Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 52(2): 369-379, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31452303

RESUMO

Renal perfusion can be quantitatively assessed by multiple magnetic resonance imaging (MRI) methods, including dynamic contrast enhanced (DCE), arterial spin labeling (ASL), and diffusion-weighted imaging with intravoxel incoherent motion (IVIM) analysis. In this review we summarize the advances in the field of renal-perfusion MRI over the past 5 years. The review starts with a brief introduction of relevant MRI methods, followed by a discussion of recent technical developments. In the main section of the review, we examine the clinical and preclinical applications for three disease populations: chronic kidney disease, renal transplant, and renal tumors. The DCE method has been routinely used for assessing renal tumors but not other renal diseases. As a noncontrast alternative, ASL was extensively explored in both preclinical and clinical applications and showed much promise. Protocol standardization for the methods is desperately needed, and then large-scale clinical trials for the methods can be initiated prior to their broad clinical use. Level of Evidence: 5 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019. J. Magn. Reson. Imaging 2020;52:369-379.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Meios de Contraste , Humanos , Movimento (Física) , Perfusão , Imagem de Perfusão , Marcadores de Spin
2.
MAGMA ; 33(1): 199-215, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31768797

RESUMO

Harmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplementary material, as the starting point in developing the survey questionnaires for seeking consensus. Survey data were collected via the Delphi consensus process from 24 researchers on renal BOLD MRI exam preparation, data acquisition, data analysis, and interpretation. Consensus was defined as ≥ 75% unanimity in response. Among 31 survey questions, 14 achieved consensus resolution, 12 showed clear respondent preference (65-74% agreement), and 5 showed equal (50/50%) split in opinion among respondents. Recommendations for subject preparation, data acquisition, processing and reporting are given based on the survey results and review of the literature. These technical recommendations are aimed towards increased inter-site harmonization, a first step towards standardization of renal BOLD MRI protocols across sites. We expect this to be an iterative process updated dynamically based on progress in the field.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Animais , Biomarcadores/metabolismo , Consenso , Técnica Delphi , Humanos , Rim/metabolismo , Imageamento por Ressonância Magnética/normas , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Inquéritos e Questionários , Pesquisa Translacional Biomédica/tendências
3.
MAGMA ; 33(1): 141-161, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31833014

RESUMO

OBJECTIVES: This study aimed at developing technical recommendations for the acquisition, processing and analysis of renal ASL data in the human kidney at 1.5 T and 3 T field strengths that can promote standardization of renal perfusion measurements and facilitate the comparability of results across scanners and in multi-centre clinical studies. METHODS: An international panel of 23 renal ASL experts followed a modified Delphi process, including on-line surveys and two in-person meetings, to formulate a series of consensus statements regarding patient preparation, hardware, acquisition protocol, analysis steps and data reporting. RESULTS: Fifty-nine statements achieved consensus, while agreement could not be reached on two statements related to patient preparation. As a default protocol, the panel recommends pseudo-continuous (PCASL) or flow-sensitive alternating inversion recovery (FAIR) labelling with a single-slice spin-echo EPI readout with background suppression and a simple but robust quantification model. DISCUSSION: This approach is considered robust and reproducible and can provide renal perfusion images of adequate quality and SNR for most applications. If extended kidney coverage is desirable, a 2D multislice readout is recommended. These recommendations are based on current available evidence and expert opinion. Nonetheless they are expected to be updated as more data become available, since the renal ASL literature is rapidly expanding.


Assuntos
Circulação Cerebrovascular , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Marcadores de Spin , Pesquisa Translacional Biomédica/tendências , Algoritmos , Consenso , Técnica Delphi , Imagem Ecoplanar , Humanos , Processamento de Imagem Assistida por Computador/métodos , Rim/irrigação sanguínea , Transplante de Rim , Angiografia por Ressonância Magnética , Estudos Multicêntricos como Assunto , Perfusão , Artéria Renal/diagnóstico por imagem , Reprodutibilidade dos Testes , Razão Sinal-Ruído
4.
Am J Physiol Heart Circ Physiol ; 316(1): H201-H211, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30388024

RESUMO

Peripheral artery disease (PAD) in the lower extremities often leads to intermittent claudication. In the present study, we proposed a low-dose DCE MRI protocol for quantifying calf muscle perfusion stimulated with plantar flexion and multiple new metrics for interpreting perfusion maps, including the ratio of gastrocnemius over soleus perfusion (G/S; for assessing the vascular redistribution between the two muscles) and muscle perfusion normalized by whole body perfusion (for quantifying the muscle's active hyperemia). Twenty-eight human subjects participated in this Institutional Review Board-approved study, with 10 healthy subjects ( group A) for assessing interday reproducibility and 8 healthy subjects ( group B) for exploring the relationship between plantar-flexion load and induced muscle perfusion. In a pilot group of five elderly healthy subjects and five patients with PAD ( group C), we proposed a protocol that measured perfusion for a low-intensity exercise and for an exhaustion exercise in a single MRI session. In group A, perfusion estimates for calf muscles were highly reproducible, with correlation coefficients of 0.90-0.93. In group B, gastrocnemius perfusion increased linearly with the exercise workload ( P < 0.05). With the low-intensity exercise, patients with PAD in group C showed substantially lower gastrocnemius perfusion compared with elderly healthy subjects [43.4 (SD 23.5) vs. 106.7 (SD 73.2) ml·min-1·100 g-1]. With exhaustion exercise, G/S [1.0 (SD 0.4)] for patients with PAD was lower than both its low-intensity level [1.9 (SD 1.3)] and the level in elderly healthy subjects [2.7 (SD 2.1)]. In conclusion, the proposed MRI protocol and the new metrics are feasible for quantifying exercise-induced muscle hyperemia, a promising functional test of PAD. NEW & NOTEWORTHY To quantitatively map exercise-induced hyperemia in calf muscles, we proposed a high-resolution MRI method shown to be highly reproducible and sensitive to exercise load. With the use of low contrast, it is feasible to measure calf muscle hyperemia for both low-intensity and exhaustion exercises in a single MRI session. The newly proposed metrics for interpreting perfusion maps are promising for quantifying intermuscle vascular redistribution or a muscle's active hyperemia.


Assuntos
Exercício Físico , Hiperemia/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/irrigação sanguínea , Doença Arterial Periférica/diagnóstico por imagem , Adulto , Tornozelo/irrigação sanguínea , Tornozelo/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem
5.
Am J Physiol Renal Physiol ; 314(5): F747-F752, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29357425

RESUMO

Glomerular fibrosis occurs in the early stages of multiple renal diseases, including hypertensive and diabetic nephropathy. Conventional assessment of glomerular fibrosis relies on kidney biopsy, which is invasive and does not reflect physiological aspects such as blood perfusion. In this study, we sought to assess potential changes of cortical perfusion and microstructure at different degrees of glomerular fibrosis using magnetic resonance imaging (MRI). A rat model of glomerular fibrosis was induced by injecting anti-Thy-1 monoclonal antibody OX-7 to promote mesangial extracellular matrix proliferation. For six rats on day 5 and five rats on day 12 after the induction, we measured renal cortical perfusion and spin-spin relaxation time (T2) in a 3-Tesla MRI scanner. T2 reflects tissue microstructural changes. Glomerular fibrosis severity was evaluated by histological analysis and proteinuria. Four rats without fibrosis were included as controls. In the control rats, the periodic acid-Schiff (PAS)-positive area was 22 ± 1% of total glomerular tuft, which increased significantly to 56 ± 12% and 45 ± 10% in the day 5 and day 12 fibrotic groups, respectively ( P < 0.01). For the three groups (control, day 5, and day 12 after OX-7 injection), cortical perfusion was 7.27 ± 2.54, 3.78 ± 2.17, and 3.32 ± 2.62 ml·min-1·g-1, respectively, decreasing with fibrosis severity ( P < 0.01), and cortical T2 was 75.2 ± 4.6, 84.1 ± 3.0, and 87.9 ± 5.6 ms, respectively ( P < 0.01). In conclusion, extracellular matrix proliferation in glomerular mesangial cells severely diminished blood flow through the glomeruli and also altered cortical microstructure to increase cortical T2. The MRI-measured parameters are proven to be sensitive markers for characterizing glomerular fibrosis.


Assuntos
Mesângio Glomerular/irrigação sanguínea , Mesângio Glomerular/diagnóstico por imagem , Glomerulonefrite/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem de Perfusão/métodos , Circulação Renal , Albuminúria/diagnóstico por imagem , Albuminúria/patologia , Animais , Velocidade do Fluxo Sanguíneo , Proliferação de Células , Modelos Animais de Doenças , Progressão da Doença , Estudos de Viabilidade , Fibrose , Mesângio Glomerular/patologia , Glomerulonefrite/patologia , Glomerulonefrite/fisiopatologia , Interpretação de Imagem Assistida por Computador , Masculino , Valor Preditivo dos Testes , Ratos Sprague-Dawley , Índice de Gravidade de Doença , Fatores de Tempo
6.
J Am Soc Nephrol ; 28(9): 2564-2570, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28784699

RESUMO

Magnetic resonance imaging (MRI) has been used for many years for anatomic evaluation of the kidney. Recently developed methods attempt to go beyond anatomy to give information about the health and function of the kidneys. Several methods, including diffusion-weighted MRI, renal blood oxygen level-dependent MRI, renal MR elastography, and renal susceptibility imaging, show promise for providing unique insight into kidney function and severity of fibrosis. However, substantial limitations in accuracy and practicality limit the immediate clinical application of each method. Further development and improvement are necessary to achieve the ideal of a noninvasive image-based measure of renal fibrosis. Our brief review provides a short explanation of these emerging MRI methods and outlines the promising initial results obtained with each as well as current limitations and barriers to clinical implementation.


Assuntos
Rim/diagnóstico por imagem , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética , Técnicas de Imagem por Elasticidade , Fibrose , Humanos , Rim/irrigação sanguínea , Oxigênio/sangue
7.
Magn Reson Med ; 78(1): 297-302, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27501515

RESUMO

PURPOSE: Blood oxygen level-dependent (BOLD) MRI has been effectively used to monitor changes in renal oxygenation. However, R2* (or T2*) is not specific to blood oxygenation and is dependent on other factors. This study investigates the use of a statistical model that takes these factors into account and maps BOLD MRI measurements to blood pO2. METHODS: Spin echo and gradient echo images were obtained in six Sprague-Dawley rats and R2 and R2* maps were computed. Measurements were made at baseline, post-nitric oxide synthase inhibitor (L-NAME), and post-furosemide administration. A simulation of each region was performed to map R2' (computed as R2*-R2) to blood pO2. RESULTS: At baseline, blood pO2 in the outer medulla was 30.5 ± 1.2 mmHg and 51.9 ± 5.2 mmHg in the cortex, in agreement with previous invasive studies. Blood pO2 was found to decrease within the outer medulla following L-NAME (P < 0.05) and increase after furosemide (P < 0.05). Blood pO2 in the cortex increased following furosemide (P < 0.05). CONCLUSIONS: Model-derived blood pO2 is sensitive to pharmacological challenges, and baseline pO2 is comparable to literature values. Reporting pO2 instead of R2* could lead to a greater clinical impact of renal BOLD MRI and facilitate the identification of hypoxic regions. Magn Reson Med 78:297-302, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Testes de Função Renal/métodos , Rim/diagnóstico por imagem , Rim/metabolismo , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Oxigênio/sangue , Animais , Furosemida/administração & dosagem , Rim/efeitos dos fármacos , Masculino , NG-Nitroarginina Metil Éster/administração & dosagem , Oximetria/métodos , Consumo de Oxigênio/efeitos dos fármacos , Consumo de Oxigênio/fisiologia , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Am J Physiol Renal Physiol ; 310(2): F174-82, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26447222

RESUMO

Dynamic contrast-enhanced (DCE) MRI can provide key insight into renal function. DCE MRI is typically achieved through an injection of a gadolinium (Gd)-based contrast agent, which has desirable T1 quenching and tracer kinetics. However, significant T2* blooming effects and signal voids can arise when Gd becomes very concentrated, especially in the renal medulla and pelvis. One MRI sequence designed to alleviate T2* effects is the ultrashort echo time (UTE) sequence. In the present study, we observed T2* blooming in the inner medulla of the mouse kidney, despite using UTE at an echo time of 20 microseconds and a low dose of 0.03 mmol/kg Gd. We applied quantitative susceptibility mapping (QSM) and resolved the signal void into a positive susceptibility signal. The susceptibility values [in parts per million (ppm)] were converted into molar concentrations of Gd using a calibration curve. We determined the concentrating mechanism (referred to as the concentrating index) as a ratio of maximum Gd concentration in the inner medulla to the renal artery. The concentrating index was assessed longitudinally over a 17-wk course (3, 5, 7, 9, 13, 17 wk of age). We conclude that the UTE-based DCE method is limited in resolving extreme T2* content caused by the kidney's strong concentrating mechanism. QSM was able to resolve and confirm the source of the blooming effect to be the large positive susceptibility of concentrated Gd. UTE with QSM can complement traditional magnitude UTE and offer a powerful tool to study renal pathophysiology.


Assuntos
Rim/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Animais , Meios de Contraste , Rim/patologia , Camundongos
9.
NMR Biomed ; 29(7): 969-77, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27200499

RESUMO

Dynamic contrast-enhanced (DCE) MRI is widely used for the measurement of tissue perfusion and to assess organ function. MR renography, which is acquired using a DCE sequence, can measure renal perfusion, filtration and concentrating ability. Optimization of the DCE acquisition protocol is important for the minimization of the error propagation from the acquired signals to the estimated parameters, thus improving the precision of the parameters. Critical to the optimization of contrast-enhanced T1 -weighted protocols is the balance of the T1 -shortening effect across the range of gadolinium (Gd) contrast concentration in the tissue of interest. In this study, we demonstrate a Monte Carlo simulation approach for the optimization of DCE MRI, in which a saturation-recovery T1 -weighted gradient echo sequence is simulated and the impact of injected dose (D) and time delay (TD, for saturation recovery) is tested. The results show that high D and/or high TD cause saturation of the peak arterial signals and lead to an overestimation of renal plasma flow (RPF) and glomerular filtration rate (GFR). However, the use of low TD (e.g. 100 ms) and low D leads to similar errors in RPF and GFR, because of the Rician bias in the pre-contrast arterial signals. Our patient study including 22 human subjects compared TD values of 100 and 300 ms after the injection of 4 mL of Gd contrast for MR renography. At TD = 100 ms, we computed an RPF value of 157.2 ± 51.7 mL/min and a GFR of 33.3 ± 11.6 mL/min. These results were all significantly higher than the parameter estimates at TD = 300 ms: RPF = 143.4 ± 48.8 mL/min (p = 0.0006) and GFR = 30.2 ± 11.5 mL/min (p = 0.0015). In conclusion, appropriate optimization of the DCE MRI protocol using simulation can effectively improve the precision and, potentially, the accuracy of the measured parameters. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Taxa de Filtração Glomerular/fisiologia , Compostos Heterocíclicos/farmacocinética , Interpretação de Imagem Assistida por Computador/métodos , Rim/metabolismo , Imageamento por Ressonância Magnética/métodos , Método de Monte Carlo , Compostos Organometálicos/farmacocinética , Simulação por Computador , Meios de Contraste/farmacocinética , Feminino , Gadolínio/farmacocinética , Humanos , Aumento da Imagem/métodos , Rim/diagnóstico por imagem , Masculino , Modelos Biológicos , Modelos Estatísticos , Renografia por Radioisótopo/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
J Magn Reson Imaging ; 44(2): 317-26, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26855407

RESUMO

PURPOSE: To assess the correlation between each of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) metrics in renal parenchyma with renal function, in a cohort of patients with chronic liver disease. MATERIALS AND METHODS: Thirty patients with liver disease underwent abdominal MRI at 1.5T, including a coronal respiratory-triggered IVIM-DWI sequence and a coronal 3D FLASH DCE-MRI acquisition. Diffusion signals in the renal cortex and medulla were fitted to the IVIM model to estimate the diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF). The apparent diffusion coefficient (ADC) was calculated using all b-values. The glomerular filtration rate (GFR), cortical and medullary renal plasma flow (RPF), mean transit times (MTT) of vascular and tubular compartments and the whole kidney, were calculated from DCE-MRI data by fitting to a three-compartment model. The estimated GFR (eGFR) was calculated from serum creatinine measured 30 ± 27 days of MRI. RESULTS: ADC, PF, and RPF were significantly higher in renal cortex vs. medulla (P < 10(-5) ). DCE-MRI GFR significantly correlated with, but underestimated, eGFR (Spearman's r/P = 0.49/0.01). IVIM-DWI parameters were not significantly correlated with eGFR. DCE-MRI GFR correlated weakly with D (cortex, r/P = 0.3/0.03; medulla r/P = 0.27/0.05) and ADC (cortex r/P = 0.28/0.04; medulla r/P = 0.34/0.01). Weak correlations were observed for pooled cortical and medullar RPF with PF (r/P = 0.32/10(-3) ) and with ADC (r/P = 0.29/0.0025). Significant negative correlations were observed for vascular MTT with cortical D* (r/P = -0.38/0.004) and D*×PF (r/P = -0.34/0.01). CONCLUSION: The weak correlations between renal IVIM and DCE-MRI perfusion parameters imply that these functional measures could be complementary. J. Magn. Reson. Imaging 2016;44:317-326.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Testes de Função Renal/métodos , Rim/diagnóstico por imagem , Rim/fisiopatologia , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Idoso , Algoritmos , Simulação por Computador , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Modelos Estatísticos , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Magn Reson Imaging ; 43(2): 391-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26174884

RESUMO

PURPOSE: To evaluate the performance of an edge-based registration technique in correcting for respiratory motion artifacts in magnetic resonance renographic (MRR) data and to examine the efficiency of a semiautomatic software package in processing renographic data from a cohort of clinical patients. MATERIALS AND METHODS: The developed software incorporates an image-registration algorithm based on the generalized Hough transform of edge maps. It was used to estimate glomerular filtration rate (GFR), renal plasma flow (RPF), and mean transit time (MTT) from 36 patients who underwent free-breathing MRR at 3T using saturation-recovery turbo-FLASH. The processing time required for each patient was recorded. Renal parameter estimates and model-fitting residues from the software were compared to those from a previously reported technique. Interreader variability in the software was quantified by the standard deviation of parameter estimates among three readers. GFR estimates from our software were also compared to a reference standard from nuclear medicine. RESULTS: The time taken to process one patient's data with the software averaged 12 ± 4 minutes. The applied image registration effectively reduced motion artifacts in dynamic images by providing renal tracer-retention curves with significantly smaller fitting residues (P < 0.01) than unregistered data or data registered by the previously reported technique. Interreader variability was less than 10% for all parameters. GFR estimates from the proposed method showed greater concordance with reference values (P < 0.05). CONCLUSION: These results suggest that the proposed software can process MRR data efficiently and accurately. Its incorporated registration technique based on the generalized Hough transform effectively reduces respiratory motion artifacts in free-breathing renographic acquisitions.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Nefropatias/patologia , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
12.
Magn Reson Med ; 74(4): 1077-85, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25302780

RESUMO

PURPOSE: To compare fitting methods and sampling strategies, including the implementation of an optimized b-value selection for improved estimation of intravoxel incoherent motion (IVIM) parameters in breast cancer. METHODS: Fourteen patients (age, 48.4 ± 14.27 years) with cancerous lesions underwent 3 Tesla breast MRI examination for a HIPAA-compliant, institutional review board approved diffusion MR study. IVIM biomarkers were calculated using "free" versus "segmented" fitting for conventional or optimized (repetitions of key b-values) b-value selection. Monte Carlo simulations were performed over a range of IVIM parameters to evaluate methods of analysis. Relative bias values, relative error, and coefficients of variation (CV) were obtained for assessment of methods. Statistical paired t-tests were used for comparison of experimental mean values and errors from each fitting and sampling method. RESULTS: Comparison of the different analysis/sampling methods in simulations and experiments showed that the "segmented" analysis and the optimized method have higher precision and accuracy, in general, compared with "free" fitting of conventional sampling when considering all parameters. Regarding relative bias, IVIM parameters fp and Dt differed significantly between "segmented" and "free" fitting methods. CONCLUSION: IVIM analysis may improve using optimized selection and "segmented" analysis, potentially enabling better differentiation of breast cancer subtypes and monitoring of treatment.


Assuntos
Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Movimento (Física)
13.
Am J Physiol Renal Physiol ; 306(6): F579-87, 2014 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-24452640

RESUMO

Blood oxygen level-dependent (BOLD) MRI data of kidney, while indicative of tissue oxygenation level (Po2), is in fact influenced by multiple confounding factors, such as R2, perfusion, oxygen permeability, and hematocrit. We aim to explore the feasibility of extracting tissue Po2 from renal BOLD data. A method of two steps was proposed: first, a Monte Carlo simulation to estimate blood oxygen saturation (SHb) from BOLD signals, and second, an oxygen transit model to convert SHb to tissue Po2. The proposed method was calibrated and validated with 20 pigs (12 before and after furosemide injection) in which BOLD-derived tissue Po2 was compared with microprobe-measured values. The method was then applied to nine healthy human subjects (age: 25.7 ± 3.0 yr) in whom BOLD was performed before and after furosemide. For the 12 pigs before furosemide injection, the proposed model estimated renal tissue Po2 with errors of 2.3 ± 5.2 mmHg (5.8 ± 13.4%) in cortex and -0.1 ± 4.5 mmHg (1.7 ± 18.1%) in medulla, compared with microprobe measurements. After injection of furosemide, the estimation errors were 6.9 ± 3.9 mmHg (14.2 ± 8.4%) for cortex and 2.6 ± 4.0 mmHg (7.7 ± 11.5%) for medulla. In the human subjects, BOLD-derived medullary Po2 increased from 16.0 ± 4.9 mmHg (SHb: 31 ± 11%) at baseline to 26.2 ± 3.1 mmHg (SHb: 53 ± 6%) at 5 min after furosemide injection, while cortical Po2 did not change significantly at ∼58 mmHg (SHb: 92 ± 1%). Our proposed method, validated with a porcine model, appears promising for estimating tissue Po2 from renal BOLD MRI data in human subjects.


Assuntos
Córtex Renal/metabolismo , Medula Renal/metabolismo , Rim/irrigação sanguínea , Oxigênio/sangue , Adulto , Animais , Simulação por Computador , Feminino , Furosemida/farmacologia , Hemoglobinas/metabolismo , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Método de Monte Carlo , Pressão Parcial , Suínos
14.
Kidney Int ; 85(4): 768-78, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24067433

RESUMO

Established as a method to study anatomic changes, such as renal tumors or atherosclerotic vascular disease, magnetic resonance imaging (MRI) to interrogate renal function has only recently begun to come of age. In this review, we briefly introduce some of the most important MRI techniques for renal functional imaging, and then review current findings on their use for diagnosis and monitoring of major kidney diseases. Specific applications include renovascular disease, diabetic nephropathy, renal transplants, renal masses, acute kidney injury, and pediatric anomalies. With this review, we hope to encourage more collaboration between nephrologists and radiologists to accelerate the development and application of modern MRI tools in nephrology clinics.


Assuntos
Nefropatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Nefrologia/tendências , Animais , Humanos
15.
Magn Reson Imaging ; 111: 21-27, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38582100

RESUMO

Muscle hyperemia in exercise is usually the combined result of increased cardiac output and local muscle vasodilation, with the latter reflecting muscle's capacity for increased blood perfusion to support exercise. In this study, we aim to quantify muscle's vasodilation capability with dynamic BOLD imaging. A deoxyhemoglobin-kinetics model is proposed to analyze dynamic BOLD signals acquired during exercise recovery, deriving a hyperemia index (HI) for a muscle group of interest. We demonstrated the method's validity with calf muscles of healthy subjects who performed plantar flexion for muscle stimulation. In a test with exercise load incrementally increasing from 0 to 16 lbs., gastrocnemius HI showed considerable variance among the 4 subjects, but with a consistent trend, i.e. low at light load (e.g. 0-6 lbs) and linearly increasing at heavy load. The high variability among different subjects was confirmed with the other 10 subjects who exercised with a same moderate load of 8 lbs., with coefficient of variance among subjects' medial gastrocnemius 87.8%, lateral gastrocnemius 111.8% and soleus 132.3%. These findings align with the fact that intensive exercise induces high muscle hyperemia, but a comparison among different subjects is hard to make, presumably due to the subjects' different rate of oxygen utilization. For the same 10 subjects who exercised with load of 8 lbs., we also performed dynamic contrast enhanced (DCE) MRI to measure muscle perfusion (F). With a moderate correlation of 0.654, HI and F displayed three distinctive responses of calf muscles: soleus of all the subjects were in the cluster of low F and low HI, and gastrocnemius of most subjects had high F and either low or high HI. This finding suggests that parameter F encapsulates blood flow through vessels of all sizes, but BOLD-derived HI focuses on capillary flow and therefore is a more specific indicator of muscle vasodilation. In conclusion, the proposed hyperemia index has the potential of quantitatively assessing muscle vasodilation induced with exercise.


Assuntos
Exercício Físico , Hiperemia , Perna (Membro) , Imageamento por Ressonância Magnética , Músculo Esquelético , Oxigênio , Humanos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/irrigação sanguínea , Hiperemia/diagnóstico por imagem , Hiperemia/fisiopatologia , Masculino , Exercício Físico/fisiologia , Adulto , Imageamento por Ressonância Magnética/métodos , Perna (Membro)/irrigação sanguínea , Perna (Membro)/diagnóstico por imagem , Oxigênio/sangue , Feminino , Reprodutibilidade dos Testes , Adulto Jovem , Vasodilatação/fisiologia
16.
Radiology ; 269(3): 625-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24261489

RESUMO

Despite being a valuable tool for evaluation of the kidneys, renal magnetic resonance (MR) imaging in clinical practice has been limited to depiction of anatomy and provides little diagnostic information about the health and function of the kidney in patients with chronic kidney disease (CKD) and diabetic nephropathy. In this issue, Peng et al (1) have used two MR imaging methods that go beyond depiction of anatomy to show renal function: renal blood oxygen level-dependent (BOLD) MR imaging, which shows oxygen levels in the kidney, and chemical shift-selective imaging, which shows the relative content of fat in the kidney parenchyma. In a mouse model of diabetes, Peng et al have shown higher fat and lower oxygen levels in kidneys of mice with diabetes than in those of normal controls. These MR imaging methods may help clarify the role of fat deposition and hypoxia in the progression of CKD. As the factors that contribute to the progression of CKD are better understood, ultimately more widespread clinical use for functional renal MR imaging protocols such as renal BOLD and chemical shift-selective imaging may be found to evaluate the severity of CKD and monitor the efficacy of clinical interventions, altering the course of disease progression.


Assuntos
Nefropatias Diabéticas/metabolismo , Rim/metabolismo , Metabolismo dos Lipídeos , Imageamento por Ressonância Magnética/métodos , Oxigênio/sangue , Animais , Masculino
17.
J Magn Reson Imaging ; 37(2): 282-93, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23355431

RESUMO

Renal function is characterized by different physiologic aspects, including perfusion, glomerular filtration, interstitial diffusion, and tissue oxygenation. Magnetic resonance imaging (MRI) shows great promise in assessing these renal tissue characteristics noninvasively. The last decade has witnessed a dramatic progress in MRI techniques for renal function assessment. This article briefly describes relevant renal anatomy and physiology, reviews the applications of functional MRI techniques for the diagnosis of renal diseases, and lists unresolved issues that will require future work.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Nefropatias/diagnóstico , Nefropatias/fisiopatologia , Testes de Função Renal/métodos , Rim/patologia , Rim/fisiopatologia , Humanos
18.
Sci Rep ; 13(1): 19191, 2023 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-37932431

RESUMO

Susceptibility artifact (SA) is common in renal blood oxygenation level-dependent (BOLD) images, and including the SA-affected region could induce much error in renal oxygenation quantification. In this paper, we propose to exclude kidney regions affected by SA in gradient echo images with different echo times (TE), based on a deep-learning segmentation approach. For kidney segmentation, a ResUNet was trained with 4000 CT images and then tuned with 60 BOLD images. Verified by a Monte Carlo simulation, the presence of SA leads to a bilinear pattern for the segmented area of kidney as function of TE, and the segmented kidney in the image of turning point's TE would exclude SA-affected regions. To evaluate the accuracy of excluding SA-affected regions, we compared the SA-free segmentations by the proposed method against manual segmentation by an experienced user for BOLD images of 35 subjects, and found DICE of 93.9% ± 3.4%. For 10 kidneys with severe SA, the DICE was 94.5% ± 1.7%, for 14 with moderate SA, 92.8% ± 4.7%, and for 46 with mild or no SA, 94.3% ± 3.8%. For the three sub-groups of kidneys, correction of SA led to a decrease of R2* of 8.5 ± 2.8, 4.7 ± 1.8, and 1.6 ± 0.9 s-1, respectively. In conclusion, the proposed method is capable of segmenting kidneys in BOLD images and at the same time excluding SA-affected region in a fully automatic way, therefore can potentially improve both speed and accuracy of the quantification procedure of renal BOLD data.


Assuntos
Artefatos , Aprendizado Profundo , Humanos , Rim , Processamento de Imagem Assistida por Computador/métodos
19.
Magn Reson Med ; 67(1): 89-97, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21702062

RESUMO

Diffusion-weighted imaging (DWI) involves data acquisitions at multiple b values. In this paper, we presented a method of selecting the b values that maximize estimation precision of the biexponential analysis of renal DWI data. We developed an error propagation factor for the biexponential model, and proposed to optimize the b-value samplings by minimizing the error propagation factor. A prospective study of four healthy human subjects (eight kidneys) was done to verify the feasibility of the proposed protocol and to assess the validity of predicted precision for DWI measures, followed by Monte Carlo simulations of DWI signals based on acquired data from renal lesions of 16 subjects. In healthy subjects, the proposed methods improved precision (P = 0.003) and accuracy (P < 0.001) significantly in region-of-interest based biexponential analysis. In Monte Carlo simulation of renal lesions, the b-sampling optimization lowered estimation error by at least 20-30% compared with uniformly distributed b values, and improved the differentiation between malignant and benign lesions significantly. In conclusion, the proposed method has the potential of maximizing the precision and accuracy of the biexponential analysis of renal DWI.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Rim/anatomia & histologia , Interpretação Estatística de Dados , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade
20.
Radiology ; 260(3): 781-9, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21771953

RESUMO

PURPOSE: To assess prospectively the ability of quantitative low-dose three-dimensional magnetic resonance (MR) renography to help identify the cause of acute graft dysfunction. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board, and written informed consent was obtained. Between December 2001 and May 2009, sixty patients with transplanted kidneys (41 men and 19 women; mean age, 49 years; age range, 22-71 years) were included. Thirty-one patients had normal function and 29 had acute dysfunction due to acute rejection (n = 12), acute tubular necrosis (ATN) (n = 8), chronic rejection (n = 6), or drug toxicity (n = 3). MR renography was performed at 1.5 T with three-dimensional gradient-echo imaging. With use of a multicompartment renal model, the glomerular filtration rate (GFR) and the mean transit time (MTT) of the tracer for the vascular compartment (MTT(A)), the tubular compartment (MTT(T)), and the collecting system compartment (MTT(C)) were calculated. Also derived was MTT for the whole kidney (MTT(K) = MTT(A) + MTT(T) + MTT(C)) and fractional MTT of each compartment (MTT(A/K) = MTT(A)/MTT(K), MTT(T/K) = MTT(T)/MTT(K), MTT(C/K) = MTT(C)/MTT(K)). These parameters were compared in patients in the different study groups. Statistical analysis was performed by using analysis of covariance. RESULTS: There were significant differences in GFR and MTT(K) between the acute dysfunction group (36.4 mL/min ± 20.8 [standard deviation] and 177.1 seconds ± 46.8, respectively) and the normal function group (65.9 mL/min ± 27.6 and 140.5 seconds ± 51.8, respectively) (P < .001 and P = .004). The MTT(A/K) was significantly higher in the acute rejection group (mean, 12.7% ± 2.9) than in the normal function group (mean, 8.3% ± 2.2; P < .001) or in the ATN group (mean, 7.1% ± 1.4; P < .001). The MTT(T/K) was significantly higher in the ATN group (mean, 83.2% ± 9.2) than in the normal function group (mean, 72.4% ± 10.2; P = .031) or in the acute rejection group (mean, 69.2% ± 6.1; P = .003). CONCLUSION: Low-dose MR renography analyzed by using a multicompartmental tracer kinetic renal model may help to differentiate noninvasively between acute rejection and ATN after kidney transplantation.


Assuntos
Injúria Renal Aguda/etiologia , Injúria Renal Aguda/patologia , Imageamento Tridimensional/métodos , Transplante de Rim/efeitos adversos , Transplante de Rim/patologia , Imageamento por Ressonância Magnética/métodos , Renografia por Radioisótopo/métodos , Adulto , Idoso , Humanos , Técnicas In Vitro , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Falha de Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA