Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Respir Res ; 25(1): 266, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965565

RESUMO

BACKGROUND: This study explored the relationship between inflammatory markers and glucocorticoid dosage upon admission. METHODS: We conducted a retrospective analysis of 206 patients with refractory Mycoplasma pneumoniae pneumonia (RMPP) admitted to a Children's Hospital from November 2017 to January 2022. Patients were categorized into three groups based on their methylprednisolone dosage: low-dose (≤ 2 mg/kg/d), medium-dose (2-10 mg/kg/d), and high-dose (≥ 10 mg/kg/d). We compared demographic data, clinical manifestations, laboratory findings, and radiological outcomes. Spearman's rank correlation coefficient was used to assess relationships between variables. RESULTS: The median age was highest in the low-dose group at 7 years, compared to 5.5 years in the medium-dose group and 6 years in the high-dose group (P < 0.001). The body mass index (BMI) was also highest in the low-dose group at 16.12, followed by 14.86 in the medium-dose group and 14.58 in the high-dose group (P < 0.001). More severe radiographic findings, longer hospital stays, and greater incidence of hypoxia were noted in the high-dose group (P < 0.05). Additionally, significant increases in white blood cells, C-reactive protein, procalcitonin, lactate dehydrogenase (LDH), alanine transaminase, aspartate transaminase, ferritin, erythrocyte sedimentation rate, and D-dimer levels were observed in the high-dose group (P < 0.05). Specifically, LDH and ferritin were markedly higher in the high-dose group, with levels at 660.5 U/L and 475.05 ng/mL, respectively, compared to 450 U/L and 151.4 ng/mL in the medium-dose group, and 316.5 U/L and 120.5 ng/mL in the low-dose group. Correlation analysis indicated that LDH and ferritin levels were significantly and positively correlated with glucocorticoid dose (Spearman ρ = 0.672 and ρ = 0.654, respectively; P < 0.001). CONCLUSIONS: Serum LDH and ferritin levels may be useful biomarkers for determining the appropriate corticosteroid dosage in treating children with RMPP.


Assuntos
Biomarcadores , Ferritinas , L-Lactato Desidrogenase , Pneumonia por Mycoplasma , Humanos , Feminino , Masculino , Pneumonia por Mycoplasma/tratamento farmacológico , Pneumonia por Mycoplasma/sangue , Pneumonia por Mycoplasma/diagnóstico , Criança , Ferritinas/sangue , Estudos Retrospectivos , Pré-Escolar , Biomarcadores/sangue , L-Lactato Desidrogenase/sangue , Relação Dose-Resposta a Droga , Adolescente , Mycoplasma pneumoniae/efeitos dos fármacos , Metilprednisolona/administração & dosagem , Glucocorticoides/administração & dosagem
2.
Front Nutr ; 11: 1341219, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38590829

RESUMO

Introduction: Difenoconazole (DIFE) is a common pesticide used in citrus cultivation; excessive intake can cause neurological damage to the organism, and the existing colloidal gold immunochromatographic test strips cannot meet the requirements for the detection of citrus samples. Methods: Difenoconazole test strip was prepared based on the colloidal gold immunochromatographic technique (GICT), and its application in citrus samples was investigated; with colloidal gold (CG) as the probe, the optimization of GICT parameters, and the determination of reaction method, the immunochromatographic test strips for the detection of DIFE in citrus was developed, and the limit of detection (LOD), specificity, accuracy, and stability of the test strips were verified. Results: The results showed that the visual detection limit of the prepared colloidal gold immunochromatographic test strips was 0.2 mg/kg and the quantitative range was 0.06-0.6 mg/kg, and the test strips could specifically identify DIFE and have no cross-reaction with other common triazole pesticides. The detection method established in this study was verified by the GC-MS method, and the detection results achieved good consistency (R2 > 0.98). Conclusion: The test strips developed in this study have good performance and can be used for highly sensitive detection of citrus samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA