Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 92(2): 676-687, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38523575

RESUMO

PURPOSE: Abnormal adherence at functional myofascial interfaces is hypothesized as an important phenomenon in myofascial pain syndrome. This study aimed to investigate the feasibility of MR elastography (MRE)-based slip interface imaging (SII) to visualize and assess myofascial mobility in healthy volunteers. METHODS: SII was used to assess local shear strain at functional myofascial interfaces in the flexor digitorum profundus (FDP) and thighs. In the FDP, MRE was performed at 90 Hz vibration to each index, middle, ring, and little finger. Two thigh MRE scans were performed at 40 Hz with knees flexed and extended. The normalized octahedral shear strain (NOSS) maps were calculated to visualize myofascial slip interfaces. The entropy of the probability distribution of the gradient NOSS was computed for the two knee positions at the intermuscular interface between vastus lateralis and vastus intermedius, around rectus femoris, and between vastus intermedius and vastus medialis. RESULTS: NOSS map depicted distinct functional slip interfaces in the FDP for each finger. Compared to knee flexion, clearer slip interfaces and larger gradient NOSS entropy at the vastus lateralis-vastus intermedius interface were observed during knee extension, where the quadriceps are not passively stretched. This suggests the optimal position for using SII to visualize myofascial slip interface in skeletal muscles is when muscles are not subjected to any additional force. CONCLUSION: The study demonstrated that MRE-based SII can visualize and assess myofascial interface mobility in extremities. The results provide a foundation for investigating the hypothesis that myofascial pain syndrome is characterized by changes in the mobility of myofascial interfaces.


Assuntos
Técnicas de Imagem por Elasticidade , Estudos de Viabilidade , Humanos , Técnicas de Imagem por Elasticidade/métodos , Masculino , Adulto , Feminino , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Síndromes da Dor Miofascial/diagnóstico por imagem , Síndromes da Dor Miofascial/fisiopatologia , Coxa da Perna/diagnóstico por imagem , Adulto Jovem , Voluntários Saudáveis
2.
Skeletal Radiol ; 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37943305

RESUMO

Lunotriquetral coalitions are the most common form of carpal coalition wherein the cartilage between the lunate and triquetrum ossification centers failed to undergo apoptosis. This technical case report examines the arthrokinematics of bilateral lunotriquetral coalitions with dissimilar Minnaar types in one participant with one asymptomatic wrist and one wrist with suspected distal radioulnar joint injury. Static and dynamic (four-dimensional) CT images during pronosupination were captured using a photon-counting detector CT scanner. Interosseous proximity distributions were calculated between the lunotriquetral coalition and adjacent bones in both wrists to quantify arthrokinematics. Interosseous proximity distributions at joints adjacent to the lunotriquetral coalition demonstrate differences in median and minimum interosseous proximities between the asymptomatic and injured wrists during resisted pronosupination. Altered kinematics from lunotriquetral coalitions may be a source of ulnar-sided wrist pain and discomfort, limiting the functional range of motion. This case report highlights potential alterations to wrist arthrokinematics in the setting of lunotriquetral coalitions and possible associations with ulnar-sided wrist pain, highlighting anatomy to examine in radiographic follow-up. Furthermore, this case report demonstrates the technical feasibility of four-dimensional CT using photon-counting detector technology in assessing arthrokinematics in the setting of variant wrist anatomy.

3.
Sensors (Basel) ; 21(4)2021 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-33578639

RESUMO

Arm use in manual wheelchair (MWC) users is characterized by a combination of overuse and a sedentary lifestyle. This study aimed to describe the percentage of daily time MWC users and able-bodied individuals spend in each arm use intensity level utilizing accelerometers. Arm use intensity levels of the upper arms were defined as stationary, low, mid, and high from the signal magnitude area (SMA) of the segment accelerations based on in-lab MWC activities performed by eight MWC users. Accelerometry data were collected in the free-living environments from forty MWC users and 40 sex- and age-matched able-bodied individuals. The SMA intensity levels were applied to the free-living data and the percentage of time spent in each level was calculated. The SMA intensity levels were defined as, stationary: ≤0.67 g, low: 0.671-3.27 g, mid: 3.27-5.87 g, and high: >5.871 g. The dominant arm of both MWC users and able-bodied individuals was stationary for most of the day and less than one percent of the day was spent in high intensity arm activities. Increased MWC user age correlated with increased stationary arm time (R = 0.368, p = 0.019). Five and eight days of data are needed from MWC users and able-bodied individuals, respectively, to achieve reliable representation of their daily arm use intensities.


Assuntos
Acelerometria , Pessoas com Deficiência , Traumatismos da Medula Espinal , Cadeiras de Rodas , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
4.
Neuromodulation ; 22(3): 244-252, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30840354

RESUMO

BACKGROUND: Traumatic spinal cord injury (SCI) disrupts signaling pathways between the brain and spinal networks below the level of injury. In cases of severe SCI, permanent loss of sensorimotor and autonomic function can occur. The standard of care for severe SCI uses compensation strategies to maximize independence during activities of daily living while living with chronic SCI-related dysfunctions. Over the past several years, the research field of spinal neuromodulation has generated promising results that hold potential to enable recovery of functions via epidural electrical stimulation (EES). METHODS: This review provides a historical account of the translational research efforts that led to the emergence of EES of the spinal cord to enable intentional control of motor functions that were lost after SCI. We also highlight the major limitations associated with EES after SCI and propose future directions of spinal neuromodulation research. RESULTS: Multiple, independent studies have demonstrated return of motor function via EES in individuals with chronic SCI. These enabled motor functions include intentional, controlled movement of previously paralyzed extremities, independent standing and stepping, and increased grip strength. In addition, improvements in cardiovascular health, respiratory function, body composition, and urologic function have been reported. CONCLUSIONS: EES holds promise to enable functions thought to be permanently lost due to SCI. However, EES is currently restricted to scientific investigation in humans with SCI and requires further validation of factors such as safety and efficacy before clinical translation.


Assuntos
Espaço Epidural/fisiologia , Rede Nervosa/fisiologia , Desempenho Psicomotor/fisiologia , Recuperação de Função Fisiológica/fisiologia , Traumatismos da Medula Espinal/terapia , Estimulação da Medula Espinal/tendências , Humanos , Córtex Sensório-Motor/fisiologia , Medula Espinal/fisiologia , Traumatismos da Medula Espinal/fisiopatologia , Estimulação da Medula Espinal/métodos
5.
Arch Phys Med Rehabil ; 98(10): 2021-2027.e2, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28322758

RESUMO

OBJECTIVE: To quantify and compare spinal curvature and shoulder kinematics throughout the manual wheelchair (MWC) propulsion cycle for individuals with spinal cord injury (SCI) who were seated at 2 different seat dump angles. DESIGN: Single-group, repeated-measures study. SETTING: Academic medical center. PARTICIPANTS: Individuals (N=28) with SCI or spinal cord disease who used MWCs completed a telephone screening, and 21 of them were eligible and completed the study. INTERVENTIONS: Participants' personal MWCs were modified to have seat dump angles of 0° or 14°, with a vertical backrest. Participants completed at least 3 propulsion cycles in each condition, during which spine and shoulder motion data were collected with fiberoptic and electromagnetic sensors, respectively. MAIN OUTCOME MEASURES: Thoracolumbar spinal curvature, glenohumeral kinematics, and scapulothoracic kinematics at the start of push (SP), mid-push (MP), end of push (EP), and mid-recovery. RESULTS: Participants had significantly less lordosis in the 14° condition for all propulsion events. Median differences ranged from 2.0° to 4.6°. Lordosis differences were more pronounced in those with low SCI. Scapulothoracic internal rotation was increased in the 14° condition at SP and MP (mean differences, 2.5° and 2.7°, respectively). Relative downward rotation increased in the 14° condition at SP and MP (mean differences, 2.4° and 2.1°, respectively). Scapulothoracic differences were more pronounced in those with high SCI. No glenohumeral rotations were significantly different between the conditions. CONCLUSIONS: Scapulothoracic kinematics and spinal curvature differences during propulsion may be associated with the position of other body segments or postural stability. Because no differences were observed at the glenohumeral joint, the risk of subacromial impingement may not be affected by this seat angle change.


Assuntos
Desenho de Equipamento , Lordose/fisiopatologia , Articulação do Ombro/fisiopatologia , Doenças da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/fisiopatologia , Cadeiras de Rodas , Adulto , Fenômenos Biomecânicos/fisiologia , Pessoas com Deficiência , Feminino , Humanos , Masculino , Postura/fisiologia
6.
J Neuroeng Rehabil ; 14(1): 124, 2017 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-29187203

RESUMO

BACKGROUND: Roughly one-quarter of upper limb prosthesis users reject their prosthesis. Reasons for rejection range from comfort, to cost, aesthetics, function, and more. This paper follows a single user from training with and testing of a novel upper-limb myoelectric prosthesis (the SoftHand Pro) for participation in the CYBATHLON rehearsal to training for and competing in the CYBATHLON 2016 with a figure-of-nine harness controlled powered prosthesis (SoftHand Pro-H) to explore the feasibility and usability of a flexible anthropomorphic prosthetic hand. METHODS: The CYBATHLON pilot took part in multiple in-lab training sessions with the SoftHand Pro and SoftHand Pro-H; these sessions focused on basic control and use of the prosthetic devices and direct training of the tasks in the CYBATHLON. He used these devices in competition in the Powered Arm Prosthesis Race in the CYBATHLON rehearsal and 2016 events. RESULTS: In training for the CYBATHLON rehearsal, the subject was able to quickly improve performance with the myoelectric SHP despite typically using a body-powered prosthetic hook. The subject improved further with additional training using the figure-of-nine harness-controlled SHPH in preparation for the CYBATHLON. The Pilot placed 3rd (out of 4) in the rehearsal. In the CYBATHLON, he placed 5th (out of 12) and was one of only two pilots who successfully completed all tasks in the competition, having the second-highest score overall. CONCLUSIONS: Results with the SoftHand Pro and Pro-H suggest it to be a viable alternative to existing anthropomorphic hands and show that the unique flexibility of the hand is easily learned and exploited.


Assuntos
Membros Artificiais , Terapia por Exercício/métodos , Exercício Físico/fisiologia , Desenho de Prótese , Mãos , Humanos , Masculino
7.
J Biomech Eng ; 138(5): 054502, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26974192

RESUMO

Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion-extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar-sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2-S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17-0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion-extension are likely robust, even when patient alignment is not perfect.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiologia , Fenômenos Mecânicos , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Fluoroscopia , Humanos , Movimento
8.
J Biomech Eng ; 137(8): 084501, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25839321

RESUMO

Dynamic loading on articular joints is essential for the evaluation of the risk of the articulation degeneration associated with occupational activities. In the current study, we analyzed the dynamic constraint loading for the thumb during pipetting. The constraint loading is considered as the loading that has to be carried by the connective tissues of the joints (i.e., the cartilage layer and the ligaments) to maintain the kinematic constraints of the system. The joint loadings are solved using a classic free-body approach, using the external loading and muscle forces, which were obtained in an inverse dynamic approach combined with an optimization procedure in anybody. The constraint forces in the thumb joint obtained in the current study are compared with those obtained in the pinch and grasp tests in a previous study (Cooney and Chao, 1977, "Biomechanical Analysis of Static Forces in the Thumb During Hand Function," J. Bone Joint Surg. Am., 59(1), pp. 27-36). The maximal compression force during pipetting is approximately 83% and 60% greater than those obtained in the tip pinch and key pinch, respectively, while substantially smaller than that obtained during grasping. The maximal lateral shear force is approximately six times, 32 times, and 90% greater than those obtained in the tip pinch, key pinch, and grasp, respectively. The maximal dorsal shear force during pipetting is approximately 3.2 and 1.4 times greater than those obtained in the tip pinch and key pinch, respectively, while substantially smaller than that obtained during grasping. Our analysis indicated that the thumb joints are subjected to repetitive, intensive loading during pipetting, compared to other daily activities.


Assuntos
Articulações Carpometacarpais/fisiologia , Força da Mão/fisiologia , Polegar/fisiologia , Fenômenos Biomecânicos , Humanos , Suporte de Carga
9.
Arch Phys Med Rehabil ; 95(10): 1810-1817.e2, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24887534

RESUMO

OBJECTIVE: To test the effectiveness of a high-dose home exercise/telerehabilitation program for manual wheelchair users who have a spinal cord injury (SCI) by determining whether the intervention would reduce pain and increase function, as we hypothesized. DESIGN: A pre-post trial with outcomes measured at 3 time points: baseline, postintervention (12wk), and follow-up (>24 wk). SETTING: Subjects performed an exercise program at their homes using telerehabilitation for therapist monitoring of technique and exercise advancement. Baseline and postintervention data were collected at a motion analysis laboratory in a tertiary medical center. PARTICIPANTS: A convenience sample of manual wheelchair users (N=16, 3 women; average age, 41y; average time in a wheelchair, 16y) with shoulder pain (average pain duration, 9y) and mechanical impingement signs on physical examination. INTERVENTIONS: A 12-week home exercise program of rotator cuff and scapular stabilization exercises was given to each participant. The program included a high dose of 3 sets of 30 repetitions, 3 times weekly, and regular physical therapist supervision via videoconferencing. MAIN OUTCOME MEASURES: Primary outcomes of pain and function were measured with the Wheelchair User's Shoulder Pain Index (WUSPI), Disabilities of Arm, Shoulder, and Hand (DASH) Index, and Shoulder Rating Questionnaire (SRQ). Secondary outcomes of strength were measured with isometric strength tests of scapulothoracic and glenohumeral muscles, and a static fatigue test of the lower trapezius. RESULTS: Pain was reduced and function improved after the intervention. There was a significant main effect for pain and function between the 3 time points based on the Friedman signed-ranked test, WUSPI (χ(2)2=5.10, P=.014), DASH Index (χ(2)2=5.41, P=.012), and SRQ (χ(2)2=23.71, P≤.001). Wilcoxon signed-rank tests demonstrated that isometric strength measurements of the serratus anterior and scapular retractors increased after the exercise intervention ([t=2.42, P=.04] and [t=4.67, P=.003], respectively). Muscle impulse produced by the lower trapezius during a fatigue task also improved (t=2.2, P=.02). No differences were measured in isometric strength for the lower trapezius, glenohumeral rotators, and abductors between the baseline and 12-week time points. CONCLUSIONS: A high-dose scapular stabilizer and rotator cuff strengthening program using telerehabilitation for supervision holds promise for shoulder pain treatment in manual wheelchair users with SCI. Additional work is needed to determine the effectiveness compared with other interventions, as well as the potential for earlier intervention to prevent development of shoulder pain.


Assuntos
Terapia por Exercício/métodos , Força Muscular , Síndrome de Colisão do Ombro/reabilitação , Articulação do Ombro/fisiopatologia , Dor de Ombro/reabilitação , Cadeiras de Rodas/efeitos adversos , Adulto , Feminino , Humanos , Contração Isométrica , Masculino , Pessoa de Meia-Idade , Fadiga Muscular , Medição da Dor , Cooperação do Paciente , Manguito Rotador/fisiopatologia , Ombro/fisiopatologia , Síndrome de Colisão do Ombro/etiologia , Síndrome de Colisão do Ombro/fisiopatologia , Dor de Ombro/etiologia , Dor de Ombro/fisiopatologia , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/fisiopatologia , Músculos Superficiais do Dorso/fisiopatologia , Inquéritos e Questionários , Telemedicina , Comunicação por Videoconferência
10.
Arthroscopy ; 30(2): 178-87, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24388452

RESUMO

PURPOSE: The purpose of this in vitro biomechanical study was to assess the effects of the remplissage procedure for small- and large-sized Hill-Sachs lesions (HSLs) on shoulder range of motion (ROM) with a special interest in the apprehension position. METHODS: HSLs of 50% and 100% of the glenoid width were simulated in 7 cadaveric shoulders as small and large lesions, respectively, and the postoperative condition was reproduced by placing suture anchors on the articular surface and tying down the infraspinatus at the medial edge of the would-be lesion site. ROMs were measured in abduction, internal rotation, and external rotation with the humerus in the adducted and abducted position. In addition, the ROM was measured in the anterior apprehension position, in which 2 torques of external rotation and extension were applied simultaneously, and external rotation and horizontal extension ROMs were measured with the humerus in different abduction angles (20°, 40°, and 60°). RESULTS: For standard ROMs, the procedure for the 50% HSL maintained complete ROMs, whereas the procedure for the 100% HSL significantly decreased external rotation ROM with the humerus in both the adducted and abducted positions, as well as abduction ROM. In the apprehension position, remplissage for the 50% HSL decreased extension ROM with the humerus abducted to 40° and 60°. Remplissage for the 100% HSL significantly decreased both external and extension ROMs regardless of the humeral abduction angle. CONCLUSIONS: In the cadaveric model with an intact humeral head and the simulated postoperative condition, the remplissage procedure for a large HSL caused significant restrictions in ROM of abduction in the scapular plane and external rotation with the humerus in both adduction and abduction. It also caused significant restrictions in both external rotation and extension ROMs in the apprehension position. CLINICAL RELEVANCE: The indication for the remplissage procedure for the larger HSL should be considered carefully, especially for the competitive throwing athlete who needs exceptional external rotation ROM for optimal overhead throwing performance.


Assuntos
Procedimentos Ortopédicos/métodos , Amplitude de Movimento Articular , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia , Âncoras de Sutura , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Luxação do Ombro/fisiopatologia , Articulação do Ombro/fisiopatologia
11.
Clin Anat ; 27(5): 702-6, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24214830

RESUMO

The supraspinatus tendon consists morphologically of two sub-regions, anterior and posterior. The anterior sub-region is thick and tubular while the posterior is thin and strap-like. The purpose of this study was to compare the structural and mechanical properties of the anterior and posterior sub-regions of the supraspinatus tendon. The supraspinatus tendons from seven human cadaveric shoulders were morphologically divided into the anterior and posterior sub-regions. Length, width, and thickness were measured. A servo-hydraulic testing machine (MTS Systems Corporation, Minneapolis, MN) was used for tensile testing. The maximal load at failure, modulus of elasticity and ultimate tendon stress were calculated. Repeated measures were used for statistical comparisons. The mean anterior tendon cross-sectional area was 47.3 mm(2) and the posterior was 32.1 mm(2) . Failure occurred most often at the insertion site: anterior (5/7) and posterior (6/7). All parameters of the anterior sub-region were significantly greater than those of the posterior sub-region. The moduli of elasticity at the insertion site were 592.4 MPa in the anterior sub-region and 217.7 MPa in the posterior (P = 0.01). The ultimate failure loads were 779.2 N in the anterior sub-region and 335.6 N in the posterior (P = 0.003). The ultimate stresses were 22.1 MPa in the anterior sub-region and 11.6 MPa in the posterior (P = 0.008). We recognized that the anterior and posterior sub-regions of the SSP tendon have significantly different mechanical properties. In a future study, we need to evaluate how best to repair an SSP tendon considering these region-specific properties.


Assuntos
Articulação do Ombro/fisiologia , Tendões/fisiologia , Resistência à Tração/fisiologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos/fisiologia , Cadáver , Elasticidade/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Suporte de Carga/fisiologia
12.
J Orthop Res ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956833

RESUMO

The scaphotrapeziotrapezoid (STT) joint is involved in load transmission between the wrist and thumb. A quantitative description of baseline STT joint morphometrics is needed to capture the variation of normal anatomy as well as to guide staging of osteoarthritis. Statistical shape modeling (SSM) techniques quantify variations in three-dimensional shapes and relative positions. The objectives of this study are to describe the morphology of the STT joint using a multi-domain SSM. We asked: (1) What are the dominant modes of variation that impact bone and articulation morphology at the STT joint, and (2) what are the morphometrics of SSM-generated STT joints? Thirty adult participants were recruited to a computed tomography study of normal wrist imaging and biomechanics. Segmentations of the carpus were converted to three-dimensional triangular surface meshes. A multi-domain, particle-based entropy system SSM was used to quantify variation in carpal bone shape and position as well as articulation morphology. Articular surface areas and interosseous proximity distributions were calculated between mesh vertex pairs on adjacent bones within distance (2.0 mm) and surface-normal angular (35°) thresholds. In the SSM, the first five modes of variation captured 76.2% of shape variation and contributed to factors such as bone scale, articular geometries, and carpal tilt. Median interosseous proximities-a proxy for joint space-were 1.39 mm (scaphotrapezium), 1.42 mm (scaphotrapezoid), and 0.61 mm (trapeziotrapezoid). This study quantifies morphological and articular variations at the STT joint, presenting a range of normative anatomy. The range of estimated interosseous proximities may guide interpretation of imaging-derived STT joint space.

13.
Med Eng Phys ; 128: 104172, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38789217

RESUMO

Scapholunate interosseous ligament injuries are a major cause of wrist instability and can be difficult to diagnose radiographically. To improve early diagnosis of scapholunate ligament injuries, we compared injury detection between bilateral routine clinical radiographs, static CT, and dynamic four-dimensional CT (4DCT) during wrist flexion-extension and radioulnar deviation. Participants with unilateral scapholunate ligament injuries were recruited to a prospective clinical trial investigating the diagnostic utility of 4DCT imaging for ligamentous wrist injury. Twenty-one participants underwent arthroscopic surgery to confirm scapholunate ligament injury. Arthrokinematics, defined as distributions of interosseous proximities across radioscaphoid and scapholunate articular surfaces at different positions within the motion cycle, were used as CT-derived biomarkers. Preoperative radiographs, static CT, and extrema of 4DCT were compared between uninjured and injured wrists using Wilcoxon signed rank or Kolmogorov-Smirnov tests. Median interosseous proximities at the scapholunate interval were significantly greater in the injured versus the uninjured wrists at static-neutral and maximum flexion, extension, radial deviation, and ulnar deviation. Mean cumulative distribution functions at the radioscaphoid joint were not significantly different between wrists but were significantly shifted at the scapholunate interval towards increased interosseous proximities in injured versus uninjured wrists in all positions. Median and cumulative distribution scapholunate proximities from static-neutral and 4DCT-derived extrema reflect injury status.


Assuntos
Tomografia Computadorizada Quadridimensional , Humanos , Masculino , Estudos Prospectivos , Feminino , Adulto , Tomografia Computadorizada Quadridimensional/métodos , Osso Escafoide/diagnóstico por imagem , Osso Escafoide/lesões , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/lesões , Osso Semilunar/diagnóstico por imagem , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Ligamentos/diagnóstico por imagem , Ligamentos/lesões , Adulto Jovem , Cinética , Traumatismos do Punho/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/fisiopatologia
14.
Nat Commun ; 15(1): 2201, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561341

RESUMO

Intrathecal delivery of autologous culture-expanded adipose tissue-derived mesenchymal stem cells (AD-MSC) could be utilized to treat traumatic spinal cord injury (SCI). This Phase I trial (ClinicalTrials.gov: NCT03308565) included 10 patients with American Spinal Injury Association Impairment Scale (AIS) grade A or B at the time of injury. The study's primary outcome was the safety profile, as captured by the nature and frequency of adverse events. Secondary outcomes included changes in sensory and motor scores, imaging, cerebrospinal fluid markers, and somatosensory evoked potentials. The manufacturing and delivery of the regimen were successful for all patients. The most commonly reported adverse events were headache and musculoskeletal pain, observed in 8 patients. No serious AEs were observed. At final follow-up, seven patients demonstrated improvement in AIS grade from the time of injection. In conclusion, the study met the primary endpoint, demonstrating that AD-MSC harvesting and administration were well-tolerated in patients with traumatic SCI.


Assuntos
Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais , Traumatismos da Medula Espinal , Traumatismos da Coluna Vertebral , Humanos , Transplante Autólogo/efeitos adversos , Transplante de Células-Tronco Mesenquimais/efeitos adversos , Transplante de Células-Tronco Mesenquimais/métodos , Traumatismos da Medula Espinal/terapia , Traumatismos da Medula Espinal/complicações , Traumatismos da Coluna Vertebral/complicações , Resultado do Tratamento
15.
Nat Med ; 30(5): 1276-1283, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38769431

RESUMO

Cervical spinal cord injury (SCI) leads to permanent impairment of arm and hand functions. Here we conducted a prospective, single-arm, multicenter, open-label, non-significant risk trial that evaluated the safety and efficacy of ARCEX Therapy to improve arm and hand functions in people with chronic SCI. ARCEX Therapy involves the delivery of externally applied electrical stimulation over the cervical spinal cord during structured rehabilitation. The primary endpoints were safety and efficacy as measured by whether the majority of participants exhibited significant improvement in both strength and functional performance in response to ARCEX Therapy compared to the end of an equivalent period of rehabilitation alone. Sixty participants completed the protocol. No serious adverse events related to ARCEX Therapy were reported, and the primary effectiveness endpoint was met. Seventy-two percent of participants demonstrated improvements greater than the minimally important difference criteria for both strength and functional domains. Secondary endpoint analysis revealed significant improvements in fingertip pinch force, hand prehension and strength, upper extremity motor and sensory abilities and self-reported increases in quality of life. These results demonstrate the safety and efficacy of ARCEX Therapy to improve hand and arm functions in people living with cervical SCI. ClinicalTrials.gov identifier: NCT04697472 .


Assuntos
Braço , Mãos , Quadriplegia , Traumatismos da Medula Espinal , Humanos , Quadriplegia/terapia , Quadriplegia/fisiopatologia , Masculino , Mãos/fisiopatologia , Feminino , Pessoa de Meia-Idade , Adulto , Braço/fisiopatologia , Traumatismos da Medula Espinal/terapia , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/reabilitação , Estimulação da Medula Espinal/métodos , Resultado do Tratamento , Qualidade de Vida , Estudos Prospectivos , Doença Crônica , Idoso , Terapia por Estimulação Elétrica/métodos , Terapia por Estimulação Elétrica/efeitos adversos
16.
Top Spinal Cord Inj Rehabil ; 29(4): 1-15, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38076494

RESUMO

Background: Individuals with spinal cord injury (SCI) have lower levels of physical activity compared to the nondisabled population. Exercise guidelines recommend moderate or vigorous exercise to improve cardiovascular health and reduce cardiometabolic risk factors in persons with SCI. High-intensity interval training (HIIT) is a popular exercise choice and encompasses brief periods of vigorous exercise paired with intermittent periods of recovery. Objectives: This review describes the available literature on HIIT for individuals with SCI, including differences in protocol design and suggested areas of further investigation. Methods: Our institution's library system performed the comprehensive search. The primary keywords and phrases used to search included spinal cord injury, high-intensity interval training, tetraplegia, paraplegia, and several other related terms. Results: Initially 62 records were screened, and 36 were deemed outside the scope of this review. Twenty-six studies published between 2001 and 2021 fulfilled the eligibility criteria and were divided among two researchers for review and analysis. All records required persons with SCI and a standardized HIIT intervention. Study design varied widely with respect to mode of exercise, prescribed intensity, duration of performance intervals, and session duration. This variability necessitates further investigation into the specifics of a HIIT prescription and the associated outcomes for persons with SCI. Conclusion: Standardization of HIIT protocols may lead to more robust conclusions regarding its effects on cardiorespiratory fitness as well as mitigation of cardiometabolic risk factors. Meta-analyses will eventually be needed on proper dosing and session parameters to improve cardiorespiratory fitness and cardiometabolic risk factors.


Assuntos
Aptidão Cardiorrespiratória , Sistema Cardiovascular , Treinamento Intervalado de Alta Intensidade , Traumatismos da Medula Espinal , Humanos , Treinamento Intervalado de Alta Intensidade/métodos , Exercício Físico
17.
medRxiv ; 2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37425869

RESUMO

Objective: This pilot study aimed to assess the efficacy of a 16-week at-home high-intensity interval training (HIIT) program among individuals with spinal cord injury (SCI). Methods: Eight individuals (age: 47±11 (SD) years, 3 females) with SCI below the sixth thoracic vertebrae participated in a 16-week at-home HIIT program using an arm ergometer. Participants completed baseline graded exercise tests to determine target heart rate zones. HIIT was prescribed thrice per week. Each training session consisted of six one-minute bouts with a target heart rate ~80% heart rate reserve (HRR), interspersed with two minutes of recovery at ~30% HRR. A portable heart rate monitor and phone application provided visual feedback during training and allowed for measurements of adherence and compliance. Graded exercise tests were completed after 8 and 16 weeks of HIIT. Surveys were administered to assess participation, self-efficacy, and satisfaction. Results: Participants demonstrated a decrease in submaximal cardiac output (P=0.028) and an increase in exercise capacity (peak power output, P=0.027) following HIIT, indicative of improved exercise economy and maximal work capacity. An 87% adherence rate was achieved during the HIIT program. Participants reached a high intensity of 70% HRR or greater during ~80% of intervals. The recovery HRR target was reached during only ~35% of intervals. Self-reported metrics of satisfaction and self-efficacy with at-home HIIT scored moderate to high. Conclusion: Participants demonstrated an improvement in exercise economy and maximal work capacity following at-home HIIT. Additionally, participant adherence, compliance, satisfaction, and self-efficacy metrics suggest that at-home HIIT was easily implemented and enjoyable.

18.
J Wrist Surg ; 12(3): 248-260, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37223378

RESUMO

Background In predynamic or dynamic scapholunate (SL) instability, standard diagnostic imaging may not identify SL interosseous ligament (SLIL) injury, leading to delayed detection and intervention. This study describes the use of four-dimensional computed tomography (4DCT) in identifying early SLIL injury and following injured wrists to 1-year postoperatively. Description of Technique 4DCT acquires a series of three-dimensional volume data with high temporal resolution (66 ms). 4DCT-derived arthrokinematic data can be used as biomarkers of ligament integrity. Patients and Methods This study presents the use of 4DCT in a two-participant case series to assess changes in arthrokinematics following unilateral SLIL injury preoperatively and 1-year postoperatively. Patients were treated with volar ligament repair with volar capsulodesis and arthroscopic dorsal capsulodesis. Arthrokinematics were compared between uninjured, preoperative injured, and postoperative injured (repaired) wrists. Results 4DCT detected changes in interosseous distances during flexion-extension and radioulnar deviation. Generally, radioscaphoid joint distances were greatest in the uninjured wrist during flexion-extension and radioulnar deviation, and SL interval distances were smallest in the uninjured wrist during flexion-extension and radioulnar deviation. Conclusion 4DCT provides insight into carpal arthrokinematics during motion. Distances between the radioscaphoid joint and SL interval can be displayed as proximity maps or as simplified descriptive statistics to facilitate comparisons between wrists and time points. These data offer insight into areas of concern for decreased interosseous distance and increased intercarpal diastasis. This method may allow surgeons to assess whether (1) injury can be visualized during motion, (2) surgery repaired the injury, and (3) surgery restored normal carpal motion. Level of Evidence Level IV, Case series.

19.
Clin Biomech (Bristol, Avon) ; 107: 106007, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37295340

RESUMO

BACKGROUND: Scapholunate interosseous ligament injuries are prevalent and often challenging to diagnose radiographically. Four-dimensional CT allows visualization of carpal bones during motion. We present a cadaveric model of sequential ligamentous sectionings ("injuries") to quantify their effects on interosseous proximities at the radioscaphoid joint and scapholunate interval. We hypothesized that injury, wrist position, and their interaction affect carpal arthrokinematics. METHODS: Eight cadaveric wrists were moved through flexion-extension and radioulnar deviation after injuries. Dynamic CT images of each motion were acquired in each injury condition using a second-generation dual-source CT scanner. Carpal osteokinematics were used to calculate arthrokinematic interosseous proximity distributions during motion. Median interosseous proximities were normalized and categorized by wrist position. Linear mixed-effects models and marginal means tests were used to compare distributions of median interosseous proximities. FINDINGS: The effect of wrist position was significant for both flexion-extension and radioulnar deviation at the radioscaphoid joint; the effect of injury was significant for flexion-extension at the scapholunate interval; and the effect of their interaction was significant for radioulnar deviation at the scapholunate interval. Across wrist positions, radioscaphoid median interosseous proximities were less able to distinguish injury conditions versus scapholunate proximities. Median interosseous proximities at the scapholunate interval are majoritively able to detect differences between less (Geissler I-III) versus more (Geissler IV) severe injuries when the wrist is flexed, extended, and ulnarly-deviated. INTERPRETATION: Dynamic CT enhances our understanding of carpal arthrokinematics in a cadaveric model of SLIL injury. Scapholunate median interosseous proximities in flexion, extension, and ulnar deviation best demonstrate ligamentous integrity.


Assuntos
Ossos do Carpo , Osso Escafoide , Humanos , Tomografia Computadorizada Quadridimensional , Fenômenos Biomecânicos , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/lesões , Articulação do Punho/diagnóstico por imagem , Cadáver , Osso Escafoide/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA