminas , Silanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA