Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 210(3): 583-592, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29381379

RESUMO

OBJECTIVE: The purpose of this study is to compare dose-length product (DLP)-based calculation of effective dose (EDDLP) with Monte Carlo simulation organ-based calculation of effective dose (EDMCO) in 16- and 64-MDCT examinations, with the use of clinical examinations with automatic tube current modulation. MATERIALS AND METHODS: Dose data were obtained from 50 consecutive unenhanced head CT examinations, unenhanced chest CT examinations, and unenhanced and contrast-enhanced abdominopelvic CT examinations performed using 16- and 64-MDCT scanners, as well as from 50 pulmonary CT angiography (CTA) examinations performed using a 64-MDCT scanner and 31 pulmonary CTA examinations performed using a 16-MDCT scanner. The EDMCO and the mean patient effective diameter were calculated using commercially available software. The EDDLP was also calculated. Both the mean difference and percentage difference between EDDLP and EDMCO were calculated, and they were statistically compared according to patient sex, type of examination performed, and type of scanner used. RESULTS: EDDLP significantly underestimated the EDMCO by 0.3 mSv (19%) for men who underwent unenhanced head CT, 0.5 mSv (29%) for women who underwent unenhanced head CT, 0.9-1.4 mSv (9-13%) for men who underwent chest CT, and 4.7-4.8 mSv (39%) for women who underwent chest CT (p < 0.001). The EDDLP overestimated the EDMCO by 1.9-2.0 mSv (12-14%) for men who underwent abdominopelvic CT (p < 0.001), with no significant difference noted for women who underwent abdominopelvic CT's. No significant difference was noted in the percentage difference in ED between the 16- and 64-MDCT scanners (p ≥ 0.13). CONCLUSION: EDDLP underestimates EDMCO, the reference standard for dose calculation, by 19-39% in unenhanced head CT examinations and, among women, in chest CT examinations. EDDLP deviates from EDMCO by less than 15% for chest CT examinations of men and for abdominopelvic CT. These differences can be attributed to variable patient body habitus, automatic tube current modulation, and sex-neutral k-coefficients, and they should be considered when calculating ED, particularly in women.


Assuntos
Cabeça/diagnóstico por imagem , Doses de Radiação , Radiografia Abdominal/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Tamanho Corporal , Angiografia por Tomografia Computadorizada , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Método de Monte Carlo , Software , Tomógrafos Computadorizados
2.
Emerg Radiol ; 24(1): 13-20, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27568394

RESUMO

This study aimed to determine the incidence of non-traumatic acute aortic injury (AAI) extending from the chest into the abdomen or pelvis in emergency department (ED) patients with acute aortic syndrome (AAS), to estimate the effective dose of the abdominopelvic portion of these CT exams, and to compare the number needed to screen (NNS) with the collective population radiation dose of imaging those stations. All patients (n = 238) presenting to the ED with AAS between March 2014 and June 2015 who were imaged per CT AAI protocol (noncontrast and contrast-enhanced CT angiography of the chest, abdomen, and pelvis) were retrospectively identified in this IRB-approved HIPAA-compliant study. The Stanford classification for positive cases of AAI was further subclassified based on chest, abdominal, or pelvic involvement. The dose length product (DLP) of each exam was used to estimate the dose of the abdominal and pelvic stations and the collective effective dose for the population. There were five cases of aortic dissection (AD) and two of intramural hematoma (IMH), with an AAI incidence of 2.9/100. Three cases of AAI were confined to the chest. Two cases of AAI were confined to the chest and abdomen, and two cases involved the chest, abdomen, and pelvis. There was only one case of AAI involving the ascending aorta that extended into the abdomen or pelvis. The number needed to screen to identify (a) AAI extending from the chest into the abdomen or pelvis was 59.5 and (b) Stanford A AAI extending into the abdomen or pelvis was 238. The estimated mean effective dose for the abdominopelvic stations were unenhanced abdomen 2.3 mSv, unenhanced pelvis 3.3 mSv, abdominal CTA 2.5 mSv, and pelvic CTA 3.6 mSv. The collective effective doses to the abdomen and pelvis with unenhanced CT and CTA in 59.5 patients and 238 patients were 761.6 and 3046.4 mSv, respectively. While the estimated mean effective dose for imaging of the abdominopelvic stations are low, the collective effective dose should also be considered. It may be beneficial to modify or omit routine unenhanced CT and/or CTA of the abdomen/pelvis in this patient population in the absence of abdominal symptoms, and image the abdomen and pelvis in positive thoracic cases only.


Assuntos
Aorta Torácica/lesões , Doenças da Aorta/diagnóstico por imagem , Lesões do Sistema Vascular/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
3.
Sci Eng Ethics ; 22(2): 581-90, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26026968

RESUMO

This paper focuses on compost use in overpasses and underpasses for wild animals over roads and other similar linear structures. In this context, good quality of compost may result in faster and more resistant vegetation cover during the year. Inter alia, this can be interpreted also as reduction of damage and saving lives. There are millions of tones of plant residue produced every day worldwide. These represent prospective business for manufacturers of compost additives called "accelerators". The opinions of the sale representatives' with regards to other alternatives of biowaste utilization and their own products were reviewed. The robust analyzes of several "accelerated" composts revealed that the quality was generally low. Only two accelerated composts were somewhat similar in quality to the blank sample that was produced according to the traditional procedure. Overlaps between the interests of decision makers on future soil fertility were weighed against the preferences on short-term profit. Possible causes that allowed the boom of these underperforming products and the possible consequences are also discussed. Conclusions regarding the ethical concerns on how to run businesses with products whose profitability depends on weaknesses in the legal system and customer unawareness are to follow.


Assuntos
Agricultura , Comércio/ética , Ética nos Negócios , Reciclagem/métodos , Solo , Animais , Animais Selvagens , Biomassa , Ecossistema , Humanos , Plantas , Eliminação de Resíduos
4.
Radiographics ; 35(6): 1751-65, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26466183

RESUMO

As use of imaging in the evaluation of pregnant and lactating patients continues to increase, misperceptions of radiation and safety risks have proliferated, which has led to often unwarranted concerns among patients and clinicians. When radiologic examinations are appropriately used, the benefits derived from the information gained usually outweigh the risks. This review describes appropriateness and safety issues, estimated doses for imaging examinations that use iodizing radiation (ie, radiography, computed tomography, nuclear scintigraphy, and fluoroscopically guided interventional radiology), radiation risks to the mother and conceptus during various stages of pregnancy, and use of iodinated or gadolinium-based contrast agents and radiotracers in pregnant and lactating women. Maternal radiation risk must be weighed with the potential consequences of missing a life-threatening diagnosis such as pulmonary embolus. Fetal risks (ie, spontaneous abortion, teratogenesis, or carcinogenesis) vary with gestational age and imaging modality and should be considered in the context of the potential benefit of medically necessary diagnostic imaging. When feasible and medically indicated, modalities that do not use ionizing radiation (eg, magnetic resonance imaging) are preferred in pregnant and lactating patients. Radiologists should strive to minimize risks of radiation to the mother and fetus, counsel patients effectively, and promote a realistic understanding of risks related to imaging during pregnancy and lactation.


Assuntos
Diagnóstico por Imagem/métodos , Lactação , Segurança do Paciente , Complicações na Gravidez/diagnóstico , Gravidez , Mama/efeitos da radiação , Meios de Contraste/efeitos adversos , Diagnóstico por Imagem/efeitos adversos , Diagnóstico por Imagem/normas , Feminino , Feto/efeitos dos fármacos , Feto/efeitos da radiação , Humanos , Consentimento Livre e Esclarecido , Complicações na Gravidez/etiologia , Doses de Radiação , Exposição à Radiação/efeitos adversos , Compostos Radiofarmacêuticos/efeitos adversos
5.
Emerg Radiol ; 22(3): 315-27, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25417073

RESUMO

Computed tomography (CT) plays an important role in the evaluation of patients presenting to the emergency department with a suspected spontaneous gastrointestinal tract (GIT) perforation. Prospective identification of the site of perforation helps the emergency department physician plan the appropriate treatment in a potentially unstable patient. The purpose of this pictorial essay is to review the CT approach a radiologist should take when evaluating the patient with suspected perforation in the emergent setting. A series of patients presenting to the emergency department with surgically proven GIT perforations were retrospectively reviewed, and key images were obtained. For the purposes of this review, the anatomy of the abdominal cavity in relation to sites of GIT perforation will be discussed. CT findings of perforation will be described, including free intraperitoneal/extraperitoneal air, bowel wall discontinuity, and localized inflammatory changes. The use of a bone window setting to increase the free air conspicuity will be emphasized. The mimics of pneumoperitoneum will be demonstrated, including pneumothorax, pneumomediastinum, and venous air. Using a systematic approach, CT can precisely determine the presence and site of a gastrointestinal perforation in a majority of patients. This greatly assists the surgeon in planning the correct surgical approach.


Assuntos
Serviço Hospitalar de Emergência , Perfuração Intestinal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Diagnóstico Diferencial , Humanos
6.
Emerg Radiol ; 22(3): 329-35, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25421387

RESUMO

Computed tomography (CT) is an effective, readily available diagnostic imaging tool for evaluation of the emergency room (ER) patients with the clinical suspicion of perianal abscess and/or infected fistulous tract (anorectal sepsis). These patients usually present with perineal pain, fever, and leukocytosis. The diagnosis can be easy if the fistulous tract or abscess is visible on inspection of the perianal skin. If the tract or abscess is deep, then the clinical diagnosis can be difficult. Also, the presence of complex tracts or supralevator extension of the infection cannot be judged by external examination alone. Magnetic resonance imaging (MRI) is the best imaging test to accurately detect fistulous tracts, especially when they are complex (Omally et al. in AJR 199:W43-W53, 2012). However, in the acute setting in the ER, this imaging modality is not always immediately available. Endorectal ultrasound has also been used to identify perianal abscesses, but this modality requires hands-on expertise and can have difficulty localizing the offending fistulous tract. It may also require the use of a rectal probe, which the patient may not be able to tolerate. Contrast-enhanced CT is a very useful tool to diagnose anorectal sepsis; however, this has not received much attention in the recent literature (Yousem et al. in Radiology 167(2):331-334, 1988) aside from a paper describing CT imaging following fistulography (Liang et al. in Clin Imaging 37(6):1069-1076, 2013). An infected fistula is indicated by a fluid-/air-filled soft tissue tract surrounded by inflammation. A well-defined round to oval-shaped fluid/air collection is indicative of an abscess. The purpose of this article is to demonstrate the usefulness of contrast-enhanced CT in the diagnosis of acute anorectal sepsis in the ER setting. We will discuss the CT appearance of infected fistulous tracts and abscesses and how CT imaging can guide the ER physician in the clinical management of these patients.


Assuntos
Abscesso/diagnóstico por imagem , Fístula Retal/diagnóstico por imagem , Abscesso/microbiologia , Doença Aguda , Meios de Contraste , Diagnóstico Diferencial , Serviço Hospitalar de Emergência , Humanos , Fístula Retal/microbiologia , Tomografia Computadorizada por Raios X
7.
Sci Eng Ethics ; 21(1): 203-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24648115

RESUMO

Biochar is a soil-improving substrate made from phytomass pyrolysis. In Southeast Asia, its application decreases due to the long-term growth of biochar cost and thus caused further prolongation of the payback period. In the Euro-American civilization the biochar application is already almost forgotten once it has been much earlier recognized that the crop yields can be increased much faster with higher doses of nutrients and other agrochemicals. The payback period can be expected in decades. Such a long-time investment into soil fertility raises also many ethical questions. The final decision combines issues of social responsibility, risk and other financial indicators as well as personal preferences and more. The attitudes of Western and Central European decision makers in the agriculture business segment were analyzed on the basis of electronic questionnaire survey and a subsequent interview through their local unions. According to the data, most of them did not know about the possibilities of a more environmentally friendly approach to soil enhancement based on the addition of a fertilizer in the form of biochar. Among others, the collected data also shows that the decision makers from Western Europe have a much different ethical approach to the land and financial indicators than the Central Europeans.


Assuntos
Agricultura/economia , Carvão Vegetal/economia , Mudança Climática/economia , Comércio , Custos e Análise de Custo , Fertilizantes/economia , Solo/química , Meio Ambiente , Europa (Continente) , Humanos , Inquéritos e Questionários
8.
Int J Cardiovasc Imaging ; 40(6): 1201-1209, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38630211

RESUMO

This study assesses the agreement of Artificial Intelligence-Quantitative Computed Tomography (AI-QCT) with qualitative approaches to atherosclerotic disease burden codified in the multisociety 2022 CAD-RADS 2.0 Expert Consensus. 105 patients who underwent cardiac computed tomography angiography (CCTA) for chest pain were evaluated by a blinded core laboratory through FDA-cleared software (Cleerly, Denver, CO) that performs AI-QCT through artificial intelligence, analyzing factors such as % stenosis, plaque volume, and plaque composition. AI-QCT plaque volume was then staged by recently validated prognostic thresholds, and compared with CAD-RADS 2.0 clinical methods of plaque evaluation (segment involvement score (SIS), coronary artery calcium score (CACS), visual assessment, and CAD-RADS percent (%) stenosis) by expert consensus blinded to the AI-QCT core lab reads. Average age of subjects were 59 ± 11 years; 44% women, with 50% of patients at CAD-RADS 1-2 and 21% at CAD-RADS 3 and above by expert consensus. AI-QCT quantitative plaque burden staging had excellent agreement of 93% (k = 0.87 95% CI: 0.79-0.96) with SIS. There was moderate agreement between AI-QCT quantitative plaque volume and categories of visual assessment (64.4%; k = 0.488 [0.38-0.60]), and CACS (66.3%; k = 0.488 [0.36-0.61]). Agreement between AI-QCT plaque volume stage and CAD-RADS % stenosis category was also moderate. There was discordance at small plaque volumes. With ongoing validation, these results demonstrate a potential for AI-QCT as a rapid, reproducible approach to quantify total plaque burden.


Assuntos
Inteligência Artificial , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Estenose Coronária , Placa Aterosclerótica , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Calcificação Vascular , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Idoso , Reprodutibilidade dos Testes , Calcificação Vascular/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada Multidetectores , Variações Dependentes do Observador
9.
Front Cardiovasc Med ; 9: 839400, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35387447

RESUMO

Coronary artery disease is a leading cause of death worldwide. There has been a myriad of advancements in the field of cardiovascular imaging to aid in diagnosis, treatment, and prevention of coronary artery disease. The application of artificial intelligence in medicine, particularly in cardiovascular medicine has erupted in the past decade. This article serves to highlight the highest yield articles within cardiovascular imaging with an emphasis on coronary CT angiography methods for % stenosis evaluation and atherosclerosis quantification for the general cardiologist. The paper finally discusses the evolving paradigm of implementation of artificial intelligence in real world practice.

10.
J Cardiovasc Comput Tomogr ; 15(6): 470-476, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34127407

RESUMO

BACKGROUND: Atherosclerosis evaluation by coronary computed tomography angiography (CCTA) is promising for coronary artery disease (CAD) risk stratification, but time consuming and requires high expertise. Artificial Intelligence (AI) applied to CCTA for comprehensive CAD assessment may overcome these limitations. We hypothesized AI aided analysis allows for rapid, accurate evaluation of vessel morphology and stenosis. METHODS: This was a multi-site study of 232 patients undergoing CCTA. Studies were analyzed by FDA-cleared software service that performs AI-driven coronary artery segmentation and labeling, lumen and vessel wall determination, plaque quantification and characterization with comparison to ground truth of consensus by three L3 readers. CCTAs were analyzed for: % maximal diameter stenosis, plaque volume and composition, presence of high-risk plaque and Coronary Artery Disease Reporting & Data System (CAD-RADS) category. RESULTS: AI performance was excellent for accuracy, sensitivity, specificity, positive predictive value and negative predictive value as follows: >70% stenosis: 99.7%, 90.9%, 99.8%, 93.3%, 99.9%, respectively; >50% stenosis: 94.8%, 80.0%, 97.0, 80.0%, 97.0%, respectively. Bland-Altman plots depict agreement between expert reader and AI determined maximal diameter stenosis for per-vessel (mean difference -0.8%; 95% CI 13.8% to -15.3%) and per-patient (mean difference -2.3%; 95% CI 15.8% to -20.4%). L3 and AI agreed within one CAD-RADS category in 228/232 (98.3%) exams per-patient and 923/924 (99.9%) vessels on a per-vessel basis. There was a wide range of atherosclerosis in the coronary artery territories assessed by AI when stratified by CAD-RADS distribution. CONCLUSIONS: AI-aided approach to CCTA interpretation determines coronary stenosis and CAD-RADS category in close agreement with consensus of L3 expert readers. There was a wide range of atherosclerosis identified through AI.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Estenose Coronária , Inteligência Artificial , Aterosclerose/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Constrição Patológica , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Humanos , Inteligência , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X
11.
Abdom Radiol (NY) ; 45(4): 1018-1035, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32152644

RESUMO

The use of 18F-fluorodeoxyglucose (FDG) positron emission tomography combined with computed tomography (PET/CT) is well established in the evaluation of alimentary tract malignancies. This review of the literature and demonstration of correlative images focuses on the current role of PET/CT in the diagnosis (including pathologic/clinical staging) and post-therapy follow-up of esophageal, gastric, and colorectal cancers. PET/CT provides utility in the management of esophageal cancer, including detection of distant disease prior to resection. In gastric cancer, PET/CT is useful in detecting solid organ metastases and in characterizing responders vs. non-responders after neoadjuvant chemotherapy, the latter of which have poorer overall survival. In patients with GIST tumors, PET/CT also determines response to imatinib therapy with greater expedience as compared to CECT. For colorectal cancer, PET/CT has proven helpful in detecting hepatic and other distant metastases, treatment response, and differentiating post-radiation changes from tumor recurrence. Our review also highlights several pitfalls in PET/CT interpretation of alimentary tract lesions.


Assuntos
Neoplasias do Sistema Digestório/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias do Sistema Digestório/patologia , Neoplasias do Sistema Digestório/terapia , Fluordesoxiglucose F18 , Humanos , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos
12.
Abdom Radiol (NY) ; 43(9): 2474-2486, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29520427

RESUMO

All women, during their lifetime, are at risk of developing some form of gynecologic malignancy. The role of FDG-PET/CT has become more established in the management of gynecologic malignancies in the last decade. In this article, we will review the role of FDG-PET/CT in endometrial, cervical, ovarian, and vaginal cancer, by highlighting its strengths and limitations. While the role in initial or pre-operative staging for FDG-PET/CT is controversial, it allows noninvasive detection of equivocal or distant metastases, may alter stage and prognosis, and can guide or help eliminate unnecessary interventions that may not be beneficial. FDG-PET/CT is a useful adjunct to traditional staging with MR and CT.


Assuntos
Doenças dos Genitais Femininos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Feminino , Fluordesoxiglucose F18 , Doenças dos Genitais Femininos/patologia , Humanos , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos
13.
Abdom Radiol (NY) ; 42(4): 1199-1209, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27873041

RESUMO

PURPOSE: The purpose of the study was to present a pictorial review of the long-term sequelae of acute pancreatitis on CT imaging as these findings can cause diagnostic confusion in the absence of a proper clinical history and/or prior CT imaging. METHODS: We retrospectively identified 81 patients who had an episode of acute pancreatitis with diagnostic findings on CT and also underwent one or more follow-up CT scans at least 1 month beyond the acute episode. The residual findings on all follow-up CT scans were tabulated, including the time interval since the initial bout of acute pancreatitis. RESULT: Residual inflammatory changes were present in 19.8% of cases, with a median time period lasting 86 days since the initial episode of acute pancreatitis. Residual fluid collections were seen in 27.2% and persisted for a median of 132 days. Three patients had residual solid-appearing inflammatory masses, which could be mistaken for neoplasms. Other long-term sequelae were also tabulated, including pancreatic ductal dilatation, pancreatic atrophy, new or increased pancreatic calcifications, biliary tract dilatation, central portal venous occlusion, and pseudoaneurysm formation. These residual findings and long-term complications are presented as a pictorial essay. CONCLUSION: Recognizing the spectrum of residual findings of acute pancreatitis, some of which can be long term, is important in the correct interpretation of a pancreatic CT. These findings can mimic acute pancreatitis or a pancreatic/peripancreatic neoplasm and often cause diagnostic confusion, especially in the absence of prior CT imaging.


Assuntos
Pancreatite/diagnóstico por imagem , Pancreatite/patologia , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Idoso , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
AJR Am J Roentgenol ; 187(4): W392-5, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16985110

RESUMO

OBJECTIVE: Duodenal diverticulitis is a rare complication of duodenal diverticulosis. It is often clinically misdiagnosed because it has no pathognomonic signs or symptoms and its CT findings may mimic other intraabdominal processes. We describe two patients with duodenal diverticulitis who presented with abdominal pain, nausea, and leukocytosis. At the time of initial presentation, only one of the two patients was diagnosed correctly. In the first case, which was initially misdiagnosed as acute pancreatitis, the correct diagnosis was evident only after the disease process had become more quiescent and a follow-up CT scan using orally and i.v.-administered contrast agents was performed. In the second case, the coronal reformatted images confirmed the diagnosis suggested by the axial images. CONCLUSION: Duodenal diverticulitis can be a difficult CT diagnosis to make; however, maintaining it in the differential diagnosis of duodenal and pancreatic inflammatory processes and masses as well as defining the anatomy with nonaxial imaging including coronal images may be helpful in confirming the diagnosis.


Assuntos
Diverticulite/diagnóstico por imagem , Duodenopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Feminino , Humanos , Pessoa de Meia-Idade
15.
Med Phys ; 31(9): 2423-42, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15487722

RESUMO

The ACR CT accreditation program, begun in 2002, requires the submission of approximately 20 images, several completed data sheets and printouts of three Excel worksheets. The procedure manual is very detailed, yet participants unfamiliar with the program or having minimal CT experience have needed to redo aspects of their submission, or in some cases do not receive accreditation, due to mistakes made by the physicist. This review of the phantom portion of the ACR CT accreditation program supplements the ACR provided instructions with additional photos of phantom setup, region-of-interest (ROI), and image placement on the film sheets, and examples of completed portions of actual (but anonymous) submissions. Common mistakes, as well as uncommon but interesting images, are shown and explanations are given as to what could have been done to avoid the problem. Additionally, a review of CT dose measurement techniques and calculations will enable the physicist to better assist sites where typical exam doses are above the ACR reference values.


Assuntos
Acreditação/normas , Física Médica/instrumentação , Física Médica/normas , Imagens de Fantasmas/normas , Radiometria/instrumentação , Radiometria/normas , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas , Artefatos , Física Médica/educação , Física Médica/métodos , Guias de Prática Clínica como Assunto , Competência Profissional/normas , Radiometria/métodos , Padrões de Referência , Tomografia Computadorizada por Raios X/métodos
16.
J Am Coll Radiol ; 11(8): 771-6, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25087988

RESUMO

Many previous studies have shown that nonradiologist physicians who can refer advanced MRI and CT examinations to themselves or within their practices use these modalities at a much higher rate than those who refer their examinations to unaffiliated radiology facilities. This led Maryland to pass a unique self-referral law in 1993 to directly address self-referred advanced imaging. The authors discuss the politics and economics of self-referral and provide a comprehensive review of the creation, progression, and impact of this landmark law.


Assuntos
Autorreferência Médica/legislação & jurisprudência , Radiologia/legislação & jurisprudência , História do Século XX , História do Século XXI , Humanos , Maryland , Autorreferência Médica/ética , Radiologia/ética , Radiologia/história
17.
J Am Coll Radiol ; 8(4): 275-80, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21458767

RESUMO

PURPOSE: The aim of this study was to determine, for 3 basic clinical examinations, whether blinded, experienced CT radiologists participating in the ACR's CT Accreditation Program could use scan parameters such as tube current-time product (mAs), tube voltage (kVp), and pitch to predict scanner output settings, expressed as weighted CT dose index (CTDIw) and volume CT dose index (CTDIvol), exceeding CTDIw diagnostic reference levels (DRLs) set by the ACR in 2002 and CTDIvol DRLs adopted by the ACR in 2008. METHODS: CT sites with 829 scanners submitted examinations to the ACR between 2002 and 2004, yielding 518 eligible examinations for analysis (138 adult head CT scans, 333 adult abdominal CT scans, and 47 pediatric abdominal CT scans). The sites' measured CTDIw values for each type of examination were compared with the ACR's CTDIw DRLs in effect from 2002 to 2004 and compared with comments regarding excessively high mAs or kVp made by radiologist clinical reviewers to determine if excessively high-dose index measurements could be predicted. The same analysis was repeated using CTDIvol DRLs adopted by the ACR in 2008 and compared with excessively high mAs or kVp and excessively low-pitch comments. RESULTS: Excessively high mAs or kVp comments yielded sensitivity of only 21.2% in predicting examinations above the CTDIw DRLs, with specificity of 87.6%. Using the 2008 CTDIvol DRLs, the corresponding sensitivity was 13.1% and specificity was 86.2%. Significance was not achieved for use of clinical parameters in predicting either the CTDIw or CTDIvol. CONCLUSION: Experienced CT radiologists cannot reliably use scan parameters to predict examinations that exceed CTDIw or CTDIvol DRLs.


Assuntos
Acreditação , Competência Clínica , Avaliação Educacional/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/normas , Bases de Dados Factuais , Humanos , Valor Preditivo dos Testes , Sociedades Médicas , Estados Unidos
18.
J Cardiovasc Comput Tomogr ; 5(1): 44-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21130724

RESUMO

BACKGROUND: Computed tomography coronary angiography (CTCA) provides an accurate noninvasive alternative to the invasive assessment of coronary artery disease. However, a specific limitation of CTCA is inability to assess hemodynamic data. OBJECTIVE: We hypothesized that CTCA-derived measurements of contrast within the superior vena cava (SVC) and inferior vena cava (IVC) would correlate to echocardiographic estimations of right atrial and right ventricular pressures. METHODS: Medical records of all patients who underwent both echocardiography and CTCA in our center were reviewed (n = 32). Standard CTCA was performed with a 64-detector CT using test-bolus method for image acquisition timing and iso-osmolar contrast injection through upper extremity vein. The length of the column of contrast reflux into the inferior vena cava (IVC) was correlated to echocardiographically determine tricuspid regurgitation jet velocity (TRV). SVC area change with contrast injection at the level of the bifurcation of the pulmonary artery was also correlated with IVC sniff response by echocardiogram. RESULTS: The reflux column length was interpretable in 27 of 32 patients with a mean length of 10.1 ± 1.1 mm, and a significant bivariate correlation was observed between reflux column length and the tricuspid regurgitant jet velocity (r = 0.84; P < .0001). Mean SVC distensibility ratio was 0.63 ± 0.03; mean IVC sniff response ratio was 0.53 ± 0.03. SVC distensibility correlated to IVC sniff response with a Pearson r of 0.57 (P = .04). CONCLUSION: Quantification of IVC and SVC contrast characteristics during CTCA provides a feasible and potentially accurate method of estimating right atrial and ventricular pressure.


Assuntos
Determinação da Pressão Arterial/métodos , Angiografia Coronária/métodos , Átrios do Coração/fisiopatologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Algoritmos , Função do Átrio Direito , Pressão Sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
J Am Coll Radiol ; 8(11): 795-803, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22051465

RESUMO

PURPOSE: The aim of this study was to assess the distribution of CT dose index (CTDI) values reported by sites undergoing ACR CT accreditation between 2002 and 2004. METHODS: Weighted CTDI (CTDI(w)) values were measured and reported by sites applying for ACR CT accreditation, and the percentage of scanners with values above the 2002 ACR diagnostic reference levels (DRLs) was determined. Acquisition parameters for a site's adult head, adult abdominal, and pediatric abdominal examinations were used to calculate volume CTDI (CTDI(vol)), and the average and standard deviation were calculated by year. Histogram analysis was performed to determine 75th and 90th percentiles of CTDI(vol). RESULTS: Between September 2002 and December 2004, 829 scanners underwent the accreditation process. Volume CTDI values (average ± SD) for 2002, 2003, 2004, and 2002 to 2004, respectively, were 66.7 ± 23.5, 58.5 ± 17.5, 55.8 ± 15.7, and 59.1 ± 18.6 mGy for adult head examinations; 18.7 ± 8.0, 19.2 ± 8.6, 17.0 ± 7.6, and 18.4 ± 8.3 for adult abdominal examinations; and 17.2 ± 9.7, 15.9 ± 8.6, 14.0 ± 7.0, and 15.5 ± 8.4 for pediatric abdominal examinations. For 2004 data, 23.8%, 2.3%, and 6.9% of sites reported doses above the 2002 CTDI(w) reference levels, compared with 49.6%, 4.7%, and 15% for 2002 data for adult head, adult abdominal, and pediatric abdominal examinations, respectively. Seventy-fifth percentiles of CTDI(vol) were 76.8 mGy (adult head, 2002 only), 22.2 mGy (adult abdominal), and 20.0 mGy (pediatric abdominal). CONCLUSIONS: From 2002 to 2004, average CTDI(vol) values decreased by 10.9, 1.7, and 3.2 mGy for adult head, adult abdominal, and pediatric abdominal examinations. Effective January 1, 2008, the ACR program implemented United States-specific diagnostic reference levels of 75, 25, and 20 mGy, respectively, for the CTDI(vol) of routine adult head, adult abdominal, and pediatric abdominal CT scans.


Assuntos
Acreditação/organização & administração , Doses de Radiação , Proteção Radiológica/normas , Radiometria/normas , Abdome/efeitos da radiação , Adulto , Fatores Etários , Criança , Pré-Escolar , Estudos de Avaliação como Assunto , Feminino , Cabeça/diagnóstico por imagem , Humanos , Masculino , Avaliação de Programas e Projetos de Saúde , Radiografia Abdominal/normas , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Gestão da Segurança , Sociedades Médicas/normas , Estados Unidos
20.
Acad Radiol ; 17(1): 120-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19969255

RESUMO

The Residency Review Committee of the American Council of Graduate Medical Education has designated abdominal radiology as one of the subspecialty areas required for radiology residency training. Because it spans both gastrointestinal and genitourinary organ systems and multiple modalities, a graduated, integrated abdominal radiology curriculum, which is based on the General Competencies, was developed.


Assuntos
Currículo , Internato e Residência/organização & administração , Radiografia Abdominal , Radiologia/educação , District of Columbia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA