Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
N Engl J Med ; 351(5): 460-9, 2004 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-15282353

RESUMO

BACKGROUND: Familial cardiac myxomas occur in the hereditary syndrome Carney complex. Although PRKAR1A mutations can cause the Carney complex, the disorder is genetically heterogeneous. To identify the cause of a Carney complex variant associated with distal arthrogryposis (the trismus-pseudocamptodactyly syndrome), we performed clinical and genetic studies. METHODS: A large family with familial cardiac myxomas and the trismus-pseudocamptodactyly syndrome (Family 1) was identified and clinically evaluated along with two families with trismus and pseudocamptodactyly. Genetic linkage analyses were performed with the use of microsatellite polymorphisms to determine a locus for this Carney complex variant. Positional cloning and mutational analyses of candidate genes were performed to identify the genetic cause of disease in the family with the Carney complex as well as in the families with the trismus-pseudocamptodactyly syndrome. RESULTS: Clinical evaluations demonstrated that the Carney complex cosegregated with the trismus-pseudocamptodactyly syndrome in Family 1, and genetic analyses demonstrated linkage of the disease to chromosome 17p12-p13.1 (maximum multipoint lod score, 4.39). Sequence analysis revealed a missense mutation (Arg674Gln) in the perinatal myosin heavy-chain gene (MYH8). The same mutation was also found in the two families with the trismus-pseudocamptodactyly syndrome. Arg674 is highly conserved evolutionarily, localizes to the actin-binding domain of the perinatal myosin head, and is close to the ATP-binding site. We identified nonsynonymous MYH8 polymorphisms in patients with cardiac myxoma syndromes but without arthrogryposis. CONCLUSIONS: We describe a novel heart-hand syndrome involving familial cardiac myxomas and distal arthrogryposis and demonstrate that these disorders are caused by a founder mutation in the MYH8 gene. Our findings demonstrate novel roles for perinatal myosin in both the development of skeletal muscle and cardiac tumorigenesis.


Assuntos
Artrogripose/genética , Neoplasias Cardíacas/genética , Mutação de Sentido Incorreto , Cadeias Pesadas de Miosina/genética , Mixoma/genética , Transtornos da Pigmentação/genética , Trismo/genética , Análise Mutacional de DNA , Feminino , Dedos/anormalidades , Genótipo , Mutação em Linhagem Germinativa , Humanos , Escore Lod , Masculino , Cadeias Pesadas de Miosina/química , Neoplasias Primárias Múltiplas/genética , Linhagem , Síndrome
2.
Am J Cardiol ; 100(10): 1577-83, 2007 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-17996523

RESUMO

The aims of the echocardiographic substudy of this multicenter trial were to evaluate the use of quantitative assessment of mitral regurgitation (MR) severity using serial echocardiography and to assess the efficacy of percutaneous mitral valve repair. Previous surgical repair studies did not use quantitative echocardiographic methods. Results of a percutaneous mitral valve repair clip device in a core echocardiographic laboratory were evaluated. Published parameters for quantifying MR were used in a systematic protocol to qualify patients for study entry and evaluate treatment efficacy at discharge and 6 months after clip repair. Baseline results were presented for 55 patients, and follow-up results, for 49. Ninety-eight percent of required echocardiographic studies were submitted to the core laboratory, and >85% of required measurements were possible. At baseline, mean regurgitant volume was 54.8 +/- 24 ml, regurgitant fraction was 46.9 +/-16.2%, effective regurgitant orifice area was 0.71 +/- 0.40 cm(2), and vena contracta width was 0.66 +/- 0.20 cm. Based on a severity scale of 1 to 4, mean color flow grade was 3.4 +/- 0.7, and mean pulmonary vein flow was 2.8 +/- 1.2. In patients with a clip at 6 months, all measurements of MR severity were significantly decreased versus baseline, with mean regurgitant volume decreased from 50.3 to 27.5 ml (change -22.8 ml; p <0.0001), regurgitant fraction from 44.6% to 28.9% (change -15.7%; p <0.0001), color flow grade from an average of 3.4 to 1.8 (change -1.6; p <0.0001), and pulmonary vein flow from 2.8 to 1.8 (change -1.0; p <0.0018). In conclusion, quantitative assessment of MR is feasible in a multicenter trial, and percutaneous mitral repair with the MitraClip produces a sustained decrease in MR severity to moderate or less for > or =6 months.


Assuntos
Ecocardiografia Doppler em Cores , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Índice de Gravidade de Doença , Procedimentos Cirúrgicos Cardíacos/instrumentação , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Fluxo Sanguíneo Regional
3.
Wiad Lek ; 60(5-6): 291-3, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17966897

RESUMO

A 22-year-old Caucasian woman presented with acrocyanosis of fingers and toes and dyspnea on exertion. Initial echocardiography showed multiple right and left atrial myxomata, mild enlargement of the left ventricle and severely depressed left ventricular systolic function. Resection of the tumors and replacement of the myxomatous mitral valve led to a complete resolution of echocardiographic evidence of left ventricular dysfunction, and was accompanied by disappearance of skin findings and symptoms of asthma.


Assuntos
Neoplasias Cardíacas/diagnóstico por imagem , Mixoma/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Doença Aguda , Adulto , Cianose/diagnóstico , Dispneia/diagnóstico , Ecocardiografia , Feminino , Dedos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Humanos , Valva Mitral , Mixoma/complicações , Mixoma/cirurgia , Recuperação de Função Fisiológica , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Obstrução do Fluxo Ventricular Externo/etiologia
4.
Am J Hosp Palliat Care ; 34(5): 423-429, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26941370

RESUMO

BACKGROUND: Advance care planning (ACP) discussions afford patients and physicians a chance to better understand patients' values and wishes regarding end-of-life care; however, these conversations typically take place late in the course of a disease. The goal of this study was to clarify attitudes of oncologists, cardiologists, and primary care physicians (PCPs) toward ACP and to identify persistent barriers to timely ACP discussion following a quality improvement initiative at our health system geared at improvement in ACP implementation. METHODS: A 20-question, cross-sectional online survey was created and distributed to cardiologists, oncologists, PCPs, and cardiology and oncology support staff at the NorthShore University HealthSystem (NorthShore) from February to March 2015. A total of 117 individuals (46% of distributed) completed the surveys. The results were compiled using an online survey analysis tool (SurveyMonkey, Inc., Palo Alto, California, USA). RESULTS: Only 15% of cardiologists felt it was their responsibility to conduct ACP discussions with their patients having congestive heart failure (CHF). In contrast, 68% of oncologists accepted this discussion as their responsibility in patients with terminal cancer ( P < .01). These views were mirrored by PCPs, as 68% of PCPs felt personally responsible for ACP discussion with patients having CHF, while only 34% felt the same about patients with cancer. Reported documentation of these discussions in the electronic health record was inconsistent between specialties. Among all surveyed specialties, lack of time was the major barrier limiting ACP discussion. Perceived patient discomfort and discomfort of the patient's family toward these discussions were also significant reported barriers. CONCLUSION: Attitudes toward ACP implementation vary considerably by medical specialty and medical condition, with oncologists in this study tending to feel more personal responsibility for these discussions with patients having cancer than cardiologists with their patients having heart failure. Robust implementation of ACP across the spectrum of medical diagnoses is likely to require a true collaboration between office-based PCPs and specialists in both the inpatient and the ambulatory settings.


Assuntos
Planejamento Antecipado de Cuidados/estatística & dados numéricos , Atitude do Pessoal de Saúde , Pessoal de Saúde/psicologia , Insuficiência Cardíaca/psicologia , Neoplasias/psicologia , Cardiologia , Estudos Transversais , Feminino , Humanos , Masculino , Oncologia , Médicos de Atenção Primária , Assistência Terminal/psicologia
5.
J Am Soc Echocardiogr ; 20(10): 1131-40, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17570634

RESUMO

OBJECTIVE: Percutaneous mitral repair is rapidly developing as an alternative to cardiac surgery in select patients. The Evalve percutaneous E2E system uses the MitraClip to replicate the surgical suture-based approach. This procedure requires real-time echocardiographic guidance in a unique and significant collaboration between echocardiographer and interventionalist. transesophageal echocardiography (TEE) is used as the primary imaging modality to guide this procedure and is essential to its success. METHODS: In EVEREST I, the US multicenter phase I safety and feasibility trial, 47 patients with 3 or 4+ mitral regurgitation (MR) were enrolled. The trial involved a standardized echocardiographic imaging protocol with a standardized anatomic-based vocabulary, predetermined standard TEE views, preprocedural strategy meetings, and display of echocardiographic aids to optimize communication and procedural efficiency during placement of the clip. RESULTS: TEE guidance facilitated the creation of a double-orifice mitral valve in all 47 patients enrolled (100%), and 40 patients were discharged with 1 or more clips (85%). At discharge, successful placement of a clip and

Assuntos
Procedimentos Cirúrgicos Cardíacos/instrumentação , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Mitral/cirurgia , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Cateterismo Cardíaco , Desenho de Equipamento , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Índice de Gravidade de Doença , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 68(6): 821-8, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17080467

RESUMO

INTRODUCTION: The Endovascular Valve Edge-to-Edge REpair STudies (EVEREST) are investigating a percutaneous technique for edge-to-edge mitral valve repair with a repositionable clip. The effects on the mitral valve gradient (MVG) and mitral valve area (MVA) are not known. METHODS: Twenty seven patients with moderate to severe or severe mitral regurgitation (MR) were enrolled. Echocardiography was performed preprocedure, at discharge, and at 1, 6, and 12 months. Mean MVG was measured by Doppler and MVA by planimetry and pressure half-time, and evaluated in a central core laboratory. Pre- and postclip deployment, simultaneous left atrial/pulmonary capillary wedge and left ventricular pressures were obtained in eight patients. RESULTS: Three patients did not receive a clip, six patients had their clip(s) explanted by 6 months (none for mitral stenosis), and four were repaired with two clips. Results are notable for a slight increase in mean MVG by Doppler postclip deployment (1.79 +/- 0.89 to 3.31 +/- 2.09 mm Hg, P < 0.01) and an expected decrease in MVA by planimetry (6.49 +/- 1.61 to 4.46 +/- 2.14 cm(2), P < 0.001) and by pressure half time (4.35 +/- 0.98 to 3.01 +/- 1.42 cm(2), P < 0.05). There were no significant changes in hemodynamic parameters postclip deployment by direct pressure measurements. There was no change in MVA by planimetry from discharge to 12 months (3.90 +/- 1.90 to 3.79 +/- 1.54 cm(2), P = 0.78). CONCLUSIONS: Echocardiographic and hemodynamic measurements after percutaneous mitral valve repair with the MitraClip show an expected decrease in mitral valve area with no evidence of clinically significant mitral stenosis either immediately after clip deployment or after 12 months of follow-up.


Assuntos
Insuficiência da Valva Mitral/cirurgia , Instrumentos Cirúrgicos , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos , Insuficiência da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/prevenção & controle , Pressão Propulsora Pulmonar , Instrumentos Cirúrgicos/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA