Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
BMC Med ; 22(1): 153, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609953

RESUMO

BACKGROUND: Prediction of lymph node metastasis (LNM) is critical for individualized management of papillary thyroid carcinoma (PTC) patients to avoid unnecessary overtreatment as well as undesired under-treatment. Artificial intelligence (AI) trained by thyroid ultrasound (US) may improve prediction performance. METHODS: From September 2017 to December 2018, patients with suspicious PTC from the first medical center of the Chinese PLA general hospital were retrospectively enrolled to pre-train the multi-scale, multi-frame, and dual-direction deep learning (MMD-DL) model. From January 2019 to July 2021, PTC patients from four different centers were prospectively enrolled to fine-tune and independently validate MMD-DL. Its diagnostic performance and auxiliary effect on radiologists were analyzed in terms of receiver operating characteristic (ROC) curves, areas under the ROC curve (AUC), accuracy, sensitivity, and specificity. RESULTS: In total, 488 PTC patients were enrolled in the pre-training cohort, and 218 PTC patients were included for model fine-tuning (n = 109), internal test (n = 39), and external validation (n = 70). Diagnostic performances of MMD-DL achieved AUCs of 0.85 (95% CI: 0.73, 0.97) and 0.81 (95% CI: 0.73, 0.89) in the test and validation cohorts, respectively, and US radiologists significantly improved their average diagnostic accuracy (57% vs. 60%, P = 0.001) and sensitivity (62% vs. 65%, P < 0.001) by using the AI model for assistance. CONCLUSIONS: The AI model using US videos can provide accurate and reproducible prediction of cervical lymph node metastasis in papillary thyroid carcinoma patients preoperatively, and it can be used as an effective assisting tool to improve diagnostic performance of US radiologists. TRIAL REGISTRATION: We registered on the Chinese Clinical Trial Registry website with the number ChiCTR1900025592.


Assuntos
Inteligência Artificial , Neoplasias da Glândula Tireoide , Humanos , Metástase Linfática/diagnóstico por imagem , Estudos Prospectivos , Estudos Retrospectivos , Câncer Papilífero da Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem
2.
Eur Radiol ; 34(7): 4716-4726, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38170265

RESUMO

OBJECTIVES: To assess the safety and efficacy of radiofrequency ablation (RFA) for capsular-located papillary thyroid microcarcinoma (PTMC) in a large cohort and to compare its outcomes with those of noncapsular-located PTMC. METHODS: We retrospectively reviewed patients who underwent RFA for solitary capsular-located and noncapsular-located low-risk PTMC (n = 1095) from June 2014 to October 2020. To balance confounding variables between capsular and noncapsular groups, we employed the 1:1 propensity score matching approach. We evaluated and compared tumor changes, disease progression, and complications in both groups. Furthermore, we analyzed the association between capsular location and disease progression using multivariable Cox regression. RESULTS: During a mean follow-up time of 29.86 ± 16.14 months and 29.73 ± 15.69 months, no substantial difference was observed between capsular and noncapsular groups in the latest volume (0.83 ± 3.66 mm3 vs. 0.85 ± 3.67 mm3, p = 0.44) and volume reduction ratio (99.29 ± 4.04% vs. 99.43 ± 3.03%, p = 0.43), and cumulative disappearance rate (87.87% vs. 86.07%, p = 0.31). In addition, no significant differences were observed in complication incidence (1.35% vs. 1.12%, p = 0.76) and progression-free survival (p = 0.53). Based on adjusted multivariate Cox proportional hazard analysis, the association between capsular location and disease progression was nonsignificant (all p > 0.05). CONCLUSION: This study demonstrates that the short-term outcomes of RFA for capsular-located PTMCs are comparable to those of noncapsular-located PTMCs. These findings indicate that RFA may be a viable and effective alternative for eligible patients with solitary capsular-located PTMC. CLINICAL RELEVANCE STATEMENT: Radiofrequency ablation may serve as a safe and effective alternative treatment method for eligible patients with capsular-located and noncapsular-located papillary thyroid microcarcinoma. KEY POINTS: • The safety and efficacy of radiofrequency ablation for capsular-located and noncapsular-located papillary thyroid microcarcinomas were comparable. • Disease progression did not differ significantly between capsular-located and noncapsular-located papillary thyroid microcarcinomas. • The incidence of complications for capsular-located papillary thyroid microcarcinoma was low.


Assuntos
Carcinoma Papilar , Pontuação de Propensão , Ablação por Radiofrequência , Neoplasias da Glândula Tireoide , Humanos , Feminino , Masculino , Neoplasias da Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/patologia , Estudos Retrospectivos , Ablação por Radiofrequência/métodos , Pessoa de Meia-Idade , Adulto , Carcinoma Papilar/cirurgia , Resultado do Tratamento , Progressão da Doença , Idoso
3.
Int J Hyperthermia ; 41(1): 2270671, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38214143

RESUMO

OBJECTIVE: To evaluate the outcomes of radiofrequency ablation (RFA) for papillary thyroid microcarcinoma (PTMC) adjacent to the trachea and compare them with those of PTMC distant from the trachea. METHODS: Patients who received RFA for solitary low-risk PTMC between June 2014 and July 2020 were reviewed and classified into adjacent and distant groups. To balance between-group confounders, the propensity score matching approach was employed. Volume, volume reduction ratio (VRR), tumor disappearance, complications, and disease progression were assessed and compared between the groups. Furthermore, factors affecting disease progression were evaluated. RESULTS: A total of 122 and 470 patients were included in the adjacent and distant groups, respectively. Overall VRR was 99.5% ± 3.1 and cumulative tumor disappearance rate was 99.4% after a mean follow-up time of 40.1 months ± 16.2. Overall disease progression and complications incidence were 3.7% and 1.0%, respectively. No substantial differences were observed between the two groups in the latest volume (0.8 mm3 ± 4.1 vs. 0.9 mm3 ± 4.2, p = .77), VRR (99.7% ± 1.6 vs. 99.5% ± 2.7, p = .75), cumulative tumor disappearance rate (92.6% vs. 94.2%, p = .58), and incidence of disease progression (4.1% vs. 4.5%, p = .70) and complication (1.7% vs. 0.8%, p = .86) after 1:2 matching. Additionally, tracheal adjacency exhibited no association with disease progression in multivariate Cox regression analysis (p = .73). CONCLUSION: For eligible patients with PTMC located adjacent to or distant from the trachea, RFA may offer a safe and effective alternative treatment method.


Assuntos
Carcinoma Papilar , Ablação por Radiofrequência , Neoplasias da Glândula Tireoide , Humanos , Traqueia/cirurgia , Traqueia/patologia , Neoplasias da Glândula Tireoide/radioterapia , Neoplasias da Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/patologia , Ablação por Radiofrequência/métodos , Progressão da Doença , Estudos Retrospectivos , Resultado do Tratamento
4.
Ultrasonography ; 43(2): 79-87, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38310872

RESUMO

Papillary thyroid carcinoma (PTC) is a highly prevalent cancer that typically exhibits indolent behavior and is associated with a favorable prognosis. The treatment of choice is surgical intervention; however, this approach carries the risk of complications, including scarring and loss of thyroid function. Although active surveillance can mitigate the risk of PTC overtreatment, the possibility of tumor growth and metastasis can elicit anxiety among patients. Ultrasoundguided thermal ablation has emerged as a safe and effective alternative for individuals who are ineligible for or decline surgery. This article provides a review of the clinical research on radiofrequency ablation as a treatment for PTC, offering a thorough examination of its efficacy, safety, and future perspectives.

5.
Micromachines (Basel) ; 15(3)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38542598

RESUMO

This paper presents a MEMS electrochemical angular accelerometer with a silicon-based four-electrode structure, which was made of thousands of interconnected microchannels for electrolyte flow, anodes uniformly coated on structure surfaces and cathodes located on the sidewalls of flow holes. From the perspective of device fabrication, in this study, the previously reported multi-piece assembly was simplified into single-piece integrative manufacturing, effectively addressing the problems of complex assembly and manual alignment. From the perspective of the sensitive structure, in this study, the silicon-based four-electrode structure featuring with complete insulation layers between anodes and cathodes can enable fast electrochemical reactions with improved sensitivities. Numerical simulations were conducted to optimize the geometrical parameters of the silicon-based four-electrode structure, where increases in fluid resistance and cathode area were found to expand working bandwidths and improve device sensitivity, respectively. Then, the silicon-based four-electrode structure was fabricated by conventional MEMS processes, mainly composed of wafer-level bonding and wafer-level etching. As to device characterization, the MEMS electrochemical angular accelerometer with the silicon-based four-electrode structure exhibited a maximum sensitivity of 1458 V/(rad/s2) at 0.01 Hz and a minimum noise level of -164 dB at 1 Hz. Compared with previously reported electrochemical angular accelerometers, the angular accelerometer developed in this study offered higher sensitivities and lower noise levels, indicating strong potential for applications in the field of rotational seismology.

6.
Orthop J Sports Med ; 12(2): 23259671231224497, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38343647

RESUMO

Background: An accurate and objective criterion is needed to determine candidates who are suitable for hip arthroscopy in patients with femoroacetabular impingement (FAI). Purpose: To determine whether improvement in pain after ultrasound (US)-guided intra-articular hip injection during standardized examinations can be used to predict the outcomes of hip arthroscopy in patients with FAI. Study Design: Cohort study; Level of evidence, 3. Methods: We enrolled 119 patients with FAI who underwent US-guided intra-articular hip injection of local anesthesia during standardized examinations, carried out from May 2018 to February 2020 (within 2 weeks before hip arthroscopy). All patients had undergone a minimum of 6 months of nonoperative treatment without remission and had 2-year follow-up data. Pain visual analog scale (VAS) scores (0-10) were recorded for 7 different physical examination tests, and a total score (0 [best] to 70 [worst]) was obtained. In addition, International Hip Outcome Tool-12 (iHOT-12) and modified Harris Hip Score (mHHS) scores were recorded before hip arthroscopy and at final follow-up. According to whether patients achieved the substantial clinical benefit (SCB) on the iHOT-12, they were divided into SCB and non-SCB groups, and the improvement in VAS pain scores from preinjection to postinjection (ΔVAS pain) was compared between the 2 groups. Logistic regression analysis was used to predict the achievement of SCB, and the area under the receiver operating characteristic curve (AUC) was used to estimate the accuracy of the prediction. Results: There was a significant pre- to postoperative increase in iHOT-12 (31.6 points; P < .001) and mHHS (20.0 points; P < .001) scores, and 84 (70.6%) patients achieved the SCB. The ΔVAS pain score was significantly greater in the SCB versus the non-SCB group (16.0 vs 7.0 points; respectively; P < .001). Logistic regression analysis demonstrated an optimal cutoff value of 8.5 points for ΔVAS pain (AUC, 0.772; 95% CI, 0.687-0.858). For patients with more severe symptoms (total preinjection VAS pain score of >10 out of 70), the accuracy of the prediction for ΔVAS pain had a better evaluation value (AUC, 0.834; 95% CI, 0.676-0.992). Conclusion: Improvement in pain after US-guided intra-articular hip injection predicted the outcomes of hip arthroscopy in patients with FAI in this study, especially for patients with more severe pain.

7.
Endocrine ; 85(3): 1066-1074, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38801598

RESUMO

PURPOSE: To evaluate the safety and efficacy of radiofrequency ablation (RFA) in treating locoregional recurrent thyroid cancer (LRTC) after a 2-year follow-up time. METHODS: PubMed, Embase and Cochrane Library were searched from inception until 20 September 2022 to find studies reporting the safety and efficacy of RFA in LRTC patients after a 2-year follow-up. Two radiologists performed the data extraction and methodological quality assessment according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. RESULTS: We analyzed 6 studies, 229 LRTC patients with 319 locally recurrent tumors were treated with RFA. The mean follow-up time of each study was ≥24 months. The pooled changes in the largest diameter and volume were 7.22 mm (95% confidence interval (CI), 6.35-8.09 mm) and 164.28 mm3 (95% CI, 87.78-240.77 mm3), respectively; the pooled volume reduction rate was 95.03% (95% CI, 87.56-102.49%). The total complete disappearance rate after treatment was 92% (95% CI, 83-100%). The pooled decrease of serum thyroglobulin levels was 0.02 ng/ml (95% CI, -0.00-0.04 ng/ml). The pooled proportion of recurrence rate was 6% (95% CI, 0-13%). The pooled complication rate was 5% (95% CI, 0-10%). The major complications were voice change and hoarseness, only one patient developed permanent vocal cord paralysis; minor complications were cough and pain. CONCLUSIONS: Ultrasound-guided RFA is an effective and safe treatment for LRTC based on 2-year follow-up results.


Assuntos
Recidiva Local de Neoplasia , Ablação por Radiofrequência , Neoplasias da Glândula Tireoide , Humanos , Neoplasias da Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/radioterapia , Ablação por Radiofrequência/métodos , Resultado do Tratamento , Seguimentos
8.
Braz. j. med. biol. res ; 51(4): e7058, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889071

RESUMO

This study aimed to evaluate the feasibility and repeatability of the flash-replenishment method in contrast-enhanced ultrasound (CEUS) perfusion imaging and assess quantitatively microvascular perfusion in the liver. Twenty healthy New Zealand rabbits were submitted to CEUS perfusion imaging with continuous intravenous infusion. Using flash-replenishment kinetics, the dynamic process of depletion and refilling of microbubble contrast agent was recorded. The hepatic microvascular perfusion parameters were calculated, including region of interest, peak intensity (PI), area under the curve (AUC), and hepatic artery to vein transit time (HA-HVTT). A consistency test was performed for multiple measurements by the same operator and blind measurements by two different operators. The hepatic perfusion imaging of 3×108 bubbles/min had minimal error and the best imaging effect and repeatability. The variability of the perfusion parameter measured at 3 cm depth under the liver capsule was at a minimum with coefficient of variation of 3.9%. The interclass correlation coefficient (ICC) of measurements taken by the same operator was 0.985, (95% confidence interval, CI=0.927-0.998). Measurements taken by two operators had good consistency and reliability, with the ICC of 0.948 (95%CI=0.853-0.982). The PI and AUC of liver parenchyma after reperfusion were lower than before blocking; and HA-HVTT was significantly longer than before blocking (P<0.05). The flash-replenishment method in CEUS perfusion imaging showed good stability and repeatability, which provide a valuable experimental basis for the quantitative assessment of hepatic microvascular perfusion in clinical practice.


Assuntos
Animais , Masculino , Feminino , Coelhos , Traumatismo por Reperfusão/diagnóstico por imagem , Ultrassonografia/métodos , Isquemia/fisiopatologia , Fígado/irrigação sanguínea , Circulação Hepática/fisiologia , Velocidade do Fluxo Sanguíneo , Aumento da Imagem/métodos , Distribuição Aleatória , Estudos de Viabilidade , Reprodutibilidade dos Testes , Meios de Contraste , Modelos Animais de Doenças , Fígado/diagnóstico por imagem , Microcirculação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA