Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Electrochim Acta ; 246: 399-405, 2017 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-29104305

RESUMO

The main aim of the research was to design a functional impedimetric biosensor able to glycoprofile prostate specific antigen (PSA), a biomarker for prostate cancer (PCa), with high specificity using lectins as glycan recognising proteins. Traditionally, full-length antibody is immobilised on the biosensor interface for specific capture of PSA with subsequent glycoprofiling of PSA by addition of lectins. Since full-length antibodies contain glycans in the Fc domain, particular attention has to be paid to suppress direct binding of lectins to immobilised full-length antibodies, which would compromise accurate glycoprofiling. This issue is addressed here using a recombinant single-chain antibody fragments (scAb), which do not contain any carbohydrate moiety. Surface plasmon resonance was applied to prove negligible interaction of lectins with immobilised scAb fragments, while substantial binding of lectins to full length antibodies was observed. Eight different biosensor designs were tested for their ability to detect PSA. The biosensor device based on scAb fragments covalently immobilised on the gold electrode surface, patterned by a mixed SAM using standard amine coupling chemistry, proved to be the most sensitive. The scAb fragment-based biosensor exhibited sensitivity of 15.9 ± 0.8% decade-1 (R2 = 0.991 with an average RSD of 4.9%), while the full antibody-based biosensor offered sensitivity towards PSA of 4.2 ± 0.1% decade-1 (R2 = 0.999 with an average RSD of 4.8%). Moreover, the selectivity of the scAb-based biosensor was tested using a kallikrein 2 protein, a protein structurally similar to PSA, and the results indicated high selectivity for PSA detection.

2.
Biosens Bioelectron ; 106: 78-85, 2018 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-29414093

RESUMO

Assesment of human epidermal growth factor receptor 2 status is a key factor prompting definitive treatment decisions that help in reducing mortality rates associated with breast cancer. In this article, highly sensitive and low-cost impedimetric immunosensor using single-chain fragment variable antibody fragments was developed for quantitative detection of human epidermal growth factor receptor 2 from serum employing gold nanoparticle-modified disposable screen-printed carbon electrodes. The gold nanoparticles facilitate fast electron transfer and offer a biocompatible surface for immobilization of small antibody fragments in an oriented manner, resulting in improved antigen binding efficiency. The single-chain fragment variable antibody fragment-modified screen printed immunosensor exhibits wide dynamic range of 0.01-100 ng mL-1 and detection limit of 0.01 ng mL-1. The advantages offered by this platform in terms of high sensitivity, broad dynamic range and low-cost demonstrates great potential for improved monitoring of human epidermal growth factor receptor 2 levels for the management of breast and other cancers.


Assuntos
Técnicas Biossensoriais , Neoplasias da Mama/sangue , Imunoensaio , Receptor ErbB-2/isolamento & purificação , Anticorpos Imobilizados/imunologia , Carbono/química , Feminino , Ouro , Humanos , Nanopartículas Metálicas/química , Receptor ErbB-2/sangue
3.
Biotechnol Adv ; 35(2): 135-149, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27939303

RESUMO

The increased incidence and the significant health burden associated with carcinoma of the prostate have led to substantial changes in its diagnosis over the past century. Despite technological advancements, the management of prostate cancer has become progressively more complex and controversial for both early and late-stage disease. The limitations and potential harms associated with the use of prostate-specific antigen (PSA) as a diagnostic marker have stimulated significant investigation of numerous novel biomarkers that demonstrate varying capacities to detect prostate cancer and can decrease unnecessary biopsies. However, only a few of these markers have been approved for specific clinical settings while the others have not been adequately validated for use. This review systematically and critically assesses ongoing issues and emerging challenges in the current state of prostate cancer diagnostic tools and the need for disruptive next generation tools based on analysis of combinations of these biomarkers to enhance predictive accuracy which will benefit clinical diagnostics and patient welfare.


Assuntos
Biomarcadores Tumorais , Biópsia , Sistemas Automatizados de Assistência Junto ao Leito , Neoplasias da Próstata , Humanos , Masculino , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Kit de Reagentes para Diagnóstico
4.
PLoS One ; 11(7): e0159859, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27459092

RESUMO

Recent exploitation of the avian immune system has highlighted its suitability for the generation of high-quality, high-affinity antibodies to a wide range of antigens for a number of therapeutic and biotechnological applications. The glycosylation profile of potential immunoglobulin therapeutics is species specific and is heavily influenced by the cell-line/culture conditions used for production. Hence, knowledge of the carbohydrate moieties present on immunoglobulins is essential as certain glycan structures can adversely impact their physicochemical and biological properties. This study describes the detailed N-glycan profile of IgY polyclonal antibodies from the serum of leghorn chickens using a fully quantitative high-throughput N-glycan analysis approach, based on ultra-performance liquid chromatography (UPLC) separation of released glycans. Structural assignments revealed serum IgY to contain complex bi-, tri- and tetra-antennary glycans with or without core fucose and bisects, hybrid and high mannose glycans. High sialic acid content was also observed, with the presence of rare sialic acid structures, likely polysialic acids. It is concluded that IgY is heavily decorated with complex glycans; however, no known non-human or immunogenic glycans were identified. Thus, IgY is a potentially promising candidate for immunoglobulin-based therapies for the treatment of various infectious diseases.


Assuntos
Proteínas Aviárias/sangue , Imunoglobulinas/sangue , Polissacarídeos/metabolismo , Animais , Proteínas Aviárias/metabolismo , Galinhas , Feminino , Glicosilação , Imunoglobulinas/metabolismo , Ácido N-Acetilneuramínico/metabolismo , Processamento de Proteína Pós-Traducional
5.
Biosensors (Basel) ; 5(3): 577-601, 2015 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-26287254

RESUMO

The inability to diagnose numerous diseases rapidly is a significant cause of the disparity of deaths resulting from both communicable and non-communicable diseases in the developing world in comparison to the developed world. Existing diagnostic instrumentation usually requires sophisticated infrastructure, stable electrical power, expensive reagents, long assay times, and highly trained personnel which is not often available in limited resource settings. This review will critically survey and analyse the current lateral flow-based point-of-care (POC) technologies, which have made a major impact on diagnostic testing in developing countries over the last 50 years. The future of POC technologies including the applications of microfluidics, which allows miniaturisation and integration of complex functions that facilitate their usage in limited resource settings, is discussed The advantages offered by such systems, including low cost, ruggedness and the capacity to generate accurate and reliable results rapidly, are well suited to the clinical and social settings of the developing world.


Assuntos
Países em Desenvolvimento , Recursos em Saúde , Microfluídica/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Técnicas Biossensoriais/economia , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/normas , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Microfluídica/economia , Microfluídica/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA