Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Reumatologia ; 62(2): 121-127, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38799774

RESUMO

Introduction: Fracture of the proximal femur is common in elderly patients, in fact threatening their lives. Age-related sarcopenia may be involved in the imbalance resulting in the injury. Handy and readily accessible biochemical tests would be useful to assess the musculoskeletal system condition in daily practice. The aim of the study was to determine whether there is any relation between muscle decay and fracture of the proximal femur and to assess bone quality in elderly patients. Material and methods: In the study 22 patients who represented the treatment group were hospitalized due to proximal femur fracture. Eighteen patients from the control group with no fracture in their history were admitted to the Internal Medicine Department. Anyone treated for osteoporosis, immune disease affecting protein balance, neoplasm, mental illness, heart failure, or myocardial infarction was excluded from the study. In every case a blood sample from an elbow vein was drawn, collected in EDTA-K2 tubes, and then centrifuged to separate plasma from the whole blood. Subsequently, the concentrations of C-terminal cross-linked telopeptide of type I collagen (CTX-I), sex hormone binding globulin (SHBG) and creatine kinase (CK) in plasma were determined using commercial enzyme-linked immunosorbent assays. Results: The CK plasma concentration differed between the patient groups (p = 0.011). The SHBG plasma concentration was significantly higher in the treatment group (p = 0.006), whereas a slight difference in CTX-I plasma concentration between the groups was found (p = 0.038). No significant correlations between plasma CK, SHBG or CTX-I were found (p > 0.05). Conclusions: Creatine kinase is actually not an appropriate marker for the clinical assessment of muscle tissue quality in patients with or at risk of proximal femur fracture. Analyzing the quality of bone tissue, we can conclude it was poorer in patients with proximal femur fracture than in the control group.

2.
Reumatologia ; 62(2): 128-133, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38799773

RESUMO

Introduction: Total hip arthroplasty (THA) is nowadays considered as the most effective treatment option for end-stage hip osteoarthritis (OA) and one of the most successful orthopedic procedures. Precise reproduction of the center of rotation (COR) is among the most important aspects of recreating native hip biomechanics after THA as it is strictly related to muscle tension and force distribution within the hip joint. Both vertical and horizontal shift in cup positioning and COR restoration are commonly observed radiological signs corresponding with lesser functional outcome. The aim of this study was to assess whether the superior border of the native acetabulum morphology has an impact on cup positioning and COR restoration in patients undergoing THA as treatment of primary OA of the hip. Material and methods: A cohort of 150 consecutive patients with diagnosis of end-stage primary hip OA who underwent THA via an anterolateral approach with the same implant in 2021 was analyzed retrospectively. Standard standing pelvic X-rays were performed pre- and postoperatively and appropriate measurements were taken. Several radiological parameters on obtained X-rays were assessed. Statistical analysis of all the measurements was performed. Results: There was a statistically significant positive weak correlation between cup offset and acetabular roof angle (rs = 0.25, p = 0.002). There were statistically insignificant positive correlations between acetabular roof angle and COR restoration (rs = 0.14, p = 0.097), acetabular roof angle and total offset (rs = 0.087, p = 0.29) and a negative correlation between acetabular roof angle and femoral offset (rs = 0.071, p = 0.39). Conclusions: The present study revealed that preoperative acetabular roof angle influences the positioning of the prosthetic cup in the transverse axis. There also seems to be a correlation between the acetabular roof angle and COR restoration, but its significance needs further evaluation. Surgeons could use this knowledge to preoperatively assess the risk of cup malposition and adjust their technique during the THA procedure with probable improvement of hip function.

3.
BMC Musculoskelet Disord ; 24(1): 610, 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37491199

RESUMO

BACKGROUND: Total knee replacement (TKR) is considered one of the most common elective orthopaedic procedures. The main focus of TKR is to offer patient's symptomatic relief from persistent knee pain. To achieve this it is crucial to restore joint biomechanics by performing proper bone cuts. Some surgeons favor the measured resection technique, others prefer gap balancing technique. The researchers of the presented study performed TKR using these two techniques. The aim of this study was to compare the postoperative change in joint line and posterior condylar offset after TKR with use of anatomic knee design implants between gap balancing and measured resection techniques. METHODS: Two hundred twenty-five X-rays of patients who underwent TKR performed by a single surgeon between 2020 and 2021 were analyzed. The first group of patients (101) was operated with the use of gap balancing technique and the second group (124) was operated with the use of measured resection technique. Patients included in the study were > 50 years of age, had confirmed primary knee osteoarthritis, underwent primary TKR with a PS (posterior stabilized) knee implants without patella resurfacing and had at least 15 degree flexion contracture. T-student test and U Mann-Whitney test were used in statistical analysis of results, according to the normality of distribution examined with the Shapiro-Wilk test. Post-hoc analysis was performed using the Dwass-Steel-Crichtlow-Fligner test (DSCF). RESULTS: The postoperative analysis showed a significantly elevated joint line level in the gap balancing group (-2.6 ± 4.1 vs -0.7 ± 4.8, p < 0.0005). In the gap balancing group significantly more patients had joint lines elevated > 2 mm comparing to measured resection technique. The difference between pre- and postoperative PCO (posterior condylar offset) and PCOR (posterior condylar offset ratio) results had no significant differences (100.8 ± 11.8 vs 101 ± 12.5, p > 0.05) between the groups. CONCLUSIONS: The results of the study suggest that when it comes to restoring joint line level measured resection technique seems to be superior in comparison to the gap balancing technique. What is more, results indicate measured resection is equal in terms of restoring posterior condylar offset to the gap balancing technique. TRIAL REGISTRATION: NCT04164147, date of registration: November 14, 2019.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Pessoa de Meia-Idade , Artroplastia do Joelho/métodos , Estudos de Coortes , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
4.
Arch Orthop Trauma Surg ; 143(9): 5901-5907, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37000268

RESUMO

INTRODUCTION: During the last years, main attention while performing total knee replacement was paid to femoral component alignment; however, there is still lack of studies concerning tibial baseplate rotational alignment, especially in terms of anatomical designs of knee prosthesis. Some recent studies proved that tibial baseplate malrotation might be a cause of knee pain and patients' dissatisfaction. The aim of this study was to compare tibial component rotation and its coverage on the tibial plateau achieved with curve-on-curve and tibial tuberosity techniques (t-t technique) with use of anatomic knee designs with asymmetric tibial baseplate. MATERIALS AND METHODS: A total of 88 patients were randomly assigned in a 1:1 ratio to undergo total knee arthroplasty with use of the PERSONA PS (Zimmer Biomet) knee design with an asymmetric baseplate. The rotation of the tibial component was assessed and performed with two different techniques: curve-on-curve technique and tibial tuberosity technique. Tibial component rotation was measured on computed tomography (CT) scans using the method suggested by Benazzo et al. and designed for asymmetrical implants. For the measurement of the tibial bone coverage, the component surface area was outlined and measured on a proper CT section, then the tibial cut surface area was outlined and measured on a section just below the cement level. Pre- and post-operative range of motion was measured by another independent researcher 12 months post-operatively during follow-up visit. RESULTS: There was a statistically significant difference between both groups in median value of tibial rotation angle: 7° (interquartile range (IQR) = 0-12) in curve-on-curve technique group vs 2° (IQR-1-7) in tibial tuberosity technique group, probability value (p) = 0.0041, with values above 0 meaning external rotation of the component. There was no statistically significant difference between both groups in terms of range of motion (ROM) with average values of 124.3° ± 13.0° for curve-on-curve technique and 125.6° ± 12.8° for t-t technique with p = 0.45. There was a statistically insignificant difference between both groups in terms of coverage percentage in slight favor for curve-on-curve technique (85.9 ± 4.2 vs 84.5 ± 4.8, p = 0.17). CONCLUSION: In this study, no difference between the groups in terms of tibial bone coverage and range of motion was proved, even though both techniques differed significantly with values of tibial rotation. Future studies should be focused on influence of specific values of tibial rotation on patient-reported outcomes and survivorship of anatomic knee implants.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
5.
Medicina (Kaunas) ; 59(5)2023 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-37241112

RESUMO

Background and Objectives: Total knee arthroplasty (TKA) is the most effective treatment method for end-stage osteoarthritis. One of the most important aspects of this surgery is adequate implant positioning, as it guarantees the desired outcome of restoring limb biomechanics. Surgical technique is being continuously improved along with hardware development. There are two novel devices designed to help establish proper femoral component rotation: soft-tissue tensor and robotic-assisted TKA (RATKA). This study compared the femoral component rotation achieved with the use of three methods: RATKA, soft tissue tensioner and the conventional measured-resection technique, all of them utilizing anatomical design prosthesis components. Materials and Methods: A total of 139 patients diagnosed with end-stage osteoarthritis underwent total knee arthroplasty between December 2020 and June 2021. After the surgery, they were divided into three groups depending on procedure technique and implant type: Persona (Zimmer Biomet) + Fuzion Balancer, RATKA + Journey II BCS or conventional TKA + Persona/Journey. Postoperatively, a computed tomography examination was performed in order to measure femoral component rotation. All three groups were compared independently during statistical analysis. Fisher's exact, Kruskal-Wallis and Dwass-Steel-Crichtlow-Fligner tests were used for particular calculations. Results: Statistically significant differences in femoral component rotation between groups were noticed. However, in terms of values other than 0° in external rotation, no significant variance was revealed. Conclusions: Additional total knee arthroplasty instruments seem to improve the outcomes of the surgery, providing better component positioning than in the conventional measured-resection technique based only on bone landmarks.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Articulação do Joelho/cirurgia , Fêmur/cirurgia , Osteoartrite do Joelho/cirurgia , Próteses e Implantes
6.
Arch Orthop Trauma Surg ; 142(12): 4015-4023, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34837506

RESUMO

INTRODUCTION: Total hip replacement (THR) is considered one of the most effective medical procedures in treatment of osteoarthritis. Since its introduction, there has been a worldwide debate over proper implant selection in terms of size, bearing type and shape. Following study was designed to assess the importance of femoral head size in long-term follow-up. MATERIALS AND METHODS: A cohort of 30 patients with primary end stage osteoarthritis who underwent total hip replacement was analysed retrospectively. A homogenous group was chosen with no major differences in BMI. Patients' gait parameters were measured in a biomechanics laboratory using the 3D BTS Smart system. WOMAC and VAS questionnaires were used to assess patient reported outcome. RESULTS: The subgroup with larger implant head size had several outcomes significantly superior to the subgroup with standard head size and non-inferior to healthy hips. Following variables were measured during this study: time of support phase, time of swing phase, double support time, walking hip extension angle. CONCLUSIONS: Use of larger sized femoral heads during THR gives better results in terms of gait pattern. Since restoring the gait pattern is one of the aspects of rehabilitation and returning to daily activities it seems to be an important observation.


Assuntos
Artroplastia de Quadril , Osteoartrite , Humanos , Artroplastia de Quadril/métodos , Cabeça do Fêmur/cirurgia , Estudos Retrospectivos , Estudos de Coortes , Marcha , Osteoartrite/cirurgia , Articulação do Quadril/cirurgia
7.
Reumatologia ; 60(5): 340-346, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36381207

RESUMO

Introduction: Femoral neck fracture is one of the most common orthopaedic traumas affecting the elderly population. The standard treatment method is hip hemiarthroplasty and total hip arthroplasty. In hip hemiprostheses surgeons mainly have to reconstruct the femoral offset and limbs' length to obtain the correct gait biomechanics and a satisfactory surgical outcome.The aim of this study is to examine the radiological results of patients after hip hemiarthroplasty for femoral neck fracture and to evaluate the reconstruction of the femoral offset using standard neck angle stems. Material and methods: A consecutive series of 97 patients diagnosed with femoral neck fracture treated with a hip hemiprosthesis between 2017 and 2021 was identified and met the inclusion criteria. On preoperative images, the neck-shaft angle and the femoral offset on the healthy limb were measured. The femoral offset of the operated limb was measured on the postoperative X-rays. Results: There was a significant positive moderate correlation between neck-shaft angle and femoral offset change (r = 0.568, p < 0.0001). There was a statistically significant difference between femoral offset change and neck-shaft angle (24:52 vs. 14:7, p = 0.005). This means that in patients with coxa vara the change in femoral offset was more often < -5 mm. Less than half of operated patients had the femoral offset restored within a safe range (between -5 and 5 mm). Conclusions: Our study proved that it is sometimes hard to achieve femoral offset within a safe range while performing hip hemiarthroplasty in patients with coxa vara. The topic of using high offset stems in partial hip arthroplasty has not been thoroughly researched worldwide. However, taking into account the results of our study, during a hip hemiarthroplasty the usage of high offset stems for varus hips should be considered in order to improve the clinical outcome and improve patients' quality of life and functioning.

8.
Knee ; 48: 217-225, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38733872

RESUMO

BACKGROUND: Anterior knee pain (AKP) is one of the reasons for dissatisfaction after total knee replacement (TKR). It may result from patellofemoral joint dysfunction, caused by improper rotation of implant components. The aim of this study was to analyze patella positioning in patients after standard measured resection TKR and TKR with a use of a dynamic tensioner, and to assess the frequency of AKP, range of motion (ROM), and patient-reported outcome measures 6 weeks and 3 months postoperatively. METHODS: The study consisted of 127 patients who underwent TKR. Eighty-nine of them treated with use of the dynamic tensioner FUZION formed the study group; the remainder formed the control group. All participants received cemented PERSONA MC without patella resurfacing. All patients had a standard anteroposterior, lateral weight-bearing, long-leg view X-ray and computed tomography examination in 30° of knee flexion following the procedure. RESULTS: There were no significant differences between the study and the control groups regarding: posterior condylar axis (PCA)-patella angle, surgical transepicondylar axis (sTEA)-patella angle, PCA-sTEA angle, deviation from 90° in PCA-patella, sTEA-patella and PCA-sTEA angles. No significant difference was found in a ratio of obtaining PCA-patella angle deviation of more than 3°. Regarding clinical parameters, statistically and questionablly clinically significant difference in favor of the Study Group was found in Forgotten Joint Score 6 weeks and 3 months post-operativley and ROM 6 weeks post-operatively. However, such difference was not found by analyzing ROM 3 months post-operatively, AKP and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores. CONCLUSION: Compared with the standard 3° of femoral component external rotation, use of a dynamic tensioner does not allow for more accurate restoration of the patellar facet position with reference to the PCA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Patela , Amplitude de Movimento Articular , Humanos , Artroplastia do Joelho/métodos , Masculino , Feminino , Estudos de Casos e Controles , Amplitude de Movimento Articular/fisiologia , Idoso , Patela/cirurgia , Pessoa de Meia-Idade , Rotação , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/fisiopatologia , Fêmur/cirurgia , Desenho de Prótese , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Articulação do Joelho/diagnóstico por imagem
9.
Jpn J Radiol ; 41(1): 14-18, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36063354

RESUMO

Total hip replacement is one of the most widely performed surgeries. It is stated as the most efficient method of treating end-stage osteoarthritis of the hip joint. What is more, it significantly improves the quality of patients' lives, relieves them from pain and restores decreased range of motion, provided that is conducted properly. Aim of this article is to indicate which constituents of prosthetic placement can be easily measured on postoperative radiographs and point out how to interpret obtained results. Multiple mechanical factors, such as center of rotation, femoral offset, acetabular offset, acetabular inclination, acetabular anteversion and leg length discrepancy can be measured on postoperative radiographs. To provide a successful surgery and to acquire both radiological and clinical satisfying results, proper prosthetic placement is crucial. Malpositioning of each element, in varying degrees may lead to dislocation or reoperation.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Acetábulo , Radiografia , Estudos Retrospectivos
10.
Medicine (Baltimore) ; 101(42): e31107, 2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36281192

RESUMO

In every surgical subspecialty surgical site infection (SSI) or implant infections, although occur seldom, pose a threat to patients' health. Risk factors of such states is diabetes mellitus (DM), considered one of the most widespread health-related problems of the 21st century. Orthopedists perform big joint replacements that usually concern older adults and therefore often deal with patients suffering from comorbidities. DM is frequently one of them and can furthermore often remain underdiagnosed. The other risk for complication is a rapid beginning of the rehabilitation which starts on the day following the surgery. To eliminate the debilitating impact of DM and hypoglycemia on surgical patients, we aim to investigate the relationship between the glycemia values and the postoperative outcomes in certain periods of time in patients undergoing orthopedic surgeries. Participants meeting inclusion criteria will have inserted a glycemia measuring device (Dexcom G5, Inc., San Diego, CA) in the periods of time. First time it will take place 14 days prior to the surgery and right after the surgery for the second time for the period of another 14 days. All patients will undergo standard total knee arthroplasty or total hip arthroplasty procedures. Patients will be assessed preoperatively and 14 days, 1, 3, 6, 12, and 24 months postoperatively. The assessment of the joint condition will consist of: patient-reported outcomes (The Knee injury and Osteoarthritis Outcome Score, Harris Hip Score, the Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]); assessment of potential SSI and cardiovascular complications (the Finnish Diabetes Risk Score [FINDRISC], the Systematic Coronary Risk Evaluation [SCORE]) and the clinical examination. To investigate the influence of orthopedic surgery (anesthesia) on glycemia and the significance and safety of early patients mobilization after the big joints surgeries. To investigate changes of glycemia in patients with normal glycemia metabolism, potentially protecting them from hypoglycemia during hospital stay and increasing their awareness of potential development of DM in the future. Additionally, this study will correlate perioperative glycemic levels with risk of cardiovascular events in one year follow-up, and its influence on SSI and implant complications.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Hipoglicemia , Osteoartrite , Idoso , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Hipoglicemia/etiologia , Estudos Observacionais como Assunto , Osteoartrite/etiologia , Período Pós-Operatório , Infecção da Ferida Cirúrgica/etiologia , Resultado do Tratamento
11.
Arthroplast Today ; 14: 29-35, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35128014

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) is considered to be highly successful in treatment of end-stage osteoarthritis. There are multiple implant designs available on the market, and it is difficult to point which one is the best. The aim of this study was to compare the clinical and functional outcomes and gait pattern after TKA with the use of fixed-bearing medial pivot (K-Mod) vs multi-radius design (NexGen) implants and to compare them to norms for healthy patients with no osteoarthritis or arthroplasty procedure in anamnesis. METHODS: A group of 30 patients who received the medial pivot (MP) TKA and 33 patients who received the posterior-stabilized (PS) TKA between May and August of 2018 were included. All surgeries were performed in the level III academic hospital by a single surgeon. Every patient was asked to fulfill the The Western Ontario and McMaster Universities Arthritis Index (WOMAC) questionnaire preoperatively and 2 years postoperatively. Standard X-ray, biomechanical gait analysis using a motion capture system, and statistical analysis were performed at 2 years postoperatively. RESULTS: A total of 28 patients from either MP cohort (93%) or PS (85%) matched-control cohort completed the whole assessment at the final follow-up. There were statistically significant differences in a few gait parameters such as shorter mean step length both in operated and healthy limb, lower mean gait velocity, and lower mean walking cadence than the norm in both MP and PS groups. As to the WOMAC score, there was statistically significant improvement in both groups comparing preoperative and postoperative outcomes. Nevertheless, in the MP group, there was a significantly higher score, indicating worse outcomes, in the stiffness part of the WOMAC score than in the PS group. No significant differences were found between groups during radiological evaluation. CONCLUSIONS: There were satisfying and promising clinical, radiographic, and patient-reported outcomes in both MP and PS groups with very little difference in relation to norm values. However, both implants failed in fully restoring gait patterns similar to the healthy limb of the same patient.

12.
Arthroplast Today ; 12: 62-67, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34765714

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) is considered the most efficient treatment of end-stage osteoarthritis. There is an ongoing debate about proper implant designs and articulation types. One of the considered causes of unsatisfactory outcome and patients' dissatisfaction is femoral or tibial component overhanging, which can lead to chronic knee pain and restricted motion. The aim of this study is to compare radiological outcomes of TKA using an anatomic PERSONA Posterior-Stabilized (PS) knee design with its nonanatomic predecessor, the NexGen LPS. METHODS: A group of 39 patients who received the PERSONA PS system and 33 patients who received the NexGen LPS was included. PERSONA patients were matched to NexGen patients using a 0.1 propensity score threshold with priority given to exact matches. Anteroposterior, lateral, and long-leg radiographs were taken preoperatively and at 6 weeks postoperatively to perform radiological and statistical analysis. RESULTS: The PERSONA subgroup had statistically higher posterior condylar offset. There is no statistically significant difference in posterior condylar offset ratio. There were less cases of femoral notching, femoral overhang, and placing tibial baseplate in the medial overhang in the PERSONA PS subgroup than in the NexGen subgroup (each statistically significant). Occurrence of tibial underhang was not statistically significant. CONCLUSION: Radiological assessment in short-term follow-up showed excellent results for PERSONA knee design with better fit to native femur and tibia. In comparison to its predecessor, it also spares more bone tissue. As the aforementioned parameters are risk factors of lesser clinical outcomes, the PERSONA design gives high hopes for improvement of TKA satisfaction rate.

13.
J Clin Med ; 10(11)2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34064295

RESUMO

Total hip arthroplasty (THA) is currently considered the most effective treatment for end-stage hip osteoarthritis (OA). The surgery can be performed via a number of different approaches, including direct anterior (DAA; Smith-Petersen; Hueter), anterolateral (ALA; Watson-Jones), direct lateral (LA; Bauer), posterior (PA; Kocher-Langenbeck), and posterolateral (PLA). There is still a dispute over the optimal technique. The aim of this systematic review was to assess how different surgical approaches toward a THA influence the prosthesis elements' positioning. We conducted a literature search of Scopus, ScienceDirect, PubMed, Embase, and The Cochrane Library. We evaluated studies in terms of the first author's name, country, publication year, type of surgical approach being compared to the direct anterior approach, any significant differences at baseline, sample size, and radiographic analysis. A subanalysis of each approach in comparison to the DAA revealed differences in terms of all analyzed implant positioning radiographic parameters. There is still an insufficient number of randomized controlled studies that include radiological analyses comparing THRs (total hip replacements) performed using DAA with other approaches. Implant placement is a crucial step during a THR and surgeons must be aware that the approach they use might impact their judgment on angles and spaces inside the joint and thus alter the implant positioning.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA