RESUMO
Endovascular mechanical thrombectomy is a new standard of care for acute ischemic stroke (AIS). The majority of these patients receive mechanical ventilation (MV), which has been associated with poor outcomes. The implication of this is significant, as most neurointerventionalists prefer general compared to local anesthesia during the procedure. Consequences of hemodynamic and respiratory perturbations during general anesthesia and MV are thought to contribute significantly to the poor outcomes that are encountered. In this review, we first describe the unique risks associated with MV in the specific context of AIS and then discuss evidence of brain goal-directed approaches that may mitigate these risks. These strategies include an individualized approach to hemodynamic parameters (eg, adherence to a minimum blood pressure goal and adequate volume resuscitation), respiratory parameters (eg, arterial carbon dioxide optimization), and the use of ventilator settings that optimize neurological outcomes (eg, arterial oxygen optimization).
Assuntos
Isquemia Encefálica/cirurgia , Respiração Artificial , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Pressão Sanguínea/fisiologia , Volume Sanguíneo/fisiologia , Isquemia Encefálica/fisiopatologia , Fibrinolíticos/uso terapêutico , Hemodinâmica/fisiologia , Humanos , Respiração Artificial/efeitos adversos , Acidente Vascular Cerebral/fisiopatologia , Terapia Trombolítica/métodosRESUMO
STUDY OBJECTIVE: To compare the C-MAC video laryngoscope to the standard flexible fiberoptic scope (FFS) with an eye piece (but without a camera or a video screen) for intubation of patients undergoing cervical spine surgery with manual inline stabilization. The primary end point was the time to achieve successful tracheal intubation. Secondary end points included glottic view at intubation and number of intubation attempts. DESIGN: Prospective, randomized, single-blinded study. SETTING: Cedars Sinai Medical Center in Los Angeles, CA. PATIENTS: One hundred forty patients (American Society of Anaesthesiologists physical status I-III), aged 18 to 80years undergoing elective cervical spine surgery. INTERVENTION: Patients were prospectively randomized to undergo tracheal intubation using either an FFS (n=70) or the C-MAC video laryngoscope (n=70). MEASUREMENTS: After performing a preoperative airway evaluation, patients underwent a standardized induction sequence. The glottic view was assessed at the time of tracheal tube placement using the Cormack-Lehane and percentage of glottic opening scoring systems. In addition, the time required for successful insertion of the tracheal tube, number of intubation attempts to secure the airway, the need for adjuvant airway devices, hemodynamic changes, adverse events, and any airway-related trauma were recorded. MAIN RESULTS: The glottic view at the time of intubation did not differ significantly with the 2 devices; however, the C-MAC facilitated more rapid tracheal intubation compared with the FFS (P=.001). The peak heart rate response following insertion of the tracheal tube was also reduced (P=.004) in the C-MAC (vs FFS) group. CONCLUSION: The C-MAC may offer an advantage over the FFS with respect to the time required to obtain glottic view and successful placement of the tracheal tube in patients requiring cervical spine immobilization.
Assuntos
Vértebras Cervicais/cirurgia , Tecnologia de Fibra Óptica/instrumentação , Intubação Intratraqueal/instrumentação , Laringoscópios , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Tecnologia de Fibra Óptica/métodos , Hemodinâmica/fisiologia , Humanos , Imobilização , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/métodos , Laringoscópios/efeitos adversos , Laringoscopia/efeitos adversos , Laringoscopia/instrumentação , Laringoscopia/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Fatores de Tempo , Adulto JovemRESUMO
INTRODUCTION: Therapeutic hypothermia (TH) after cardiac arrest (CA) resuscitation is the first therapy proven to increase survival to discharge and neurologic recovery. Methods for neurologic and mortality prognostication after CA resuscitation have been called into question because they were developed based on evidence that was developed prior to the advent of TH. This study examines the relationship between electroencephalogram (EEG) patterns and mortality and neurologic outcomes in post-CA patients undergoing TH. METHODS: Eighty-three of 732 patients who had continuous EEG (cEEG) monitoring during TH were included. Continuous EEG tracings were classified as isoelectric, low voltage, burst suppression, epileptic form, and diffuse slowing. Primary outcomes are survival to discharge and Cerebral Performance Categories (CPCs) at hospital discharge. RESULTS: Among patients with favorable neurologic outcomes (CPC1 and CPC2), the duration cardiopulmonary resuscitation and time until return of spontaneous circulation were shorter than observed in patients with poorer neurologic outcomes (CPC3, CPC4, and CPC5). The time to target temperature was equivalent among neurologic outcome groups (499.5 minutes vs 431.0 minutes, P = .09). Favorable neurologic outcome was associated with initial presentation with ventricular tachycardia or ventricular fibrillation and had cEEG patterns suggestive of diffuse slowing and epileptiform waves. DISCUSSION: The use of cEEG can provide prognostication information otherwise not obtainable by clinical examination. Specific cEEG patterns predicted probability of mortality for patients according to their initial rhythm of CA as a function of cardiopulmonary resuscitation time.
Assuntos
Eletroencefalografia , Parada Cardíaca/fisiopatologia , Parada Cardíaca/terapia , Hipotermia Induzida , Idoso , Temperatura Corporal , Reanimação Cardiopulmonar/métodos , Proteínas de Ligação a DNA , Proteínas de Drosophila , Feminino , Parada Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Taquicardia Ventricular/etiologia , Fatores de Tempo , Fatores de Transcrição , Fibrilação Ventricular/etiologiaRESUMO
BACKGROUND: Technologic advances and superior survival with mechanical circulatory support (MCS) have led to an expanding population that develops intraabdominal conditions requiring intervention. Whether laparoscopy can be performed without detrimental effects on hemodynamics and device function is not well described. MATERIALS AND METHODS: Effects of laparoscopy performed on MCS were retrospectively assessed. Intraoperative hemodynamics and device function were compared with the same time interval 24 hours prior to surgery using intrapatient paired t tests. Outcomes included survival, transfusion, thromboembolic events, and infection. RESULTS: Twelve patients with ventricular assist devices or total artificial hearts underwent laparoscopy from 2012 to 2014. Median follow-up was 116 days. Operations included cholecystectomy, diagnostic laparoscopy, gastrojejunostomy, and gastrostomy. There were no differences between preoperative and intraoperative mean arterial pressure, heart rate, and inotrope or vasopressor requirements (P > .05). Device fill volume, flow, rate, and power were unchanged (P > .05), whereas pulsatility index decreased by 0.2 (95% confidence interval, 0.03, 0.36) with laparoscopy (P = .03). All intraoperative fluctuations in hemodynamics and device function improved with reduction of pneumoperitoneum, adjusting device speed, or pharmacologic support. There were no operative mortalities. Thirty-day survival and survival to discharge were 75% and 50%, respectively. Despite antiplatelet therapy and preoperative international normalization ratio of 2.2 ± 0.9, there were no re-operations for bleeding, and 50% did not require transfusion. Two patients with recent cardiac surgery had thromboembolic events: one stroke and one device thrombus. None had postoperative bacteremia or driveline infection. CONCLUSIONS: Laparoscopy can be performed on MCS with low morbidity and mortality and minimal perturbations in hemodynamics and device function.