Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
ScientificWorldJournal ; 2014: 108492, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24688358

RESUMO

The stress-strain data of 20MnNiMo alloy were collected from a series of hot compressions on Gleeble-1500 thermal-mechanical simulator in the temperature range of 1173 ∼ 1473 K and strain rate range of 0.01 ∼ 10 s(-1). Based on the experimental data, the improved Arrhenius-type constitutive model and the artificial neural network (ANN) model were established to predict the high temperature flow stress of as-cast 20MnNiMo alloy. The accuracy and reliability of the improved Arrhenius-type model and the trained ANN model were further evaluated in terms of the correlation coefficient (R), the average absolute relative error (AARE), and the relative error (η). For the former, R and AARE were found to be 0.9954 and 5.26%, respectively, while, for the latter, 0.9997 and 1.02%, respectively. The relative errors (η) of the improved Arrhenius-type model and the ANN model were, respectively, in the range of -39.99% ∼ 35.05% and -3.77% ∼ 16.74%. As for the former, only 16.3% of the test data set possesses η-values within ± 1%, while, as for the latter, more than 79% possesses. The results indicate that the ANN model presents a higher predictable ability than the improved Arrhenius-type constitutive model.


Assuntos
Manganês/química , Modelos Químicos , Modelos Moleculares , Molibdênio/química , Redes Neurais de Computação , Níquel/química , Algoritmos , Ligas/química , Força Compressiva , Simulação por Computador , Difusão , Módulo de Elasticidade , Cinética , Transição de Fase , Resistência à Tração , Condutividade Térmica , Viscosidade
2.
Zhonghua Wai Ke Za Zhi ; 42(9): 562-5, 2004 May 07.
Artigo em Zh | MEDLINE | ID: mdl-15196373

RESUMO

OBJECTIVE: To establish the modal of perfusing and casting in hepatic duct system and explore the methods of three dimensional reconstruction with CT scanning image after filling hepatic duct. METHODS: All canal of livers with integral porta hepatic were perfused with various filling material after pretreatment, then fixed and casted. Hepatic preparations that had been perfused were put into the model of modelling abdominal cavity and scanned with thin slice. The three dimensional duct structures of hepatic with three methods of MIP, SSD and computerized treatment. RESULTS: Fourteen hepatic samples were filled and casted. Nine hepatic samples were scanned with slice height 1.0 mm, all 2514 slice images and average 279 images. Five hepatic samples were scanned with slice height 3.0 mm, all 512 slice images and average 102 images. Intrahepatic vein and portal vein system of three dimensional reconstruction were seen clearly with MIP method. The three dimensional established three dimensional images with SSD method was shown much stronger than that of MIP method. The three dimensional images of hepatic solid and hepatic vein system were established with method of comperized treatment. Vary three dimensional shape of hepatic solid and hepatic vein was obtained through different direction rotational. CONCLUSIONS: The modal filled and casted hepatic duct system were practise. The images established three dimensional with methods of MIP, SSD and comperized treatment were seen clearly. The modal and images of thin slice CT scanning are a better method for researching hepatic duct system.


Assuntos
Imageamento Tridimensional/métodos , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Humanos , Técnicas In Vitro , Fígado/anatomia & histologia
3.
Nan Fang Yi Ke Da Xue Xue Bao ; 26(8): 1197-9, 2006 Aug.
Artigo em Zh | MEDLINE | ID: mdl-16939920

RESUMO

The mechanics of a new shape memory alloy cervical hook for atlantoaxial instability was analyzed with finite element method on the basis of a three-dimensional model reconstructed from the images of CT scanning of an adult cadaveric upper cervical at 1-mm interval. The stress and displacement of every nodule and element in the course of deformation of the internal fixation were tested, and the results showed that the cervical hook was strong enough against tensile stress, which concentrates in the middle of the device. The pull was 237.58 N at the loading point. With such mechanical performance, this cervical hook can be reliable for correction of atlantoaxial instability.


Assuntos
Articulação Atlantoaxial , Análise de Elementos Finitos , Instabilidade Articular/cirurgia , Dispositivos de Fixação Ortopédica/normas , Adulto , Ligas , Cadáver , Humanos , Instabilidade Articular/diagnóstico por imagem , Masculino , Memória , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/métodos , Radiografia , Reprodutibilidade dos Testes , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA