Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Audiol Neurootol ; 21(6): 356-364, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28068659

RESUMO

BACKGROUND: Delivery of therapeutic agents directly through the round window (RW) offers promise for treating sensorineural hearing loss. However, hearing loss can result from the surgical approach itself, and the reasons for this are poorly understood. We examined the hearing loss following the 3 major steps involved with the RW approach to access the mouse cochlea: bullostomy, RW puncture, and RW injection. METHODS: Twenty-one adult CBA/J mice underwent bullostomy alone, 10 underwent RW puncture, and 8 underwent RW injection with PBS with 5% glycerol. Auditory brainstem responses (ABR) and otoscopy were performed preoperatively and up to 6 weeks postoperatively. Hair cells were stained, and survival was assessed using immunofluorescence. RESULTS: One week postoperatively, mice in all groups showed significant threshold shifts. Otoscopy revealed approximately half of all mice had middle ear effusion (MEE), with a higher incidence of effusion in the RW puncture and RW injection groups. Those with MEE had significant ABR threshold shifts, whereas those without MEE had minimal hearing loss. MEE persisted through 6 weeks in a majority of cases, but in those mice with MEE resolution, there was at least partial improvement in hearing. Immunohistochemistry showed minimal loss of hair cells in all animals. CONCLUSION: MEE is highly correlated with hearing loss in mice undergoing RW surgery. Otoscopy is an important adjunct to consider after ear surgery in mice, as MEE may contribute to postsurgical hearing loss.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva/etiologia , Otite Média com Derrame/etiologia , Procedimentos Cirúrgicos Otológicos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Janela da Cóclea/cirurgia , Animais , Sobrevivência Celular , Células Ciliadas Auditivas , Perda Auditiva/fisiopatologia , Injeções , Camundongos , Camundongos Endogâmicos CBA , Otite Média com Derrame/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Punções , Recuperação de Função Fisiológica
2.
Laryngoscope ; 132(9): 1753-1759, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34904721

RESUMO

OBJECTIVES/HYPOTHESIS: To quantify the degree of color match achieved during microvascular facial reconstruction, and to describe a novel technique for improving reconstructive skin color match. We hypothesize that split-thickness skin grafts (STSG) placed atop de-epithelialized free tissue produces better facial skin color match than free tissue with intact epithelium. STUDY DESIGN: Cross sectional photographic study of reconstructed facial skin color match. METHODS: Sixty-eight adults, who underwent head and neck reconstructive surgery, were divided into six categories based on cutaneous reconstructive technique: cervicofacial flap, radial forearm free flap (RFFF), fibula free flap, anterolateral thigh free flap (ALT), STSG over adiopofascial flap (STAFF), and STSG over myogenous flap (STMF). Averaged color samplings of the reconstructed defect and adjacent normal skin were taken from digital photographs. The color difference was calculated using the delta-E calculation. Blinded expert observers also rated the degree of color match. Nonparametric cohort contrast and correlation statistical analyses were performed. RESULTS: The mean delta-E's and 10-point Likert ratings for the ALT, fibula, RFFF, STAFF, STMF, and cervicofacial flaps were 11.6, 10.0, 7.7, 6.3, 8.8, and 4.7, and 5.1, 6.4, 2.4, 3.2, 2.7, and 1.1, respectively. Likert scale inter-rater correlation was strong, with coefficient = 0.80. CONCLUSIONS: On average, STSG over de-epithelialized myogenous and adipofascial free tissue transfers produced a better color match than the skin paddles of donor sites, with the exception of the radial forearm donor site. Delta-E values obtained from photos correlated well with expert ratings of color match. This reliable technique for quantifying color match may be used in future studies. LEVEL OF EVIDENCE: 3 Laryngoscope, 132:1753-1759, 2022.


Assuntos
Retalhos de Tecido Biológico , Procedimentos de Cirurgia Plástica , Adulto , Estudos Transversais , Retalhos de Tecido Biológico/transplante , Humanos , Procedimentos de Cirurgia Plástica/métodos , Pigmentação da Pele , Transplante de Pele/métodos
3.
Facial Plast Surg Clin North Am ; 24(2): 89-95, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27105794

RESUMO

Slight alterations in the intricate anatomy of the upper and lower eyelid or their underlying structures can have pronounced consequences for ocular esthetics and function. The understanding of periorbital structures and their interrelationships continues to evolve and requires consideration when performing complex eyelid interventions. Maintaining a detailed appreciation of this region is critical to successful cosmetic or reconstructive surgery. This article presents a current review of the anatomy of the upper and lower eyelid with a focus on surgical implications.


Assuntos
Pálpebras/anatomia & histologia , Blefaroplastia , Pálpebras/cirurgia , Humanos
4.
Otol Neurotol ; 34(3): 516-21, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23449440

RESUMO

OBJECTIVE: To analyze the effects of residual hearing on postoperative speech performance in traditional cochlear implant (CI) patients implanted with a conventional electrode. STUDY DESIGN: Retrospective review. SETTING: Academic tertiary referral center. PATIENTS: A total of 129 adults implanted by a single surgeon at a tertiary care facility between June 2005 and November 2010 with measurable preoperative pure tone thresholds at any frequency were included. INTERVENTION: Cochlear implantation with a conventional electrode via an anterior inferior cochleostomy. MAIN OUTCOME MEASURE: Speech perception using monosyllabic word scores in quiet and sentences in quiet and noise in the electric (CI-only) condition of the implanted ear. Preservation of hearing was defined as complete for postoperative thresholds within 10 dB of preimplant values and partial if greater than 11 dB. Pure tone audiometry and speech perception testing were performed preoperatively and at regular intervals postoperatively, with the 1-year evaluation being the final outcome period. RESULTS: Preservation at any frequency or level was not a factor in speech perception outcome, although preservation was more common in low frequencies. Hearing preservation was correlated with younger age at implantation, but was not related to length of hearing loss, cause of deafness, device type, sex, preoperative speech performance, or low-frequency pure-tone average. CONCLUSION: Hearing can be preserved in traditional CI patients implanted with a conventional electrode. Although preservation of hearing may have implications for future technology, it is not currently correlated with speech performance in the CI-only condition.


Assuntos
Percepção Auditiva/fisiologia , Limiar Auditivo/fisiologia , Implante Coclear/métodos , Perda Auditiva/cirurgia , Audição/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Audiometria de Tons Puros , Implantes Cocleares , Feminino , Perda Auditiva/fisiopatologia , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Percepção da Fala , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA