Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(3): 440-450, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38282445

RESUMO

INTRODUCTION: During atrial fibrillation ablation (AFA), achievement of first pass isolation (FPI) reflects effective lesion formation and predicts long-term freedom from arrhythmia recurrence. We aim to determine the clinical and procedural predictors of pulmonary vein FPI. METHODS: We reviewed AFA procedures in a multicenter prospective registry of AFA (REAL-AF). A multivariate ordinal logistic regression, weighted by inverse proceduralist volume, was used to determine predictors of FPI. RESULTS: A total of 2671 patients were included with 1806 achieving FPI in both vein sides, 702 achieving FPI in one, and 163 having no FPI. Individually, age, left atrial (LA) scar, higher power usage (50 W), greater posterior contact force, ablation index >350 posteriorly, Vizigo™ sheath utilization, nonstandard ventilation, and high operator volume (>6 monthly cases) were all related to improved odds of FPI. Conversely sleep apnea, elevated body mass index (BMI), diabetes mellitus, LA enlargement, antiarrhythmic drug use, and center's higher fluoroscopy use were related to reduced odds of FPI. Multivariate analysis showed that BMI > 30 (OR 0.78 [0.64-0.96]) and LA volume (OR per mL increase = 1.00 [0.99-1.00]) predicted lower odds of achieving FPI, whereas significant left atrial scarring (>20%) was related to higher rates of FPI. Procedurally, the use of high power (50 W) (OR 1.32 [1.05-1.65]), increasing force posteriorly (OR 2.03 [1.19-3.46]), and nonstandard ventilation (OR 1.26 [1.00-1.59]) predicted higher FPI rates. At a site level, high procedural volume (OR 1.89 [1.48-2.41]) and low fluoroscopy centers (OR 0.72 [0.61-0.84]) had higher rates of FPI. CONCLUSION: FPI rates are affected by operator experience, patient comorbidities, and procedural strategies. These factors may be postulated to impact acute lesion formation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Estudos Prospectivos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Cicatriz , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Estudos Multicêntricos como Assunto
2.
Artigo em Inglês | MEDLINE | ID: mdl-38924224

RESUMO

INTRODUCTION: Training in clinical cardiac electrophysiology (CCEP) involves the development of catheter handling skills to safely deliver effective treatment. Objective data from analysis of ablation data for evaluating trainee of CCEP procedures has not previously been possible. Using the artificial intelligence cloud-based system (CARTONET), we assessed the impact of trainee progress through ablation procedural quality. METHODS: Lesion- and procedure-level data from all de novo atrial fibrillation (AF) and cavotricuspid isthmus (CTI) ablations involving first-year (Y1) or second-year (Y2) fellows across a full year of fellowship was curated within Cartonet. Lesions were automatically assigned to anatomic locations. RESULTS: Lesion characteristics, including contact force, catheter stability, impedance drop, ablation index value, and interlesion time/distance were similar over each training year. Anatomic location and supervising operator significantly affected catheter stability. The proportion of lesion sets delivered independently and of lesions delivered by the trainee increased steadily from the first quartile of Y1 to the last quartile of Y2. Trainee perception of difficult regions did not correspond to objective measures. CONCLUSION: Objective ablation data from Cartonet showed that the progression of trainees through CCEP training does not impact lesion-level measures of treatment efficacy (i.e., catheter stability, impedance drop). Data demonstrates increasing independence over a training fellowship. Analyses like these could be useful to inform individualized training programs and to track trainee's progress. It may also be a useful quality assurance tool for ensuring ongoing consistency of treatment delivered within training institutions.

3.
JAMA ; 331(7): 601-610, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38497695

RESUMO

Importance: Paroxysmal supraventricular tachycardia (PSVT), defined as tachyarrhythmias that originate from or conduct through the atria or atrioventricular node with abrupt onset, affects 168 to 332 per 100 000 individuals. Untreated PSVT is associated with adverse outcomes including high symptom burden and tachycardia-mediated cardiomyopathy. Observations: Approximately 50% of patients with PSVT are aged 45 to 64 years and 67.5% are female. Most common symptoms include palpitations (86%), chest discomfort (47%), and dyspnea (38%). Patients may rarely develop tachycardia-mediated cardiomyopathy (1%) due to PSVT. Diagnosis is made on electrocardiogram during an arrhythmic event or using ambulatory monitoring. First-line acute therapy for hemodynamically stable patients includes vagal maneuvers such as the modified Valsalva maneuver (43% effective) and intravenous adenosine (91% effective). Emergent cardioversion is recommended for patients who are hemodynamically unstable. Catheter ablation is safe, highly effective, and recommended as first-line therapy to prevent recurrence of PSVT. Meta-analysis of observational studies shows single catheter ablation procedure success rates of 94.3% to 98.5%. Evidence is limited for the effectiveness of long-term pharmacotherapy to prevent PSVT. Nonetheless, guidelines recommend therapies including calcium channel blockers, ß-blockers, and antiarrhythmic agents as management options. Conclusion and Relevance: Paroxysmal SVT affects both adult and pediatric populations and is generally a benign condition. Catheter ablation is the most effective therapy to prevent recurrent PSVT. Pharmacotherapy is an important component of acute and long-term management of PSVT.


Assuntos
Taquicardia Ventricular , Adulto , Criança , Feminino , Humanos , Masculino , Adenosina/administração & dosagem , Adenosina/uso terapêutico , Administração Intravenosa , Antiarrítmicos/administração & dosagem , Antiarrítmicos/uso terapêutico , Cardiomiopatias/etiologia , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Ablação por Cateter , Eletrocardiografia , Manobra de Valsalva , Cardioversão Elétrica
4.
Pacing Clin Electrophysiol ; 46(1): 3-10, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36301182

RESUMO

BACKGROUND: Intracardiac echocardiography (ICE) technology has been increasingly accepted as an integral part of atrial fibrillation (AF) ablation procedures. It is still unknown whether ICE can routinely replace transesophageal echocardiography (TEE) for routine thrombus screening in non-selective AF patients. OBJECTIVE: To assess whether ICE can routinely replace TEE in screening for left atrial (LA)/left atrial appendage (LAA) thrombus in general patients undergoing catheter ablation for AF. METHODS: A total of 2003 consecutive patients undergoing AF ablation were included. 1155 patients (ICE group) received intra-procedural ICE examination for LA/LAA thrombus screening, while 848 patients (TEE group) received pre-procedure TEE examination. The incidence of thrombus, peri-procedure complications, and hospital efficiency were assessed. RESULTS: The LA and LAA were adequately visualized in all patients. Five patients in the ICE group and 15 patients in the TEE group were found to have LAA thrombus. The incidence of major periprocedural thrombo-embolic events was comparable between two groups (0.2% vs. 0.1%, p = .76), none were due to undetected LA/LAA thrombus. Other major periprocedural complications occurred at similar rates in both groups, while post-procedure fever was less common in the ICE group (12.7% vs. 17.4%, p < .001). Procedure times and hospital length of stay were both shorter in the ICE group (142 min [87-197 min] vs. 150 min [95-205 min], and 3[2-4] day vs. 4[3-5] day, respectively, both p < .001). CONCLUSIONS: ICE can replace TEE for atrial thrombus screening in AF patients undergoing ablation without increased complications. An "ICE replacing TEE" workflow can also reduce the incidence of postoperative fever and improve hospital efficiency.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Cardiopatias , Trombose , Humanos , Ecocardiografia Transesofagiana/métodos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Cardiopatias/complicações , Trombose/complicações
5.
Pacing Clin Electrophysiol ; 46(9): 1035-1048, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37573146

RESUMO

Transcatheter radiofrequency ablation has been widely introduced for the treatment of tachyarrhythmias. The demand for catheter ablation continues to grow rapidly as the level of recommendation for catheter ablation. Traditional catheter ablation is performed under the guidance of X-rays. X-rays can help display the heart contour and catheter position, but the radiobiological effects caused by ionizing radiation and the occupational injuries worn caused by medical staff wearing heavy protective equipment cannot be ignored. Three-dimensional mapping system and intracardiac echocardiography can provide detailed anatomical and electrical information during cardiac electrophysiological study and ablation procedure, and can also greatly reduce or avoid the use of X-rays. In recent years, fluoroless catheter ablation technique has been well demonstrated for most arrhythmic diseases. Several centers have reported performing procedures in a purposefully designed fluoroless electrophysiology catheterization laboratory (EP Lab) without fixed digital subtraction angiography equipment. In view of the lack of relevant standardized configurations and operating procedures, this expert task force has written this consensus statement in combination with relevant research and experience from China and abroad, with the aim of providing guidance for hospitals (institutions) and physicians intending to build a fluoroless cardiac EP Lab, implement relevant technologies, promote the standardized construction of the fluoroless cardiac EP Lab.


Assuntos
Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Cirurgia Assistida por Computador , Humanos , Eletrofisiologia Cardíaca , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
6.
Pacing Clin Electrophysiol ; 45(10): 1216-1224, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35998211

RESUMO

Recurrence of atrial fibrillation (AF) after catheter ablation is common, with pulmonary vein (PV) reconnection considered the most likely cause. However, technologies such as contact force-sensing, irrigated catheters, and ablation index (AI)-guided ablation strategies have resulted in more durable PV isolation. As a result, it is difficult to predict which patients will develop AF recurrence despite durable PV isolation, with evolving non-PV atrial substrates thought to be a key contributor to late recurrences. Deciphering the complex mechanisms of AF recurrence beyond the cornerstone of PV isolation therefore remains challenging. Recently, there have been several important advances that may lead to better understanding and treatment of this challenging clinical entity: percutaneous epicardial access and mapping, late gadolinium enhancement magnetic resonance imaging (LGE-MRI), improvements in high-resolution electroanatomic mapping, and new ablation energy sources, specifically pulsed-field ablation. This review aims to synthesize the current literature in an effort to better understand arrhythmia mechanisms and treatment targets in patients with AF/Atrial tachycardia (AT) recurrence post-ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Gadolínio , Meios de Contraste , Recidiva , Resultado do Tratamento , Ablação por Cateter/métodos , Pericárdio/cirurgia
7.
Pacing Clin Electrophysiol ; 45(9): 1124-1131, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35621224

RESUMO

AIMS: To compare the cost of cardiac stereotactic body radioablation therapy (SBRT) versus catheter ablation for treating ventricular tachycardia (VT). BACKGROUND: Cardiac SBRT is a novel way of treating refractory VT that may be less costly than catheter ablation, owing to its noninvasive, outpatient nature. However, the true costs of either procedure are not well described, which could help inform a more appropriate reimbursement for cardiac SBRT than simply cross-indexing existing procedural rates. METHODS: Process maps were derived for the full patient care cycle of both procedures using time-driven activity-based costing. Step-by-step timestamps were collected prospectively from a 10-patient SBRT cohort and retrospectively from a 59-patient catheter ablation cohort. Individual costs were estimated by multiplying timestamps with capacity cost rates (CCRs) for personnel, space, equipment, consumable, and indirect resources. These were summed into total cost, which for cardiac SBRT was compared with current catheter ablation and single-fraction lung SBRT reimbursements, both potential reference rates for cardiac SBRT. RESULTS: The direct and total procedural costs of cardiac SBRT ($7549 and $10,621) were 49% and 54% less than those of VT ablation ($14,707 and $23,225). These costs were significantly different from current reimbursement for catheter ablation ($22,692) and lung SBRT ($6329). After including hospitalization expenses (≥$15,000), VT ablation costs at least $27,604 more to furnish than cardiac SBRT. CONCLUSIONS: Time-driven activity-based costing (TDABC) can be a helpful tool for assessing healthcare costs, including novel treatment approaches. In addition to its clinical benefits, cardiac SBRT may provide significant cost reduction opportunities for treatment of VT.


Assuntos
Ablação por Cateter , Radiocirurgia , Taquicardia Ventricular , Antiarrítmicos/uso terapêutico , Ablação por Cateter/métodos , Humanos , Radiocirurgia/métodos , Estudos Retrospectivos , Resultado do Tratamento
8.
J Cardiovasc Electrophysiol ; 32(11): 2901-2914, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34587335

RESUMO

INTRODUCTION: Despite advances in drug and catheter ablation therapy, long-term recurrence rates for ventricular tachycardia remain suboptimal. Cardiac stereotactic body radiotherapy (SBRT) is a novel treatment that has demonstrated reduction of arrhythmia episodes and favorable short-term safety profile in treatment-refractory patients. Nevertheless, the current clinical experience is early and limited. Recent studies have highlighted variable duration of treatment effect and substantial recurrence rates several months postradiation. Contributing to these differential outcomes are disparate approaches groups have taken in planning and delivering radiation, owing to both technical and knowledge gaps limiting optimization and standardization of cardiac SBRT. METHODS AND FINDINGS: In this report, we review the historical basis for cardiac SBRT and existing clinical data. We then elucidate the current technical gaps in cardiac radioablation, incorporating the current clinical experience, and summarize the ongoing and needed efforts to resolve them. CONCLUSION: Cardiac SBRT is an emerging therapy that holds promise for the treatment of ventricular tachycardia. Technical gaps remain, to be addressed by ongoing research and growing clincial experience.


Assuntos
Ablação por Cateter , Radiocirurgia , Taquicardia Ventricular , Arritmias Cardíacas , Ablação por Cateter/efeitos adversos , Coração , Humanos , Radiocirurgia/efeitos adversos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
11.
Pacing Clin Electrophysiol ; 43(7): 646-654, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32391576

RESUMO

Catheter ablation has emerged as an effective treatment for atrial fibrillation (AF). Atrial esophageal fistula (AEF) is a rare, but feared complication. With increasing utilization of ablation therapy for AF, the understanding of the relationship between AEF and ablation has been improved in recent years. Efforts to reduce the risk of AEF have focused on decreasing the risk of severe esophageal injury (EI) and the presumed subsequent progression from EI to AEF, including esophageal temperature monitoring, esophageal cooling systems, esophageal deviation devices, and decreasing and/or curtailing ablation energy delivery. Periprocedural assessment may help identify higher risk patients and detect early esophageal lesions. This review systematically summarizes and evaluates the current strategies and techniques utilized to reduce the risk of AEF in the clinical workflow for AF ablation. We expect that this review will help clinicians to better understand the principles, advantages, and disadvantages of these methods, and to find suitable strategies using current available tools.


Assuntos
Queimaduras/prevenção & controle , Ablação por Cateter , Fístula Esofágica/prevenção & controle , Esôfago/lesões , Átrios do Coração/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Fibrilação Atrial/cirurgia , Queimaduras/etiologia , Fístula Esofágica/etiologia , Humanos , Complicações Pós-Operatórias/etiologia
12.
Pacing Clin Electrophysiol ; 43(1): 12-18, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31736095

RESUMO

INTRODUCTION: Atrial fibrillation (AF) ablation requires access to the left atrium (LA) via transseptal puncture (TP). TP is traditionally performed with fluoroscopic guidance. Use of intracardiac echocardiography (ICE) and three-dimensional mapping allows for zero fluoroscopy TP. OBJECTIVE: To demonstrate safety and efficacy of zero fluoroscopy TP using multiple procedural approaches. METHODS: Patients undergoing AF ablation between January 2015 and November 2017 at five institutions were included. ICE and three-dimensional mapping were used for sheath positioning and TP. Variable technical approaches were used across centers including placement of J wire in the superior vena cava with ICE guidance followed by dragging down the transseptal sheath into the interatrial septum, or guiding the transseptal sheath directly to the interatrial septum by localizing the ablation catheter with three-dimensional mapping and replacing it with the transseptal needle once in position. In patients with pacemaker/implantable cardiac defibrillator leads, pre-/poststudy device interrogation was performed. RESULTS: A total of 747 TPs were performed (646 patients, age 63.1 ± 13.1, 67.5% male, LA volume index 34.5 ± 15.8 mL/m2 , ejection fraction 57.7 ± 10.9%) with 100% success. No punctures required fluoroscopy. Two pericardial effusions, two pericardial tamponades requiring pericardiocentesis, and one transient ischemic attack were observed during the overall ablation procedure, with a total complication rate of 0.7%. There were no other periprocedural complications related to TP, including intrathoracic bleeding, stroke, or death both immediately following TP and within 30 days of the procedure. In patients with intracardiac devices, no device-related complications were observed. CONCLUSION: TP can be safely and effectively performed without the need for fluoroscopy.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ecocardiografia/métodos , Átrios do Coração/cirurgia , Ultrassonografia de Intervenção/métodos , Mapeamento Epicárdico , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Punções
13.
J Cardiovasc Electrophysiol ; 29(6): 854-860, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29570900

RESUMO

INTRODUCTION: Atrial fibrillation (AF) ablation is increasingly common, but is associated with potential major complications. Technology, experience, and protocols have evolved significantly in recent times, and may have impacted procedural safety. We sought to compare AF ablation safety profiles, including complication rates and fluoroscopy times in a "modern" versus "historical" cohort. METHODS AND RESULTS: We evaluated consecutive patients undergoing AF ablation from a modern cohort (MC) from 2014 to 2015 and a historic cohort (HC) from 2009 to 2011 for complications. Major complications were categorized according to Heart Rhythm Society guidelines. We included 1,425 patients, 726 in the HC and 699 in the MC. The MC was older, had more OSA and less valvular AF. Fifty-two (3.5%) procedures suffered major complications across the cohorts, with significantly fewer in the MC (5.0% vs. 2.3%, P  =  0.007). The largest reductions were seen in vascular, hemorrhagic, ischemic stroke, and perforation/tamponade related complications. Periprocedural antiplatelets drugs (aHR 2.1 [95 CI 1.1-3.9], P  =  0.02) and force-sensing catheters (aHR 0.4 [95 CI 0.2-0.9], P  =  0.03) were independently related to major complication rates. Direct oral anticoagulants and uninterrupted anticoagulation were not associated with complications. There was a decrease in both fluoroscopy (-17.4 minutes [95 CI 19.2-15.6], P < 0.0001) and radiofrequency ablation times (-561 seconds [95CI -750 to -371], P < 0.0001). CONCLUSIONS: The safety profile of AF ablation has improved significantly in less than a decade.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/tendências , Complicações Pós-Operatórias/prevenção & controle , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Radiografia Intervencionista/tendências , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
Curr Cardiol Rep ; 19(9): 79, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28752279

RESUMO

PURPOSE OF REVIEW: Stereotactic radioablation is a commonly utilized technology to noninvasively treat solid tumors with precision and efficacy. Using a robotic arm mounted delivery system, multiple low-dose ionizing radiation beams are delivered from multiple angles, concentrating ablative energy at the target tissue. Recently, this technology has been evaluated for treatment of cardiac arrhythmias. This review will present the basic underlying principles, proof-of-principle studies, and clinical experience with stereotactic arrhythmia radioablation. RECENT FINDINGS: Most recently, stereotactic radioablation has been used to safely and effectively treat a limited number of patients with malignant arrhythmias, including ventricular tachycardia (VT) and atrial fibrillation (AF). Treatment protocols, outcomes, ongoing studies, and future directions will be discussed. Stereotactic radioablation is a well-established technology that has been shown to be a safe and effective therapy for patients with drug-refractory cardiac arrhythmias, including VT and AF. Further clinical evaluation to define safety and efficacy in larger populations of patients is needed.


Assuntos
Arritmias Cardíacas/radioterapia , Radiocirurgia , Fibrilação Atrial/radioterapia , Ablação por Cateter , Protocolos Clínicos , Humanos , Taquicardia Ventricular/radioterapia
16.
N Engl J Med ; 378(17): 1650, 2018 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-29697916
18.
19.
Heart Rhythm ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38960302

RESUMO

BACKGROUND: The association between hospital and physician procedure volume outcome has not been well evaluated for atrial fibrillation (AF) ablation in contemporary practice. OBJECTIVE: To determine the association between hospital and physician AF ablation volume and procedural success (isolation of all pulmonary veins) and major adverse events (MAE). METHODS: Procedures reported to the NCDR AFib Ablation Registry between July 2019 and June 2022 were included. Hospital and physician procedural volumes were annualized and stratified into quartiles (Q) to compare outcomes. Three level hierarchical (patient, hospital and physician) models were used to assess the procedural volume outcome relationship. RESULTS: A total of 70,296 first-time AF ablations at 186 U.S. hospitals were included. Overall, procedural success and MAE rate were 98.5 % and 1.0% respectively. With hospital volume (Q4) as a reference, the likelihood of procedural success was lower for Q1 (OR 0.44, 95%CI 0.29-0.68), Q2 (OR 0.50, 95%CI 0.33-0.75) and Q3 (OR 0.60, 95%CI 0.40-0.89); the results were similarly signifant for physician volume. With MAE for hospitals, there was an inverse procedural volume relationship for Q1 (OR 1.78, 95%CI 1.26-2.51) but not for Q2 (OR 1.06, 95%CI 0.77-1.46) or Q3 (OR 1.19, 95%CI 0.89-1.58) and similarly for physicians in Q1 and Q2, not in Q3. An adjusted MAE ≤ 1% was predicted by an annual volume of approximately 190 for hospitals and 60 for physicians. CONCLUSION: In this national cohort, hospital and physician AF ablation procedural volumes were directly related to acute procedural success and inversely related to rates of MAE.

20.
Heart Rhythm ; 21(3): 274-281, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38103707

RESUMO

BACKGROUND: Few methods have been reported to demonstrate real-time effects during vein of Marshall (VOM) ethanol infusion in persistent atrial fibrillation (PeAF). OBJECTIVE: This study was to evaluate the impact of left atrial (LA) monitoring using intracardiac echocardiography (ICE) during VOM ethanol infusion. METHODS: Seventy-four consecutive patients with PeAF who underwent VOM ethanol infusion followed by radiofrequency (RF) ablation were included. Patients with findings on ICE consistent with echogenic streaming in the LA and with increased myocardial local echogenicity along the VOM area were placed into one group (group A) and those without into the other group (group B). Outcomes between the 2 groups were compared. RESULTS: Forty-six patients (62%) were placed into group A. A new ethanol-induced low-voltage area in group A was larger than that in group B (8.5 cm2 [5.5-10.2 cm2] and 4.0 cm2 (2.4-6.3 cm2]; P < .001). The RF ablation time required to achieve MI block was reduced in group A patients (263.0 seconds [196.0-351.0 seconds] vs 417.0 seconds [315.0-709.5 seconds] in group B patients; P < .001). MI block was achieved in 46 patients (100%) via an endocardial approach in group A and 27 patients (96.4%) in group B (extra coronary sinus ablation in 4 patients). One patient developed clinically significant pericardial effusions and required pericardiocentesis in group B. CONCLUSION: Presence of increased myocardial local echogenicity at the ridge and consistent echogenic streaming in the LA detected by ICE-based imaging during VOM ethanol infusion suggests increased ablated tissue in that region and lower RF ablation time during ablation for PeAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Etanol , Vasos Coronários/diagnóstico por imagem , Átrios do Coração , Ablação por Cateter/métodos , Ecocardiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA